首页 | 本学科首页   官方微博 | 高级检索  
     检索      

交叉并行管道阴极保护干扰数值模拟
引用本文:李丹丹,毕武喜,祁惠爽,等.交叉并行管道阴极保护干扰数值模拟[J].油气储运,2014(3):287-291.
作者姓名:李丹丹  毕武喜  祁惠爽  
作者单位:[1]西南石油大学,四川成都610500 [2]中国石油管道科技研究中心,河北廊坊065000 [3]北京输油气分公司,北京102488
基金项目:基金项目:中国石油天然气股份有限公司科研项目“管道阴极保护数值模拟评价技术研究”,01213-3302-0503.
摘    要:针对国内某油气管道存在的阴极保护干扰问题现状,开展检测分析并确定其阴极保护干扰特点。依据埋地管道参数和阴极保护系统工作参数,完成了对应的干扰现场数值模拟分析,结果表明:现场检测数据不能全面反映干扰电位的分布规律,现场检测阴极保护干扰时,必须采用密间隔电位测量技术(CloseIntervalPotentialSurvey,CIPS),必要时借助数值模拟技术辅助分析。为了预先了解对应治理方案的治理效果,利用数值模拟技术对治理方案进行预评估,结果显示治理方案可以消除该处管道的阴极保护干扰影响,同时对治理方案的合理性进行了讨论。借助数值模拟技术对管道阴极保护干扰进行分析的做法,可以为解决类似工程问题提供借鉴。(图7,参12)

关 键 词:交叉并行管道  阴极保护  干扰  数值模拟  治理方案

Numerical simulation of cathodic protection interference in cross/parallel pipeline
LI Dandan,BI Wuxi,QI Huishuang,MU Chengguang,XUE Zhiyuan,CHEN Hongyuan,CHEN Hongmin.Numerical simulation of cathodic protection interference in cross/parallel pipeline[J].Oil & Gas Storage and Transportation,2014(3):287-291.
Authors:LI Dandan  BI Wuxi  QI Huishuang  MU Chengguang  XUE Zhiyuan  CHEN Hongyuan  CHEN Hongmin
Institution:1. Southwest Petroleum University, Chengdu, Sichuan, 610500; 2. PetroChina Pipeline R & D Center, Langfang, Hebei, 065000; 3. PetroChina Beijing Oil & Gas Sub-company, PetroChina Pipeline Company, Beijing, 102488)
Abstract:According to the problem of cathodic protection interference in a pipeline inland, detection analysis is carried out to understand the characteristics of the cathodic protection interference. Based on the parameters of the buried pipeline and the tuning parameters of the cathodic protection system, numerical simulation analysis on the interference field is finished, and the result shows that the spot data cannot fully reflect the distribution of interference potential. Close Interval Potential Survey (CIPS) is needed during the detection of cathodic protection interference in the field, and numerical simulation technology can be used in assistant analysis if necessary. In order to predict the effect of the relevant improvement scheme, pre-evalnation of the scheme is carried out by means of the numerical simulation. The results show that this scheme can eliminate the influence of cathodic protection interference here in the pipeline and its reasonability is discussed in this paper. The way of using numerical simulation to analyze cathodic protection interference on pipeline can provide a reference to the troubleshooting similar construction problems. (7 Figures, 12 References)
Keywords:cross/parallel pipeline  cathodic protection  interference  numerical simulation  improvement scheme
本文献已被 CNKI 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号