Long-term EKG in dogs: comparison between a computerized system and visual arrhythmia analysis] |
| |
Authors: | M Hertel U Kersten R Mischke I Nolte |
| |
Affiliation: | Klinik für kleine Haustiere, Tier?rztlichen Hochschule Hannover. |
| |
Abstract: | Based on results of holter ecg recordings taken from 38 dogs the computerized analyses system turned out as method not exactly valuing the frequency and sensitivity of arrhythmias. Despite there was a significant correlation between the computerized and visual arrhythmia analysis for ventricular respectively supraventricular premature beats, in individual cases there was an important aberration between the particular values. |
| |
Keywords: | |
|