首页 | 本学科首页   官方微博 | 高级检索  
     检索      

Comparison of DC Pollution Flashover Performance of Various Types of Long String Insulators
作者姓名:LUO Li-yun  JIANG Xing-liang  ZHANG Zhi-jin  HU Jian-lin  SUN Cai-xin
作者单位:Key Laboratory of High Voltage Engineering and Electrical New Technology, Ministry of Education, Electrical Engineering College of Chongqing University, Chongqing 400030, China
摘    要:With the development of EHV/UHV DC transmission projects, it is inevitable to study DC pollution flashover performance of long insulator strings. The DC artificial pollution tests of five types of porcelain and glass insulators have been carried out in the artificial climate chamber. The paper analyzes the relationship between 50% flashover voltage U50 and string length, the relationship between U50 and salt deposit density, flashover voltage gradients and valid creepage distances of DC polluted insulators. Based on the test results of insulator strings of 5 - 23 units, there are linear relationship between the 50% DC flashover voltages and string length. The experimental results show that the pollution flashover performances of various types of insulators are different, and that the pollution degree exponents of polluted insulators are affected ainsulator materials and shapes, whose values are 0.3 to 0.36. Under the same pollution degree, the pollution performances of glass insulators have advantage of those of porcelain insulators with the same configuration and the flashover voltage gradient along creepage distance and valid creepage distances of glass insulators are higher than those of porcelain insulators.

关 键 词:insulator    direct  current      flashover  performance      flashover  voltage  gradient      valid  creepage  distance
修稿时间:2007/3/11 0:00:00

Comparison of DC Pollution Flashover Performance of Various Types of Long String Insulators
LUO Li-yun,JIANG Xing-liang,ZHANG Zhi-jin,HU Jian-lin,SUN Cai-xin.Comparison of DC Pollution Flashover Performance of Various Types of Long String Insulators[J].Storage & Process,2007(7):42-45.
Authors:LUO Li-yun  JIANG Xing-liang  ZHANG Zhi-jin  HU Jian-lin  SUN Cai-xin
Institution:Key Laboratory of High Voltage Engineering and Electrical New Technology, Ministry of Education, Electrical Engineering College of Chongqing University, Chongqing 400030, China
Abstract:With the development of EHV/UHV DC transmission projects, it is inevitable to study DC pollution flashover performance of long insulator strings. The DC artificial pollution tests of five types of porcelain and glass insulators have been carried out in the artificial climate chamber. The paper analyzes the relationship between 50% flashover voltage U50 and string length, the relationship between U50 and salt deposit density, flashover voltage gradients and valid creepage distances of DC polluted insulators. Based on the test results of insulator strings of 5 - 23 units, there are linear relationship between the 50% DC flashover voltages and string length. The experimental results show that the pollution flashover performances of various types of insulators are different, and that the pollution degree exponents of polluted insulators are affected ainsulator materials and shapes, whose values are 0.3 to 0.36. Under the same pollution degree, the pollution performances of glass insulators have advantage of those of porcelain insulators with the same configuration and the flashover voltage gradient along creepage distance and valid creepage distances of glass insulators are higher than those of porcelain insulators.
Keywords:insulator  direct current  flashover performance  flashover voltage gradient  valid creepage distance
点击此处可从《保鲜与加工》浏览原始摘要信息
点击此处可从《保鲜与加工》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号