首页 | 本学科首页   官方微博 | 高级检索  
     检索      

Voltage and Reactive Power Optimization of Main Electric Power Network in Chongqing
作者姓名:CHEN Gang  WU Ying-xi  ZHANG Ji-hong  LIU Shao-ting
摘    要:Based on the reactive surplus of Chongqing 220 kV main electric power network under low water and low load, and on state of higher system voltage, a thorough research is done on voltage and reactive power of the system power network by means of calculation,analysis and experiments. A main network calculating equivalence model of power network in Chongqing is constructed. And reactive power optimizing calculation is figured out on the Chongqing power network on condition that the loss minimum of the active power network is object function. Several optimizing compensatory schemes are put forward. Based on the calculation result and the analysis of all schemes, the most reasonable and feasible optimizing scheme could be achieved. Meanwhile, the feasibility that the system voltage could be adjusted when generator operating under excitation was demonstrated. According to the experience of under-excitation operation of the same type units , it decreases the system voltage, improves Chongqing power network running performance, and strengthens the coordination and stabilization of system.

关 键 词:Chongqing  power  network  voltage  reactive  power  optimization
修稿时间:2003/3/18 0:00:00

Voltage and Reactive Power Optimization of Main Electric Power Network in Chongqing
CHEN Gang,WU Ying-xi,ZHANG Ji-hong,LIU Shao-ting.Voltage and Reactive Power Optimization of Main Electric Power Network in Chongqing[J].Storage & Process,2003(7):66-69.
Authors:CHEN Gang  WU Ying-xi  ZHANG Ji-hong  LIU Shao-ting
Abstract:Based on the reactive surplus of Chongqing 220 kV main electric power network under low water and low load, and on state of higher system voltage, a thorough research is done on voltage and reactive power of the system power network by means of calculation,analysis and experiments. A main network calculating equivalence model of power network in Chongqing is constructed. And reactive power optimizing calculation is figured out on the Chongqing power network on condition that the loss minimum of the active power network is object function. Several optimizing compensatory schemes are put forward. Based on the calculation result and the analysis of all schemes, the most reasonable and feasible optimizing scheme could be achieved. Meanwhile, the feasibility that the system voltage could be adjusted when generator operating under excitation was demonstrated. According to the experience of under-excitation operation of the same type units , it decreases the system voltage, improves Chongqing power network running performance, and strengthens the coordination and stabilization of system.
Keywords:Chongqing power network  voltage  reactive power optimization
点击此处可从《保鲜与加工》浏览原始摘要信息
点击此处可从《保鲜与加工》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号