摘    要:通过用电炉加热消解法测定水中总磷,研究表明:该方法在0.08~1.20mg/L范围内线性良好,当取样体积为8.0mL时,方法检出限为0.006mg/L,标准溶液平行测定的RSD≤0.06%,水样加标回收率为97.8%~103%。

关 键 词:电炉消解  总磷  测定

Determination of Total Phosphorus in Water by Electric Furnace Heating Digestion
Chao Jun,Ji Yexin,Fan Huan,Yin Li,Wang Liangwen,Lu Jinsong.Determination of Total Phosphorus in Water by Electric Furnace Heating Digestion[J].LVSE DASHIJIU,2012(2):123-124.
Authors:Chao Jun  Ji Yexin  Fan Huan  Yin Li  Wang Liangwen  Lu Jinsong
Institution:(Shanghai ChongMing Environmental Monitoring Station,Shanghai 202150,China)
Abstract:This paper determines the total phosphorus in water by electric furnace heating digestion.A good linearity of the method is obtained in range from 0.08mg/L to 1.20mg/L.When the sampling volume is 8.0 mL,the detection limits is 0.006mg/L,RSD of parallel standard ≤0.06%,and the spiked recoveries of water sample is from 97.8% to 103%.