首页 | 本学科首页   官方微博 | 高级检索  
     


Effect of pressure support ventilation during weaning on ventilation and oxygenation indices in healthy horses recovering from general anesthesia
Authors:Keila K Ida  Denise T Fantoni  Maria TMR Souto  Denise A Otsuki  André LV Zoppa  Luis CLC Silva  Aline M Ambrósio
Affiliation:1. Departamento de Cirurgia, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, São Paulo, Brazil;2. Laboratório de Investigação Médica LIM‐08, Anestesiologia, Faculdade de Medicina, Universidade de São Paulo, São Paulo, Brazil
Abstract:
ObjectiveTo determine if pressure support ventilation (PSV) weaning from general anesthesia affects ventilation or oxygenation in horses.Study designProspective randomized clinical study.AnimalsTwenty client‐owned healthy horses aged 5 ± 2 years, weighing 456 ± 90 kg.MethodsIn the control group (CG; n = 10) weaning was performed by a gradual decrease in respiratory rate (fR) and in the PSV group (PSVG; n = 10) by a gradual decrease in fR with PSV. The effect of weaning was considered suboptimal if PaCO2 > 50 mmHg, arterial pH < 7.35 plus PaCO2 > 50 mmHg or PaO2 < 60 mmHg were observed at any time after disconnection from the ventilator until 30 minutes after the horse stood. Threshold values for each index were established and the predictive power of these values was tested.ResultsPressure support ventilation group (PSVG) had (mean ± SD) pH 7.36 ± 0.02 and PaCO2 41 ± 3 mmHg at weaning and the average lowest PaO2 69 ± 6 mmHg was observed 15 minutes post weaning. The CG had pH 7.32 ± 0.02 and PaCO2 57 ± 6 mmHg at weaning and the average lowest PaO2 48 ± 5 mmHg at 15 minutes post weaning. No accuracy in predicting weaning effect was observed for fR (p = 0.3474), minute volume (p = 0.1153), SaO2 (p = 0.1737) and PaO2/PAO2 (p = 0.1529). A high accuracy in predicting an optimal effect of weaning was observed for VT > 10 L (p = 0.0001), fR/VT ratio ≤ 0.60 breaths minute?1 L?1 (p = 0.0001), VT/bodyweight > 18.5 mL kg?1 (p = 0.0001) and PaO2/FiO2 > 298 (p = 0.0002) at weaning. A high accuracy in predicting a suboptimal effect of weaning was observed for VT < 10 L (p = 0.0001), fR/VT ratio ≥ 0.60 breaths minute?1 L?1 (p = 0.0001) and Pe′CO2 ≥ 38 mmHg (p = 0.0001) at weaning.Conclusions and clinical relevancePressure support ventilation (PSV) weaning had a better respiratory outcome. A higher VT, VT/body weight, PaO2/FiO2 ratio and a lower fR/VT ratio and Pe′CO2 were accurate in predicting the effect of weaning in healthy horses recovering from general anesthesia.
Keywords:horse  mechanical ventilation  pressure support ventilation  recovery from anesthesia  weaning outcome
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号