首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Evaluation of electrical nerve stimulation for epidural catheter positioning in the dog
Authors:Fernando L Garcia‐Pereira  Robert Sanders  Andre C Shih  Ioana M Sonea  Joseph G Hauptman
Institution:1. Department of Small Animal Clinical Sciences, College of Veterinary Medicine, Michigan State University, , East Lansing, MI, USA;2. Department of Large Animal Clinical Sciences, College of Veterinary Medicine, University of Florida, , Gainsville, FL, USA;3. Department of Pathobiology and Diagnostic Investigation, College of Veterinary Medicine, Michigan State University, , East Lansing, MI, USA
Abstract:ObjectiveTo evaluate the accuracy of epidural catheter placement at different levels of the spinal cord guided solely by electrical nerve stimulation and resultant segmental muscle contraction.Study designProspective, experiment.AnimalsSix male and two female Beagles, age (1 ± 0.17 years) and weight (12.9 ± 1.1 kg).MethodsAnimals were anesthetized with propofol and maintained with isoflurane. An insulated epidural needle was used to reach the lumbosacral epidural space. A Tsui epidural catheter was inserted and connected to a nerve stimulator (1.0 mA, 0.1 ms, 2 Hz) to assess positioning of the tip at specific spinal cord segments. The catheter was advanced to three different levels of the spinal cord: lumbar (L2–L5), thoracic (T5–T10) and cervical (C4–C6). Subcutaneous needles were previously placed at these spinal levels and the catheter was advanced to match the needle location, guided only by corresponding muscle contractions. Catheter position was verified by fluoroscopy. If catheter tip and needle were at the same vertebral body a score of zero was assigned. When catheter tip was cranial or caudal to the needle, positive or negative numbers, respectively, corresponding to the number of vertebrae between them, were assigned. The mean and standard deviation of the number of vertebrae between catheter tip and needle were calculated to assess accuracy. Results are given as mean ± SD.ResultsThe catheter position in relation to the needle was within 0.3 ± 2.0 vertebral bodies. Positive predictive values (PPV) were 57%, 83% and 71% for lumbar, thoracic and cervical regions respectively. Overall PPV was 70%. No significant difference in PPV among regions was found.Conclusion and clinical relevancePlacement of an epidural catheter at specific spinal levels using electrical nerve stimulation was feasible without radiographic assistance in dogs. Two vertebral bodies difference from the target site may be clinically acceptable when performing segmental epidural regional anesthesia.
Keywords:epidural anesthesia  epidural catheter  nerve stimulation
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号