Abstract: | The difference between the CB and Best Foods methods in extracting aflatoxins from peanut products has been studied. The CB method yields 60, 121, 35, and 22% higher results for aflatoxins B1, B2, G1, and G2, respectively for 4 samples of peanut meal and 6 samples of peanut butter studied. Both reverse phase liquid chromatography and thin layer chromatography were used to quantitate the extracted aflatoxins. |