首页 | 本学科首页   官方微博 | 高级检索  
     检索      

PD Online Measurement of Transformers with Wide Frequency Band System and the Noise Eliminating Method by Cascaded IIR Lattice Notch Digital Filter
作者姓名:LI Jian  WANG You-yuan  DU Lin  YANG Yang  NING Jia-xin
摘    要:The frequency band of conventional partial discharge (PD) measurement systems is selected just within several ten kilohertz. With the development of computer and digital signal processing techniques, wide frequency band (WFB) measurement systems have been used to detect PD in electrical equipment for its higher sensitivity. Nevertheless, the WFB measurement systems are easy suffered from the interference of strong field electromagnetism noises. A set of PD online monitoring system with frequency band from 50 kHz to 1 megahertz used for transformer is developed, in which pre-processing device and cascaded 2nd order IIR lattice notch digital filter are mainly used to suppress periodic narrow-band interference. With analysis of field monitored signal at a 220 kV substation, it is shown that the monitoring system not only can detect and extract the discharge pulse signal effectively, but also has the powerful capability of suppressing interference.

关 键 词:transformer    partial  discharge    wide  frequency  band  measurement    lattice  notch  digital  filter
收稿时间:2005/4/20 0:00:00
修稿时间:2005/4/20 0:00:00

PD Online Measurement of Transformers with Wide Frequency Band System and the Noise Eliminating Method by Cascaded IIR Lattice Notch Digital Filter
LI Jian,WANG You-yuan,DU Lin,YANG Yang,NING Jia-xin.PD Online Measurement of Transformers with Wide Frequency Band System and the Noise Eliminating Method by Cascaded IIR Lattice Notch Digital Filter[J].Storage & Process,2005(8):22.
Authors:LI Jian  WANG You-yuan  DU Lin  YANG Yang  NING Jia-xin
Abstract:The frequency band of conventional partial discharge (PD) measurement systems is selected just within several ten kilohertz. With the development of computer and digital signal processing techniques, wide frequency band (WFB) measurement systems have been used to detect PD in electrical equipment for its higher sensitivity. Nevertheless, the WFB measurement systems are easy suffered from the interference of strong field electromagnetism noises. A set of PD online monitoring system with frequency band from 50 kHz to 1 megahertz used for transformer is developed, in which pre-processing device and cascaded 2nd order IIR lattice notch digital filter are mainly used to suppress periodic narrow-band interference. With analysis of field monitored signal at a 220 kV substation, it is shown that the monitoring system not only can detect and extract the discharge pulse signal effectively, but also has the powerful capability of suppressing interference.
Keywords:transformer  partial discharge  wide frequency band measurement  lattice notch digital filter
点击此处可从《保鲜与加工》浏览原始摘要信息
点击此处可从《保鲜与加工》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号