首页 | 本学科首页   官方微博 | 高级检索  
     检索      


RESEARCH PAPER: Ultrasound‐guided nerve blocks of the pelvic limb in dogs
Authors:Yael Shilo  Peter J Pascoe  Derek Cissell  Eric G Johnson  Philip H Kass  Erik R Wisner
Institution:1. Veterinary Medical Teaching Hospital, School of Veterinary Medicine, University of California, Davis, CA, USA;2. Department of Surgical and Radiological Sciences, School of Veterinary Medicine, University of California, Davis, CA, USA;3. Department of Population Health and Reproduction, School of Veterinary Medicine, University of California, Davis, CA, USA
Abstract:ObjectivesTo evaluate the efficacy of ultrasound‐guidance in nerve blockade of the sciatic and saphenous nerves in dogs and to determine if this technique could allow lower anaesthetic doses to be used with predictable onset and duration of effect.Study designProspective randomized (for dose and leg) blinded experimental crossover trial with 10 day washout period.AnimalsSix healthy female Hound dogs aged 12.3 ± 0.5 (mean ± SD) months and weighing 18.7 ± 0.8 (mean ± SD) kg.MethodsAn ultrasound‐guided, perineural injection was used with saline at 0.2 mL kg?1 (Sal) or bupivacaine 0.5% at 0.05 (low dose; LD), 0.1 (medium dose; MD), or 0.2 (high dose; HD) mL kg?1, divided 2/3 at the sciatic nerve and 1/3 at the saphenous nerve. Blocks were performed using dexmedetomidine sedation with atipamezole reversal immediately after completion of the injections. Motor/proprioceptive and sensory functions were scored using a 0–8 and a 0–2 scale, respectively. Clinically relevant blocks were defined as a motor score ≥2 and sensory score ≥1. Nonparametric methods were used for statistical analysis.ResultsNo adverse effects were noted. There was a significant difference between the treatments with bupivacaine and the saline control, but not between the three bupivacaine treatments. Success rates of clinically relevant sciatic and saphenous blocks were both 67% (CI 95% 0.22–0.96). Onset and duration of the blocks were variable; 20–160 and 20–540 minutes, respectively.Conclusion and clinical relevanceNone of the bupivacaine doses was significantly superior, though there was a tendency for a better block with the high bupivacaine dose. Either the technique or the doses used need further modification before this method will be useful in clinical practice.
Keywords:bupivacaine  dog  regional anaesthesia  sciatic nerve block  saphenous nerve block  ultrasound guidance
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号