首页 | 本学科首页   官方微博 | 高级检索  
     检索      


RESEARCH PAPER: Comparison of an implantable telemetry device and an oscillometric monitor for measurement of blood pressure in anaesthetized and unrestrained green iguanas (Iguana iguana)
Authors:Sathya K Chinnadurai  Ryan DeVoe  Amie Koenig  Nadia Gadsen  Amanda Ardente  Stephen J Divers
Institution:1. Department of Clinical Sciences and Environmental Medicine Consortium, College of Veterinary Medicine, North Carolina State University, Raleigh, NC, USA;2. North Carolina Zoological Park, Asheboro, NC, USA;3. Department of Small Animal Medicine and Surgery, College of Veterinary Medicine, University of Georgia, Athens, GA, USA
Abstract:Objective The objective of this study was to compare an implanted direct blood pressure monitor and a non‐invasive oscillometric unit for use in anesthetized and awake green iguanas. Study design Prospective experimental trial. Animals Four male and four female adult green iguanas (Iguana iguana) weighing 1833 ± 534 g. Methods For each animal, the carotid artery was surgically exposed and the catheter tip of the pressure transducer was placed in the aortic arch. Non‐invasive blood pressure was measured using a cuff over the left femoral region. Pulse rate, respiratory rate and arterial blood pressure (ABP) measurements were taken every 5 minutes. Direct ABP measurements consisted of recording numerical values and graphic output. Simultaneous direct and indirect measurements were repeated in awake animals. Results The oscillometric device failed to provide a reading in over 80% of attempts, and failed to provide readings that correlated with direct measurements. The implanted direct transducer was capable of detecting blood pressures throughout all ABP ranges examined. Conclusions The implantable transducer was a reliable means of determining blood pressure in this study, while the oscillometric device was unreliable and often failed to provide any reading. Clinical relevance We do not recommend using the oscillometric device as described in a research or clinical setting for green iguanas. The advantages of an implantable device include the ability to monitor awake and anesthetized subjects remotely and continuously. These monitors are small, biocompatible and function across a wide range of ABP.
Keywords:anesthesia  arterial blood pressure  cardiovascular  Iguana iguana  oscillometric  telemetry
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号