摘    要:目的]探寻有效、简便、准确的水中六价铬含量测定方法。方法]对标准样品和实际样品进行对比分析,验证SKALAR连续流动分析仪测定水中六价铬含量的准确性和精密性。结果]该方法测定水中六价铬含量的线性关系、灵敏度、准确度、精密度和加标回收率等指标均可满足试验测定要求。结论]该方法快速、准确、可靠,是测定水中六价铬含量的有效方法。

关 键 词:六价铬  水质监测  连续流动分析仪

The Determination of Hexavalent Chromium in Water with SKALAR Automatic Continuous Flow Analyzer
Abstract:Objective] To find effective, simply and accurate determination method of hexavalent chromium content in the water.Method] Via comparative analysis between standard samples and realistic samples, the measurement precision and accuracy of SKALAR automatic continuous flow analyzer to hexavalent chromium content in the water were verified.Result] When using this method to determine hexavalent chromium in water, linear relationship, sensitivity, accuracy, precision and addition standard recovery all met the requirements of experimental determination. Conclusion] The method was rapid, accurate and reliable.It provided an effective method to determine the content of hexavalent chromium in water.
Keywords:Hexavalent chromium  Water quality monitoring  Continuous flow analyzer