首页 | 本学科首页   官方微博 | 高级检索  
     检索      

常规变电所无人值班改造中问题的分析及建议
引用本文:李庆春.常规变电所无人值班改造中问题的分析及建议[J].沈阳农业大学学报,1999,30(2):147-149.
作者姓名:李庆春
作者单位:沈阳农业大学农工学院!辽宁沈阳110161
摘    要:农村常规变电所正在进行无人值班改造,已改造过的变电所运行并不十分理想,本文针对遥测精度,遥信误报、遥控可靠性方面存在的问题进行分析,并提出改进建议。

关 键 词:精度  遥测  遥控  遥信

Analyses and Proposals for the Problems of Reforming the Conventional Substation to Unattended Substation
LI Qing-chun.Analyses and Proposals for the Problems of Reforming the Conventional Substation to Unattended Substation[J].Journal of Shenyang Agricultural University,1999,30(2):147-149.
Authors:LI Qing-chun
Abstract:Reforming in conventional substation to unattended substation is carrying out in countryside. But therunning of the reformed transformer station is not perfect. In this paper, the problems of distant reading accuracy,distant signal ac error, the reliability of distant control were analysed and some proposals for improvement wereprovided.
Keywords:Accuracy  distant reading  remote control  distant signal  