首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Use of a hybrid external skeletal fixator for repair of a periarticular tibial fracture in a Patagonian cavy
Authors:Joyner Priscilla H  Rochat Mark C  Hoover John P
Institution:Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Oklahoma State University, Stillwater, OK 74078, USA.
Abstract:An 8-week-old female Patagonian cavy was examined because of acute right hind limb lameness; radiography revealed a moderately displaced, comminuted fracture of the proximal third of the tibia. The fracture was stabilized with a hybrid external skeletal fixator. Two Kirschner wires were placed in the main proximal fragment, parallel to the tibial plateau and at right angles to each other. These wires were connected to a partial circular external fixator ring. Three half pins were placed in the distal fragment, and a straight connecting rod positioned on the medial side of the limb was connected to these pins and the fixator ring. A second connecting rod was positioned on the craniomedial side of the limb and was connected to the fixator ring and a fourth half pin in the distal fragment. The fracture healed without complications, and the fixator was removed 3 weeks after surgery. Hybrid external skeletal fixators combine the benefits of circular and linear external skeletal fixation methods, enabling rigid fixation of periarticular long bone fractures without adversely affecting mobility of the adjacent joint.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏