首页 | 本学科首页   官方微博 | 高级检索  
     检索      

复混肥料中磷和钾的超声波-ICP-OES快速测定法
引用本文:高善民,周丕生.复混肥料中磷和钾的超声波-ICP-OES快速测定法[J].上海交通大学学报(农业科学版),2013,31(3):39-43.
作者姓名:高善民  周丕生
作者单位:1. 上海市农业技术推广服务中心,上海,201103
2. 上海交通大学农业与生物学院,上海,201101
摘    要:采用超声波快速样品前处理技术,结合ICP-OES(电感耦合等离子体发射光谱仪),建立复混肥料中磷和钾快速测定法.通过高、中、低浓度复混肥料的平行测定和回收率验证,该方法的磷极差为0.14%~0.17%,RSD为0.76%~1.06%,回收率为98.8%~103.27%;钾极差为0.24%~0.34%,RSD为0.78%~1.23%,回收率为98.2%~102.4%;与国标法的绝对差值:磷为0.05%~0.19%,钾为0.07%~0.29%.结果表明,该方法具有较高的精密度和准确度,符合国标GB/T8573-2010和GB/T8574-2010对复混肥料样品平行测定和不同实验室测定结果的允许差要求.本方法简便、准确、快速,特别适合于大批量复混肥料样品中磷和钾的测定.

关 键 词:超声波提取  ICP-OES  复混肥料    
收稿时间:2012/10/24 0:00:00

Rapid Determination of Phosphorus and Potassium in Compound Fertilizer by Ultrasonic Extraction and ICP-OES
GAO Shan-min and ZHOU Pi-sheng.Rapid Determination of Phosphorus and Potassium in Compound Fertilizer by Ultrasonic Extraction and ICP-OES[J].Journal of Shanghai Jiaotong University (Agricultural Science),2013,31(3):39-43.
Authors:GAO Shan-min and ZHOU Pi-sheng
Institution:Shanghai Agro-Technology Extension Service Center,Shanghai 201103,China and School of Agriculture and Biology,Shanghai Jiaotong University,Shanghai 201101,China
Abstract:Ultrasonic extraction and ICP-OES (inductively coupled plasma-optical emission spectrometer) method for the rapid determination of the content of phosphorus and potassium in compound fertilizers was established.The method was applied to parallel determination and recovery tests in high,medium,low nutrient concentration of the 3 compound fertilizer samples.The maxium deviation,RSD and recovery rate of phosphorus determination in the tests were 0.14%~0.17%,0.76%~1.06% and 98.8%~103.27% respectively.And the maxium deviation,RSD and recovery rate of potassium determination in the tests were 0.24%~0.34%,0.78%~1.23% and 98.2%~102.4% respectively.Compared with national standard method,the absolute different values of phosphorus and potassium were 0.05%~0.19% and 0.07%~0.29%,respectively.The results indicated that the method has higher precision and accuracy.It could meet the requirement of the limited deviations of GB/T8573-2010 and GB/T8574-2010 for parallel determination in same or different laboratories.The method is suitable for the determination of phosphorus and potassium in large quantities of compound fertilizer samples.
Keywords:ultrasonic extraction  ICP-OES  compound fertilizer  phosphorus  potassium
本文献已被 万方数据 等数据库收录!
点击此处可从《上海交通大学学报(农业科学版)》浏览原始摘要信息
点击此处可从《上海交通大学学报(农业科学版)》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号