首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Effects of two fractions of inspired oxygen on lung aeration and gas exchange in cats under inhalant anaesthesia
Authors:Staffieri Francesco  De Monte Valentina  De Marzo Carmelinda  Grasso Salvatore  Crovace Antonio
Institution:Dipartimento dell'Emergenza e dei Trapianti di Organi (DETO), Sezione di Chirurgia Veterinaria, Facoltà di Medicina Veterinaria, Università degli Studi di Bari, Valenzano (Bari), Italy. f.staffieri@veterinaria.uniba.it
Abstract:ObjectiveTo compare the effects of two fractions of inspired oxygen (FiO2) (0.4 and 1) on lung aeration and gas exchange during general anaesthesia in cats.Study designRandomized, blinded, controlled study.AnimalsThirty healthy, mixed breed, client owned female cats.Materials and methodsCats were premedicated intramuscularly with acepromazine (0.03 mg kg?1) and medetomidine (0.015 mg kg?1). Anaesthesia was induced with propofol (5 mg kg?1) and, after orotracheal intubation, maintained with isoflurane carried by either 100% oxygen (G100, n = 15) or an oxygen-air mixture with 40% oxygen (G40, n = 15). All cats were placed in dorsal recumbency and breathed spontaneously throughout the entire procedure. Following surgery (ovariectomy), a spiral computed tomography (CT) of the thorax was performed, arterial oxygen (PaO2) and carbon dioxide (PaCO2) tensions were measured and alveolar-arterial gradient of oxygen P(A-a)O2] calculated. The CT images were analysed for lung aeration by the analysis of radiograph attenuations (Hounsfield units, HU), according to the following classification: hyperinflated area (-1000 to -900 HU), normally aerated area (-900 to -500 HU), poorly aerated area (-500 to -100 HU) and non-aerated area (-100 to +100 HU). The groups were compared using one-way anova.ResultsCompared to G100, the normally-aerated lung area was significantly greater and the poorly-aerated and non-aerated areas were significantly smaller in G40. PaCO2 was similar in both groups. PaO2 and P(A-a)O2 were significantly higher in G100. In both groups, pulmonary atelectasis developed preferentially in the caudal lung fields.ConclusionIn cats anaesthetised with isoflurane, the administration of an FiO2 of >0.9 significantly impaired lung aeration and gas exchange as compared to an FiO2 of 0.4.Clinical relevanceAn FiO2 of 0.4 may better preserve lung aeration and gas exchange in anaesthetised spontaneously breathing cats but monitoring is essential to ensure oxygenation is adequate.
Keywords:cats  computed tomography  gas exchange  general anaesthesia  pulmonary atelectasis
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号