首页 | 本学科首页   官方微博 | 高级检索  
     检索      

OPTIMAL ACTIVE POWER ADJUSTMEMT OF LARGE HYBRID AC/DC SYSTEMS AFTER OUTAGE CONTINGENCIES WITH THE APPLICATION IN RELIABILITY EVALUATION
作者姓名:Ran  Li  Ren  Zhen  Jiang  Zejia
作者单位:Ran Li Ren Zhen Jiang Zejia
摘    要:An optimal active power adjustment model is deve in this paper for hybrid AC/DC systems after outage contingencies. The objective of the model is to minimize the rejection of load when some elements are out of service, with adjustment strategy approaching practical system operation. A large number of outage contingencies are simulated when the Monte-Carlo Method is emyloyed to evaluate the system reliability, requiring fast calculation of each simulation. The model and computer method proposed in this paper satisfy such a requirment because of the application of concentric relaxation, recursive branch constraint treatment in linear programming and a direct method for B-1 matrix modification. This paper is concerned with the simplified steady state conditions of the system based on DC load-flow, which implies the reliability indices calculated are the measures about static loss of load. The results for a 14-bus hybrid AC/DC system are given.

关 键 词:Hybrid  AC/DC  system    outage  contingencies    active  power  adjustment    reliability.

OPTIMAL ACTIVE POWER ADJUSTMEMT OF LARGE HYBRID AC/DC SYSTEMS AFTER OUTAGE CONTINGENCIES WITH THE APPLICATION IN RELIABILITY EVALUATION
Ran Li Ren Zhen Jiang Zejia.OPTIMAL ACTIVE POWER ADJUSTMEMT OF LARGE HYBRID AC/DC SYSTEMS AFTER OUTAGE CONTINGENCIES WITH THE APPLICATION IN RELIABILITY EVALUATION[J].Storage & Process,1988(6).
Authors:Ran Li Ren Zhen Jiang Zejia
Institution:Ran Li Ren Zhen Jiang Zejia
Abstract:An optimal active power adjustment model is deve in this paper for hybrid AC/DC systems after outage contingencies. The objective of the model is to minimize the rejection of load when some elements are out of service, with adjustment strategy approaching practical system operation. A large number of outage contingencies are simulated when the Monte-Carlo Method is emyloyed to evaluate the system reliability, requiring fast calculation of each simulation. The model and computer method proposed in this paper satisfy such a requirment because of the application of concentric relaxation, recursive branch constraint treatment in linear programming and a direct method for B-1 matrix modification. This paper is concerned with the simplified steady state conditions of the system based on DC load-flow, which implies the reliability indices calculated are the measures about static loss of load. The results for a 14-bus hybrid AC/DC system are given.
Keywords:Hybrid AC/DC system  outage contingencies  active power adjustment  reliability  