Abstract:Abstract

A collaborative assay among three laboratories was made in order to compare both the ion (CEN. EN 13368‐2:2001 E. Determination of chelating agents in fertilizers by ion chromatography. Part 2: EDDHA and EDDHMA, 2001a) and the ion‐pair (Lucena, J.J.; Barak, P.; Hernandez‐Apaolaza, L. Isocratic ion‐pair high‐performance liquid chromatographic method for the determination of various iron(III) chelates. J. Chromatogr. A 1996, 727, 253–264) high performance liquid chromatography (HPLC) methods as well as the soluble and complexed Fe (CEN. EN 13366:2001 E. Treatment with a cation exchange resin for the determination of the chelated micronutrient content and of the chelated fraction of micronutrients, 2001b) methods. Fifteen and ten samples of commercial fertilizers of Fe‐EDDHA, Fe‐EDDHMA, respectively were analysed by three laboratories using these methods. No significant differences were observed between the results obtained for the Fe‐EDDHA content using the Lucena et al. or CEN method. The first method makes it possible to distinguish between the meso and DL‐racemic diasteroisomers of Fe‐o, o‐EDDHA. For the Fe‐EDDHMA formulations, the CEN method gives higher values than the ion‐pair method, since in the first one Fe‐EDDH4,6MA coelutes with FeEDDHMA. Also the CEN method does not makes it possible to distinguish between Fe‐EDDHMA and Fe‐EDDH5MA products. The variability among laboratories was larger for the CEN method than for the Lucena et al. method.
Keywords:Iron chelate  Fertilizer  Ion chromatography  Ion‐pair chromatography  HPLC