1.
The technique of cystocentesis in dogs and cats was studied. The indications and contraindications of this method are discussed, using illustrations. 相似文献
2.
Two cases of H.c.c. which occurred in winter 1987 in Vienna are described. Case one was a female Chow-Chow, 8 weeks of age, that died from the peracute form of the disease. The diagnosis was confirmed by histology and direct immunofluorescence. Case two, a 9-month old female Kuvacz, showed clinical signs of the subacute form of H.c.c. She was hospitalized and therapy was successful. The disease was diagnosed by the typical clinical signs and the raise of antibodies in paired serum samples. Etiology, clinical signs and immunology of H.c.c. are discussed. 相似文献
3.
4.
5.
6.
Objective To evaluate standing, percutaneous, ultrasound-guided, transthoracic liver biopsy in mares, and transabdominal, laparoscopically-guided, liver biopsy under general anaesthesia in foals, as techniques for obtaining tissue for assessment of copper status. The techniques were evaluated with respect to ease of use and effect on the animal.
Procedure Twenty of 24 Thoroughbred mares and 21 of their foals were biopsied. The animals were part of a larger study of the effect of copper supplementation on copper status and the prevalence of developmental orthopaedic disease. Livers were also collected from unrelated horses and sampled to investigate the variability in the distribution of copper in liver tissue.
Result The biopsy technique caused no lasting effect on the mares, but there was an increased risk of viscus penetration associated with taking multiple biopsy cores. The use of ultrasonography to scan the target area for the liver identified four cases that were not appropriate candidates for liver biopsy, because of large intestine being located in the biopsy area. In the foals there were no serious postoperative adverse effects, nor was there any evidence of problems caused by the procedure when the abdomen was examined post-mortem at 5 months of age. In livers collected to investigate the variability of copper concentration, copper appeared to be relatively evenly distributed through the liver.
Conclusion Standing, percutaneous, ultrasound-guided, transthoracic liver biopsy in mares, and transabdominal, laparoscopically-guided, liver biopsy under general anaesthesia in foals are convenient procedures for obtaining liver tissue for assessing copper status in horses. The use of ultrasound to identify liver tissue is recommended, especially in older mares. 相似文献
Procedure Twenty of 24 Thoroughbred mares and 21 of their foals were biopsied. The animals were part of a larger study of the effect of copper supplementation on copper status and the prevalence of developmental orthopaedic disease. Livers were also collected from unrelated horses and sampled to investigate the variability in the distribution of copper in liver tissue.
Result The biopsy technique caused no lasting effect on the mares, but there was an increased risk of viscus penetration associated with taking multiple biopsy cores. The use of ultrasonography to scan the target area for the liver identified four cases that were not appropriate candidates for liver biopsy, because of large intestine being located in the biopsy area. In the foals there were no serious postoperative adverse effects, nor was there any evidence of problems caused by the procedure when the abdomen was examined post-mortem at 5 months of age. In livers collected to investigate the variability of copper concentration, copper appeared to be relatively evenly distributed through the liver.
Conclusion Standing, percutaneous, ultrasound-guided, transthoracic liver biopsy in mares, and transabdominal, laparoscopically-guided, liver biopsy under general anaesthesia in foals are convenient procedures for obtaining liver tissue for assessing copper status in horses. The use of ultrasound to identify liver tissue is recommended, especially in older mares. 相似文献
7.
8.
9.
Evaluation of reticulocyte hemoglobin content (RET‐He) in the diagnosis of iron‐deficient erythropoiesis in dogs 下载免费PDF全文
Jannika Fuchs Andreas Moritz Esther Grußendorf Jörg Lechner Felix Neuerer Rafael Nickel Thomas Rieker Claudia Schwedes Dennis B. DeNicola James Russell Natali Bauer 《Veterinary clinical pathology / American Society for Veterinary Clinical Pathology》2017,46(4):558-568
Background
Reticulocyte hemoglobin content provided by the Siemens ADVIA (CHr) is an established marker of iron deficiency. The IDEXX ProCyte Dx hematology analyzer now provides a similar variable, reticulocyte hemoglobin equivalent (RET‐He).Objectives
The objective was to evaluate RET‐He and its diagnostic utility in dogs, and to calculate a cutoff value for diagnosing iron‐deficient erythropoiesis (IDE). Furthermore, the prevalence of RET‐He values below this cutoff value was established.Methods
One hundred and seventy‐one CBCs of healthy dogs were used to establish a RI. Stability of RET‐He was evaluated by repeated measurements over 48 hours (n = 10). The 25‐run coefficient of variation (CV) was calculated, and correlation and bias between measurements of RET‐He and CHr were assessed (n = 190). A cutoff value for diagnosing IDE was calculated. The utility of RET‐He in the detection of IDE was evaluated in 123 dogs. The prevalence of low RET‐He values was assessed retrospectively in a multicenter study (2012–2014) under participation of 7 veterinary clinics.Results
Reticulocyte hemoglobin equivalent with an RI of 22.2 to 28.6 pg was statistically stable over 48 hours (P = .10). The CV was 1.8%. A fair correlation (ρ = 0.74) between RET‐He and CHr with a small bias of ?0.6 pg was found. The cutoff value for diagnosing IDE was 20.9 pg (sensitivity: 85%; specificity: 99%). The prevalence of RET‐He values below 20.9 pg was 10.3% (1084/10,553 dogs).Conclusions
RET‐He on the ProCyte Dx is a precise screening tool in dogs to detect iron‐deficient erythropoiesis. 相似文献10.