全文获取类型
收费全文 | 122篇 |
免费 | 17篇 |
专业分类
林业 | 1篇 |
1篇 | |
综合类 | 11篇 |
农作物 | 1篇 |
畜牧兽医 | 124篇 |
植物保护 | 1篇 |
出版年
2020年 | 5篇 |
2019年 | 5篇 |
2018年 | 6篇 |
2017年 | 3篇 |
2016年 | 8篇 |
2015年 | 2篇 |
2014年 | 5篇 |
2013年 | 11篇 |
2012年 | 4篇 |
2011年 | 6篇 |
2010年 | 4篇 |
2009年 | 6篇 |
2008年 | 8篇 |
2007年 | 7篇 |
2006年 | 6篇 |
2005年 | 10篇 |
2004年 | 8篇 |
2003年 | 3篇 |
2002年 | 4篇 |
2000年 | 8篇 |
1999年 | 4篇 |
1998年 | 5篇 |
1996年 | 5篇 |
1994年 | 1篇 |
1993年 | 2篇 |
1974年 | 1篇 |
1973年 | 1篇 |
1957年 | 1篇 |
排序方式: 共有139条查询结果,搜索用时 421 毫秒
1.
G Zamaratskaia J Babol A Madej EJ Squires K Lundström 《Reproduction in domestic animals》2004,39(3):168-172
This study describes the age-related variation in boar taint compounds, skatole and androstenone, and testosterone, oestradiol-17 beta (E17 beta), oestrone sulphate (ES), dehydroepiandrosterone sulphate (DHEAS), triiodothyronine (T(3)) and insulin-like growth factor-1 (IGF-1) in six boars. Three pairs of littermates of crossbred entire male pigs (from three Yorkshire x Duroc dams and one Hampshire sire) were included. Blood samples were taken at the age of 9-15 weeks and thereafter at weekly intervals from the age of 20-32 weeks. Plasma concentrations of skatole, androstenone, testosterone, E17 beta, ES, DHEAS, T(3) and IGF-1 were measured. We found that skatole levels in boars increased at the age around puberty after an increase in the levels of testicular steroids. Levels of skatole were not associated with the levels of sex steroids, T(3) and IGF-1. However, the increased level of testicular steroids is probably the underlying factor needed for high skatole levels to occur although the specific mechanism leading to increased skatole levels remains unknown. 相似文献
2.
3.
4.
OBJECTIVE: To identify factors affecting radial alignment after oblique corrective osteotomy stabilized with a type II external fixator and to evaluate the results of this treatment for antebrachial growth deformities. STUDY DESIGN: Retrospective study SAMPLE POPULATION: Twenty-eight dogs with unilateral antebrachial growth deformities treated with acute corrective osteotomy stabilized with a type II external fixator. METHODS: Medical records and preoperative and postoperative radiographs of the affected and contralateral limb were reviewed. Cause of deformity, age, weight, and gender were recorded. Radial length, varus/valgus angulation, and cranial/caudal angulation were measured from radiographs of the treated and contralateral limbs. Preoperative and postoperative angulation and length discrepancy were compared between affected and contralateral limbs. RESULTS: Correction of varus/valgus angle discrepancy was achieved by using acute corrective osteotomy stabilized with type II external skeletal fixation. No significant change was noted for correction of cranial/caudal angle discrepancy or length discrepancy between the affected and control limb. CLINICAL RELEVANCE: Varus/valgus angle deformities can be treated successfully with type III external fixation after oblique corrective osteotomy. Patients with significant length or cranial/caudal angle discrepancies or both that negatively impact function may require the use of hinged circular fixators or other dynamic techniques to achieve adequate correction. 相似文献
5.
Coolman BR Ehrhart N Marretta SM 《Journal of the American Animal Hospital Association》2000,36(6):542-547
A technique was developed for closure of gastrotomy and enterotomy incisions using disposable skin staples. The technique was used successfully in three dogs with gastrointestinal linear foreign bodies that required a gastrotomy and one or more enterotomies. The method allows for secure closure of gastrointestinal incisions and minimizes the surgical time in patients requiring multiple gastrointestinal incisions. 相似文献
6.
Novotny MJ Krautmann MJ Ehrhart JC Godin CS Evans EI McCall JW Sun F Rowan TG Jernigan AD 《Veterinary parasitology》2000,91(3-4):377-391
Selamectin is a broad-spectrum avermectin endectocide for treatment and control of canine parasites. The objective of these studies was to evaluate the clinical safety of selamectin for topical use in dogs 6 weeks of age and older, including breeding animals, avermectin-sensitive Collies, and heartworm-positive animals. The margin of safety was evaluated in Beagles, which were 6 weeks old at study initiation. Reproductive, heartworm-positive, and oral safety studies were conducted in mature Beagles. Safety in Collies was evaluated in avermectin-sensitive, adult rough-coated Collies. Studies were designed to measure the safety of selamectin at the recommended dosage range of 6-12mgkg(-1) of body weight. Endpoints included clinical examinations, clinical pathology, gross and microscopic pathology, and reproductive indices. Selected variables in the margin of safety and reproductive safety studies were subjected to statistical analyses. Pups received large doses of selamectin at the beginning of the margin of safety study when they were 6 weeks of age and at their lowest body weight, yet displayed no clinical or pathologic evidence of toxicosis. Similarly, selamectin had no adverse effects on reproduction in adult male and female dogs. There were no adverse effects in avermectin-sensitive Collies or in heartworm-positive dogs. Oral administration of the topical formulation caused no adverse effects. Selamectin is safe for topical use on dogs at the recommended minimum dosage of 6mgkg(-1) (6-12mgkg(-1)) monthly starting at 6 weeks of age, and including dogs of reproducing age, avermectin-sensitive Collies, and heartworm-positive dogs. 相似文献
7.
Immunohistochemical Expression of Growth Factors in the Follicular Wall of Normal and Cystic Ovaries of Sows 下载免费PDF全文
FJF Sant'Ana JL Reis Junior GR Blume EJ Gimeno F Rey HH Ortega 《Reproduction in domestic animals》2015,50(2):327-332
The expression of growth factors was evaluated immunohistochemically in normal and cystic ovaries of sows. The immunohistochemically stained area (IHCSA) was quantified by image analysis to analyse the expression of these proteins in the follicular wall of secondary, tertiary and cystic follicles. IGF‐I immunoreactivity was strong in the granulosa cell layer (GC), moderate in the theca interna (TI) and mild in the theca externa (TE) of the normal follicles. There was severe reduction of the labelling to IGF‐I in the GC of the follicular and luteinized cysts. In the normal follicles, the reactivity for IGF‐II was very similar to pattern noted in IGF‐I. There was reduction of the IHCSAs in the GC of the follicular and luteinized cysts, but the decrease was not significant. The staining of the IGF‐II in the TI and TE of the cysts was increased, in comparison with normal follicles. The IHCSAs for VEGF were higher in the GC and TE of the normal follicles in contrast to TI, but this difference was noted only in the tertiary follicle. The VEGF reactivity increased in the GC of the cysts, in relation to normal follicles. The results of the current study show that the formation of ovarian cysts in sows is associated with alterations in the immunohistochemical expression of some growth factors. 相似文献
8.
A 1.5-year-old female, intact, clinically healthy cat presented for a subcutaneous mass of the ventral abdomen. Surgical excision and microscopic examination of the mass were performed. Histologically, this was a discrete, unencapsulated, multilobular, expansile mass, which compressed the surrounding normal mammary tissue. Lobules were composed of tubuloacinar structures formed by atypical round to polygonal cells, which contained foamy to microvacuolated cytoplasm and variably sized, intracytoplasmic, distinct vacuoles causing nuclear peripheralization. Neoplastic cells demonstrated intense and diffuse immunoreactivity for cytokeratin and lacked immunoreactivity for vimentin. The vacuolar contents stained positively with Oil RedO and negatively with periodic acid-Schiff and Alcian blue stains. Histomorphologic, histochemical, and immunohistochemial analysis support a diagnosis of lipid-rich mammary carcinoma. This is the first report of a cat with a lipid-rich variant of mammary carcinoma. 相似文献
9.
The objective of this retrospective study was to describe signalment, clinical presentation, surgical treatment, outcome, histopathologic, and immunohistochemical characteristics of periocular peripheral nerve sheath tumor in a series of cats. Six cats with a histologic diagnosis of peripheral nerve sheath tumor of the eyelid and/or conjunctiva were identified from 3997 feline ocular histopathologic submissions to the Comparative Ocular Pathology Laboratory of Wisconsin between 1976 and 2002. Medical records were reviewed and data were collected for signalment, eye affected, location, duration, and history of tumor recurrence. Ancillary diagnostic tests, surgical approach, and histopathology were also described. Special stains and immunohistochemistry panels were performed on the tissue. Follow-up information was obtained through telecommunications with the owner and local veterinarian. The mean age of the cats was 8 years (range: 5-15 years). There was an equal distribution of males and females. Breeds represented were two Domestic Long-haired (DLH) cats, three Domestic Short-haired (DSH) cats, and one Manx. The right eye was affected in four cats and the left eye in two cats. The superior eyelid was affected in four cats, the superior conjunctiva in two cats, and the inferior eyelid in one cat. All of the cats that underwent surgical excision, cryoablation, or laser ablation had an average of three recurrences of the tumor. Four of six cats undergoing wide excision with enucleation, exenteration or rhomboid flap had no recurrence of the tumor. Histomorphologically, all of the tumors were of spindle cell type with five of six tumors showing histologic features of Antoni type B tissue. All six tumors stained positive for vimentin. Five of six tumors stained positive for S-100 and laminin. All six tumors were negative for smooth muscle actin. Definitive histologic diagnoses of spindle cell tumors can be difficult. The presence of Antoni A and B histologic patterns as well as immunohistochemical reactivity for vimentin, S-100, and laminin suggest a diagnosis of peripheral nerve sheath tumor. Our findings suggest that local aggressive recurrence is common and that wide surgical excision combined with enucleation or exenteration may be indicated. 相似文献
10.
Silbernagel JT Johnson AL Pijanowski GJ Ehrhart N Schaeffer DJ 《Veterinary surgery : VS》2004,33(2):173-179
OBJECTIVE: To evaluate and compare the mechanical properties of 4.5 narrow and 3.5 broad plating systems using their respective cortical and cancellous screws in unstable, central, and eccentric gap fracture models. STUDY DESIGN: Mechanical evaluation and comparison of 2 dynamic compression plate (DCP) systems. SAMPLE POPULATION: Eighteen cortical and 30 cancellous gapped fracture models. METHODS: DCP (4.5 mm narrow, 3.5 mm broad) with their respective cortical screws were applied to cortical bone density polyurethane foam blocks to construct center gap cortical fracture models that were tested in gap closing monotonic 4-point bending. DCP (4.5 mm narrow, 3.5 mm broad) with their respective cancellous screws were applied to cancellous bone density polyurethane foam blocks to construct eccentric gap cancellous fracture models. The cancellous constructs were tested in monotonic gap opening and gap closing cantilever bending and in cyclic axial loading. Univariate and multivariate repeated measures ANOVA were used to compare the maximum loads at failure of the 4.5 mm constructs and 3.5 mm constructs. RESULTS: The 4.5 mm narrow plating system withstood significantly higher loads at failure than the 3.5 mm broad plating system in 4-point bending (P<.0001) and gap opening cantilever bending (P<.0001). The 4.5 mm system failed in gap closing cantilever bending by plastic deformation of the plate, whereas the 3.5 mm system failed by screw pullout. There was no difference between the 2 systems in cyclic axial loading. CONCLUSION: Results indicate that the 4.5 mm narrow plating system has a mechanical advantage over the 3.5 mm broad plating system for stabilization of gapped fracture models. CLINICAL RELEVANCE: The 4.5 mm narrow plating system may be mechanically advantageous compared with the 3.5 mm broad plating system for stabilizing unreconstructed comminuted long bone fractures in large dogs. 相似文献