首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   25篇
  免费   2篇
畜牧兽医   27篇
  2018年   2篇
  2007年   1篇
  2006年   2篇
  2004年   1篇
  2003年   3篇
  2002年   1篇
  2001年   1篇
  2000年   2篇
  1999年   2篇
  1998年   3篇
  1997年   3篇
  1996年   4篇
  1994年   1篇
  1993年   1篇
排序方式: 共有27条查询结果,搜索用时 322 毫秒
1.
A one‐year‐old female cocker spaniel presented with a 6‐month history of persistent diarrhoea. Abdominal ultrasonographic examination revealed mild diffuse thickening of the intestinal wall coupled with mesenteric lymphadenopathy. A connection between the duodenum and the colon was observed during an endoscopic procedure and confirmed by computed tomography. Surgical resection of the communication allowed remission of the diarrhoea. Histology showed a normal duodenal epithelium and muscular layer. A duodenocolic fistula is an abnormal connection within the digestive tract, which in humans is usually considered a complication of a local pathological condition. Due to the absence of a predisposing cause and, in view of the dog's age and histological results, a congenital origin was suspected.  相似文献   
2.
The scintigraphically measured percentage dose uptake of 99mTc-DTPA by the kidneys and the plasma clearance of 99mTc-DTPA have been reported to correlate well with inulin clearance. These two parameters were evaluated in seven dogs with known or suspected naturally occurring renal disease and compared to simultaneously measured renal inulin clearance. Correlation between inulin clearance and the 99mTc-DTPA plasma clearance was better ( p =.0016) than the correlation between the percentage DTPA uptake by the kidney. It was concluded that measurement of 99mTc-DTPA plasma clearance is a more accurate method to estimate global glomerular filtration rate (GFR) than the percentage kidney uptake.  相似文献   
3.
Four dogs with ureteral fibroepithelial polyps, ranging from 9-12 years of age, are presented in this report. The patients presented with urinary incontinence, urinary tract infection, and/or polydypsia and pollakiuria. All dogs were intact at the time of diagnosis or for the majority of their lives and three were male. Various diagnostic procedures were performed including ultrasonography, contrast radiography, and nuclear scintigraphy. Not all procedures were performed in all patients. Findings included ureteral dilation proximal to the level of an intraluminal mass and ipsilateral hydronephrosis. Unilateral ureteronephrectomy was performed in three dogs with masses in the proximal ureter; ureteral resection and anastamosis was performed in the remaining patient with a mass located in the distal ureter. The same pathologist (RAP) reviewed all four lesions. The lesions appeared polypoid and were attached to the ureteral wall by a thin stalk. Histopathologically, they contained a superficial layer of well-differentiated transitional epithelial cells overlying a prominent fibrovascular stroma with a mild (three dogs) or marked (one dog) degree of lymphoplasmacytic inflammation. This disease may represent a benign neoplasm or a chronic inflammatory reaction and has a good prognosis with surgical removal. Its histopathological characteristics, higher incidence in males, and location more commonly within the upper third of the ureter is remarkably similar to the disease in humans.  相似文献   
4.
Paul  Y  Barthez  DVM  René  Léveillé  DVM  Peter  V  Scrivani  DVM 《Veterinary radiology & ultrasound》1997,38(5):387-393
Side lobes and grating lobes are both unwanted parts of the ultrasound beam emitted off axis that produce image artifacts due to error in positioning the returning echo. The purpose of this study was to reproduce artifacts associated with side lobes and grating lobes in vitro using different transducer types and recognize these artifacts in vivo. A phantom, composed of a water bath, a metallic wire, and a wooden tongue depressor, was imaged using a linear array, a curved linear array, a vector array, and a sector mechanical transducer. When imaging the metallic wire in a transverse plane, an echogenic artifact was constantly seen on each side of the wire, with a shape and intensity variable with the transducer type. The artifact was curvilinear and concave (linear and curved linear arrays), or curvilinear and convex (vector array and the mechanical transducer). When the tongue depressor was imaged in a longitudinal plane, the artifact was a straight line (linear array), a curved convex line(curved array), a series of convex curvilinear echo (vector array) or a small convex curvilinear echo (mechanical transducer). In vivo situations similar to the phantom experiment were investigated using clinical patients. Artifacts produced in vitro were recognized in vivo when a highly reflective object (urinary bladder wall) was imaged adjacent to an anechoic region (urine). These artifacts corresponded to the principle of secondary ultrasound lobes, and were therefore interpreted as such.  相似文献   
5.
A unique, "honeycomb" pattern was found on ultrasonographic evaluation of the liver of 5 dogs with canine superficial necrolytic dermatitis (hepatocutaneous syndrome). This pattern consisted of variably-sized, hypoechoic regions measuring 0.5–1.5 cm in diameter surrounded by highly echogenic borders. Histologically, the hypoechoic regions corresponded to distinct regenerative nodules bounded by severely vacuolated (fat-laden) hepatocytes, numerous bile ductules, and a network of reticulin and fine collagen fibers representing remnants of collapsed hepatic lobules. While certain features of the architectural disruption were characteristic of cirrhosis, the lesion lacked the extensive fibrosis and reduced liver size usually associated with chronic cirrhosis. To our knowledge, this hepatic ultrasonographic pattern has only been seen with canine superficial necrolytic dermatitis. Therefore, it appears to be pathognomonic in a dog with questinable skin lesions. A liver biopsy is required to confirm the unique histopathologic features of the hepatopathy found in this syndrome.  相似文献   
6.
7.
OBJECTIVE: To use scintigraphy to determine the effects of partial ureteral obstruction on renal transit time and induction of diuresis in dogs. ANIMALS: 8 adult dogs. PROCEDURE: Scintigraphy was performed, using technetium Tc 99m diethylenetriaminepentacetic acid (Tc 99m-DTPA), before and within 2 weeks after surgical induction of unilateral partial ureteral obstruction. Time of peak (TOP) for the parenchyma (pTOP) and whole kidney (wTOP) and mean-transit time (MTT) for the parenchyma (pMTT) and whole kidney (wMTT) were determined by evaluation of renal time-activity curves before and after deconvolution analysis. Percentage uptake for each kidney between 1 and 3 minutes after injection of Tc 99m-DTPA was determined and used to indicate glomerular filtration rate. The effect of diuresis was determined by measuring the slope of decrease in activity after i.v. administration of furosemide. Obstruction was documented by direct inspection of the ureter. RESULTS: There was a concomitant increase in pTOP, wTOP, pMTT, and wMTT of the kidney with the partially obstructed ureter in all dogs at various times between 2 and 9 days after surgery. Concurrently, renal time-activity curves changed shape. Percentage renal uptake of the affected kidney was decreased in 2 dogs. Response to furosemide injection was inconsistent for kidneys before surgery and for kidneys with obstructed and nonobstructed ureters after surgery. CONCLUSIONS AND CLINICAL RELEVANCE: Scintigraphy may be a useful procedure for the evaluation of renal function in dogs with ureteral obstruction. Induction of diuresis appears to be of little value for differentiating renal function in dogs with obstructed and nonobstructed ureters.  相似文献   
8.
Ultrasonography of the gallbladder was performed in 3 groups of dogs: 30 clinically healthy dogs, 50 dogs with hepatobiliary disease, and 50 dogs with diseases other than hepatobiliary disease. The gallbladder was evaluated for the presence of sludge (echogenic material without acoustic shadowing). Maximal gallbladder length, width, height, and area were measured as well as the gallbladder wall thickness. The relative sludge area was calculated as the ratio of sludge area over gallbladder area on longitudinal images. No significant difference was found in the prevalence of gallbladder sludge among healthy dogs (53%), dogs with hepatobiliary diseases (62%), and dogs with other disease (48%). The mean age of dogs with sludge was higher than the mean age of dogs without sludge in dogs with hepatobiliary disease and dogs with other diseases (p ≤0.05). The mean relative sludge area did not differ significantly among the 3 groups. A trend to larger gallbladder dimensions in dogs with sludge compared to dogs without sludge was detected within the 3 groups. The gallbladder wall thickness was not different between dogs with and without sludge within the 3 groups. However, the gallbladder wall was more frequently isoechoic than hyperechoic to the liver in dogs with sludge than in dogs without sludge. The results of this study indicate that gallbladder sludge, in dogs, in not particularly associated with hepatobiliary disease and should be considered an incidental finding.  相似文献   
9.
10.
The purpose of this study was to compare characteristics and performances between single-phase (SP) and high-frequency (HF) generators for x-ray units dedicated to veterinary radiology practice. A 30-kW SP and a 30-kW high HF generator connected to a rotating anode x-ray tube were used for the study. Source-film distance, screen/film combination, and film processing were kept the same during the experiment. The mAs value yielding a similar film optical density of a stair step phantom, as assessed by a densitometer and a similar dose, as assessed by a solid state detector, was estimated for different kVp values. The ratio of the mAs used with the SP generator to the equivalent mAs used with the HF generator to produce similar film density or radiation dose was calculated. Subject contrast was measured for different kVp values as the relative difference in film optical density between two steps of the phantom. The waveform of the tube current was recorded for the two generators using an oscilloscope. Motion artifact was produced on a lateral radiograph of a canine tarsus using the two generators. Reproducibility was assessed by comparing the variances of film density measurements made on the central step of the phantom on 10 consecutive images produced with the two generators. mAs ratios (SP/HF) to obtain similar film optical density ranged from 2 (for 90kVp) to 2.5 (for 70 kVp), and mAs ratios to obtain similar radiation dose ranged from 1.2 (for 100 kVp) to 1.4 (for 70 kVp). Image contrast was slightly higher for the SP than for the HF generator. Current waveform for the SP generator was half-sinusoidal and it was almost continuous for the HF generator. Motion artifact appeared as blur for the HF generator and as several regularly placed images of the subject for the SP generator. Reproducibility was significantly better for the HF than for the SP generator (P = 0.047). It was concluded that the HF generator was approximately two times more efficient, had a better reproducibility, and produced images with a lower contrast than the SP generator. Motion artifact appears differently due to different current waveform.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号