首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   17篇
  免费   2篇
畜牧兽医   18篇
植物保护   1篇
  2021年   1篇
  2019年   1篇
  2018年   2篇
  2017年   2篇
  2015年   1篇
  2012年   1篇
  2011年   4篇
  2010年   2篇
  2009年   1篇
  2008年   1篇
  2006年   2篇
  1990年   1篇
排序方式: 共有19条查询结果,搜索用时 561 毫秒
1.
Flunixin is marketed in several countries for analgesia in adult swine but little is known about its efficacy in piglets. Thirty‐two piglets (6–8 days old) were randomized to receive placebo saline (= 11, group CONTROL) or flunixin meglumine intravenously at 2.2 (= 11, group MEDIUM) or 4.4 (= 10, group HIGH) mg/kg, 10 hr after subcutaneous injection of kaolin in the left metacarpal area. A hand‐held algometer was used to determine each piglet’s mechanical nociceptive threshold (MNT) from both front feet up to 50 hr after treatment (cut‐off value of 24.5 newton). Serial venous blood samples were obtained to quantify flunixin in plasma using LC‐MS/MS. A PKPD model describing the effect of flunixin on the mechanical nociceptive threshold was obtained based on an inhibitory indirect response model. A two‐compartmental PK model was used. A significant effect of flunixin was observed for both doses compared to control group, with 4.4 mg/kg showing the most relevant (6–10 newton) and long‐lasting effect (34 hr). The median IC50 was 6.78 and 2.63 mg/ml in groups MEDIUM and HIGH, respectively. The ED50 in this model was 6.6 mg/kg. Flunixin exhibited marked antinociceptive effect on kaolin‐induced inflammatory hyperalgesia in piglets.  相似文献   
2.
In order to establish a genetic model of the resistance to Phytophthora cupsici in Capsicum annuum genotype‘Line 29′, three experiments were conducted which included, as well as‘Line 29′, the susceptible genotype‘Morron INIA 224’and several of its F1, F2, F3 and backcrosses. Plants with 4–6 leaves were inoculated by irrigating the culture substrate with a zoospore suspension of isolate B 1. The F2 test was applied to the segregating generations to test whether there were one, two, three or four genes involved in the resistance. Additivity and equal weight of all the genes in the final effect were assumed. The hypothesis that best explained the results obtained was the one that assumed three genes in‘Line 29′; at least four alleles had to be present in any genotype for it to behave as resistant. The possible influence of isolate aggressiveness and inoculation method on the results is discussed.  相似文献   
3.
To assess the antinociceptive efficacy of transdermal (TD) buprenorphine (B) in dogs, a prospective, positive-controlled experimental study was performed in 10 healthy Beagles. In an open label crossover design, the dogs initially received intravenous B (IVB, 0.02 mg kg?1) as a positive control, followed by TDB (52.5 μg h?1) 4 months later. Blood was collected at regular intervals for determination of the plasma concentrations of B ([B]) and its metabolite norbuprenorphine. The antinociceptive efficacy was assessed using thermal and mechanical models of nociception. The peak concentration [B] was 1.54 ng mL?1 (±1.98) 60 h after TDB application, although three dogs had no measurable [B] after TDB. Maximum thermal threshold (TT) was 52.6 °C (±0.48) at 1 h after IVB administration and 51.63 °C (±1.01) 72 h after TDB application. The significant increase in TT indicated that effective antinociception was achieved beyond 36 h after the application of TDB, lasting until patch removal. There was hysteresis between [B] and the antinociceptive effect.  相似文献   
4.
5.
The aim of this study was to quantify the effects of isoflurane at approximately the minimum alveolar concentration (peri-MAC) on the temporal summation (TS) of reflex activity in ponies. TS was evoked by repeated electrical stimulations applied at 5 Hz for 2 s on the digital nerve of the left forelimb of seven ponies. Surface electromyographic activity was recorded from the deltoid and common digital extensor muscles. TS thresholds and amplitude of response to stimulations of increasing intensities were assessed during anaesthesia at 0.85, 0.95 and 1.05 times the individual MAC, and after anaesthesia in standing animals. Under isoflurane anaesthesia, TS thresholds increased significantly in a concentration-dependent fashion and at each isoflurane MAC, the responses increased significantly for increasing stimulation intensities. A concentration-dependent depression of evoked reflexes with a reduction in the slopes of the stimulus–response function was observed for both muscles. The results demonstrated that with this model it is possible to describe and quantify the effects of anaesthetics on spinal sensory-motor processing in ponies.  相似文献   
6.
Objective To determine the minimum alveolar concentration (MAC) of isoflurane in Shetland ponies using a sequence of three different supramaximal noxious stimulations at each tested concentration of isoflurane rather than a single stimulation. Study design Prospective, experimental trial. Animals Seven 4‐year‐old, gelding Shetland ponies. Methods The MAC of isoflurane was determined for each pony. Three different modes of electrical stimulation were applied consecutively (2 minute intervals): two using constant voltage (90 V) on the gingiva via needle‐ (CVneedle) or surface‐electrodes (CVsurface) and one using constant current (CC; 40 mA) via surface electrodes applied to the skin over the digital nerve. The ability to clearly interpret the responses as positive, the latency of the evoked responses and the inter‐electrode resistance were recorded for each stimulus. Results Individual isoflurane MAC (%) values ranged from 0.60 to 1.17 with a mean (±SD) of 0.97 (±0.17). The responses were more clearly interpreted with CC, but did not reach statistical significance. The CVsurface mode produced responses with a longer delay. The CVneedle mode was accompanied by variable inter‐electrode resistances resulting in uncontrolled stimulus intensity. At 0.9 MAC, the third stimulation induced more positive responses than the first stimulation, independent of the mode of stimulation used. Conclusions The MAC of isoflurane in the Shetland ponies was lower than expected with considerable variability among individuals. Constant current surface electrode stimulations were the most repeatable. A summation over the sequence of three supramaximal stimulations was observed around 0.9 MAC. Clinical relevance The possibility that Shetland ponies require less isoflurane than horses needs further investigation. Constant current surface‐electrode stimulations were the most repeatable. Repetitive supramaximal stimuli may have evoked movements at isoflurane concentrations that provide immobility when single supramaximal stimulation was applied.  相似文献   
7.
A goat was scheduled for experimental surgery under general anesthesia. The first attempt of performing endotracheal intubation failed and provoked laryngeal spasm. After repeated succesful intubation of inhalation anesthesia was delivered in high concentrations of sevoflurane. Suddenly hypertension and tachycardia were observed, followed by foamy airway secretion and then severe airway hemorrhage. The authors hypothesize that laryngeal spasm provoked respiratory distress and pulmonary edema. The delivered high concentrations of sevoflurane probably enhanced a hyperadrenergic response, predisposing to the development of airway hemorrhage.  相似文献   
8.
OBJECTIVE: To investigate effects of isoflurane at approximately the minimum alveolar concentration (MAC) on the nociceptive withdrawal reflex (NWR) of the forelimb of ponies as a method for quantifying anesthetic potency. ANIMALS: 7 healthy adult Shetland ponies. PROCEDURE: Individual MAC (iMAC) for isoflurane was determined for each pony. Then, effects of isoflurane administered at 0.85, 0.95, and 1.05 iMAC on the NWR were assessed. At each concentration, the NWR threshold was defined electromyographically for the common digital extensor and deltoid muscles by stimulating the digital nerve; additional electrical stimulations (3, 5, 10, 20, 30, and 40 mA) were delivered, and the evoked activity was recorded and analyzed. After the end of anesthesia, the NWR threshold was assessed in standing ponies. RESULTS: Mean +/- SD MAC of isoflurane was 1.0 +/- 0.2%. The NWR thresholds for both muscles increased significantly in a concentration-dependent manner during anesthesia, whereas they decreased in awake ponies. Significantly higher thresholds were found for the deltoid muscle, compared with thresholds for the common digital extensor muscle, in anesthetized ponies. At each iMAC tested, amplitudes of the reflex responses from both muscles increased as stimulus intensities increased from 3 to 40 mA. A concentration-dependent depression of evoked reflexes with reduction in slopes of the stimulus-response functions was detected. CONCLUSIONS AND CLINICAL RELEVANCE: Anesthetic-induced changes in sensory-motor processing in ponies anesthetized with isoflurane at concentrations of approximately 1.0 MAC can be detected by assessment of NWR. This method will permit comparison of effects of inhaled anesthetics or anesthetic combinations on spinal processing in equids.  相似文献   
9.
10.
The objective of this study was to assess a pharmacokinetic algorithm to predict ketamine plasma concentration and drive a target-controlled infusion (TCI) in ponies.Firstly, the algorithm was used to simulate the course of ketamine enantiomers plasma concentrations after the administration of an intravenous bolus in six ponies based on individual pharmacokinetic parameters obtained from a previous experiment. Using the same pharmacokinetic parameters, a TCI of S-ketamine was then performed over 120 min to maintain a concentration of 1 μg/mL in plasma. The actual plasma concentrations of S-ketamine were measured from arterial samples using capillary electrophoresis.The performance of the simulation for the administration of a single bolus was very good. During the TCI, the S-ketamine plasma concentrations were maintained within the limit of acceptance (wobble and divergence <20%) at a median of 79% (IQR, 71–90) of the peak concentration reached after the initial bolus. However, in three ponies the steady concentrations were significantly higher than targeted.It is hypothesized that an inaccurate estimation of the volume of the central compartment is partly responsible for that difference. The algorithm allowed good predictions for the single bolus administration and an appropriate maintenance of constant plasma concentrations.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号