首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 343 毫秒
1.
This prospective study compared aortic and hepatic enhancement achieved using a contrast injection protocol with a fixed rate of 5 ml/s vs. that achieved using a protocol with fixed injection duration of 20 s in eight cats. Cats were assigned into two groups (Group 1, rate 5 ml/s; Group 2, duration 20 s). The dose of contrast was the same in both groups (740 mgI/kg). Regions of interest (ROI) were drawn in the aorta and liver for transverse scans acquired at the hepatic hilus. Time to peak aortic enhancement occurred significantly earlier in Group 1 (M = 11s, SD = 1.63) than in Group 2 (M = 25.5 s, SD = 2.51). Peak aortic enhancement was significantly higher in Group 1 (M = 1906.51 HU, SD = 368.64) than in Group 2 (M = 745.08 HU, SD = 201.84). Duration of aortic enhancement equal to or above 300 HU was statistically longer in Group 2 (M = 24.5 s, SD = 8.39) than in Group 1 (M = 10 s, SD = 1.63). There were no significant differences in time to peak liver enhancement, peak liver enhancement, or duration of hepatic arterial phase between groups. Findings supported the hypothesis that longer injection duration results in a broader bolus geometry with a longer time to peak and a lower peak aortic enhancement in cat. This strong influence of injection duration on timing of aortic enhancement may help future users optimize protocols for CT angiography of the aorta and multiphasic evaluation of the liver, pancreas, and small intestine.  相似文献   

2.
Rapid contrast injection is recommended for triple‐phase helical computed tomography (CT) of the liver. However, a large‐gauge catheter is needed for faster contrast injection and this is not practical for small breed dogs or cats. The purpose of this crossover group study was to evaluate applicability of a lower injection rate with a small‐gauge (G) catheter for triple‐phase hepatic CT in small dogs. Triple‐phase CT images were acquired for six beagle dogs using three protocols: an injection rate of 1.5 ml/s with a 24 G catheter, 3.0 ml/s with a 22 G catheter, and 4.5 ml/s with a 20 G catheter. Enhancement of the aorta, portal vein, and hepatic parenchyma was measured in each phase (arterial, portal, and delayed) and image quality was scored subjectively by two observers. Injection duration, time to scan delay, and time to peak enhancement were also recorded. Contrast injection duration decreased with a higher injection rate (n = 6, P ≤ 0.01), but time to peak enhancement and time to scan delay were not significantly affected by injection rates and catheter sizes. Contrast injection rate did not significantly affect aortic, portal, and hepatic enhancement. In addition, separation between each phase and quality of images was subjectively scored as good regardless of injection rate. Findings from the current study supported using an injection rate of 1.5 ml/s with a catheter size of 24 G for triple‐phase hepatic CT in small dogs (weight < 12 kg).  相似文献   

3.
Gadolinium‐enhancement of compressive extradural material is detected occasionally with magnetic resonance (MR) imaging in dogs. Our goal was to characterize contrast enhancement of extradural compressive material associated with intervertebral disc herniation, and to evaluate the association between enhancement and histopathologic findings and the onset of clinical signs. Ninety‐three dogs with a total of 99 lesions diagnosed as intervertebral disc herniation on MR imaging were assessed. Images were evaluated for lesion location, type of herniation, degree of compression, intramedullary T2‐weighted (T2W) intensities, and contrast enhancement. In 23 dogs, surgically removed compressive material was evaluated histopathologically for hemorrhage, inflammation, neovascularization, fibroplasia, fibrosis, mineralization, necrosis, and chronicity. Contrast enhancement of extradural compressive material, meninges, and both the compressive materials and meninges was present in 51.5%, 39.4%, and 17.2% of lesions, respectively. Extradural enhancement occurred more frequently in extrusions than protrusions (P=0.001). Meningeal enhancement and more severe neurologic deficits were significantly associated with a shorter duration of clinical signs (P=0.04 and 0.01, respectively). Intramedullary T2W hyperintensities, present with 44.4% of lesions, were associated with more severe neurologic deficits (P=0.001). Lesions with extradural enhancement were more often considered subacute to chronic in duration and more frequently associated with hemorrhage compared with nonenhancing material; however, no statistically significant association was established between contrast enhancement and histopathologic findings. Contrast enhancement of extradural compressive material and the meninges was found to be common with intervertebral disc herniation, and should not be interpreted as a specific sign of a mass lesion such as neoplasia.  相似文献   

4.
As gadolinium‐based contrast agents are paramagnetic and have T2 shortening effects, they have the potential to adversely affect gradient recalled echo sequences. The aim of this prospective, cross‐sectional study was to evaluate the effects of gadolinium administration on T2*‐weighted sequence diagnostic quality and signal intensity when imaging the canine brain. A total of 100 dogs underwent brain magnetic resonance imaging (MRI) including pre‐ and postcontrast T2*‐weighted sequences acquired with a delay (Group A) or immediately (Group B) following gadolinium administration. Pre‐ and postcontrast images were subjectively compared. In dogs with intracranial enhancing masses, regions of interest were drawn on corresponding images and signal intensity ratios were calculated. The effect of degree and pattern of contrast enhancement, susceptibility artifacts, and time between contrast injection and T2*‐weighted sequence acquisition on signal intensity ratio was evaluated. Overall 31 dogs had contrast enhancing intracranial masses. Subjectively, there was no difference in image quality of T2*‐weighted sequences obtained before and after contrast medium administration. No significant signal intensity differences of intracranial contrast enhancing masses were found (Group A P = 0.9999; Group B P = 0.9992). Susceptibility artifacts did not differ in appearance, and there was no effect on calculated signal intensity ratio (P = 0.8142). Similarly, there was no effect of degree of enhancement or contrast heterogeneity on signal intensity ratio (P = 0.4413). No correlation was found between signal intensity ratio and the time to acquisition (P = 0.199). Administration of gadolinium‐based MRI contrast agents does not adversely affect T2*‐weighted imaging of the brain in dogs at 1.5 T even in the presence of contrast enhancing lesions.  相似文献   

5.
Objectives – To develop a direct method for measuring intra‐abdominal pressures in the standing horse, identify a reference interval for direct intra‐abdominal pressures, compare these pressures to indirect intra‐abdominal pressures measured from the bladder, and determine the optimal bladder infusion volume for indirect pressure measurement. Design – Prospective, experimental study. Setting – A university‐based equine research facility. Animals – Ten healthy adult horses, 5 males and 5 females. Interventions – Direct intra‐abdominal pressures were measured through an intraperitoneal cannula and zeroed at the height midway between the height of the tuber ishii and point of the shoulder. Indirect measurements of intra‐abdominal pressure were performed by measuring intravesicular pressures through a transurethral catheter zeroed at the tuber ishii. Measurements and Main Results – Direct pressure measurements obtained in the standing horse were subatmospheric (mean, ?1.80 cm H2O; SD, 1.61 cm H2O; 95% CI, ?2.80 to ?0.80) and were shown to decrease as the horse's weight increased (Pearson's r=?0.67, P=0.04), with no effect of head position (P=0.15). Mean baseline indirect pressure measurements (mean, ?8.63 cm H2O; SD, 4.37 cm H2O; 95% CI, ?13.05 to ?4.21) were significantly different from the pressures measured directly from the abdomen (P<0.001). Indirect pressure measurements were noted to increase with increasing volumes infused into the bladder, and were statistically different at a volume of 100 mL (P=0.004). There was low to moderate correlation between direct and indirect pressure measurements of intra‐abdominal pressure over a range of fluid volumes infused into the bladder (Pearson's correlation range ?0.38 to 0.58). Conclusion – Pressures measured directly in the standing horse were subatmospheric, and increased as the horse's weight increased. Indirect pressures measured were altered by increasing volumes infused in the bladder. There was no significant correlation between the 2 methods of intra‐abdominal pressure measurement.  相似文献   

6.
We evaluated dynamic contrast‐enhanced magnetic resonance imaging (DCE‐MRI) in canine brain tumors. Magnetic resonance data sets were collected on seven canine intracranial tumors with a 3 T magnet using a T1‐weighted fast spin echo fluid attenuated inversion recovery sequence after an IV bolus injection (0.2 mmol/kg) of Gd‐DTPA. The tumors were confirmed histopathologically as adenocarcinoma (n=1), ependymoma (n=1), meningioma (n=3), oligodendroglioma (n=1), and pituitary macroadenoma (n=1) The data were analyzed using a two‐compartment pharmacokinetic model for estimation of three enhancement parameters, ER (rate of enhancement), Kel (rate of elimination), and Kep (rate constant), and a model‐free phenomenologic parameter initial area under the Gd concentration curve (IAUGC) defined over the first 90 s postenhancement. Pearson's correlations were calculated between parameters of the two methods. The IAUGC has a relatively strong association with the rate of enhancement ER, with r ranges from 0.4 to 0.9, but it was weakly associated with Kep and Kel. To determine whether any two tumors differed significantly, the Kolmogorov–Smirnov test was used. The results showed that there were statistical differences (P<0.05) between distributions of the enhancement pattern of each tumor. These kinetic parameters may characterize the perfusion and vascular permeability of the tumors and the IAUGC may reflect blood flow, vascular permeability, and the fraction of interstitial space. The kinetic parameters and the IAUGC derived from DCE‐MRI present complementary information and they may be appropriate to noninvasively differentiate canine brain tumors although a larger prospective study is necessary.  相似文献   

7.
Background: Microalbuminuria and C‐reactive protein (CRP) are predictors of morbidity and survival in critically ill human patients. Hypothesis/Objectives: To evaluate results of microalbuminuria assays (untimed single‐sample urine albumin concentration [U‐ALB] and the urine albumin : creatinine ratio [UACR]), serum CRP, and survival predictor index (SPI2) scores as predictors of survival in critically ill dogs. Animals: Seventy‐eight dogs admitted to intensive care units at University of Tennessee (UT) and Colorado State University (CSU). Methods: Prospective observational study. Critically ill dogs were eligible for enrollment, unless euthanized because of financial constraints. Samples were collected within 3 hours of admission. Spearman's rank‐correlation coefficients were determined for U‐ALB, UACR, CRP, and SPI2. U‐ALB, UACR, CRP, and SPI2 were assessed for associations with 7‐ and 30‐day survival by Mann‐Whitney U‐tests and receiver operating characteristic (ROC) curves. P‐values < .0125 were considered significant. Results: UT (n = 49) and CSU (n = 29) patients did not differ significantly. Forty percent (31/78) of dogs died. SPI2 was inversely correlated with U‐ALB (rs=?0.39, P < .001) and UACR (rs=?0.41, P < .001). CRP was not correlated with SPI2 (P= .019), U‐ALB (P > .1), or UACR (P > .1). U‐ALB and UACR had very high correlation (rs= 0.95, P < .001). SPI2, U‐ALB, and UACR differed significantly for survivors and nonsurvivors. SPI2, U‐ALB, and UACR had areas under the ROC curve (AUC) from 0.68 to 0.74 for survival prediction. Conclusions and Clinical Importance: Albuminuria and SPI2, but not CRP, are associated with survival in critically ill dogs. Suboptimal AUCs limit the value of microalbuminuria testing for clinical risk assessment. Additional studies are necessary to determine the usefulness of microalbuminuria testing in patient risk stratification for prospective research.  相似文献   

8.
Heritability values of glycerol, glycogen and pigment concentrations measured on muscle biopsy samples from longissimus dorsi obtained from 85?kg boars of Danish purebred pigs (Landrace, Yorkshire, and Duroc) and their genetic correlations to performance and meat quality traits were calculated. The heritability values of glycogen, pigment, and glycerol were 0.38±0.02, 0.17±0.02, and 0.065±0.016, respectively. Glycogen was negatively related to the feed conversion ratio (FCR) (r g =?0.25±0.06) and ultimate meat pH (r g =?0.41±0.04), and positively to the carcass meat percentage (r g =0.35±0.04), L* (lightness of meat, r g =0.32±0.04) and a* (redness of meat, r g =0.12±0.03). Pigment was positively related to the FCR (r g =0.12±0.05), the meat percentage (r g =0.28±0.05), and a* (r g =0.59±0.04), and negatively to the L* (r g =?0.46±0.06). The concentrations of pigment and glycogen (r g =0.27±0.05) were interrelated. Based on the heritability values and the signs of the genetic correlations the present data suggest that it is possible to select for higher ultimate pH and improved colour by selection for either lower muscle glycogen or higher pigment concentration, respectively. However, the positive genetic correlation between these two traits may restrict the efficiency of simultaneous selection for lower glycogen and higher pigment. All genetic parameter estimates presented are calculated across three purebreds. Values for each breed are warranted for use in pig production. However, this requires more animals per breed.  相似文献   

9.
Magnetic resonance imaging (MRI) has been recommended for staging and surgical planning in cats with injection site sarcomas (ISS). The purpose of this retrospective study was to describe low‐field MRI characteristics of confirmed injection site sarcomas in a group of cats. Low‐field MR images, thoracic radiographs, histopathology findings, and medical records of cats that fulfilled histological criteria of injection site sarcoma were retrieved and reviewed retrospectively. Presence or absence of tumor mineralization and pulmonary metastases were recorded from thoracic radiographs. Characteristics recorded from low‐field MRI studies included tumor number, volume (ellipsoid method), intensity relative to surrounding musculature, homogeneity, regions of signal void (mineralization) or cavitation, degree and pattern of contrast enhancement, tumor margination, presence of a peripheral T2W hyperintense zone, and bone contact. A total of 19 cats met inclusion criteria. Cats with multiple tumors were more likely to have had previous excisional biopsy, and were less likely to undergo definitive surgery. All tumors were hyperintense relative to surrounding musculature on T1W and T2W images. Larger tumors were more likely to exhibit mineralization (P < 0.05). Tumor volume could not predict tumor‐free margins at definitive surgery. The majority of tumors showed moderate to marked heterogeneous contrast enhancement. Infiltrative margins and the presence of a peripheral T2W hyperintense zone were more prevalent following excisional biopsy, while cavitation was more prevalent following incisional biopsy. Findings indicated that low‐field MRI characteristics of injection site sarcoma may vary widely and may be affected by prior incisional or excisional biopsy.  相似文献   

10.
While the availability and use of computed tomography (CT) continues to grow, no study has described the size and multiphase CT appearance of the normal feline pancreas. This information is important to not only allow more accurate identification and differentiation of disease, but it may also be useful in assessing pancreatic function. In this prospective analytical study, we described a triple phase CT protocol of the pancreas for use in sedated cats and the attenuation, enhancement pattern, size, and volume of the pancreas for a group of healthy cats. Fifteen healthy cats were enrolled in the study and a standardized protocol for acquiring arterial, portal, and delayed phase CT images of the pancreas was developed and described. The pancreas was hypo to isoattenuating to both the liver and spleen in all phases in the majority of cats with a homogenous enhancement pattern noted in all 15. Mean pancreatic attenuation was 48, 79, 166, and 126 Hounsfield units (HU) respectively on precontrast, arterial, portal, and delayed phase images. In addition, mean height, length, and width of the left lobe of the pancreas were larger than the right lobe in all 15 cats. There were no associations between volume and volume: body weight ratio with age (P = 0.6518, P = 0.6968) or sex (P = 0.7013, P = 0.2043). This baseline information may be beneficial for use in future studies characterizing pancreatic disease in cats as well as future research studies evaluating pancreatic endocrine function.  相似文献   

11.
Certain magnetic resonance (MR) enhancement patterns are often considered to be associated with a specific diagnosis but experience shows that this association is not always consistent. Therefore, it is not clear how reliably contrast enhancement patterns correlate with specific tissue changes. We investigated the detailed histomorphologic findings of intracranial lesions in relation to Gadodiamide contrast enhancement in 55 lesions from 55 patients, nine cats, and 46 dogs. Lesions were divided into areas according to their contrast enhancement; therefore 81 areas resulted from the 55 lesions which were directly compared with histopathology. In 40 of 55 lesions (73%), the histomorphologic features explained the contrast enhancement pattern. In particular, vascular proliferation and dilated vessels occurred significantly more often in areas with enhancement than in areas without enhancement (P=0.044). In 15 lesions, there was no association between MR images and histologic findings. In particular, contrast enhancement was found within necrotic areas (10 areas) and ring enhancement was seen in lesions without central necrosis (five lesions). These findings imply that necrosis cannot be differentiated reliably from viable tissue based on postcontrast images. Diffusion of contrast medium within lesions and time delays after contrast medium administration probably play important roles in the presence and patterns of contrast enhancement. Thus, histologic features of lesions cannot be predicted solely by contrast enhancement patterns.  相似文献   

12.
Selection for increased leanness and improved food efficiency in pigs has resulted in a decreased voluntary food intake. It has been argued that voluntary food intake during lactation should be considered in sow breeding programmes. The aim of the present study was to investigate the phenotypic correlation of food intake during growth and food intake at maturity with maximum lactation food intake in a mouse model. A total of 179 records were available on female mice selected for litter size at birth (S-line) and non-selected control females (C-line) from 3 weeks of age to 21 days in lactation. Half of the litters were standardized to eight pups per litter (s) and half were not standardized (ns). Growth intake was measured as the average intake between 21 and 42 days of age, mature intake was measured from a linear regression of food intake against age between 42 and 69 days of age, and lactation intake was measured as a linear regression of food intake against days in lactation between 5 and 14 days in lactation. In both lines, females with a higher growth intake also had a higher mature intake (r = 0.63 to 0.75, P < 0.0001). Lactation intake was related with growth intake and mature intake in Sns females (r = 0.50 and 0.46, P < 0.01) and with growth intake in Ss females (r = 0.32, P < 0.05). In both lines, lactation intake was highly correlated with litter weight (r = 0.48 to 0.94, P < 0.001). Sns and Ss females with higher growth intake supported larger litter weights during lactation (r = 0.32 and 0.30, respectively, P < 0.05) and Sns females with higher mature intakes tended to support larger litter weights (r = 0.28, P = 0.060). It is suggested that lactating C-line females eat to support a given litter size, while S-line females support the maximum litter weight that is allowed for by their intake capacity, and still produce at high levels when litters are standardized. Since lactating sows mobilise body reserves, the relationship of food intake during growth with that during lactation may be reflected in the relationship between growth intake and body condition.  相似文献   

13.
Contrast‐enhanced ultrasound of the spleen enables the dynamic assessment of the perfusion of this organ, however, both subjective and quantitative evaluation can be strongly influenced by sedative agent administration. The purpose of this prospective, experimental study was to test effects of two sedative agents on splenic perfusion during contrast‐enhanced ultrasound of the spleen in a sample of healthy dogs. Contrast‐enhanced ultrasound of the spleen was repeated in six healthy Beagles following a cross‐over study design comparing three protocols: awake, butorphanol 0.2 mg/Kg intramuscular (IM), and dexmedetomidine 500 μg/m2 IM. After intravenous injection of a phospholipid stabilized sulfur hexafluoride microbubble solution (SonoVue®, Bracco Imaging, Milano, Italy), the enhancement intensity and perfusion pattern of the splenic parenchyma were assessed and perfusion parameters were calculated. Normal spleen was slightly heterogeneous in the early phase, but the parenchyma was homogeneous at a later phase. Sedation with butorphanol did not modify perfusion of the spleen. Dexmedetomidine significantly reduced splenic enhancement, providing diffuse parenchymal hypoechogenicity during the entire examination. Measured parameters were significantly modified, with increased arrival time (AT; (< 0.0001) and time to peak (TTP; P < 0.0001), and decreased peak intensity (PI; P = 0.0108), wash‐in (P = 0.0014), and area under the curve (AUC; P = 0.0421). Findings supported the use of butorphanol and contraindicated the use of dexmedetomidine as sedatives for splenic contrast ultrasound procedures in dogs. Short‐term and diffuse heterogeneity of the spleen in the early venous phase was determined to be a normal finding.  相似文献   

14.
Vascular alterations play important roles in many orthopedic diseases such as osteoarthritis, tendonitis, and synovitis in both human and equine athletes. Understanding these alterations could enhance diagnosis, prognosis, and treatment. Contrast‐enhanced ultrasound (CEUS) could be a valuable method for evaluation of blood flow and perfusion of these processes in the equine distal limb, however no reports were found describing feasibility or safety of the technique. The goal of this prospective, experimental study was to describe the feasibility and safety of distal limb CEUS in a sample of six horses. For each horse, CEUS of the distal limb was performed after intravenous injections of 5 and 10 ml, as well as intra‐arterial injections of 0.5 and 1 ml contrast medium. Vital parameters were monitored and CEUS images were assessed qualitatively and quantitatively for degree of contrast enhancement. None of the horses had clinically significant changes in their vital parameters after contrast medium injection. One horse had a transient increase in respiratory rate, and several horses had mild increases of systolic blood pressure of short duration after intravenous, but not after intra‐arterial injections. Intra‐arterial injection was possible in all horses and resulted in significantly improved contrast enhancement both quantitatively (P = 0.027) and qualitatively (P = 0.019). Findings from this study indicated that CEUS is a feasible and safe diagnostic test for evaluation of the equine distal limb. Future studies are needed to assess the clinical utility of this test for horses with musculoskeletal diseases.  相似文献   

15.
The purpose was to evaluate the capacity of 1.5 T magnetic resonance (MR) imaging to assess articular cartilage in racehorses with naturally occurring metacarpophalangeal joint osteoarthritis. A sagittal, three‐dimensional spoiled gradient‐recalled echo (SPGR) with fat saturation (FS) sequence was acquired ex vivo on 20 joints. Following joint dissection, specific areas on the third metacarpal condyle were designated for subsequent sampling for histologic cartilage thickness measurement and modified Mankin scoring. Cartilage thickness was measured and cartilage signal intensity was also graded (0–3) on MR images at these selected metacarpal sites. Cartilage structure was graded (0–3) macroscopically and on MR images by two examiners in defined subregions of the proximal phalanx, third metacarpal, and proximal sesamoid bones. There was good precision (mean error 0.11 mm) and moderate correlation (r=0.44; P<0.0001) of cartilage thickness measurements between MR images (0.90±0.17 mm) and histology (0.79±0.16 mm). There was moderate correlation between modified Mankin histologic score and signal intensity of cartilage (r=0.36; P<0.01) or MR cartilage structure assessment (r=0.49, P>0.001) on SPGR‐FS. The sensitivity to detect full‐thickness cartilage erosion on MR was only moderate (0.56), and these lesions were often underestimated, particularly when linear in nature. However, the specificity to detect such lesions on MR was high (0.92). While few limitations were identified, the use of a clinically applicable SPGR‐FS sequence allows a reasonably accurate method to assess structural changes affecting the articular cartilage of the equine metacarpophalangeal joint.  相似文献   

16.
Abstract

The relationship of milk fat–protein ratio (FP), body condition score (BCS), body weight (BW) and their changes (ΔBCS, ΔBW) to energy balance (EB) in early lactation, and usefulness of the traits for predicting of EB of primiparous Finnish Red Dairy Cattle were studied. BW on the first test-day after calving correlated negatively (r=?0.30; P<0.02) with EB, suggesting large loss of body reserves for heavier cows. FP correlated significantly (r=?0.37) with EB on the first but not on the other test-days. Thus, when a single measure of FP is used to predict EB, records on the first test-day after calving seem to be the most appropriate. Milk FP was a better predictor of EB than BCS, BW or their changes. The accuracies of predictions were moderate; the best prediction explained 39.4% of EB variation. The low accuracy was suggested to be caused by imprecision in estimation of the EB.  相似文献   

17.
18.
Contrast-enhanced ultrasonography has an important role in the detection of tumors in humans. The second-generation contrast agent Sonazoid has the ability of real-time contrast imaging along with parenchymal imaging. The purposes of this study were to determine the effect and duration of Sonazoid on the changes in gray-scale enhancement of canine spleen and to establish an appropriate protocol for contrast-enhanced ultrasonography of canine spleen. Six healthy beagles were injected with an intravenous bolus of Sonazoid. In the spleen parenchyma, the enhancement was maintained up to 30 min after injection. Moreover, for 5–22 s after injection, gray-scale enhancement of splenic arteries afforded arterial imaging. Perfusion of the kidney may be investigated from 3.6 s to 3.5 min after injection of Sonazoid. These results suggest that Sonazoid is applicable to canine spleen parenchymal imaging and that the optimal time for the parenchymal imaging is 7–30 min after injection. The findings of this quantitative study should prove useful in the evaluation of diffuse or focal splenic and renal diseases in dogs.  相似文献   

19.
Dynamic CT was performed in five normal Holstein calves to investigate the effect of saline chasers on intravascular contrast enhancement when administered at three different rates. The five calves were imaged using dynamic CT in a crossover study design. Group A was administered only contrast medium (600 mg iodine/kg, 4 ml/s), while groups B, C and D were administered contrast medium at 30 per cent reduction followed by saline chasers injected at 2, 4 and 8 ml/s, respectively. Attenuation values were obtained from the right and left maxillary arteries and dorsal sagittal sinus. Maximum enhancement value and mean value of the enhancement plateau obtained from the maxillary arteries were significantly lower in group B than in the other groups. The duration of the enhancement plateau was longer in group C than in groups B and D (P<0.05).  相似文献   

20.
Tracheobronchial lymph node evaluation is critical for accurate staging of canine thoracic neoplasia and is more accurately achieved with computed tomography (CT) than radiography. Thoracic CT scans of 18 canine patients with known tracheobronchial lymph node histopathology and 10 clinically normal dogs were compared to establish if enlargement or contrast enhancement pattern correlated with metastatic status. Absolute lymph node size and three anatomically normalized lymph node ratios were significantly correlated with metastasis or severe granulomatous lymphadenitis (P<0.0003). Transverse maximum lymph node diameter of 12 mm or lymph node to thoracic body ratio of 1.05 are proposed cutoffs, above which metastatic involvement is very likely; however, only minimal accuracy was gained with normalized ratios. Lymph node contrast enhancement pattern was also significantly correlated to disease. A heterogenous and/or ring pattern was related to metastatic disease (P=0.03). Recommended protocol for CT examination of the tracheobronchial lymph nodes is 1–1.5 mm slices and intervals, intravenous contrast, and control of respiratory motion.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号