首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
OBJECTIVE: To determine whether cattle testing positive for Mycobacterium avium subsp paratuberculosis as determined by microbial culture of feces or antibody ELISA were more likely to have false-positive responses on the caudal fold tuberculin (CFT) test or interferon-gamma (IFN-gamma) assay for Mycobacterium bovis than cattle testing negative for M paratuberculosis. ANIMALS: 1043 cattle from 10 herds in Michigan. PROCEDURE: Feces and blood samples for plasma were collected from cattle > or =24 months old on the day the CFT test was read. Fecal samples were submitted for microbial culture for M paratuberculosis. Plasma samples were tested for antibody against M paratuberculosis, and IFN-gamma after stimulation with purified protein derivative tuberculin from M bovis or M avium. RESULTS: Of 1043 cattle, 180 (17.3%) had positive CFT test results (suspects) and 8 (0.8%) had positive IFN-gamma assay results after stimulation with purified protein derivative tuberculin from M bovis. Forty-five (4.3%) and 115 (11.0%) cattle tested positive for M paratuberculosis as determined by microbial culture of feces and antibody ELISA, respectively. Cattle with positive responses for M paratuberculosis appeared to have an increased likelihood of false-positive results on the CFT test, although this association was not significant. CONCLUSIONS AND CLINICAL RELEVANCE: No significant association was detected among cattle testing positive for M paratuberculosis as determined by microbial culture of feces and antibody ELISA and positive CFT test and IFN-gamma assay results for M bovis.  相似文献   

2.
Three hundred and forty-one sera from cattle in Western Australia and 106 sera from Mycobacterium paratuberculosis faecal culture positive cattle were used to evaluate the performance of two absorbed enzyme-linked immunosorbent assays (ELISA) (one locally produced, the other a commercial test) and a complement fixation test (CFT) for the detection of Johne's disease in cattle. The diagnostic sensitivity (47.2%) of the local ELISA was significantly higher than that of the commercial ELISA (31.1%), and significantly higher than that for the complement fixation test (17.9%) and immunoblot (20.8%). Diagnostic specificity for the two ELISAs was 99.7% and 97.9% and similar for CFT and immunoblot (97.1% and 97.7%, respectively). The diagnostic sensitivity rose for both ELISAs and the CFT as the number of M. paratuberculosis isolated from the faeces increased. The ELISA antigen was characterised by polyacrylamide gel electrophoresis and electrophoretic immunoblotting and was found to consist mostly of a carbohydrate-type macromolecule of 32-42 kDa. This macromolecule was identified as lipoarabinomannan (LAM) by using a LAM-specific monoclonal antibody in immunoblots and purified LAM in absorption experiments. By applying more complex antigen preparations in immunoblots, serum antibodies against proteins of 47, 37, 30, 24 and 21 kDa, and against the 32-42 kDa carbohydrate component were frequently found in infected cattle, and of these the 47 kDa protein and the 32-42 kDa antigen were immuno-dominant. Pre-absorption of the sera with M. phlei sonicate indicated that the protein antigens contributed markedly to non-specific serological cross-reactions, while the 32-42 kDa non-protein macromolecule appeared to be specific.  相似文献   

3.
A commercially available absorbed ELISA for the diagnosis of Johne's disease (JD) (paratuberculosis) in cattle, the Johne's Absorbed EIA, was compared with the conventional complement-fixation test (CFT) used in Australia. Stored plasma from 3 Victorian dairy herds with a history of JD, sera from specimens submitted from animals showing clinical signs of JD and sera from the US National Repository for Paratuberculosis Specimens were used to determine the sensitivity of each test. The EIA detected 48.8% of 43 Australian animals with subclinical JD, while the CFT detected only 12 (21.4%) of 56 subclinically affected cattle. Of 150 subclinically infected US cattle, the EIA detected 47.3% and the CFT detected 52.0%. The EIA detected 59.7% of animals which at the time of sampling were shedding Mycobacterium paratuberculosis in their faeces, but showed no clinical signs of JD, while the CFT detected 57.3%. The EIA correctly identified 88.2% of 136 histologically confirmed clinical cases, and the CFT detected 83.4%. The specificity of each test was determined by testing sera collected at slaughter from animals residing in a known JD-free area of Australia, and from samples from the US National Repository of Paratuberculosis Specimens collected from certified-free herds in Wisconsin. The EIA was found to have a specificity of 99.8% when 998 Australian animals were used as the test population, and 99.0% when 196 US animals were used. The specificity of the CFT using Australian samples was 96.9% and 95.2% using American samples.  相似文献   

4.
An antigen was isolated from the protoplasm of Mycobacterium paratuberculosis by a combination of gel filtration, ion exchange, and affinity chromatography. The purified antigen constituted 7.8% of the total protein in the protoplasm. The specificity and sensitivity of the enzyme-linked immunosorbent assay (ELISA) for paratuberculosis, using the purified antigen, were evaluated with sera from 104 cattle which were examined (surveyed) for M paratuberculosis infection by fecal cultural technique. The ELISA was positive in 50 of 60 infected animals. Five of 44 noninfected animals were also test-positive. When a crude protoplasmic extract was used as antigen in the ELISA, sera from 37 infected and from 18 noninfected animals were test-positive. Cross-reactions were encountered in both complement-fixation test and the ELISA between crude or partially purified M paratuberculosis antigens and antisera to Nocardia asteroides, M avium, M phlei, and M fortuitum. The purified antigen gave no complement-fixation reaction with any of these antisera. In the ELISA, cross-reaction was not found when purified antigen was used and the sera were screened at 1:40 dilution.  相似文献   

5.
Three serological assays were compared for detection of antibodies to bovine herpes-virus type 1. These were virus neutralization (VN), enhanced complement fixation (CF) and enzyme-linked immunosorbent assay (ELISA). The ELISA was developed using an infected cell lysate antigen and purified virus and was optimized in relation to antigen and antisera dilutions. The CF assay was enhanced by the addition of bovine complement. These 3 assays were compared for detection of: specific virus antibody titers; sero-conversions; early antibody response in experimentally-infected cattle. Both ELISA end-point titers and single dilution values were found to be more sensitive than the CF or VN assays for specific antibody level quantitation. With a single dilution ELISA test procedure a correlation was obtained between ELISA values and VN titers. Using the single dilution ELISA test the assay also detected antibodies in experimentally-infected cattle before either the VN or CF assays, and agreed with the VN test in 35/38 seroconversions found by 4-fold or more VN changes between acute and convalescent paired sera from naturally-infected animals. The single dilution ELISA was a rapid and sensitive test for routine antibody detection in bovine sera.  相似文献   

6.
为建立检测牛传染性鼻气管炎病毒(IBRV)血清抗体的阻断ELISA方法,本研究以经蔗糖密度梯度离心法纯化的IBRV作为免疫原制备1株单克隆抗体(MAb),命名为cp-1-1。经间接ELISA、IFA和western blot鉴定,该MAb与IBRV呈阳性反应,与牛病毒性腹泻病毒(BVDV)及牛副流感病毒3型(BPIV3)呈阴性反应,具有较强的特异性。质谱分析结果显示MAb cp-1-1识别的表位位于IBRV VP8蛋白。以纯化的IBRV作为包被抗原、MAb cp-1-1作为检测抗体,建立检测IBRV血清抗体的阻断ELISA方法。该检测方法的抗原包被量为0.89μg/孔,样品稀释度为12,检测抗体MAb量为1.3μg/孔,二抗稀释度为15000。利用50份IBRV抗体呈弱阳性的牛血清(中和抗体效价为14~116)作为标准参考血清,确定该检测方法的阻断率Cut Off值为52.06%,即阻断率高于52.06%时判为阳性,低于52.06%时判为阴性。阻断ELISA方法特异性试验显示仅IBRV阳性血清检测为阳性,而BVDV、BPIV3、牛腺病毒3型(BADV-3)和O型口蹄疫病毒(O-FMDV)阳性牛血清均检测为阴性,表明该方法具有较强的特异性;该方法可检测的最低中和抗体效价为14,与病毒中和试验的敏感性一致,表明该方法具有较高的敏感性;重复性试验显示该方法批内、批间变异系数均小于10%,显示较好的重复性。对130份现地牛血清检测结果显示,该方法与病毒中和试验的符合率为98.46%。用该方法对某牛场接种IBRV灭活疫苗的牛血清进行检测,抗体阳性率为99.51%(205/206)。另外,采用该方法对我国8个省(市、自治区)的801份牛血清进行检测,IBRV的抗体阳性率为41.6%(333/801)。本研究建立的阻断ELISA方法可以用于IBRV疫苗免疫监测和血清流行病学调查,为我国IBR的防控提供技术支持。  相似文献   

7.
An enzyme-linked immunosorbent assay (ELISA) was developed for the detection of antibodies to Mycobacterium paratuberculosis in the sera of cattle. This assay was designed to minimize the nonspecific ELISA reactions caused by immunoglobulin (Ig)M by measuring only IgG1 antibodies against a protoplasmic antigen from the organism. The ELISA detected IgG1 antibodies in the sera of 58% of cattle with positive fecal cultures for M paratuberculosis compared with detection of 45% of culture-positive animals with an immunodiffusion test. In addition to its sensitivity, the ELISA apparently is highly specific because only 4% of the sera from fecal culture-negative animals gave a false-positive result.  相似文献   

8.
The objective of this work was to use the ELISA technique for the serological surveillance for freedom of brucellosis of cattle, sheep and goats. By comparing 28 cattle sera taken after a brucellosis outbreak, 15 bovine sera supplied by the Federal Institute for Health Protection of Consumers and Veterinary Medicine (BgVV) and 497 serum slow agglutination test (SSAT) and complement fixation test (CFT) negative bovine sera from herds officially declared free of brucellosis, the ELISA technique not only shows higher sensitivity as compared to SSAT and CFT but also distinguishes clearly between positive and negative reactions. The serological comparison by SSAT, CFT and ELISA of 615 cattle, 624 sheep and 630 goat sera from herds acknowledged as brucellosis free showed equivalent specificities for both CFT and ELISA. The specificity of the SSAT was much lower, 81.1% in cattle and 96.2% in goat sera. The examination of 5796 cattle, 1337 calf, 5031 sheep and 1796 goat sera demonstrates the advantage of the ELISA technique as routine method. The possible application of the ELISA technique as a screening method for serological brucellosis tests in sheep, goats and possibly also in pigs is discussed.  相似文献   

9.
Outer sheath antigen was prepared from Leptospira interrogans serovars pomona, sejroe and hardjo by treating the organisms with 1.0M NaC1 followed by 0.04% sodium dodecyl sulfate (SDS). Sodium dodecyl sulfate was removed from the SDS-protein complexes by the extraction of dodecyl sulfate anions as ion pairs with triethylammonium cations into an organic solvent. The outer sheath antigen was recovered from the organic solvent as a precipitate and used as the source of leptospiral enzyme-linked immunosorbent assay (ELISA) antigen. Utilizing this antigen, ELISA was adapted to detect bovine serum antibody to L. interrogans serovars pomona, sejroe and hardjo. The specificity of this assay in 344 bovine sera, which were negative in the microscopic agglutination test (MAT) for seven serovars, was 99.4%. In sera from 37 and 87 cattle which revealed MAT titers greater than or equal to 1:50 for L. interrogans serovars pomona and sejroe, the relative sensitivity of the test was 100%. The ELISA also showed a considerable degree of low level cross-reactivity with other serovars. Sixty-six (75.9%) out of 87 bovine sera which were MAT-positive (MAT titer of greater than or equal to 1:50) with serovars sejroe and hardjo only were ELISA positive with heterologous pomona antigen; 16 (43.2%) and six 16.2%) out of 37 bovine sera which were MAT positive MAT titer of greater than or equal to 1:50) with serovar pomona only were ELISA positive with heterologous sejroe and hardjo ELISA antigen respectively.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

10.
Feces and blood were collected from cattle in 13 herds known to be infected with Mycobacterium paratuberculosis to evaluate a complement-fixation (CF) test, an agar gel immunodiffusion (AGID) test and an enzyme-linked immunosorbent assay (ELISA) for the serologic diagnosis of paratuberculosis. M. paratuberculosis was isolated from the feces of 36 of 192 cattle examined. Twenty-three culture-positive animals had CF test titers regarded as suspect or positive, 10 were positive by the AGID test and 34 were suspect or positive by the ELISA. Of the 156 culture-negative animals, the CF test agreed on 136, the ELISA on 129 and the AGID on 151.  相似文献   

11.
Five commercially available ELISA tests for the detection of antibodies against Mycobacterium avium subsp. paratuberculosis in bovine serum were evaluated at the individual animal level using sera from 286 paratuberculosis-free and 110 paratuberculosis-infected dairy cattle. Sensitivity (Se) and specificity (Sp) of the tests were estimated after determination of the cut-off dtheta by TG-ROC analysis or using the cut-off values recommended by the manufacturers, respectively. When the dtheta cut-off values were applied, the five ELISA tests showed sub-optimal Se and Sp. Adopting the cut-offs recommended by the manufacturers, the Sp of four of the five ELISA increased, two tests reaching Sp > or = 99.0%. Test sensitivity clearly depended on the disease state of the animals examined. Se was significantly higher in clinically diseased than in latently infected dairy cattle. Calculation of the positive and negative predictive values indicated that, depending on the test, a considerable proportion of false positive and false negative results have to be expected. Therefore, the suitability of antibody detection for the diagnosis of paratuberculosis in individual animals is questioned.  相似文献   

12.
The accuracy of 4 commercial enzyme-linked immunosorbent assays (ELISAs) for diagnosis of bovine paratuberculosis was compared using sera from 53 Mycobacterium avium subsp. paratuberculosis (MAP) fecal culture-positive dairy cows (cases) and sera from 345 dairy cattle resident in 11 fecal culture-negative herds on 2 consecutive occasions 1 year apart (controls). The specificity of all 4 ELISA kits was >99%, and their diagnostic sensitivity ranged from 30.2% to 41.5%. Pairwise comparison of ELISAs found no significant differences (McNemar's chi-square test > 0.05), and assay agreement for categorical assay interpretation (positive or negative) was high (>98%) with kappa values ranging from 0.84 to 0.95. Receiver operating characteristic (ROC) curve analysis and the corresponding area under the ROC curves indicate that kit B had the highest overall accuracy. Thus, all 4 ELISA kits for bovine paratuberculosis had comparable accuracy when tested on Chilean dairy cattle, with kit B having a slight statistical advantage based on ROC area under the curve analysis. This suggests that any of the 4 kits could be appropriate for herd certification and for paratuberculosis control programs on Chilean dairy cattle.  相似文献   

13.
Antibody to smooth Brucella abortus lipopolysaccharide antigen on the surface of polystyrene tubes was detected with peroxidase-labeled antibody against bovine immunoglobulin G. The enzyme-labeled antiglobulin test (ELAT) activity of samples was expressed in arbitrary units/0.01 ml by reference to a standard curve based on tests of dilutions of a positive serum pool. Reactions greater than 3.0 U/0.01 ml were classified positive because specificity at this level was 99.8% (417/418 samples correctly classified negative) with agglutination test-negative sera from 33 Brucella-free herds. Results of the ELAT were compared with results of agglutination tests and the complement-fixation test (CFT), using 430 sera from cattle in 7 infected herds. Activity of greater than 5.0 ELAT U/0.01 ml was detected in all 54 sera classified as positive (titer greater than 1:10) by the CFT, including 5 sera classified as negative by the tube agglutination test. Sera from 8 nonvaccinated cows in the infected herds reacted only by the ELAT, whereas reactions were obtained with 25 and 5 sera by only agglutination tests and the CFT, respectively. The ELAT and CFT results were in agreement for 25 of 26 sera from agglutination test-reactor cattle in herds of unknown status. Comparisons of milk ring and whey agglutination tests with the whey ELAT on 146 quarter samples from cows in an infected herd revealed no ELAT activity greater than or equal to 1.0 U/0.01 ml in the 73 samples considered negative by the 2 other tests. Samples (n = 47) that contained greater than or equal to 1.0 ELAT U/0.01 ml included all (n = 40) samples with milk ring or whey agglutination titers greater than or equal to 1:16 and greater than or equal to 32, respectively, and 7 samples that gave weaker reactions to the latter tests.  相似文献   

14.
A dot ELISA was developed for detection of antibodies to Mycobacterium paratuberculosis. The assay was evaluated by testing sera from cattle that were determined, by bacteriologic culturing of feces, to be infected with M paratuberculosis and were suspected of having clinical disease. Further evaluation involved testing sera from cattle in which M paratuberculosis had not been isolated from feces on several attempts. Results of the dot ELISA were positive for sera from 86 of 101 infected cattle, and results were negative for sera from 64 of 64 noninfected cattle. Results of conventional ELISA and agar gel immunodiffusion (AGID) tests were positive for 79 of 99 and for 51 of 101 infected cattle, respectively. The dot ELISA also was evaluated by comparing results of testing 708 sera with results of bacteriologic culturing of matched fecal samples from 262 cattle in 3 central Ohio dairy herds known to include cattle infected with M paratuberculosis. Results of the dot ELISA were positive for 25 of 39 sera from cattle with positive results on culturing of concurrently obtained fecal specimens. The dot ELISA results were negative for 661 of 669 sera from cattle with negative results to culturing of concurrently obtained fecal specimens. The 39 sera from cattle with positive results on bacteriologic culturing of matched fecal specimens had positive results for ELISA and the AGID test 25 and 14 times, respectively. The 669 sera from cattle with concurrently negative results on bacteriologic culturing of feces had negative results to ELISA and the AGID test 559 and 668 times, respectively.  相似文献   

15.
An indirect enzyme-linked immunosorbent assay (ELISA) for the detection of Brucella abortus antibodies in bovine bulk milk samples was evaluated. About 31 individual milk samples from B. abortus infected cows were diluted into bulk milk from a brucellosis free herd. Individual milk samples obtained from 96 negative or positive herds to ELISA or Brucella ring test (BRT), were tested by ELISA. All positive cows were bled and serum samples were tested by the complement-fixation test (CFT) which was considered the definitive test. A herd was considered infected if at least, one cow was positive in the CFT. Four samples were negative in the BRT at the dilution 1:10 but positive in the ELISA. For samples positive in both tests, BRT titers ranged from 1:10 to 1:480 while ELISA titers ranged from 1:10 to 1:3200.Using bulk milk samples, the sensitivity of the ELISA (98.1%) was higher than the BRT (72.2%) but the specificity of BRT (90.5%) was not statistically different (P=1.0) from the ELISA (88.1%). The implications of the results for brucellosis control are discussed.  相似文献   

16.
Three serological methods, the Rose-Bengal test (RBT), the complement-fixation test (CFT) and an indirect enzyme-linked immunosorbent assay (I-ELISA) were compared for the detection of Brucella-infected animals in unvaccinated cattle herds in Eritrea. In this study, 71 herds first were classified as positive or negative for Brucella infection on the basis of at least one animal being seropositive by RBT and CFT. All the 159 RBT-positive samples from the 26 seropositive herds and 214 RBT-negative samples randomly selected from the seropositive herds and from the 45 negative herds were tested further by CFT and I-ELISA. Using the ELISA titer as main predictor, and incorporating the RBT results, a logistic model was built to predict the CFT-negative or -positive status of individual sera and to estimate sensitivity and specificity. Whilst the ELISA titers (< or =20) accurately predicted all the negative sera in herds that were also negative by the CFT, the number of seropositive animals was higher by ELISA in herds that had positive animals. Serum samples which give higher degrees of agglutination with the RBT need not be re-tested with CFT; consideration of the seropositive status of a herd should be taken into consideration on defining the cut-off optical density readings for ELISA.  相似文献   

17.
OBJECTIVE: To determine the specificity of serological tests that are currently used in veterinary diagnostic laboratories in Australia for detection of Mycobacterium avium subsp paratuberculosis infection in goats. DESIGN: A laboratory study. PROCEDURE: Four tests were studied, comprising AGID with M. a. paratuberculosis antigen derived from cattle isolates of caprine or bovine origin, the EMAI caprine Johne's disease absorbed ELISA and the CSL PARACHEK Johne's absorbed EIA. The specificities of AGID and ELISA for paratuberculosis (Johne's disease) were estimated after examining a panel of 1000 serum samples collected from goats in Western Australia, a region free of paratuberculosis. In addition a comparison was made of test performance in a small number of paratuberculous goats from New South Wales using sera from two archival collections. RESULTS: The specificity of the AGID tests was 100% while the specificities of the two absorbed ELISA were 99.7 to 99.8% at appropriate positive-negative cut-offs. Based on testing the small sample of sera from infected goats, the absorbed ELISA tests detected about twice as many goats with Johne's disease as the AGID. Each test detected paratuberculous animals regardless of whether infection was caused by cattle or sheep strains of M. a. paratuberculosis. CONCLUSIONS: Both ELISA and AGID tests for paratuberculosis have high specificity and can be used in a market assurance program without risk of generating large proportions of false positive test results. However, the results suggested the ELISA is more sensitive for detection of infected goats and should be used in preference to the AGID. The two formats of ELISA evaluated in this study have similar characteristics and could be used in paratuberculosis control programs for the goat industries, but further data on sensitivity would increase confidence in their application.  相似文献   

18.
The collection of test sera for measuring ELISA results was composed of bovine sera with MAT titres of greater than or equal to 1:200 in the leptospirosis MAT and of greater than or equal to 1:5 in the CFT together with sera from a serologically negative and clinically non-suspicious cattle herd. To establish cut-off ODs, the geometric mean net-extinction of the negative serum collection plus 1, 2, and 3 standard deviations were calculated. By comparison of 3 different conjugates from rabbits, it was demonstrated that results from anti-total bovine Ig were superior to anti-IgG and anti-IgM conjugates. Considerations regarding sensitivity and specificity led to the recommendation to use a test serum dilution of 1:160, to apply anti-total bovine Ig conjugates, and to establish the cut-off OD at the geometric mean net-extinction of negative sera plus 3 standard deviations. Under such conditions, agreement between leptospirosis MAT/CFT positivity on the one side and ELISA positivity on the other was reached in 74%. This recommendation is made for cross-sectional studies but not for examinations of clinically suspicious cattle herds.  相似文献   

19.
An enzyme-linked immunosorbent assay (ELISA) was used to measure specific antibody activity from a single serum dilution in sera of chickens exposed to Newcastle disease virus (NDV). Observed endpoint titers were used to formulate regression equations, and then absorbance data obtained at a single serum dilution were converted directly to antibody titer by three methods: a correction factor method, a subtraction method, and a double-regression method. Each method was evaluated for three criteria: the overall stability of between-test antibody titer for control sera, the linearity of the relationship of the absorbance values at a single working dilution to the observed antibody titers, and the method's accuracy in predicting titers. Although a nearly linear relationship was obtained for all treatment methods examined, the double-regression method provided the best reduction of between-test titer variation and also best predicted titers.  相似文献   

20.
The sensitivity of an indirect enzyme-linked immunosorbent assay (ELISA) for bovine IgG serum antibody to Pasteurella haemolytica was compared with that of an indirect hemagglutination (IHA) test. Pasteurella haemolytica serotypes were grown in a chemically defined cell culture medium, and soluble antigens released into the growth medium were used in the ELISA and IHA test. An ELISA with serotype-1 antigen consistently detected antibody in sera that were positive by IHA test (correlation, 99%). Sera reacting with serotype-1 ELISA antigens also reacted with ELISA antigens prepared from other serotypes. Although ELISA titers averaged 5 log2 units higher than IHA titers, plots of titers determined by the 2 methods were approximately linear. Titer increases detected in paired serum samples by either test were similar. The ELISA was more sensitive than was the IHA in detecting colostral IgG antibody in serum of newborn calves. The ELISA uses a simple, stable antigen preparation and detects antibody to P haemolytica serotypes that commonly infect cattle.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏