相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Objective – To determine the accuracy and precision of an oscillometric noninvasive blood pressure device as a predictor of invasive direct blood pressure in healthy anesthetized hypotensive and normotensive dogs. Design – Prospective observational study. Setting – University teaching hospital. Animals – Eight crossbred adult dogs. Interventions – Anesthesia was induced with propofol and maintained with isoflurane. A catheter was placed in the dorsal pedal artery to record systolic, mean, and diastolic arterial blood pressures (aSAP, aMAP, and aDAP, respectively). The noninvasive blood pressure device cuff was placed around the contralateral front limb to record noninvasive systolic, mean, and diastolic blood pressure (nSAP, nMAP, and nDAP). Two states of blood pressure (BP) were studied: baseline state was established by keeping end‐tidal isoflurane concentration at 1.2±0.1%. The hypotensive state was achieved by maintaining the same isoflurane concentration while withdrawing approximately 40% of the animal's blood volume until aMAP was stable at approximately 40 mm Hg. At the end of the study, blood was returned to the animal and it was allowed to recover from anesthesia. Measurements and Main Results – Agreement between the direct and indirect BP measurements was determined by the Bland‐Altman method. The SAP and MAP but not DAP bias varied significantly between each BP state. Normotensive absolute biases (mean [SD]) for SAP, MAP, and DAP were ?14.7 mm Hg (15.5 mm Hg), ?16.4 mm Hg (12.1 mm Hg), and ?14.1 mm Hg (15.8 mm Hg), respectively. Absolute biases during the hypotensive state for SAP, MAP, and DAP were ?32 mm Hg (22.6 mm Hg), ?24.2 mm Hg (19.5 mm Hg), and ?16.8 mm Hg (17.2 mm Hg), respectively. Conclusion – The oscillometric device was not reliably predictive of intra‐arterial BP during hypotension associated with acute hemorrhage.  相似文献   

2.
ObjectiveTo evaluate the agreement between invasive blood pressure (IBP) and Doppler ultrasound blood pressure (DUBP) using three cuff positions and oscillometric blood pressure (OBP) in anesthetized dogs.Study designProspective study.AnimalsNine adult dogs weighing 14.5–29.5 kg.MethodsThe cuff was placed above and below the tarsus, and above the carpus with the DUBP and above the carpus with the OBP monitor. Based on IBP recorded via a dorsal pedal artery catheter, conditions of low, normal, and high systolic arterial pressures [SAP (mmHg) <90, between 90 and 140, and >140, respectively] were induced by changes in isoflurane concentrations and/or dopamine administration. Mean biases ± 2 SD (limits of agreement) were determined.ResultsAt high blood pressures, regardless of cuff position, SAP determinations with the DUBP underestimated invasive SAP values by more than 20 mmHg in most instances. With the DUBP, cuff placement above the tarsus yielded better agreement with invasive SAP during low blood pressures (0.2 ± 16 mmHg). The OBP underestimated SAP during high blood pressures (?42 ± 42 mmHg) and yielded better agreement with IBP for mean (MAP) and diastolic (DAP) arterial pressure measurements [overall bias: 2 ± 15 mmHg (MAP) and 0.2 ± 16 mmHg (DAP)].ConclusionsAgreement of SAP determinations with the DUBP is poor at SAP > 140 mmHg, regardless of cuff placement. Measurement error of the DUBP with the cuff placed above the tarsus is clinically acceptable during low blood pressures. Agreement of MAP and DAP measurements with this OBP monitor compared with IBP was clinically acceptable over a wide pressure range.Clinical relevanceWith the DUBP device, placing the cuff above the tarsus allows reasonable agreement with IBP obtained via dorsal pedal artery catheterization. Only MAP and DAP provide reasonable estimates of direct blood pressure with the OBP monitor evaluated.  相似文献   

3.
Adaptation of human oscillometric blood pressure monitors for use in dogs   总被引:2,自引:0,他引:2  
Two digital oscillometric human blood pressure measuring devices were modified and evaluated as blood pressure monitors in 12 healthy anesthetized dogs. Direct arterial pressures were measured via cannulation of the dorsal pedal artery and were correlated with indirect measurements through an inflatable cuff placed over the dorsal pedal artery below the hock joint of the contralateral limb. Direct and indirect measurements were compared for systolic, diastolic, and calculated mean arterial pressures. Blood pressure ranges between 215/145 mm of Hg and 65/30 mm of Hg were obtained, using combinations of halothane, phenylephrine, calcium, and IV administered fluids. Machine A was found to be insufficient for clinical application, on the basis of correlation coefficients between direct and indirect pressures of 0.78, 0.65, and 0.74 for systolic, diastolic, and mean arterial pressures, respectively. Higher correlation coefficients between direct and indirect pressures (0.77, 0.87, and 0.87, respectively) were obtained with machine B. The results of the study reported here suggest machine B may be an effective blood pressure monitoring device in anesthetized dogs.  相似文献   

4.
ObjectiveTo compare Doppler and oscillometric methods of indirect arterial blood pressure (IBP) with direct arterial measurements in anesthetized and awake red-tailed hawks.Study designProspective, randomized, blinded study.AnimalsSix, sex unknown, adult red-tailed hawks.MethodsBirds were anesthetized and IBP measurements were obtained by oscillometry (IBP-O) and Doppler (IBP-D) on the pectoral and pelvic limbs using three cuffs of different width based on limb circumference: cuff 1 (20–30% of circumference), cuff 2 (30–40%), and cuff 3 (40–50%). Direct arterial pressure measurements were obtained from the contralateral superficial ulnar artery. Indirect blood pressure measurements were compared to direct systolic arterial pressure (SAP) and mean arterial pressure (MAP) during normotension and induced states of hypotension and hypertension. Measurements were also obtained in awake, restrained birds. Three-way anova, linear regression and Bland–Altman analyses were used to evaluate the IBP-D data. Results are reported as mean bias (95% confidence intervals).ResultsThe IBP-O monitor reported errors during 54% of the measurements. Indirect blood pressure Doppler measurements were most accurate with cuff 3 and were comparable to MAP with a bias of 2 (?9, 13 mmHg). However, this cuff consistently underestimated SAP with a bias of 33 (19, 48 mmHg). Variability in the readings within and among birds was high. There was no significant difference between sites of cuff placement. Awake birds had SAP, MAP and diastolic arterial pressure that were 56, 43, and 38 mmHg higher than anesthetized birds.Conclusions and clinical relevanceIndirect blood pressure (oscillometric) measurements were unreliable in red-tailed hawks. Indirect blood pressure (Doppler) measurements were closer to MAP measurements than SAP measurements. There was slightly better agreement with the use of cuff 3 on either the pectoral or pelvic limbs. Awake, restrained birds have significantly higher arterial pressures than those under sevoflurane anesthesia.  相似文献   

5.
ObjectiveTo determine the accuracy of an oscillometric blood pressure monitor in anesthetized sheep.Study designProspective study.AnimalsTwenty healthy adult sheep, 11 males and nine females, weighing 63.6 ± 8.6 kg.MethodsAfter premedication with buprenorphine or transdermal fentanyl, anesthesia was induced with ketamine‐midazolam and maintained with isoflurane and ketamine, 1.2 mg kg?1 hour?1, ± lidocaine, 3 mg kg?1 hour?1. Invasive blood pressure measurements were obtained from an auricular arterial catheter and noninvasive measurements were from a cuff on the metatarsus or antebrachium. Simultaneous invasive and noninvasive measurements were recorded over a range (55–111 mmHg) of mean arterial pressures (MAP). Isoflurane concentration was increased to decrease MAP and decreasing the isoflurane concentration and infusing dobutamine achieved higher pressures. Invasive and noninvasive measurements were compared.ResultsCorrelation (R2) was good between the two methods of measurement (average of three consecutive readings) for systolic (SAP) (0.87), diastolic (DAP) (0.86), and mean (0.90) arterial pressures (p < 0.001). Bias ± SD between noninvasive and invasive measurements for SAP was 3 ± 8 mmHg, for DAP was ?10 ± 7 mmHg, and MAP was ?7 ± 6 mmHg. There was no significant difference between the average of three measurements and use of the first measurement. Correlations using the first measurement were SAP (0.82), DAP (0.84), and MAP (0.89). Bias ± SD for SAP was 3 ±10 mmHg, for DAP was ?11 ± 7 mmHg, and MAP was ?7 ± 6 mmHg. The oscillometric monitor slightly overestimated SAP and underestimated DAP and MAP for both average values and the first reading.Conclusions and clinical relevanceThis oscillometric model provided MAP measurements that were acceptable by ACVIM standards. MAP measurements with this monitor were lower than those found with the invasive technique so a clinical diagnosis of hypotension may be made in sheep that are not hypotensive.  相似文献   

6.
OBJECTIVE: To examine the agreement between direct arterial blood pressure measurements obtained from 2 arteries and indirect blood pressure measurements obtained with an oscillometric blood pressure monitor (OBPM) during normotension and phenylephrine-induced hypertension in dogs. ANIMALS: 16 male Beagles. PROCEDURES: In anesthetized dogs, arterial catheters were placed in the lingual and dorsal pedal arteries for measurement of arterial blood pressure. A blood pressure cuff was placed on either the dog's fore- or hind limb and connected to an OBPM. Systolic, diastolic, and mean arterial blood pressures (SAP, DAP, and MAP, respectively) were recorded from both arteries and the OBPM every 5 minutes for 30 minutes (baseline), during a 30-minute period in which dogs received a phenylephrine infusion IV to induce hypertension, and for 30 minutes after discontinuation of the infusion. Mean differences in blood pressure values and confidence intervals were calculated to compare the indirect and direct measurement techniques. RESULTS: In dogs, oscillometry underestimated SAP during normotension, and the difference between oscillometric and direct measurements increased during hypertension. Oscillometry underestimated DAP, but the difference between oscillometric and direct measurements decreased during hypertension. There was close agreement among techniques for MAP determinations. Biases between direct measurements and OPBM blood pressure values measured from dogs' forelimbs or hind limbs were not significantly different. CONCLUSIONS AND CLINICAL RELEVANCE: In normotensive dogs, oscillometric measurements of MAP and SAP agreed more closely with direct arterial pressure measurements than oscillometric estimates of DAP. Oscillometric measurement of MAP was accurate during both normotension and hypertension in dogs.  相似文献   

7.
Objective —To determine the accuracy of three indirect blood pressure monitoring techniques (oscillometric technique [OS], Doppler [DOP], and optical plethysmography [OP] [blood pressure determined with a pulse oximeter waveform]) when compared with direct arterial pressure measurement in cats. Study Design —Prospective study. Animal Population —Eight healthy (five female, three male), domestic short-hair cats, weighing 3.5 ± 0.8 kg Methods —Cats were anesthetized with isoflurane. The inspired concentration of isoflurane was adjusted to produce mild hypotension (80 to 100 mm Hg direct systolic), moderate hypotension (60 to 80 mm Hg direct systolic), and severe hypotension (<60 mm Hg direct systolic). Indirect pressure measurements were obtained from the thoracic limb and compared with concurrent direct measurement using regression analysis and a modification of Bland and Altman's technique. Results —All three techniques underestimated systolic pressure. OS produced the best prediction of systolic pressure with a bias ± precision of -15.9 ± 8.1 mm Hg. DOP and OP were relatively inaccurate with a bias ± precision of -25 ± 7.4 mm Hg and -25 ± 7.5 mm Hg. All three techniques correlated well with direct pressure with r values of 0.81, 0.88, and 0.88 for OS, DOP, and OP. DOP and OP provided an accurate prediction of direct mean arterial pressure with a bias ± precision of -0.8 ± 6 mm Hg and 0.6 ± 5.5 mm Hg. Correlation was good between DOP and mean arterial pressure with r = 0.89. Correlation was also good between OP and mean arterial pressure with r = 0.90. Conclusions —OS provided the most accurate prediction of direct systolic pressure. DOP and OP provided a good prediction of mean arterial pressure in the cat. Clinical Relevance —All three of these techniques are useful for detecting trends. Direct monitoring of blood pressure should be considered if accurate blood pressure measurement is required.  相似文献   

8.
OBJECTIVE: To determine accuracy of an oscillometric blood pressure monitor used over a wide range of pressures in anesthetized cats. DESIGN: Prospective study. ANIMALS: 6 healthy cats. PROCEDURE: 4 female cats and 2 male cats that weighed 2.7 to 4.5 kg (5.9 to 9.9 lb) and were 2 to 8 years old were anesthetized. Blood pressure was measured directly with an arterial catheter placed in the right femoral artery and indirectly from the left antebrachium by use of an oscillometric monitor. A series of diastolic arterial pressure (DAP), mean arterial pressure (MAP), and systolic arterial pressure (SAP) measurements were obtained during hypotension, normotension, and hypertension. Values obtained indirectly and directly were compared. RESULTS: The oscillometric monitor was accurate for DAP and MAP throughout the entire pressure range and met the standards of the Association for the Advancement of Medical Instrumentation (mean +/- SD difference from values obtained directly, < or = 5 +/- 8 mm Hg). The SAP was increasingly underestimated with increasing overall pressure; mean differences from direct measurements were -5.2, -12.1, and -17.7 mm Hg during hypo-, normo-, and hypertension, respectively. Standard deviations for SAP were all < or = 8 mm Hg. The monitor gave readings during all attempts. The direct blood pressure recording system appeared to perform well with neither under- nor overdamping. CONCLUSIONS AND CLINICAL RELEVANCE: Except for a minor underestimation of SAP during normo- and hypertension, the oscillometric monitor yielded reliable and easily obtainable blood pressure measurements in anesthetized cats.  相似文献   

9.
The precision and accuracy of an indirect oscillometric blood pressure measurement technique (Dinamap 8100) was assessed in 11 anesthetized Beagle dogs weighing 8 to 11.5 kg. Direct blood pressure measurements were made by catheterization of the lingual artery, and simultaneous indirect measurements were determined by placing a cuff over the median artery (midradial area). Blood pressure measurements at 2 different planes of anesthesia (light and deep) were recorded in triplicate. At a light plane of anesthesia, the Dinamap 8100 underestimated diastolic and mean arterial pressure, and at a deep anesthetic plane overestimated systolic pressure. The indirect technique had good repeatability of systolic pressures. Regression analysis for the 2 techniques showed excellent correlation (r = 0.93). The results indicate that the indirect oscillometric blood pressure measurement technique provides a good estimate of systolic, diastolic, and mean arterial pressure in dogs weighing 8-11.5 kg.  相似文献   

10.
Objective – To compare blood pressure measurements obtained via ultrasonic Doppler flow monitor (DOP) and 2 oscillometric noninvasive blood pressure monitors (CAR and PAS) to invasive blood pressure (IBP) in hospitalized, conscious dogs with a range of blood pressures. Design – Prospective clinical study. Setting – University teaching hospital. Animals – Eleven client‐owned dogs aged between 4 months and 11.5 years (median 6 y), and weighing between 5.8 and 37.5 kg (median 30.2 kg). Interventions – Blood pressure measurement. Measurements and Main Results – Three consecutive measurements of systolic, diastolic, and mean arterial pressure (MAP) were recorded for each of the 3 indirect devices (only systolic for DOP), along with concurrent IBP measurements. The data were categorized into 3 groups: hypotensive (direct MAP<80 mm Hg), normotensive (80 mm Hg≤direct MAP≥100 mm Hg), and hypertensive (direct MAP>100 mm Hg). Each indirect method was compared with the corresponding direct arterial pressure using the Bland‐Altman method. Within the hypotensive group, each indirect method overestimated the corresponding IBP. Within the normotensive group all indirect systolic measurements and the PAS diastolic measurements underestimated the corresponding IBP. The remaining indirect measurements overestimated the corresponding IBP. Within the hypertensive group, DOP and CAR systolic measurements underestimated the corresponding IBP, and the remaining indirect measurements overestimated the corresponding IBP. In hypertensive dogs oscillometric systolic measurements were more accurate than MAP. In hypotensive dogs MAP measurements were more accurate than systolic measurements. All indirect measurements were most accurate in hypertensive dogs. Conclusions – The noninvasive blood pressure monitors in our study did not meet the validation standards set in human medicine. However, CAR diastolic and MAP measurements within the normotensive group, CAR MAP measurements within the hypertensive group, and PAS diastolic measurements in all groups were close to these standards. All indirect measurements showed greater bias during hypotension. Precision was poorer for all indirect systolic measurements than for MAP.  相似文献   

11.
Objective: To determine the accuracy of indirect blood pressure (BP) measurements obtained with a pulse oximeter as compared with direct measurements in dogs under isoflurane anesthesia. The Doppler and oscillometric BP monitors were included for comparison. Design: Prospective, experimental study. Animals: Twenty healthy dogs (23 ± 8 kg) anesthetized for research or teaching. Interventions: Dogs were anesthetized with propofol or thiopental and maintained using positive pressure ventilation with isoflurane in 100% O2. Random adjustment of BP was achieved by inhalant adjustment or dopamine infusion to achieve low (≤85 mmHg), normal (90–120 mmHg), or high systolic BP (≥125 mmHg). Triplicate measurements for BP were taken with direct (dorsal pedal artery), Doppler (forelimb), oscillometric (same forelimb), and plethysmographic (pulse oximeter on tongue) methods. Measurements and main results: Using regression analysis and a modified Bland–Altman's technique, the lowest bias was achieved with the Doppler. Systolic BP readings at low, normal, and high BP were within 10 mmHg of direct recordings 95%, 70%, and 30% of the time for pulse oximetry; 95%, 85%, and 55% of the time for Doppler; 42%, 65%, and 30% of the time for oscillometric determination, respectively. Oscillometric mean BP readings were within 10 mmHg of direct measurements 53%, 60%, and 45% of the time, respectively. Conclusions: The pulse oximeter is an acceptable method for measuring BP in anesthetized dogs if assessment of trends is sufficient. All indirect methods showed greater bias and poorer precision at high BP. The Doppler may be the preferred indirect method.  相似文献   

12.
ObjectiveTo evaluate the agreement between oscillometric blood pressure (OBP) measured from the tongue and invasive blood pressure (IBP), and to compare OBPs measured from the tongue with OBPs measured from the pelvic limb and tail.Study designProspective experimental study.AnimalsA total of eight adult Beagle dogs weighing 11.1 ± 1.2 kg.MethodsAnimals were premedicated with intravenous (IV) acepromazine (0.005 mg kg–1). Anesthesia was induced with alfaxalone (3 mg kg–1) IV and maintained with isoflurane. The dorsal pedal artery was catheterized for IBP measurements. Systolic (SAP), diastolic (DAP) and mean (MAP) arterial pressure were simultaneously measured from the tongue, pelvic limb and tail. Based on invasive SAP, hypertension (>140 mmHg), normotension (90–140 mmHg) and hypotension (<90 mmHg) were induced by controlling end-tidal isoflurane concentrations and/or dobutamine/dopamine administration. Agreement between paired IBP and OBP measurements was analyzed with reference standards for noninvasive blood pressure devices used in small animals and humans.ResultsRegardless of cuff placement, the mean bias ± standard deviation between IBP and OBP met veterinary (≤10 ± 15 mmHg) and human (<5 ± 8 mmHg) standards for MAP and DAP. SAP measurements provided by the OBP device showed unacceptable agreement with IBP, and the bias between methods increased at higher blood pressures, regardless of cuff site. During hypotension, tongue OBP showed the largest percentage of absolute difference <10 mmHg in relation to IBP for SAP (90%), MAP (97%), and DAP (93%), compared with pelvic limb (60%, 97% and 82%, respectively) and tail OBP (54%, 92% and 77%, respectively).Conclusions and clinical relevanceThe tongue is a clinically useful site for measuring OBP in anesthetized Beagle dogs, providing reliable estimates of MAP and DAP. The tongue could replace other cuff placement sites and may be a relatively suitable site for assessing hypotension.  相似文献   

13.
Blood pressure (BP) measurements obtained using 3 indirect BP measuring instruments, a Doppler ultrasonic flowmeter, an oscillometric device, and a photoplethysmograph, were compared with direct arterial pressure measurements in 11 anesthetized cats. The standard deviation of the differences (SOD) between direct and indirect pressure measurements were not significantly different from each other ( P <.01), and ranged from 10.82 to 24.32 mm Hg. The high SDD values indicate that indirect BP estimates obtained with all these devices must be interpreted cautiously in individual patients. The mean errors (calculated as the sum of the differences between direct and indirect pressure measurements divided by the number of observations) of the 3 indirect devices were significantly different for systolic (SAP), diastolic (DAP), and mean (MAP) arterial pressures ( P <.05). The Doppler and photoplethysmographic devices had the highest overall accuracy, as indicated by mean error values of less than 10 mm Hg. Correlation coefficients varied from .88 to .96 for the Doppler flowmeter, and from .85 to .94 for the photoplethysmograph; for both devices, the regression line slopes were close to unity. The Doppler flowmeter detected a pulse under all experimental conditions. The photoplethysmograph was also efficient in obtaining BP measurements, obtaining over 90% of SAP, DAP, and MAP readings attempted. The oscillometric device was the least accurate, with mean error values varying from 10 to 22 mm Hg. Correlation coefficients were high (.90 to .94) for this device, but the slopes of the regression lines were 0.7 to 0.8, indicating a trend for increased error at higher BP. The oscillometric device tended to underestimate BP by increasing amounts as the BP increased. The oscillometric device was the least efficient device for obtaining BP measurements ( P <.01).  相似文献   

14.
ObjectiveTo determine the agreement of high definition oscillometry (HDO) with direct arterial blood pressure measurements in normotensive, hypotensive and hypertensive horses during general anaesthesia.Study designExperimental study.AnimalsSeven healthy warmblood horses, aged 3–11 years, weighing 470–565 kg.MethodsMeasurements from a HDO device with the cuff placed around the base of the tail were compared with pressures measured invasively from the facial artery. High blood pressures were induced by intravenous (IV) administration of dobutamine (5 μg kg−1 minute−1) over ten minutes followed by norepinephrine (0.1 mg kg−1 IV) and low pressures by increasing the inspired fraction of isoflurane and administration of nitroglycerine (0.05 mg kg−1 IV). For analysis three pressure levels were determined: high (MAP>110 mmHg), normal (60 mmHgResultsA total of 245 paired measurements of systolic (SAP), mean (MAP) and diastolic (DAP) pressures were obtained. The HDO device underestimated blood pressure at hypertensive and normotensive levels and overestimated blood pressure at hypotensive levels. Best agreement was obtained for SAP and MAP within normotensive limits. At normotension, bias ± standard deviation for SAP, MAP and DAP were 0.1 ± 19.4 mmHg, 0.5 ± 14.0, 4.7 ± 15.6, respectively. At high pressure levels bias and SD were 26.1 ± 37.3 (SAP), 4.2 ± 19.4 (MAP), 1.5 ± 16.8 (DAP) and at low pressures -20.0 ± 20.9 (SAP), -11.4 ± 19.6 (MAP), -4.7 ± 20.1 (DAP), with HDO measurements at a MAP <50 mmHg often failing.Conclusion and clinical relevanceGood agreement with invasive arterial blood pressures was obtained with HDO at normotensive levels in horses. At high and low pressure ranges HDO was unreliable. Therefore, if haemodynamic instability is expected, invasive measurement remains preferable.  相似文献   

15.
ObjectiveTo assess the agreement between an oscillometric device and invasive blood pressure (IBP) measurements in anesthetized healthy adult guinea pigs.Study designProspective experimental study.AnimalsA total of eight adult Hartley guinea pigs.MethodsAll animals were anesthetized; a carotid artery was surgically exposed and catheterized for IBP measurements. A size 1 cuff placed on the right thoracic limb was connected to an oscillometric device for noninvasive blood pressure (NIBP) assessment. Concurrent pairs of systolic (SAP), diastolic (DAP) and mean (MAP) arterial pressures were recorded simultaneously with both methods every 3 minutes for 30 minutes. Agreement between IBP and NIBP measurements was determined using the Bland–Altman method, considering the recommended standards for the validation of NIBP measurement devices proposed by the American College of Veterinary Internal Medicine (ACVIM).ResultsThe bias and the 95% limits of agreement were: –14 (–31 to 3) mmHg, –2 (–14 to 10) mmHg and –1 (–13 to 11) mmHg for SAP, DAP and MAP, respectively.Conclusions and clinical relevanceThe oscillometric device used in this study to measure NIBP did not meet ACVIM criteria for validation. It showed good agreement for DAP and MAP but not for SAP measurements. Considering the small size of these animals and the resulting difficulty in performing percutaneous arterial catheterization, this device might be a useful tool to assess MAP and DAP during anesthetic procedures in adult guinea pigs.  相似文献   

16.
Objectives — (1) To determine the usefulness of one specific oscillometric monitor for making indirect measurements of arterial pressure in cats. (2) To determine the difference between two specific cuff placement sites. (3) To determine if clipping the hair beneath the cuff has an affect on the accuracy of oscillometric blood pressure determination.
Study Design — Prospective study comparing the accuracy of the Datascope Passport (Data-scope Corp, Paramus, NJ) with concurrent invasive measurements.
Animals — Six anesthetized domestic felines weighing 4.5 to 5 kg.
Methods — The direct arterial pressure was measured using a cannula placed in the right common carotid artery. Oscillometric cuffs of appropriate size were placed on both thoracic limbs distal to the elbow and both pelvic limbs distal to the stifle. The hair in the areas of cuff placement on the right limbs was clipped circumferentially. Measurements of systolic, diastolic, and mean arterial pressure (MAP) were taken for each site during normotension, hypotension, and hypertension. Comparisons between indirect and direct measurements were made using a parametric analysis of method comparison.
Results — No significant differences were noted when die clipped limbs were compared with the corresponding limbs which were left undipped ( P >.378) or when the thoracic limb measurements were compared widi those of the pelvic limb ( P >.088). There were significant differences ( P <.002) between the two pressure measurement methods for the systolic, diastolic, and mean arterial pressures over all three pressure ranges.
Conclusions — The Datascope Passport did not accurately estimate the invasively measured arterial pressure.
Clinical Relevance — Use of noninvasive blood pressure monitoring equipment is increasing in use in veterinary medicine, and the accuracy of one specific monitor is reported.  相似文献   

17.
Objective: To investigate the agreement between indirect oscillometric and direct blood pressure measurement in the equine neonate. Design: Prospective observational study. Setting: University Veterinary Teaching Hospital. Animals: Ten crossbred foals of 30–46 hours of age. Interventions: Six animals (Group 1) were anesthetized. Four animals (Group 2) were restrained on a mat. All animals were instrumented with a catheter in the greater metatarsal artery and an oscillometric blood pressure cuff over the coccygeal artery. Blood pressure was varied with dobutamine, phenylephrine, nitroprusside, and increased depth of anesthesia (Group 1) or dopamine (Group 2). Measurements and main results: Simultaneous direct and indirect blood pressure measurements were obtained from the greater metatarsal artery and the coccygeal artery, respectively. There was good agreement between the 2 methods for mean and diastolic blood pressures in both groups, but not for systolic pressure. The agreement was best in mean blood pressure of anesthetized foals (mean bias –1.07; limits of agreement – 9.39, 7.25 mmHg). Conclusions: Indirect oscillometry appears to be an acceptable method for measuring mean arterial blood pressure in both anesthetized and conscious neonatal foals, and may be a valid method of monitoring critically ill foals.  相似文献   

18.
Objective The objective of this study was to compare an implanted direct blood pressure monitor and a non‐invasive oscillometric unit for use in anesthetized and awake green iguanas. Study design Prospective experimental trial. Animals Four male and four female adult green iguanas (Iguana iguana) weighing 1833 ± 534 g. Methods For each animal, the carotid artery was surgically exposed and the catheter tip of the pressure transducer was placed in the aortic arch. Non‐invasive blood pressure was measured using a cuff over the left femoral region. Pulse rate, respiratory rate and arterial blood pressure (ABP) measurements were taken every 5 minutes. Direct ABP measurements consisted of recording numerical values and graphic output. Simultaneous direct and indirect measurements were repeated in awake animals. Results The oscillometric device failed to provide a reading in over 80% of attempts, and failed to provide readings that correlated with direct measurements. The implanted direct transducer was capable of detecting blood pressures throughout all ABP ranges examined. Conclusions The implantable transducer was a reliable means of determining blood pressure in this study, while the oscillometric device was unreliable and often failed to provide any reading. Clinical relevance We do not recommend using the oscillometric device as described in a research or clinical setting for green iguanas. The advantages of an implantable device include the ability to monitor awake and anesthetized subjects remotely and continuously. These monitors are small, biocompatible and function across a wide range of ABP.  相似文献   

19.
The accuracy of the Doppler technique for indirect systolic blood pressure measurement was assessed in 16 anesthetized cats. Eight cats were anesthetized with isoflurane and 8 were anesthetized with halothane. Anesthetic depth and mode of ventilation were varied to obtain a wide range of arterial blood pressure. A Doppler transducer was placed on the palmer surface of the left forelimb over the common digital branch of the radial artery to detect blood flow, and a blood pressure monitoring cuff with a width 37% the limb circumference was placed half way between the elbow and the carpus. To enable direct arterial pressure measurements, the left femoral artery was catheterized and the blood pressure waveforms recorded simultaneously. Systolic blood pressure measured by use of the Doppler ultrasonic technique was significantly lower than that obtained from the femoral artery catheter. Using linear regression, we determined a clinically useful calibration adjustment for Doppler indirect blood pressure measurement in cats: femoral systolic pressure = Doppler systolic pressure + 14 mm of Hg.  相似文献   

20.
ObjectiveTo assess agreement between carotid arterial pressure and auricular arterial, thoracic limb Doppler or thoracic limb oscillometric blood pressure measurements.Study designProspective experimental study.AnimalsSix adult New Zealand white rabbits.MethodsRabbits were anesthetized with isoflurane in oxygen at 1, 1.5 and 2 MAC on two separate occasions. Catheters in the auricular and the contralateral external carotid artery were connected to calibrated pressure transducers via non-compliant tubing. Inflatable cuffs of width equal to approximately 40% of the limb circumference were placed above the carpus on both thoracic limbs with a Doppler transducer placed distal to the cuff on one. Systolic (SAP) and mean (MAP) arterial blood pressure measurements were obtained at each dose, on each occasion. Agreement between measurement techniques was evaluated by repeated measures Bland Altman analysis with carotid pressure as the reference. Variation in bias over the measurement range was evaluated by regression analysis.ResultsCarotid MAP and SAP ranged from 20 to 65 mmHg and 37 to 103 mmHg respectively. Bias and 95% limits of agreement for auricular and oscillometric MAP were 7 (0–14) and ?5 (?21–11) mmHg, respectively, and for auricular, oscillometric and Doppler SAP were 23 (8–37), ?2 (?24–20) and 13 (?14–39) mmHg, respectively. Bias varied significantly over the measurement range (p < 0.001) for all three SAP techniques but not for MAP measurements.Conclusions and clinical relevanceLimits of agreement for all measurements were large but less so for MAP than SAP. Variation in bias with SAP should be considered when using these measurements clinically.  相似文献   