首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 23 毫秒
1.
The equivalent transmission line method is extended to multi-transverse electric modes of cavity which are introduced by aperture coupling, and it is used to analyze the shielding effectiveness of rectangular enclosures with apertures. The multimode transmission line method is verified by HFSS(High Frequency Structure Simulator). The results show that higher-order mode is essential to obtain an accurate shielding effectiveness of rectangular enclosure on wide frequency domain. Below the frequency of 1 GHz, nearer to the slot, the impact of higher-order mode on the shielding effectiveness is greater in the place mear the slot. Higher-order mode leads to a better shielding effectiveness.  相似文献   

2.
Transient analysis of transmission line has recently been received more attention because operating speeds in high-speed digital electronics are increasing. Transmission line equations are hyperbolic partial differential equations, firstly this paper deduces how to change transmission line equations into quasilinear differential equations , thus the transmission line equation numerical result is gotten by computing the differential formation of quasilinear differential equations. The constraint of voltage and current is be considered and lumped equivalent circuit mode at boundary network collaborated at the same time in finding boundary conditions. Finally the paper computes transient response of transmission line with two typical boundary conditions. Numerical result shows that this approach is an effective way. It is explicit algorithm with less CPU consumption which can get time field response directly. The agree-upon effective way does be frequency field method, however it could not get time response unless the numerical inverse laplace transformation (NILT) be introduced. Thus this approach is more effective than FFT algorithm.  相似文献   

3.
For separate transmission of received data and current fuze status data in a paasive setting system, a dual channel transmission method based on LSK and PSK is proposed. The corresponding feedback transmission model is set up. The methods for circuit realization and circuit parameters selection are also presented. This method has the advantage of easy circuit realization, low energy consumption, and quick and reliable information feedback. The test shows it can realize the stable dual feedback of 6.25 kbps setting data and 50 kbps status data of fuze in the same wireless channel when the DC voltage is not lower than 3 V. The design and modulation of principal prototype have been completed.  相似文献   

4.
In order to calculate and analyze the effect of two transmission lines in parallel on the reliability evaluation of bulk power system, a model including independent outage, common mode outage and dependent outage of these lines is deduced and a new algorithm corresponding to the model is presented. Two transmission lines in parallel including common mode outages and dependent outages can be really simulated as a multi-state component. While reliability indices are calculated, the probability and frequency of independent outage, common mode outage and dependent outage of a system failure state can be calculated at the same time, and computation complexity is reduced. The proposed model and algorithm are applied to the RBTS system, IEEE One Area RTS96 system and a real power system for reliability computation and analysis. Results show that the new algorithm is credible and validity.  相似文献   

5.
The main means of the voltage-reactive power control of substation are adjusting the taps of load-tap-changing transformer or the reasonable capacity of parallel compensating capacitors according to the operation condition of substation.The "nine-area control strategy" is widely used to adjust voltage in the stated range and reduce the transmission capability of reactive power for power system at present.By analyzing the existent shortages of nine-area control mode for voltage-reactive power,an adjusting voltage calculation method is put forward,input data of which are the real time data of current,voltage and power of the substation.Then operation decision of voltage-reactive power control method of substation is made.By the simulating analysis,predigesting method of upper system is built,based on which an applied real time calculating model and calculating steps is given.  相似文献   

6.
In this paper, the concept of urban fringe is introduced and the problems in society, economy and ecology that the urban fringe is facing are analyzed. The policy, participant system and method of planning for development of urban fringe is discussed from three aspects as: idea, system and technique of planning. The compromised mode of development combining scattering and growing, the updating of the community organization and corresponding flexible means of planning is presented.  相似文献   

7.
High DC bus voltage stress is an important issue for the single stage PFC converters in practical application. This paper analyzes the inherent reason of the high bus voltage stress of single-stage power-factor-correction (PFC) AC/DC converters. Four possible resolving schemes are analyzed and discussed, and some of practical implementation circuits topologies are also given. Theoretical analysis and simulation results show that the both series-charging, parallel-discharging capacitors (SCPDC) scheme and bus-voltage-feedback (BVF) method are deemed to be more viable than the other two methods.  相似文献   

8.
In order to make good use of power line carrier to communicate, it is necessary to analyze the time-variable, impedance,attenuation and noise characteristics of low voltage power line. The waves of every characteristic have been experimented. At the same time, aiming at these characteristics, some available measures are given in order to conquer the disadvantage factors. The experimental results show that some suitable carrier communication modes must be adopted to realize ideally the carrier communication on low voltage power line.  相似文献   

9.
In this paper,we derive the necessary extension to the FD TD(finite difference time domain) method for absorbing coating of composite material.The scattering of electromagnetic waves(EW) from absorbing coating is considered,and the comparision of obtained results with exact analytic ones shows that the method used in this paper is correct and available.  相似文献   

10.
Dynamic responses of ultra high voltage transmission line ice shedding   总被引:1,自引:0,他引:1  
Numerical models of typical 500 kV ultra high voltage (UHV) transmission lines are set up in ABAQUS/CAE software. The dynamic response of the transmission lines with different structure parameters under various ice shedding load cases are analyzed, and th  相似文献   

11.
The polarization match between the antennae operated in the circular polarization mode can be maintained well without the use of complex tracking systems,many modern satellite and terrestrial point-to-point communications systems use circular polarization(CP) wave propagation in order to maximize the polarization component of the link budget.The effective design method of circular polarized crossed dipole feeds is presented analyzing the self-impedance of linear antennas and the useful design curves also is given here,the crossed dipoles is excited by a single hard coaxial-cable with a slot.The gain and circular polarized axial-ratio of the crossed dipoles is calculated with the electromagnetic simulation software HFSS,the results indicate that the design is reasonable and practical.  相似文献   

12.
Recent research progresses are summarized about the High Voltage Direct Current(HVDC) transmission system in control methods and modulation of HVDC transmission system,coordinated control of multi-infeed HVDC transmission system and AC-DC system.Some outsanding problems in current research are pointed out on such sides as system modeling,studying object,aim of coordinated control and engineering application.Based on the requirements of real systems and some latest research achievements on control technology and measure methods,some new research thoughts about HVDC transmission system for some problems of assessment and optimal combination of current control strategies,application of intelligent control methods and enhancement of coordinated control are proposed.  相似文献   

13.
There is no universal method of finding the analytic solutions to transmission lines discribed by partial differential equations,so many researchers are studying and developing transmission line theories.Computing steady-state solutions of uniform transmission lines is one part of the study.The paper introduces another method of computing sinsoidal steady-state solutions of lossy uniform transmission lines.First,the complex expressions of voltage and current with zero initial state are obtained from the complex frequency-domain model of lossy uniform tansmission lines.The network functions,which are the ratios of voltage and current's image functions to the excitation's image function,can be found from the complex expressions.Sinusoidal steady-state solutions can be obtained by using the relation between network function and system's frequency characteristic.Finally,the method is demonstrated to be effective by an example.  相似文献   

14.
The utilization of Flexible AC Transimssion System(FACTS)technology has significant impact on power system reliability performance.Series FACTS devices such as Thyristor Controlled Phase Shifting Transformers(TCPSTs) and Thyristor Controlled Series Compensators(TCSCs) can change the natural allocation of the power flow and effectively alleviate transmission congestion.Parallel FACTS devices such as Static Var Compensators(SVCs)can provide reactive power support and maintain voltage stability.So it is important to quantitatively evaluate their benefits to the power system reliability.The traditional models of the composite generation and transmission system reliability evaluation are mainly focused on conventional generation and transmission facilities.This paper researches the power flow model of TCPST and TCSC,and then presents the optimal load shedding model incorporating TCPSTs,TCSCs and SVCs and effectively incorporates them into the reliability evaluation model.The proposed method is tested on the RBTS and the obtained results show that the system reliability can be improved effectually by FACTS devices.  相似文献   

15.
Partial discharge electromagnetic waves in GIS propagate is not only in the transverse electric and magnetic(TEM)mode, but also in transverse electric(TE) and transverse magnetic(TM)mode. The paper deduces out the mathematic expressions transient field excited by PD in GIS anywhere by using dyadic Green function theory. The contributions of TEM mode and all high order modes in the detecting frequency scope should be taken into consideration when calculating the electric field excited by PD in GIS. In simulative GIS laboratory, the designed inner couplers are superior to other outer sensors in detection of partial discharge. Inner couplers for the GIS model are developed and their frequency responses are analyzed in antenna model. At last the PD pulses excited by man-made defect are detected by inner couplers using high parameters oscilloscope.  相似文献   

16.
The radiation field created by the transmission line stroked by lightning far from the lightning channel has been analyzed by the FDTD method.The authors we establish the calculation model and FDTD calculation method of transmission line,and discusses the import of lightning excitation source.The simulation of lightning stroked on a single transmission line in free space or stroked on three-phase high voltage transmission lines in actual environments has been done,and gives the distribution of transient radiation field around the transmission lines when lightning overvoltage wave transmits along the transmission line.The simulation result shows that: the effect of the transient radiation field caused by lightning over voltage wave done with environment is obvious,and the high frequency component of transient radiation field may disturb or do harm to the electronic facility or communication facility around the transmission lines.  相似文献   

17.
Based on the geometrical optics and vector diffraction theory, mode converter is studied the output mode of which is converted to line polarization Gauss beam of gyrotron and high power microwave device, the radiation characteristic of quasi-optical mode conversion is simulated. Quasi gauss mode HEll can be realized with Vlasov launcher and quasi-optical reflector.  相似文献   

18.
Using double-circuit transmission line is the developing tide for main 500 kV configuration to reduce line holding ground, so analyzing it's lightning protection performance is important to extend double-circuit transmission line in ultra high voltage network. The lightning protection performance of 500 kV double-circuit transmission line is studied with EMTP and EGM. The statistical method is applied to analyzing the lightning protection performance of back stroke by considering the randomness of working voltage's phase when lightning stroked the top tower. The result is that the line lightning protection level is different when the working voltage of conductor is different. It also improved the EGM by considering the effect of wind speed when analyzing the lightning protection performance of shielding failure. Furthermore, the results are given that wind speed has effects on the protection angle and the rate of shielding failure by using the program to calculate it.  相似文献   

19.
The topic of this thesis is ultraviolet communication system,one model of the Free Space Optics(FSO).The Free Space Optics communication system for civil use regards infrared light as transmission medium.However,for military use,if we want to establish a local communication system(about 1.5 km) with jamproof and safe,it is impossible to use infrared as transmission medium.Based on the predecessors' research and struggle,they discovered that ultraviolet light,especially the ultraviolet light in the solar blind light spectrum is a perfect transmission medium.Because of the absorption of air and scattering process in the atmosphere it can provide a suitable transmission distance and the ability to get over obstacles.The importance of the thesis is to introduce the key devices used in the communication system.  相似文献   

20.
Installing compensation equipments is a good manner to improve line transmission capacity and maintain power system stability in the extra high voltage(EHV) long distance transmission line.It is of benefit to analysis and control by describing the effect of compensation equipment correctly.At present,for predigesting analysis or increasing real-time calculating speed,concentrated parameter circuit model is widely used to analyze 500 kV EHV long distance transmission line which may cause bigger error.So it is necessary to get a more reasonable model.On the basic of voltage and current distributed equations of even distributed long distance line,this paper deduces phasor diagram and power-angle character equations of uncompensated long line.Then the authors analyze the effect of compensators and define two characteristic parameters,namely,equivalent impedance x_(eq) and voltage coefficient K_V.Any compensating states of EHV long distance transmission line,example installing the compensators in the line or not or which type of compensators,is described by the general phasor diagram and power-angle characteristic equations.Furthermore,increment calculation(equations) of two characteristic parameters is presented by the compensator parameters which may make the concepts clear and predigests analysis easily.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号