首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
A paired-ion liquid chromatographic (LC) technique coupled with fluorometric detection to determine riboflavin in various food matrices is described. Chromatograms of many foods showed 2 peaks of interest due to presence of riboflavin and flavin mononucleotide (FMN). Relatively high levels of FMN were found in raw beef, corned beef, chicken liver, and canned mushrooms. When riboflavin and FMN contents were summed, LC values were comparable to those obtained by the AOAC standard procedures. The LC technique was sensitive, rapid, and simple, yielding a mean standard deviation of 3.1% which was comparable to the AOAC fluorometric method (3.0%) and better than the AOAC microbiological assay (9.6%). Mean spike recoveries were 91.8% for LC compared to 90.5% and 89.6% for the AOAC fluorometric and microbiological methods, respectively.  相似文献   

2.
Two automated fluorometric methods were compared with the official AOAC methods for determining vitamin C in fortified ready-to-eat cereals, fruits, vegetables, baby foods, flour products, pet foods, meats, frozen dinners, juices, and nutritional health bars. Each sample was analyzed in duplicate on 2 days and included a recovery study on all products. Egberg's semiautomated method (Method 1) and Roy's automated method (Method 2) were compared with the manual AOAC tritrimetric and fluorometric methods. The correlation factor for Methods 1 and 2 were 0.999 and 0.979, respectively, when compared with the AOAC methods. The recovery study showed average recoveries of 97.8% for Method 1, 99.3% for Method 2, and 100.6% for the AOAC methods. The results suggest that Method 1 is the method of choice for the majority of the products analyzed.  相似文献   

3.
A simple, fast, inexpensive, and reliable method useful for the simultaneous, routine determination of thiamin and riboflavin in mushrooms is examined. It uses the extraction procedure, with slight modifications, proposed by the AOAC for the extraction of thiamin and riboflavin, followed by a liquid chromatographic separation on a reversed-phase Spherisorb ODS column with methanol/water as mobile phase gradient. Fluorometric detection is used at the following excitation and emission wavelengths, respectively, 360 and 425 nm in the case of thiamin and 422 and 515 nm for riboflavin. The analytical parameters of linearity, the precision of the method (RSD = 2.45 and 2.51% for thiamin and riboflavin, respectively), and the results of the comparison with the corresponding AOAC fluorometric methods show that the studied method is useful for the measurement of thiamin and riboflavin in fresh mushrooms.  相似文献   

4.
A semiautomated fluorometric method for the determination of resperpine in tablets was collaboratively studied by 7 laboratories. The method is a modification of the semiautomated method of Urbányi and Stober, which involves formation of a fluorogen with vanadium pentoxide. Collaborators were supplied with 3 composites, each from a different dosage level of commercial tablets. The results obtained agreed well with the AOAC manual fluorometric method; coefficients of variation ranged from 0.45 to 2.70%. The method has been adopted as official first action.  相似文献   

5.
A liquid chromatographic (LC) method has been developed for determination of thiamine in infant formula products. The method involves the following steps: (a) dissolution of the formula with water, (b) pH adjustment to induce protein precipitation, (c) filtration, (d) concentration of thiamine by using a cation exchange column and extraction system, (e) cleanup of adsorbed thiamine and other contaminants on the ion exchange column by washing with water and then methanol, (f) elution of thiamine with a mixture of methanol-2M potassium chloride buffer, (g) analysis for thiamine by liquid chromatography. Thiamine is separated from its phosphate esters, the mono-, di-, and triphosphates, as well as its antagonists oxythiamine and pyrithiamine on a 6 micron particle size column and a mobile phase of 40mM triethyl-ammonium phosphate buffer-methanol (pH 7.7) (90 + 10). The method is reproducible, with relative standard deviations ranging from +/- 0.76 to +/- 1.2%, depending on the infant formula product tested. Recovery of thiamine from various infant formula products is greater than 99%. Analysis for thiamine of several commercially available infant formulas at different levels of fortification gave results that ranged from 122 to 216% of the declared levels. These results agree well with those obtained using the AOAC fluorometric method.  相似文献   

6.
A simple and rapid method is presented for the liquid chromatographic assay of ascorbic acid, niacinamide, pyridoxine, thiamine, and riboflavin from a single chromatogram. Ion-pair chromatography with a reverse phase C18 cartridge in a radial compression system is used. Quantitation is excellent with a total analysis time of less than 20 min. A mobile phase of methanol-water (15 + 85) (0.005M heptanesulfonic acid) with 0.5% triethylamine at pH 3.6 and a flow rate of 2.0 mL/min gives the most satisfactory separation of the 5 water-soluble vitamins. By using 2 detectors in series set at different wavelengths and sensitivities, all 5 vitamins, with peak heights on scale, can be measured from a single injection; peak elution order is ascorbic acid, niacinamide, pyridoxine, thiamine, and riboflavin. Ascorbic acid is measured at 254 nm and the other vitamins, at 280 nm. The amount of amine modifier in the mobile phase is critical to the separation of niacinamide and pyridoxine. Recoveries of 5 water-soluble vitamins from spiked placebos were in the range of 98.2-102.0%. Confidence limits, +/- 3 SD, were in the range of 1.0-5.4%. Overall, the results obtained using the liquid chromatographic method show excellent agreement with manual methods and automated analysis.  相似文献   

7.
Six samples of canned tuna, albacore, yellowfin, and skipjack, in water or oil pack were analyzed in duplicate by a fluorometric method and the AOAC colorimetric method. For the fluorometric method, recoveries of histamine added to acceptable tuna averaged 99% with a range of 91 to 107%. Agreement between laboratories for the analyses of decomposed tuna containing 20-200 mg histamine/100 g sample was excellent. Results from the fluorometric method are comparable with those from the AOAC colorimetric method; the fluorometric method has been adopted as official first action.  相似文献   

8.
A previously published fluorometric method for vitamin A in milk, involving saponification in centrifuge tubes and extraction with hexane, was automated using conventional automated equipment including a filter fluorometer. The extraction and separation steps were affected by the presence of fat, so standards were prepared in milk. The peaks obtained with samples were 95% of steady state values. The coefficients of variation for 10 replicate analyses were 1.9% for unfortified milk and 1.3% for fortified milk. In tests on 19 different milk samples, the results of the automated and manual fluorometric methods differed by less than 10%; a colorimetric method using SbCl3 gave more erratic results and was more lengthy and laborious.  相似文献   

9.
Ten laboratories analyzed 9 pairs of blind duplicate raw milk samples for total solids. A direct forced air oven method (4 h at 100 degrees C) and a modification of the AOAC predry method (16.032) were used. Preliminary evaluation of the modified AOAC method indicated that blank determinations were necessary. Total solids content ranged from 12.0 to 14.6%. Average repeatability standard deviations (Sr) of the direct forced air oven and modified AOAC methods were 0.019 and 0.017, respectively. Average reproducibility standard deviations (SR) of the direct forced air oven and the modified AOAC methods were 0.042 and 0.047, respectively. Average repeatability relative standard deviations (RSDr) for the direct forced air oven and the modified AOAC methods were 0.149 and 0.136%, respectively; average reproducibility relative standard deviations (RSDR) were 0.327 and 0.370%, respectively. Mean repeatability values (r) and reproducibility values (R) were 0.054 and 0.118 for the direct forced air oven method and 0.049 and 0.133 for the modified AOAC method, respectively. The mean test result of the direct forced air oven method (12.7293%) was comparable to that for the modified AOAC method (12.7273%). The modification of AOAC method 16.032 and the direct forced air oven method have been approved interim official first action.  相似文献   

10.
Two extraction and liquid chromatographic procedures are presented which separate amprolium from compounds in poultry feed or premixes that could interfere with its fluorometric determination. The procedures are based on earlier work on the determination of thiamine in food samples. Amprolium is extracted from feed with a hexane-aqueous sulfosalicylic acid mix, separated on a C18 column, and detected fluorometrically after postcolumn derivatization. For premixes, water extraction is used. Values for the amprolium content of poultry feed obtained with these procedures are in good agreement with those obtained with AOAC official methods. It is suggested that these methods with suitable modifications may be of use for routine analysis of amprolium in feeds. The overall methods are rapid and appear to give reasonable results.  相似文献   

11.
A new procedure is described for the determination of polybrominated biphenyls (PBBs) in dry animal feeds and developmental results are discussed. Finely ground feed is packed into a chromatographic column containing Celite and then eluted with methylene chloride. The concentrated extract is cleaned up by elution with petroleum ether through Florisil before gas-liquid chromatographic quantitation. Chromatograms thus obtained were essentially free of the interfering peaks encountered when using AOAC methods for pesticide residues in dry products. Results of feed analyses by the proposed procedure averaged 30% higher than those obtained by AOAC procedures. Recoveries of PBBs from samples fortified at levels of 0.04 to 0.4 ppm ranged from 90 to 104%, with an average of 98%.  相似文献   

12.
A very fast and simple method for determination of nonphosphorylated thiamine in infant formula products, milk, and other nonfortified foods using reverse-phase ion-pairing liquid chromatography (LC) has been developed. Sample preparation consists of merely acid treatment to precipitate protein, followed by gravity filtration. No concentration, extraction, derivatization, or preliminary column cleanup is necessary. The chromatography is done on muBondapack C18 with an aqueous mobile phase containing 0.15% sodium hexane sulfonate, 20% MeOH, 1.5% HOAc, and 0.1% EDTA at a flow rate of 2.5 mL/min. Ultraviolet detection at 248 nm is used. A typical run takes 7 min, and 60 samples can be processed in 4 h. Results average from 96 to 104% of theory for the infant formula products analyzed. A 99 to 103% recovery of spike has been demonstrated. Method precision is good (2 to 4% RSD, short-term, and 2 to 5% RSD, long-term, depending on sample type). Peak separation from thiamine phosphate esters is achieved. Specificity is demonstrated by UV spectral scan and absorbance ratios. Equivalency to a microbial method (validated against the official AOAC fluorometric method) was established. The method is used for high-volume quality control testing of milk-based infant formula products in the ready-to-use, concentrate, or powder form.  相似文献   

13.
Several authors have studied histamine using gas chromatography (GC) as a tool for quantitation, but the methods used were not always suitable depending on the kind of food. Problems frequently cited include incomplete histamine elution from the columns and peak tailing. Histamine is of interest because it is the factor common to all cases of scombroid poisoning, it has physiological and biological activity, and it is a chemical indicator of fish quality. In this study a modified GC method was used to quantify histamine in mahi-mahi (Coryphaena hippurus). Mean recovery was 67% for the GC method, compared with 90% for the AOAC fluorometric method. There was a 0.96 correlation of the GC histamine values with those of the AOAC fluorometric method. A temperature program, splitless/split injection, and analyte cleanup were essential for GC properties. Histamine retention time was 8.2 min. The method allowed peak height to be used for quantitation and simultaneous analysis of cadaverine and putrescine.  相似文献   

14.
This collaborative study was undertaken to determine if the anticoagulants acenocoumarol, phenprocoumon, and potassium warfarin could be analyzed by the automated analysis system described in the collaborative study for the analysis of sodium warfarin and dicumarol. Collaborators were supplied with a composited tablet sample of each anticoagulant. Results agreed well with the National Formulary methods for phenprocoumon and potassium warfarin, and an unpublished method for acenocoumarol. For acenocoumarol, coefficients of variation on individual sets of data ranged from 0.30 to 1.94% For phenprocoumon, coefficients of variation ranged from 0.52 to 1.20%. For potassium warfarin, coefficients of variation ranged from 0.54 to 1.79%. The results of this study show that acenocoumarol, phenprocoumon, and potassium warfarin can be analyzed by the official AOAC method for the analysis of sodium warfarin and dicumarol tablets.  相似文献   

15.
A manual vacuum manifold and an automated solid phase extraction (ASPEC) system were applied for purification of ochratoxin A and zearalenone in wheat, rye, barley, and oat samples with immunoaffinity columns followed by separation with a high-performance liquid chromatograph and fluorescence detection. The immunoaffinity columns for manual sample purification were purchased from a different manufacturer than were those for the automated system. The limit of detection (LOD) for the method for ochratoxin A with a vacuum manifold and ASPEC was 0.1 microg/kg. For the method for zearalenone, the LODs were 1.5 microg/kg with a vacuum manifold and 3 microg/kg with ASPEC. For the methods for ochratoxin A at spiking levels of 0.6 and 2.5 microg/kg, mean recoveries for different cereals varied from 68 to 106%. For the methods for zearalenone, mean recoveries varied from 78 to 117% at spiking levels of 9 and 25 microg/kg. The relative standard deviations of repeatability with various cereals employing both methods were 2-15 and 2-19% for ochratoxin A and zearalenone, respectively.  相似文献   

16.
A rapid, simple, and reliable liquid chromatographic method has been developed for the simultaneous determination of nicotinamide (niacinamide), thiamine, riboflavin, riboflavin sodium phosphate, pyridoxine, caffeine, and sodium benzoate in commercial oral liquid tonics. The 7 components are separated on a reverse phase C18 column using a mobile phase of acetonitrile-0.01M potassium dihydrogen phosphate-triethylamine (8 + 91.5 + 0.5 v/v/v) containing 5mM sodium octanesulfonate and adjusted to pH 2.8 with phosphoric acid. Components are detected at 254 nm with attenuation 0.02 AUFS. Acetanilide is used as an internal standard. In addition to the 7 components mentioned, nicotinic acid (niacin), cyanocobalamin, and folic acid are also separated under the same conditions. Sample preparation involves only addition to internal standard solution and dilution with mobile phase and then filtration. Recoveries of the 7 components and cyanocobalamin from spiked preparations ranged from 97 to 104% with coefficients of variation of 0.9-4.2%.  相似文献   

17.
A liquid chromatographic method for the assay of oxytetracycline in premixes and veterinary products is described. Premix samples are extracted with acidified methanol, diluted with mobile phase, and filtered before chromatography on a C-8, reverse phase column. The assay method separates oxytetracycline from epioxytetracycline, tetracycline, and chlortetracycline. Total elution time for oxytetracycline is less than 5 min at 1.5 mL/min. Five spiked premix samples each of 2 and 50 g/lb had a coefficient of variation of 3.5 and 4.5% and a mean recovery of 99 and 104%, respectively. The results of premixes and veterinary products assayed by this method compared closely with those of the same assayed by the official AOAC microbiological method.  相似文献   

18.
The LECO FP-228 "Nitrogen Determinator" was compared with the AOAC copper catalyst Kjeldahl method, 7.033-7.037, for the determination of crude protein in feed materials. The completely microprocessor-controlled instrument determines nitrogen by measuring the nitrogen gas following combustion of the sample; it was easy to operate and broadly applicable. A wide variety of feed materials of various nitrogen levels were analyzed in one mixed sequence. Results were precise, accurate, and rapid. Analysis time for one sample was approximately 3 min. Fourteen samples containing 2.5-15.5% N were selected for study and consisted of meals, grains, forages, and standard organic materials. The overall mean for the 14 samples by the LECO combustion method was 8.61% N compared with an overall mean of 8.58% N for the AOAC Kjeldahl method. Within-sample standard deviations for the LECO combustion method ranged from 0.013 to 0.052% N with a pooled standard deviation (SD) of 0.033% N for the 14 samples. Standard deviations for the AOAC Kjeldahl method ranged from 0.006 to 0.035% N with a pooled SD of 0.022% N. Combined average recovery of nitrogen from tryptophan, lysine-HCl, and EDTA determined by the LECO combustion method was 99.94% compared to 99.88% determined by the AOAC Kjeldahl method.  相似文献   

19.
A collaborative study was conducted to compare automated methods for rapid determination of fat and moisture in meat and poultry products with the official AOAC solvent extraction and forced-air oven methods, respectively. Fourteen products were tested, with fat and moisture contents ranging from 2 to 43% and 44 to 74%, respectively. Eight of the collaborating laboratories analyzed the products by using a moisture/fat analyzer; 4 laboratories used the AOAC methods. Standard deviations for within-laboratory repeatability, between-laboratory reproducibility, and bias for each product indicated that the rapid methods were acceptable. The moisture/fat analyzer methods have been adopted official first action for fat and moisture analyses in meat and poultry products.  相似文献   

20.
Seven laboratories participated in a collaborative study of a method for determination of phosphorus in meat and meat products. Samples are digested in sulfuric acid and hydrogen peroxide; digestion is complete in approximately 10 min. Phosphorus is determined by colorimetric analysis of a dilute aliquot of the sample digest. The collaborators analyzed 3 sets of blind duplicate samples from each of 6 classes of meat (U.S. Department of Agriculture classifications): smoked ham, water-added ham, canned ham, pork sausage, cooked sausage, and hamburger. The calibration curve was linear over the range of standard solutions prepared (phosphorus levels from 0.05 to 1.00%); levels in the collaborative study samples ranged from 0.10 to 0.30%. Standard deviations for repeatability (sr) and reproducibility (SR) ranged from 0.004 to 0.012 and 0.007 to 0.014, respectively. Corresponding relative standard deviations (RSDr and RSDR, respectively) ranged from 1.70 to 7.28% and 3.50 to 9.87%. Six laboratories analyzed samples by both the proposed method and AOAC method 24.016 (14th Ed.). One laboratory reported results by the proposed method only. Statistical evaluations indicated no significant difference between the 2 methods. The method has been adopted official first action by AOAC.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号