首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 28 毫秒
1.
Seven FDA pesticide laboratories collaborated to develop and validate an LC-MS/MS method to determine 173 pesticides in <20 min. The average determination coefficient (r2) was >0.99 for all but two compounds tested. The limits of detection were <20 ng/mL for all compounds and <10 ng/mL for 363 of the 368 transitions reported. The method was used to determine pesticides in two AOAC sponsored proficiency samples. The LC-MS/MS determination was used for the analysis of oranges, carrots and spinach using the QuEChERS (Quick, Easy, Cheap, Effective, Rugged, Safe) method. Each matrix was fortified at 20, 100, 400, and 1000 ng/g. No false positive responses were detected in controls of the three matrices. 165 pesticides had recoveries between 70 and 130%, and 161 had minimum detection levels less than 10 ng/g. Recoveries of 169 compounds for the 1000 ng/g spikes were within 50-150%. A matrix effect study indicated all three matrices caused a small net suppressing effect, the most pronounced attributable to the citrus matrix. The procedure proved to be accurate, precise, linear, sensitive and rugged, and adds 100 pesticides to the scope of the FDA pesticide program.  相似文献   

2.
This paper describes a new method for the rapid extraction and unequivocal confirmation of 13 sulfonamides (SAs) in raw meat and infant foods. The highly automated extraction procedure is based on accelerated solvent extraction followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) as a confirmatory analysis. After 1 g of food matrix was blended with 2 g of C18 as a solid support material, the mixture was packed into the extraction cell and the SAs were extracted with 10 mL of hot water at 160 degrees C and 100 atm; 100 microL of the extract was directly injected into the LC-MS system. The analytes were ionized in an electrospray interface operating in the positive ion mode and were identified by selecting two multireaction monitoring transitions, which guaranteed method specificity. Typical recoveries from crude meat and baby food samples ranged from 70 to 101% at a fortification level of 100 ppb, corresponding to the maximum residue limits established by the European Union and the U.S. Food and Drug Administration. The interday method precision was less than 8.5%, and the limits of detection were below 2.6 ppb. This study has taken matrix-induced suppression of ionization into account, by comparing standard and matrix-matched calibration curves. Four of the 13 monitored SAs have been detected in some baby foods and raw meat samples, bought from Roman supermarkets and butchers' shops, using the described methodology.  相似文献   

3.
A method was developed for the determination and confirmation of furazolidone, nitrofurazone, furaltadone, and nitrofurantoin as their side-chain residues in honey using liquid chromatography-tandem mass spectrometry (LC-MS/MS). An initial solid-phase extraction cleanup of the honey samples was followed by overnight hydrolysis and derivatization of the nitrofuran side-chain residues with 2-nitrobenzaldehyde. After pH adjustment and liquid-liquid extraction, the extracts were assayed by LC-MS/MS using electrospray ionization in the positive ion mode. The method was validated at concentrations ranging from 0.5 to 2.0 ppb with accuracies of 92-103% and coefficients of variation of < or =10%. The lowest calibration standard used (0.25 ppb) was defined as the limit of quantitation for all four nitrofuran side-chain residues. The extracts and standards were also used for confirmatory purposes. Honey from dosed beehives was assayed to study the stability of the nitrofuran residues and to demonstrate the effectiveness of the method.  相似文献   

4.
An analytical method for the simultaneous determination of residues of eight neonicotinoid insecticides and two metabolites in honey using LC-MS/MS was developed and validated. Two approaches of sample preparation were investigated, with the final method involving acetonitrile extraction and subsequent cleanup by dispersive solid-phase extraction (QuEChERS type). Validation was based on quintuplicate analysis at three fortification levels and showed satisfactory recoveries (60-114%) and high precision (RSDs between 2.7 and 12.8%). Low limits of detection and quantification could be achieved for all analytes ranging from 0.6 to 5 μg/kg and from 2 to 10 μg/kg, respectively. Investigations of Austrian honey samples revealed the presence of acetamiprid, thiacloprid, and thiamethoxam residues in honey; however, no sample exceeded the maximum residue limits. On average, flower honey samples contained neonicotinoid residues in higher quantities compared to forest honey samples.  相似文献   

5.
A comparison of ultrahigh performance liquid chromatography (UHPLC) with a 2.6 μm core-shell particle column (Kinetex C(18)) and conventional liquid chromatography (LC) with a 3 μm porous particle column (Atlantis dC(18)), coupled with electrospray ionization tandem mass spectrometry (ESI-MS/MS), for the determination of 151 pesticides in grains is presented in this study. Pesticides were extracted from grain samples using a procedure known as QuEChERS (quick, easy, cheap, effective, rugged, and safe). Quantification, with an analytical range from 5 to 500 μg/kg, was achieved using matrix-matched standard calibration curves with isotopically labeled standards or a chemical analogue as internal standards. The method performance parameters that included overall recovery, intermediate precision, and measurement uncertainty were evaluated using a designed experiment, that is, the nested design. The UHPLC (Kinetex C(18)) was superior to conventional LC (Atlantis dC(18)) as it yielded a shorter analytical run time, increased method sensitivity, and improved method performance. For UHPLC/ESI-MS/MS (Kinetex C(18)), 90% of the pesticides studied had recoveries between 81 and 110%, 88% of the pesticides had intermediate precision ≤20%, and 84% of the pesticides showed measurement uncertainty ≤40%. As compared to UHPLC/ESI-MS/MS (Kinetex dC(18)), the LC/ESI-MS/MS (Atlantis dC(18)) showed a relatively lower sensitivity, less repeatability, and larger measurement uncertainty. UHPLC/ESI-MS/MS with 2.6 μm core-shell particle column and scheduled MRM proved to be a good choice for quantification or determination of pesticides in grains.  相似文献   

6.
A method making use of turbulent flow chromatography automated online extraction with tandem mass spectrometry (MS/MS) was developed for the analysis of 4 quinolones and 12 fluoroquinolones in honey. The manual sample preparation was limited to a simple dilution of the honey test portion in water followed by a filtration. The extract was online purified on a large particle size extraction column where the sample matrix was washed away while the analytes were retained. Subsequently, the analytes were eluted from the extraction column onto an analytical column by means of an organic solvent prior to chromatographic separation and MS detection. Validation was performed at three fortification levels (i.e., 5, 20, and 50 microg/kg) in three different honeys (acacia, multiflower, and forest) using the single-point calibration procedure by means of either a 10 or 25 microg/kg calibrant. Good recovery (85-127%, median 101%) as well as within-day (2-18%, median 6%) and between-day (2-42%, median 9%) precision values was obtained whatever the level of fortification and the analyte surveyed. Due to the complexity of the honey matrix and the large variation of the MS/MS transition reaction signals, which were honey-dependent, the limit of quantification for all compounds was arbitrarily set at the lowest fortification level considered during the validation, e.g., 5 microg/kg. This method has been successfully applied in a minisurvey of 34 honeys, showing ciprofloxacin and norfloxacin as the main (fluoro)quinolone antibiotics administered to treat bacterial diseases of bees. Turbulent flow chromatography coupled to LC-MS/MS showed a strong potential as an alternative method compared to those making use of offline sample preparation, in terms of both increasing the analysis throughput and obtaining higher reproducibility linked to automation to ensure the absence of contaminants in honey samples.  相似文献   

7.
A method based on a gel permeation chromatography (GPC) extraction procedure combined with an additional cleanup by solid-phase extraction (SPE) on silica gel and liquid chromatography-mass spectrometry (LC-MS) detection has been validated for the analysis of seven glycidyl esters (GEs) including glycidyl laurate, myristate, palmitate, stearate, oleate, linoleate, and linolenate in various edible oils. This method was conjointly developed and validated by two different laboratories, using two different detection systems, a LC time of flight MS (LC-ToF-MS) and a LC triple-quadrupole MS (LC-MS/MS). The extraction procedure allowed targeting low contamination levels due to a highly efficient matrix removal from the 400 mg oil sample loaded on the GPC column and is suitable for routine analysis as 24 samples can be extracted in an automated and reproducible way every 12 h. GPC extraction combined with SPE cleanup and LC-MS/MS detection leads to a limit of quantification in oil samples between 50 and 100 μg/kg depending on the type of glycidyl ester. Recoveries ranged from 68 to 111% (average = 93%). Quantification was performed by automated standard addition on extracts to compensate matrix effects artifacts. To control recoveries of each sample four isotopically labeled GEs ((13)C(3) or (13)C(4)) were included in the method.  相似文献   

8.
Rugged LC-MS/MS survey analysis for acrylamide in foods   总被引:8,自引:0,他引:8  
The described liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the detection of acrylamide in food entails aqueous room temperature extraction, SPE cleanup, and analysis by LC-MS/MS. The method is applicable to a wide variety of foods. [(13)C(3)]acrylamide is the internal standard. The limit of quantitation is 10 ppb (microg/kg). Data were obtained in duplicate from >450 products representing >35 different food types. The variability in analyte levels in certain food types suggests that it may be possible to reduce acrylamide levels in those foods.  相似文献   

9.
An effective method using liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed and optimized to obtain a complete separation of five representative plant growth regulators (PGRs) [gibberellic acid, 2,4-dichlorophenoxyacetic acid (2,4-D), thidiazuron, forchlorfenuron, and paclobutrazol] in fruits. Extraction was performed with acetonitrile containing 0.1% (v/v) acetic acid, applying modified quick, easy, cheap, effective, rugged, and safe (QuEChERS) methodology. LC-MS/MS conditions including composition of mobile phases and mass spectrometry (MS) conditions were evaluated to achieve the highest sensitivity in MS detection. All of the data acquisition was employed in the segmented multiple-reaction monitoring mode for the selected negative and positive transition ions. The octadecylsilyl (C18) dispersive solid-phase extraction (SPE) sorbent was found to provide the more satisfied recoveries than primary secondary amine (PSA) and graphitized carbon black (GCB) for five target PGRs. The optimized method allowed for recoveries of 76-112% for the five PGRs from fruit samples with relative standard deviation (RSD) values less than 10%. Limits of quantification (0.5-16.5 μg/kg) were lower than the maximum limit of residues established for PGRs. The results demonstrated that the developed LC-MS/MS and QuEChERS extraction method is highly effective for analyzing trace amounts of target PGRs in fruit samples. Finally, the method was successfully used to detect residual PGRs in Beijing, China, in 2010. The concentrations of 2,4-D (5.1-1503 μg/kg) and paclobutrazol (1-1381 μg/kg) found in orange and peach, respectively, suggesting that the use of these PGRs in these fruits should be regulated in China in the future.  相似文献   

10.
A liquid chromatography electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) method was developed and validated to quantify and confirm trace levels of 13 pesticides including aldicarb sulfoxide, aldicarb sulfone, oxamyl, methomyl, formetanate, 3-hydroxycarbofuran, carbendazim, thiabendazole, aldicarb, propoxur, carbofuran, carbaryl, and methiocarb in apple-based infant foods such as apple sauces, apples and strawberries, apples and blueberries, and apples and plums. Data acquisition under MS/MS was achieved by applying multiple reaction monitoring of two fragment ion transitions to provide a high degree of sensitivity and selectivity for both quantification and confirmation. LC/ESI-MS/MS quantitative results were significantly affected by matrices, and thus, the standard addition was employed to compensate for the matrix effects to achieve the best accuracy of the method. Recoveries of 13 pesticides, spiked at 5.0, 25.0, and 45.0 microg/kg, were around 100% using the LC/ESI-MS/MS standard addition. The method detection limits (S/N > or = 3:1) of 13 pesticides were less than 0.2 microg/kg.  相似文献   

11.
The fates of more than 300 pesticide residues were investigated in the course of beer brewing. Ground malt artificially contaminated with pesticides was brewed via steps such as mashing, boiling, and fermentation. Analytical samples were taken from wort, spent grain, and beer produced at certain key points in the brewing process. The samples were extracted and purified with the QuEChERS (Quick Easy Cheap Effective Rugged and Safe) method and were then analyzed by LC-MS/MS using a multiresidue method. In the results, a majority of pesticides showed a reduction in the unhopped wort and were adsorbed onto the spent grain after mashing. In addition, some pesticides diminished during the boiling and fermentation. This suggests that the reduction was caused mainly by adsorption, pyrolysis, and hydrolysis. After the entire process of brewing, the risks of contaminating beer with pesticides were reduced remarkably, and only a few pesticides remained without being removed or resolved.  相似文献   

12.
A detailed analytical study on trichlorfon residues in selected vegetables samples has been carried out, focused on the reliable quantification and confirmation of this compound, and on stability of residues under storage. As a consequence, a rapid and sensitive LC-ESI-MS/MS method has been developed for the determination of residues of this insecticide in kaki fruit (flesh and peel) and cauliflower samples. Extraction was performed with acetonitrile using a high-speed blender. After 4-fold dilution of the extract with water, 20 microL was directly injected in the LC-ESI-MS/MS system (triple quadrupole), using matrix-matched standards calibration for quantification. Under optimized MS/MS conditions, limit of detections between 0.006 and 0.013 mg/kg were reached, and a limit of quantification of 0.05 mg/kg was established, with a runtime of only 15 min. Recoveries from spiked blank samples at 0.05 and 0.5 mg/kg were in the range 83-101% with relative standard deviations lower than 10%. The method was applied to treated and untreated samples collected from field residues trials, using quality control samples analysis for the evaluation of the method. Despite the acquisition of two MS/MS transitions in selected reaction monitoring mode, the analysis of treated samples revealed the presence of a chromatographic peak close to the analyte that corresponded to a trichlorfon isobaric compound that shared the same MS/MS transitions. This unusual situation in LC-MS/MS-based procedures required the application of an efficient chromatographic separation to avoid this interference. All experiments have been made in compliance with the principles of Good Laboratory Practices (GLP) and following the European SANCO guidelines for pesticides residue analysis (PRA).  相似文献   

13.
An analytical method for the simultaneous determination of 51 pesticides in commercial honeys was developed. Honey (10 g) was dissolved in water/methanol (70:30; 10 mL) and transferred to a C(18) column (1 g) preconditioned with acetonitrile and water. Pesticides were subsequently eluted with a hexane/ethyl acetate mixture (50:50) and determined by gas chromatography with electron impact mass spectrometric detection in the selected ion monitoring mode (GC-MS-SIM). Spiked blank samples were used as standards to counteract the matrix effect observed in the chromatographic determination. Pesticides were confirmed by their retention times, their qualifier and target ions, and their qualifier/target abundance ratios. Recovery studies were performed at 0.1, 0.05, and 0.025 microg/g fortification levels for each pesticide, and the recoveries obtained were >86% with relative standard deviations of <10%. Good resolution of the pesticide mixture was achieved in approximately 41 min. The detection limits of the method ranged from 0.1 to 6.1 microg/kg for the different pesticides studied. The developed method is linear over the range assayed, 25-200 microg/L, with determination coefficients of >0.996. The proposed method was applied to the analysis of pesticides in honey samples, and low levels of a few pesticides (dichlofluanid, ethalfluralin, and triallate) were detected in some samples.  相似文献   

14.
An analytical method was developed for the determination of bound residues of the nitrofuran drugs furazolidone, nitrofurazone, furaltadone, and nitrofurantoin with a sensitivity of 1 ppb in shrimp. In this procedure, shrimp tissue is prewashed with solvents followed by overnight acid hydrolysis, during which the side chains of the bound residues are released and simultaneously derivatized with 2-nitrobenzaldehyde. After liquid-liquid extraction cleanup, the derivatives are detected and quantitated using liquid chromatography-mass spectrometry/mass spectrometry (LC-MS/MS) with an atmospheric pressure chemical ionization interface. The method was validated using control shrimp fortified with each side-chain analyte at 1, 2, and 4 ppb. Method accuracies were >80% with coefficients of variation of <20% for all four analytes. Tissues from dosed shrimp were assayed to demonstrate the effectiveness of the method for recovering bound residues of nitrofurans. In shrimp dosed with nitrofurans, nitrofurantoin exhibited the lowest level of bound residues.  相似文献   

15.
A high-throughput liquid chromatography tandem mass spectrometry (HT LC-MS/MS) method for red blood cell (RBC) folate analysis was developed from a previously described manual (M) LC-MS/MS method. The HT LC-MS/MS method used 96-well plates in which RBC folates were hydrolyzed with concentrated HCl in the presence of the [13C6]pABA internal standard (IS). The pH of the hydrolysate was adjusted to 5.0 before cleanup using 96-well plate OASIS HLB SPE cartridges. The analyte and IS were eluted with ethyl acetate/hexane (95:5, v/v) and methylated with methanol and trimethylsilyldiazomethane. The methylated analyte and IS were quantified with LC-MS/MS as previously described. The HT LC-MS/MS method was validated by determining the recovery of six different folate vitamers, which were quantitatively recovered (84-105% with CV<9.0%). RBC folate concentrations in whole blood samples correlated between HT and M LC-MS/MS methods (r=0.922, p<0.0001 for n=43 samples) and between the HT LC-MS/MS method and a chemiluminescence assay (r=0.664, p<0.001 for n=325 samples). Comparison of the results between HT LC-MS/MS and chemiluminescence methods with Bland-Altman difference plots and by ROC curve analysis indicates that the chemiluminescence assay underreports RBC folate concentrations. The HT LC-MS/MS method allows for high-throughput sample preparation for the analysis of RBC folate.  相似文献   

16.
In a study on the behaviour of pesticides in a soil–plant–water system, the quick, easy, cheap, effective, rugged and safe (QuEChERS) method for analysing pesticide or metabolite residues in soil and maize (leaves, roots and kernels) was optimized and validated. The pesticides bentazone, chloridazon and terbuthylazine and their metabolites bentazone-methyl, chloridazon-desphenyl, chloridazon-methyl-desphenyl, terbuthylazine-desethyl and terbuthylazine-2-hydroxy were selected in this study. The QuEChERS extracts obtained from soil and maize matrices and the collected leachate were analysed by liquid chromatography–electrospray ionization–tandem mass spectrometry (LC–ESI–MS/MS) using a high-performance liquid chromatography and an ultra-high-performance liquid chromatography (UHPLC) analytical column. As expected, shorter run times and higher sensitivity were achieved with the UHPLC column. Validation studies focused on recovery, repeatability, matrix effects, limits of detection and quantification. Recoveries (and repeatability relative standard deviation (RSD)) of the spiked samples were in the range of 55 to 98 % (7.4–18) in soil, 23 to 101 % (1.7–20) in maize and 82 to 105 % (4.4–25) in leachate. Quantification limits were lower than 3.0 μg kg?1 in soil, 7.3 μg kg?1 in maize and 0.080 μg l?1 in leachate.  相似文献   

17.
A rapid multiresidue method was developed for the determination of nine organophosphorus pesticides in fruit juices. The analytical procedure is based on the matrix solid-phase dispersion (MSPD) of juice samples on Florisil in small glass columns and subsequent extraction with ethyl acetate assisted by sonication. Residue levels were determined by gas chromatography with nitrogen-phosphorus detection. Spiked blank samples were used as standards to counteract the matrix effect observed in the chromatographic determination. The NPD response for all pesticides was linear in the concentration range studied with determination coefficients >0.999. Average recoveries obtained for all of the pesticides in the different juices and fortification levels were >70% with relative standard deviations of <11%. The detection limits ranged from 0.1 to 0.6 microg/kg. The identity of the pesticides was confirmed by gas chromatography with mass spectrometric detection using selected ion monitoring. The proposed MSPD method was applied to determine pesticide residue levels in fruit juices sold in Spanish supermarkets. At least one pesticide was found in most of the samples, although the levels detected were very low, far from the maximum residue levels established for raw fruit.  相似文献   

18.
A method was developed to determine organophosphorus pesticides (OPs) in dried ground ginseng root. Pesticides were extracted from the sample using acetonitrile/water saturated with salts, followed by solid-phase dispersive cleanup, and analyzed by capillary gas chromatography with electron ionization mass spectrometry in selective ion monitoring mode (GC-MS/SIM) and flame photometric detection (GC-FPD) in phosphorus mode. The detection limits for most of the pesticides were 0.025-0.05 microg/g using GC-FPD but were analyte-dependent for GC-MS/SIM, ranging from 0.005 to 0.50 microg/g. Quantitation was determined from 0.050 to 5.0 microg/g with r 2 > 0.99 for a majority of the pesticides using both detectors. Recovery studies were performed by fortifying the dried ground ginseng root samples to concentrations of 0.025, 0.1, and 1.0 microg/g, resulting in recoveries of >90% for most pesticides by GC-FPD. Lower (<70%) and higher (>120%) recoveries were most likely from complications of pesticide lability or volatility, matrix interference, or inefficient desorption from the solid-phase sorbents. There was difficulty in analyzing the ginseng samples for the OPs using GC-MS at the lower fortification levels for some of the OPs due to lack of confirmation. GC-FPD and GC-MS/SIM complement each other in detecting the OPs in dried ground ginseng root samples. This procedure was shown to be effective and was applied to the analysis of OPs in ginseng root samples. One particular sample, a ground and dried American ginseng (Panax quinquefolius) root sample, was found to contain diazinon quantified at approximately 25 microg/kg by external calibration using matrix-matched standards or standard addition using both detectors. The advantage of using both detectors is that confirmation can be achieved using GC-MS, whereas the use of a megabore column in GC-FPD can be used to quantitate some of the nonpolar OPs without the use of matrix-matched standards or standard addition.  相似文献   

19.
A rapid, specific, and sensitive method based on the Quick Easy Cheap Effective Rugged and Safe (QuEChERS) method and a cleanup using dispersive solid-phase extraction with MgSO(4), PSA, and C18 sorbents has been developed for the routine analysis of 14 pesticides in strawberries. The analyses were performed by three different analytical methodologies: gas chromatography (GC) with electron capture detection (ECD), mass spectrometry (MS), and tandem mass spectrometry (MS/MS). The recoveries for all the pesticides studied were from 46 to 128%, with relative standard deviation of <15% in the concentration range of 0.005-0.250 mg/kg. The limit of detection (LOD) for all compounds met maximum residue limits (MRL) accepted in Portugal for organochlorine pesticides (OCP). A survey study of strawberries produced in Portugal in the years 2009-2010 obtained from organic farming (OF) and integrated pest management (IPM) was developed. Lindane and β-endosulfan were detected above the MRL in OF and IPM. Other OCP (aldrin, o,p'-DDT and their metabolites, and methoxychlor) were found below the MRL. The OCP residues detected decreased from 2009 to 2010. The QuEChERS method was successfully applied to the analysis of strawberry samples.  相似文献   

20.

Purpose

Analyzing organic pollutants in forest soil is challenging because they are strongly physical and chemical bound to soil organic matter (SOM). Within the framework of a forest soil inventory, an analytical protocol for the determination of polycyclic aromatic hydrocarbons (PAH), polychlorinated biphenyls (PCB), and organochlorine pesticides (OCP) should be established and validated using one and the same extraction and cleanup procedure. The protocol should be applicable for reliable analysis of a high number of samples in a short timeframe.

Materials and methods

Two different soil samples representative for the humic layer from a typical mixed and coniferous forest soil had been used for the analysis. Three solvents of different polarity, namely cyclohexane (CH), ethylacetate (EA)/CH (1/1, v/v), and acetone (AC)/CH (2/1, v/v), and the six standard extraction techniques (pressurized liquid extraction (PLE), soxhlet extraction, fluidized bed extraction, sonication, shaking, and one-step extraction recommended for analyzing agricultural soil in Germany (VDLUFA 2008)) were compared concerning their extraction efficiency. For additional matrix separation, two different cleanup procedures (gel permeation chromatography (GPC) and solid-phase extraction (SPE) with different sorbents) were tested. Quantification was carried out using gas chromatography combined with mass spectrometry (GC–MS) and two different injection systems (split/splitless injection and programmable temperature vaporizer (PTV) injection). Labeled internal standards, added prior to extraction, were used for method evaluation.

Results and discussion

For the simultaneous extraction of PAH, PCB, and OCP from organic forest soil PLE with acetone/cyclohexane (2/1, v/v) provided the highest extraction efficiency. A two-step cleanup procedure consisting of GPC followed by SPE with silica gel was entirely sufficient for the separation of humic substances without discrimination of analytes. Recovery rates for the different extraction and cleanup steps ranged between 89% and 106%. For quantification, a GC–MS method was developed using two different injection systems and two capillary columns of different selectivity.

Conclusions

By comparing six standard extraction techniques for PAH, PCB, and OCP from forest soil, we obtained the highest extraction efficiency when using PLE with AC/CH (2/1). For sample injection, we achieved best results using an optimized PTV injection system as it highly reduced the breakdown of thermolabile pesticides. Using this combination of technical equipment, it is possible to determine a concentration of the analytes in the trace level range of 1–2 μg kg?1 in humic soil.  相似文献   