首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
The objective of this work was to compare the accuracy of radiographs and magnetic resonance imaging (MRI) for estimating appendicular osteosarcoma margins. The accuracy of computed tomography (CT) and bone scintigraphy was also assessed when these studies were available. Eight dogs with appendicular osteosarcoma underwent radiographic and MRI of affected limbs. In addition, bone scintigraphy was performed in six dogs and CT examination was performed in five dogs. Two observers jointly measured tumor length on all imaging studies. Correlative gross and histologic evaluation of all affected limbs was performed to determine tumor extent as measured from the nearest articular surface. Results from imaging studies were compared to gross and microscopic morphometry findings to determine the accuracy of each modality for determining tumor boundaries. MRI images were accurate with a mean overestimation of actual tumor length of 3 +/- 13%. T1-weighted non-contrast images were superior in identifying intramedullary tumor margins in most instances whereas contrast-enhanced images provided supplemental information in two dogs. Lateromedial and craniocaudal radiographs overestimated tumor length by 17 +/- 28% and 4 +/- 26%, respectively. Scintigraphy and CT overestimated tumor margins by 14 +/- 28% and 27 +/- 36%, respectively. MRI appears to be an accurate diagnostic imaging modality in determining intramedullary osteosarcoma boundaries. MRI should be considered as part of a pre-operative assessment of appendicular osteosarcoma, particularly when a limb-sparing procedure is contemplated.  相似文献   

2.
OBJECTIVE: To determine which imaging modality best determines the microscopic extent of primary appendicular osteosarcoma in amputated limbs in dogs. DESIGN: Case series. ANIMALS: 10 dogs with appendicular osteosarcoma. PROCEDURE: 10 dogs with appendicular osteosarcoma that did not receive neoadjuvent chemotherapy were treated by use of limb amputation. Amputated limbs were imaged by use of radiography, computed tomography (CT), and magnetic resonance imaging (MRI) and examined microscopically to determine longitudinal extent of neoplastic cell involvement and length of associated intramedullary fibrosis. Changes detected by use of the various imaging studies were compared with the actual tumor length determined microscopically. Data were analyzed to determine which imaging technique most closely predicted tumor length. RESULTS: Measurements obtained by use of craniocaudal radiographic views were most accurate at predicting tumor length but underestimated tumor length substantially in 1 limb and slightly in another limb. Measurements made by use of CT were most accurate at predicting tumor length when intramedullary fibrosis was taken into account but underestimated tumor length in 1 limb. Measurements made by use of MRI were least accurate but did not underestimate tumor length in any of the limbs. CONCLUSIONS AND CLINICAL RELEVANCE: Although radiography is used in diagnosis of osteosarcoma in dogs, additional imaging studies to confirm the extent of neoplasia prior to limb-sparing ostectomy may be beneficial. Underestimation of tumor length would be associated with higher incidence of incomplete excision and local tumor recurrence.  相似文献   

3.
The objective of this article was to compare radiography, planar bone scintigraphy, and single-photon emission computed tomography (SPECT) to determine the size of osteosarcomas in long bones of dogs. Ten dogs with osteosarcoma in six radii, two humeri, one tibia, and one ulna were evaluated. Macroslides, mediolateral radiographs, planar scintigrams, and sagittal images from SPECT scans were used to obtain measurements. On the scintigraphic images, the edges of the tumor were established using the activity profile imaging tool. The radiographic magnification was factored. The mean percentage of tumor size overestimation was 9.29% on mediolateral radiographs, 5.35% on planar scintigrams, and 33.25% on SPECT images. The correlation coefficient adjusted for sample size was significantly higher (P<0.01) for technetium 99m ((99m)Tc) hydroxyethylene diphosphonate (HDP) (75.5%) and radiography (61.3%) compared with indium 111-vitamin B(12) (28.3%). The correlation coefficient for (99m)Tc-HDP was higher than that obtained for radiographs; however, statistical difference between the two variables was not demonstrated (P>0.05). (99m)Tc bone scan is a good estimator of intramedullary size of osteosarcoma in long bones when the activity profile tool to determine the margin of the tumor is used.  相似文献   

4.
OBJECTIVE--To compare the accuracy of radiography, nuclear scintigraphy, and histopathology for determining the proximal extent of distal radius osteosarcoma in dogs. STUDY DESIGN--Retrospective clinical study. SAMPLE POPULATION--Twenty client-owned dogs taken to Colorado State University with osteosarcoma of the distal radius. METHODS--Medical records of 20 dogs with confirmed osteosarcoma that underwent a limb-salvage procedure were reviewed. Measurements were performed directly from the lateral view of each radius, from both the scintigram and the radiograph, to determine the length of the radius and the distance from the proximal extent of the tumor to the distal radiographic or scintographic extent of the radius. The ratio of distal radial involvement to total radius length was calculated. A similar ratio was also determined using the macroslide, which included the entire portion of bone that was excised during the limb-salvage procedure. All 3 methods of measurement were compared. RESULTS--Nuclear scintigraphy significantly overestimated tumor length when compared with macroslide specimen measurements. Radiography also overestimated tumor length, but these results were not significantly different from macroslide specimen measurements. CONCLUSIONS--Both radiography and nuclear scintigraphy overestimate the extent of distal radius osteosarcoma in dogs when compared with histopathologic macroslides of the same lesions. Nuclear scintigraphy overestimated tumor extent to a larger degree than did radiography. CLINICAL RELEVANCE--Although radiography is a more accurate method of measurement of the extent of distal radius osteosarcoma, because nuclear scintigraphy overestimates tumor length to a greater degree, scintigraphy may provide a larger margin of safety for determining the site of proximal osteotomy during a limb-salvage procedure. However, caution should be taken when utilizing scintigraphy, because this method may overestimate length of radius involved to such an extent as to cause the surgeon to believe that a patient is not a suitable limb-salvage candidate.  相似文献   

5.
Specimens of 20 canine primary bone tumors (18 osteosarcoma, 2 fibrosarcoma) were examined to compare the maximal axial length of gross tumor with the length of the lesion seen on preoperative radiographs and 99mTc methylene diphosphonate bone scintigraphic images. Radiographs defined the length of the tumor to within +/- 10% of the gross measurement for 6 (30%), underestimated it for 12 (60%), and overestimated it for 2 (10%) specimens. Bone scintigraphy defined tumor length within +/- 10% for 8 (40%), underestimated it for 1 (5%), and overestimated it for the remaining 11 (55%) specimens. Use of radiographic evaluation alone could result in underestimation of the diaphyseal extent of a primary bone tumor, with risk of incomplete resection. Bone scan images tend to overestimate tumor length and, therefore, may provide safer resection guidelines.  相似文献   

6.
We compared serum concentrations of zinc, chromium, and iron in dogs with cancer to those of normal dogs. Dogs with lymphoma (n = 50) and osteosarcoma (n = 52) were evaluated. Dogs with lymphoma had significantly lower (P = .0028) mean serum zinc concentrations (mean +/- SD; 1.0 +/- 0.3 mg/L) when compared to normal dogs (1.2 +/- 0.4 mg/L). Dogs with osteosarcoma also had lower mean serum zinc concentrations (1.1 +/- 0.4 mg/L), but this difference was not significant (P = .075). Serum chromium concentrations were significantly lower in dogs with lymphoma (2.6 +/- 2.6 microg/L, P = .0007) and osteosarcoma (2.4 +/- 3.1 microg/L, P = .0001) compared to normal dogs (4.7 +/- 2.8 microg/L). Serum iron concentrations and total iron-binding capacity were significantly lower in dogs with lymphoma (110.8 +/- 56.7 microg/dL, P < .0001, and 236.6 +/- 45.6 microg/dL, P < .0001, respectively) and osteosarcoma (99.6 +/- 49.3 microg/dL, P < .0001, and 245.0 +/- 43.8 microg/dL, P = .0011, respectively) when compared to normal dogs (175.1 +/- 56.7 microg/dL and 277.1 +/- 47.4 microg/dL). Mean ferritin concentration was significantly higher in dogs with lymphoma (1291.7 +/- 63.0 microg/L) than in normal dogs (805.8 +/- 291.1 microg/L, P < .0001) and dogs with osteosarcoma (826.5 +/- 309.2 microg/L, P < .0001). Further investigation is needed to explore the clinical significance of these mineral abnormalities in dogs with cancer.  相似文献   

7.
Objective— To evaluate agreement and repeatability of vertebral column measurements using computed tomography (CT) and magnetic resonance imaging (MRI).
Study Design— Retrospective observational study.
Animals— Dogs (n=18) with disc associated wobbler syndrome; Dog cadavers (n=3).
Methods— Five measurements of the 5th cervical vertebra were performed: vertebral body length (VBL), vertebral canal height (VCH), vertebral body height (VBH), vertebral canal width (VCW), and vertebral body width (VBW). Measurements were performed independently twice by 2 observers. Bland-Altman plots were created to evaluate agreement. Cadaveric vertebrae with soft tissue removed had the same variables and actual dimensions measured.
Results— The largest discrepancy between CT and MRI measurement was for VBL (mean difference±SD=1.262 mm±1.245; P <.001), with the difference for all the other variables being acceptable. The 1st measurement was significantly higher than the 2nd only for VBL using CT (mean difference=0.476 mm±1.120; P =.009), with all other variables having acceptable differences. Mean difference for all measurements between 2 observers was small, except for VBL using CT (mean difference=0.762 mm±1.042; P <.001). Only the difference for VBL between CT and cadaver specimens was statistically significant.
Conclusions— Our results suggest high repeatability and good agreement for most vertebral measurements of interest. VBL measurement using CT was considered problematic.
Clinical Relevance— Provided limitations are understood, linear measurements of vertebral dimensions from CT and MRI images can be used clinically.  相似文献   

8.
Radiographic, myelographic and computed tomographic (CT) studies from sixteen dogs with histologically diagnosed vertebral or spinal cord neoplasia (seventeen lesions) were retrospectively evaluated. Radiographs were compared with CT images to evaluate vertebral bony changes (bone production, lysis or both). Myelographic and CT images were evaluated to separate lesions into one of three categories, extradural, intradural/extramedullary, or intramedullary. These findings were compared to histologic tumor type from surgical or necropsy samples. Histologically, seven lesions were vertebral tumors and were classified as extradural lesions; ten lesions were spinal cord tumors of which eight were classified as intradural/extramedullary and two as intramedullary. Using CT, the amount of bony change associated with extradural lesions was greater than or equal to the amount of bony change visualized using radiographs. Myelography more correctly differentiated between intradural/ extramedullary and intramedullary lesions than did CT, although three open diagnoses detracted from the CT results. This study suggests that when evaluating extradural lesions, the amount of bony change was better visualized using CT than survey radiographs. Myelography was better when compared to CT for classifying spinal cord lesions, however, standardization of the CT imaging protocol may help determine the specific clinical indications for using CT in dogs with suspected vertebral or spinal cord tumors.  相似文献   

9.
OBJECTIVE: To determine the reproducibility and accuracy of computed tomographic (CT) measurements of pituitary gland dimensions in healthy dogs. ANIMALS: 35 healthy sexually intact adult dogs. PROCEDURES: 2 observers independently viewed CT images of the skull in 35 dogs twice. Pituitary gland height, width, length, and volume and pituitary gland height-to-brain area ratio (P:B ratio) were measured or calculated. Intraobserver and interobserver agreement indexes (AIs) were calculated for pituitary gland dimensions. Computed tomography was performed also on 5 phantoms, and both observers measured phantom dimensions twice. True-value AIs were calculated for the phantom study. RESULTS: The mean +/- SD interobserver AI between observer 1 and 2 for pituitary gland height and the P:B ratio was 0.90 +/- 0.07. The intraobserver AI for pituitary gland height and the P:B ratio was 0.97 +/- 0.04 for observer 1 and 0.94 +/- 0.04 for observer 2. The intra and interobserver AIs for the other dimensions were lower than those for pituitary gland height and the P:B ratio. All phantom dimensions on CT images were underestimated significantly, compared with their true values. CONCLUSIONS AND CLINICAL RELEVANCE: The intra- and interobserver AIs for pituitary gland dimension measurements on CT images were high. However, the same observer preferably should perform serial measurements. Window settings influence pituitary gland dimension measurements, and predetermined window settings are recommended to make comparisons among dogs. Pituitary gland dimension measurements made from CT images in our study underestimated the true values.  相似文献   

10.
Abstract

AIMS: To objectively compare measures of bone healing, using computed tomography (CT) in dogs following bilateral tibial tuberosity advancement (TTA), between tibiae treated with and without autogenous cancellous bone grafts.

METHODS: Ten dogs with bilateral cranial cruciate ligament disease requiring surgical stabilisation were prospectively recruited to undergo single-session bilateral TTA, with only one, randomly assigned, tibia receiving bone graft in the osteotomy deficit. Bone healing at the osteotomy site was assessed using CT performed 38–70 days post-operatively. CT images were evaluated using both objective measurements of osseous bridging and subjective evaluation by six radiologists. Repeated measures ANOVA was used to compare the objective outcomes between the grafted and non-grafted tibiae.

RESULTS: The mean percentage of the osteotomy deficit bridged at the lateral cortex was greater in grafted (77.6, SD 35.2%) compared to non-grafted (63.0, SD 36.5%) tibiae (p=0.001), but did not differ at the medial cortex (p=0.1). The mean minimum callus width was greater in grafted (7.2, SD 3.3 mm) compared to non-grafted (3.6, SD 2.9 mm) tibiae (p<0.001). There was no difference in mean attenuation (measured in Hounsfield units) of the callus between grafted and non-grafted tibiae (p=0.5). The grafted tibia was deemed to have superior bone healing in 50/60 subjective assessments made by radiologists.

CONCLUSIONS: Superior osseous bridging was detected by CT analysis following TTA using autogenous cancellous bone grafts compared with no graft. This was shown by greater bridging percentage at the lateral cortex and formation of a broader callus. Qualitative assessments made by six radiologists also supported the conclusion that bone healing was improved by use of autogenous cancellous bone graft. CT was a useful method for assessing evidence of bone healing following TTA.

CLINICAL RELEVANCE: These findings justify the application of autogenous cancellous bone graft to augment healing following TTA in dogs.  相似文献   

11.
A non-invasive imaging modality, computed tomography (CT), was used to visualize changes in nasal turbinates of anesthetized pigs over a 12-week observation period (pigs were 14 wk of age at study week 0). Normal, non-infected pigs were compared to pigs with mild challenge-induced atrophic rhinitis (AR) in order to detect subtle differences in morphology. To determine feasibility for time course studies in future experiments, morphometric quantitation at the level of the 2nd premolar (turbinate area ratio or TAR) in cross-section CT images at multiple timepoints was done. Additionally, at study termination, the TAR determined from CT images, magnetic resonance imaging (MRI), and wet tissue (WT), were compared to each other and to the standard subjective measure, visual scoring. There were no statistically significant differences between the control and AR groups at CT imaging dates of 0, 3, 6, 9, or 12 wk (P = 0.182). However, a statistically significant decrease in TAR measurements over time (P = 0.015) was observed in both groups, with lower mean values observed on Weeks 3 and 6 before rebounding to baseline values at study termination. At Week 12 (termination of the study), the TAR measurements derived from CT, MRI, and WT were not statistically different from one another (P = 0.220) and the treatment group-by-method interaction was not significant (P = 0.800). This provided evidence of equivalency of the techniques. Mean values for normal and infected groups were not significantly different based on either TAR imaging methods (P = 0.552) or visual scores (P = 0.088). Thus, the current study demonstrated that CT was an acceptable alternative imaging modality which could be used for quantitation of turbinate changes in snouts of live pigs to provide data comparable to tissue taken at necropsy. Computed tomographic imaging would allow non-invasive tracking of disease or treatment responses within individual animals over time. Morphometric analysis of the TAR was equivalent between the CT, MRI, and WT specimens.  相似文献   

12.
The effectiveness of various fixation techniques in preventing rotation of fracture segments in transverse fractures of the canine femoral diaphysis was evaluated under laboratory conditions. Single intramedullary Steinmann pins, single Küntscher nails, multiple intramedullary Steinmann pins, and an intramedullary Steinmann pin with a 1/2 Kirschner splint fixation sustained mean torque moments of 0.31, 0.61, 1.26, and 1.63 Newton meters, respectively, before rotation of the fracture segments occurred. Four-pin (full Kirschner) splints were more effective, sustaining a mean torque moment of 5.35 Newton meters before rotation occurred. The canine femoral medullary canal had an average isthmus length of 2.0 to 2.5 cm. The restricted area of implant-cortex contact limited the effectiveness of the intramedullary fixation devices in preventing fracture segment rotation.  相似文献   

13.
Narrowing of the equine cervicothoracic intervertebral foramina (IF) has the potential to cause forelimb lameness and/or neck pain although limited information is available on CT of the IF. The aims of this retrospective, analytical study were to describe a protocol for quantifying CT cervicothoracic IF size; evaluate the repeatability of IF size measures; test associations between IF size and adjacent articular process (AP) size, ventral extent, and anatomic location; and determine the proportion of IF with narrowing. Computed tomographic images were acquired in 20 Warmblood horses that presented with forelimb lameness and/or neck pain. All IF between C5 and T2 (n = 160) were evaluated. IF cross-sectional area (CSA), APCSA, and AP ventral extent were measured. The repeatability of IFCSA measurement was calculated. Possible associations between IFCSA and: APCSA, ventral extent, side, or location were assessed. IF narrowing was defined as more than 50% of reduction in IF height when compared with its widest part(s). The repeatability of IFCSA measurement was excellent. There was a significant association between IFCSA and: APCSA (P < 0.001; R2 = 0.859; slope = −0.106), ventral extent (P = 0.022; R2 = 0.161; slope = −0.0617), and location (P < 0.001; higher values between C7 and T2). The association between IFCSA and ventral extent was small. Narrowing was identified in 61 (38.1%) IF. Maximum degree of narrowing was most common at the cranial (26.3%) and middle (68.8%) third of the IF. Narrowing was not identified at T1-T2. In conclusion, CT cervicothoracic IF size can be measured with excellent repeatability, and associations were found between IF size and: AP size, ventral extent, and location.  相似文献   

14.
BACKGROUND: The magnetic resonance imaging (MRI) features of ischemic myelopathy have been described in the human literature and in a small number of cases in the veterinary literature. HYPOTHESIS: The aims of this study were to identify associations among MRI findings, timing of imaging, and presenting neurologic deficits in a large series of dogs with a presumptive diagnosis of ischemic myelopathy. ANIMALS AND METHODS: The medical records and MR images of dogs with a presumptive diagnosis of ischemic myelopathy (2000-2006) were reviewed retrospectively. Inclusion criteria were acute onset of nonprogressive and nonpainful myelopathy, 1.5-tesla MRI of the spine performed within 7 days of onset, and complete medical records and follow-up information. Presumptive diagnosis was based on history, as well as clinical, MRI, and cerebrospinal fluid (CSF) findings. The extent of the lesion on MRI was assessed as the following: (1) the ratio between the length of the hyperintense area on sagittal T2-weighted images and the length of C6 or L2 vertebral body, and (2) the maximal cross-sectional area of the hyperintense area on transverse T2-weighted images as a percentage of cross-sectional area of the spinal cord. RESULTS: Fifty-two dogs met the inclusion criteria. MRI findings were abnormal in 41 dogs and normal in 11 dogs. The presence of MRI abnormalities was not significantly associated with the timing of imaging (P = .3) but was associated with ambulatory status on presentation (P = .04). Severity of signs on presentation was associated with extent of the lesion on MRI (P = .02). CONCLUSION AND CLINICAL IMPORTANCE: The severity of signs on presentation is associated with the presence and the extent of the lesion on MRI.  相似文献   

15.
Computed tomography (CT) scans can be acquired with the transverse images aligned either parallel to the endplates or perpendicular to the vertebral canal. The purpose of this prospective cross‐sectional study was to determine the effect of angle acquisition on CT morphometric evaluation of the cervical vertebral column of Great Danes with and without cervical spondylomyelopathy. Twenty‐eight Great Danes (13 normal, 15 affected) were sampled. For each dog, a set of CT images was acquired with the transverse slices aligned parallel to the endplates and another one with the transverse images aligned perpendicular to the vertebral canal. For each different set, transverse slices from the cranial, middle, and caudal aspects of the individual vertebral bodies C2‐C7 were measured. Height, width, transverse area, right dorsal to left ventral height (RDLV), and left dorsal to right ventral height (LDRV) were recorded by a single observer at each location. For both affected and control dogs, significant differences between the measurements obtained from the two sets of transverse images were found only at the cranial aspect of the vertebrae (P = 0.005, P < 0.001, P < 0.001, P = 0.005, and P = 0.010 for height, width, area, RDLV, and LDRV, respectively). Measurements for the middle and caudal aspects did not differ. The funnel‐shape morphology of the cervical vertebral foramina in Great Danes with stenosis of their cranial aspect may be responsible for the significant differences found. Considering that the morphometric parameters were significantly affected by CT slice angle in the current study, authors recommend that a standardized scanning protocol be followed when morphometric evaluations using CT are planned.  相似文献   

16.
The aims of this study were to determine the size of the medial retropharyngeal lymph nodes in apparently healthy dogs using ultrasonography and to investigate relationships between body weight (1.8-59 kg), age (1.0-15 years), and medial retropharyngeal lymph node sizes (width, height, and length). The sample population consisted of 100 apparently healthy, volunteered, adult dogs. The data were normally distributed, thus mean, SD, and Pearson's correlation were used. Repeatability of ultrasound measures was assessed as the percentage of differences between duplicate measures that were within 2 SDs of the differences: all measures were at least 93% repeatable (differences typically were < or = 0.25 cm and always < 1 cm). No difference between sexes was observed. The medial retropharyngeal lymph node increased in size with increased body weight (r = 0.46 to 0.59) and decreased in size with increased age (r = -0.30 to -0.50). Although statistically significant, the actual variation is not likely clinically important due to the small range of sizes, measurement error, and various combinations of age and body weight. Therefore, regardless of body weight or age, the average width is 1.0 cm, height is 0.5 cm, and length is 2.5 cm and maximum width is 2 cm, height is 1 cm, and length is 5 cm. Based on the maximal difference between duplicate measures (with some exception), any change > or = 0.4 cm with width or height, or > or = 1.0 cm in length, in a follow up measurement probably represents a true biological change rather than measurement error.  相似文献   

17.
OBJECTIVE: To describe anatomy of the orbits as revealed by computed tomography (CT) in different scan planes, determine the most useful scan plane for imaging the eye, optic nerve, and extraocular muscles, and compare image quality of direct CT images with reconstructed images obtained from 2-mm-thick and 5-mm-thick transverse images. ANIMALS: 9 dogs with no ocular abnormalities. PROCEDURE: In 3 dogs, CT was combined with cisternography to facilitate imaging of the optic nerve and determine the scan plane that allowed optimum imaging of the optic nerve in a single image. In 6 dogs, CT images were made in transverse, dorsal oblique, and sagittal oblique scan directions. Dorsal and sagittal reconstructions were made from transverse images. RESULTS: In all dogs, scanning in different planes enabled identification of ocular structures, optic nerves, and orbital adnexa, as well as identification of the confines of the orbit. Imaging of optic nerve and extraocular muscles was optimal on dorsal oblique scans at an angle of 43 to 45 degrees to the skull base and on sagittal oblique images at an angle of 59 to 61 degrees to the midline of the skull. CONCLUSIONS AND CLINICAL RELEVANCE: All scan directions provided detailed images of orbital structures. Transverse images were convenient for survey examination, and dorsal oblique and sagittal oblique images were superior for imaging optic nerves and extraocular muscles. Image quality of reconstructed images obtained from the 2-mm-thick transverse images was superior to that obtained from the 5-mm-thick images. Optimum quality was achieved with direct multiplanar imaging.  相似文献   

18.
Twenty two dogs with an infiltrative lipoma had computed tomographic (CT) images acquired to evaluate the extent of local disease. Ten dogs had undergone at least one cytoreductive surgical procedure (range = 1-3; median = 2) prior to imaging. Twenty dogs had measurable disease on CT images; 2 dogs had diffuse disease at a previous surgical site that could not be measured. Tumor volume (n = 20) ranged from 20 to 5,632 cm3 (median = 345 cm3; mean = 996 cm3). None of the dogs had evidence of bone involvement on the CT images; 2 of the 22 dogs had tumors that did not come into direct contact with osseous structures. All dogs with measurable disease had evidence of a fat opacity mass with variable degrees of muscle infiltration. Eleven of 22 dogs were given intravenous contrast medium prior to image acquisition and there was not evidence of enhancement of the infiltrative lipoma in any dog. Based on CT images, tumors were classified as well-defined in 9 dogs, moderately well-defined in 4, not well-defined in 3 and a mix of well-defined and not well-defined in 6 dogs. Tumors tended to be less well-defined in regions where the infiltrative lipoma interdigitated with normal body fat. It appears CT imaging allows adequate discrimination of tumor with the caveat that differentiation of normal fat from infiltrative lipoma can be problematic.  相似文献   

19.
The aim of this study was to describe the scintigraphic appearance and location of the sacroiliac joint (SI-joint) in dorsal and dorso 30 degree lateral views of the equine pelvis in a scintigram. The pelvis from 10 different horses was prepared by attaching plastic tubes along relevant margins of the bone and around the SI-joint. A radioactive solution was injected into the tubes, and scintigraphic images were acquired with a gamma camera. Five specific landmarks were identified on the left and right sides of the pelvis. There was no significant difference in the distance measurements between the left and right sides in the dorsal view. The SI-joint was roughly ovoid in shape, with its long axis angled to the midline. The most craniolateral point of the SI-joint (Y) was located at the middle (SD = 0.04) of a line drawn from the caudal margin of the tuber sacrale (TS) to the craniolateral margin of the tuber coxa (TC), which was called TS-TC. In 85% of the specimens, the long axis of the SI-joint (SILA) was located caudal to or intersecting TS-TC, and the mean angle between SILA and TS-TC was 16.4 degrees (SD = 5.6 degrees). The distance from the caudomedial point of the SI-joint (Z) to Y was 0.38 times (SD = 0.04) the length of TS-TC. The distance from the tuber sacrale to the medial border of the SI-joint (TS-X) was 0.15 times (SD = 0.02) the length of TS-TC. In the oblique view, the SI-joint appeared wider and was positioned more laterally compared to the dorsal view. The distance TS-Y increased to 0.61 times (SD = 0.046) TS-TC, but SILA/TS-TC was essentially unchanged. The mean angle between TS-TC and SILA increased to 20.9 degrees (SD = 5.6 degrees). TS-X increased to 0.31 times (SD = 0.037) TS-TC. The location of the SI-joint was very similar in all horses, which makes it possible to estimate the location of the SI-joint in a scintigram in which the tuber sacrale and the craniolateral margin of the tuber coxa are identified.  相似文献   

20.
Objectives : To assess if the volumes of the caudal cranial fossa (CCF), parenchyma within the caudal cranial fossa (CCFP) or ventricles (V) are associated with syringomyelia (SM) in cavalier King Charles spaniels (CKCS) with Chiari-like malformation (CM). To evaluate if volumes are associated with transverse syrinx width. Methods : Magnetic resonance images of 59 CKCS with CM were retrospectively reviewed and grouped with or without SM. Three-dimensional images were created and volumes of the fossae, brain parenchyma and ventricular system were calculated from which percentages of CCF, CCFP and V were created. If present, syrinx size was measured from its maximal transverse width. The percentages were statistically compared between groups, and correlation between percentages and syrinx dimensions was made. Results : CKCS with SM had significantly higher CCFP (P=0·0001) and V (P=0·0002) to those without but no significant difference in CCF (P=0·925). There was a positive correlation between CCFP and syrinx width (Pearson r=0·437) and ventricle size to syrinx width (Spearman r=0·627). Clinical Significance : A more marked overcrowding of the CCF is associated with SM, which may explain the high incidence of SM in CKCS with CM. The association between ventricle and syrinx dimensions supports the theory that SM development is the result of altered cerebrospinal fluid dynamics.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号