A rapid confirmatory method for monitoring chloramphenicol (CAP) residues in honey, whole milk, and eggs is presented. This method is based on the polymer monolith microextraction (PMME) technique and high-performance liquid chromatography (HPLC)-electrospray ionization mass spectrometry (MS). A poly(methacrylic acid-ethylene glycol dimethacrylate) monolithic capillary column was selected as the extraction medium. To obtain optimum extraction efficiency, several parameters related to PMME were investigated. After dissolution in 20 mM phosphate solution at pH 4.0 and centrifugation, honey, eggs, or milk samples were directly passed through the extraction tube. The LC-MS instrument was equipped with an electrospray ion source and a single quadrupole. The eluates were analyzed by LC-MS in the negative-ion mode and by monitoring a pair of isotopic ions for the target compound. The in-source collision-induced dissociation process produced confirmatory ions. The recoveries of CAP from real samples spiked at 0.1-10 ng/g (honey), 0.2-10 ng/mL (milk), and 0.2-10 ng/g (egg) were in the range of 85-102%, with relative standard deviations ranging between 2.1% and 8.9%. The limits of detection (S/N = 3) were 0.02 ng/g, 0.04 ng/mL, and 0.04 ng/g in honey, milk, and eggs, respectively. The proposed method was proved to be robust in monitoring CAP residue in honey, milk, and eggs.  相似文献   

2.
A method was developed for detection of a variety of polar drug residues in eggs via liquid chromatography/tandem mass spectrometry (LC/MS/MS) with electrospray ionization (ESI). A total of twenty-nine target analytes from four drug classes-sulfonamides, tetracyclines, fluoroquinolones, and beta-lactams-were extracted from eggs using a hydrophilic-lipophilic balance polymer solid-phase extraction (SPE) cartridge. The extraction technique was developed for use at a target concentration of 100 ng/mL (ppb), and it was applied to eggs containing incurred residues from dosed laying hens. The ESI source was tuned using a single, generic set of tuning parameters, and analytes were separated with a phenyl-bonded silica cartridge column using an LC gradient. In a related study, residues of beta-lactam drugs were not found by LC/MS/MS in eggs from hens dosed orally with beta-lactam drugs. LC/MS/MS performance was evaluated on two generations of ion trap mass spectrometers, and key operational parameters were identified for each instrument. The ion trap acquisition methods could be set up for screening (a single product ion) or confirmation (multiple product ions). The lower limit of detection for screening purposes was 10-50 ppb (sulfonamides), 10-20 ppb (fluoroquinolones), and 10-50 ppb (tetracyclines), depending on the drug, instrument, and acquisition method. Development of this method demonstrates the feasibility of generic SPE, LC, and MS conditions for multiclass LC/MS residue screening.  相似文献   

3.
A confirmatory assay able to unambiguously identify and quantify 10 approved-for-use beta-lactam antibiotics in milk below stipulated U.S. and EU tolerance levels is presented. beta-Lactams are extracted from 10 mL of intact milk by a Carbograph 4 cartridge. After solvent removal, residue reconstitution, and filtration, a completely transparent and uncolored extract is injected into a liquid chromatography -mass spectrometry (LC-MS) instrument equipped with an electrospray (ES) ion source and a single quadrupole. During the chromatographic run, the ES/MS system is operated first in the positive-ion mode (PI) and then in the negative-ion (NI) mode. This is done to circumvent matrix interferences resulting in remarkable signal weakening of the last-eluted analytes, when detecting them as [M+H]+ adduct ions. MS data acquisition is performed by a time-scheduled three-ion selected ion monitoring program. At the 5 ng/mL level, recoveries of the beta-lactams are between 70 (nafcillin) and 108% (cephalin), with relative standard deviations ranging between 5 (oxacillin) and 11% (amoxicillin and ceftiofur). The response of the ES/MS detector is linearly related to injected amounts up to 500 ng, irrespective of the chemical characteristics of the beta-lactams and the acquisition mode selected (PI or NI modes). Limits of quantification, based on a minimal value of the signal-to-noise ratio of 10, were estimated to be within 0.4 (cephalin) and 3 ng/mL (dicloxacillin). Analyses of milk samples taken after intramammary application of amoxicillin showed that 1.2 ng/mL of this penicillin was still present 6 days after treatment. At this concentration level, the identification power of the method is not weakened, as signals of the three product ions of amoxicillin are still well distinguishable from the background noise.  相似文献   

4.
A simple and specific method able to identify and quantify traces of 14 sulfonamide antibacterials (SAs) in milk and eggs is presented. This method uses a single solid-phase extraction (SPE) cartridge for simultaneous extraction and purification of SAs in the above matrices. Milk and egg samples are passed through a Carbograph 4 sorption cartridge. After analyte desorption, an aliquot of the final extract is injected into a liquid chromatography-mass spectrometry (LC-MS) instrument equipped with an electrospray ion source (ESI) and a single quadrupole. MS data acquisition is performed in the positive-ion mode and by a time-scheduled multiple-ion selected ion monitoring program. Compared to two published methods, the present protocol extracted larger amounts of SAs from both milk and egg and decreased the analysis time by a factor of 3 with milk samples and by a factor of 2 with egg samples. Recovery of SAs in milk at the 5 ppb level ranged between 76 and 112% with relative standard deviations (RSDs) of 相似文献   

5.
A simple specific and rapid confirmatory method for determining the two amphoteric penicillins, that is, amoxicillin and ampicillin, in bovine muscle, liver, kidney, and milk is presented. This method is based on the matrix solid-phase dispersion technique with hot water as extractant followed by liquid chromatography (LC)-tandem mass spectrometry. With this instrumentation, the selected reaction monitoring acquisition mode with two fragmentation reactions for each analyte was adopted. After acidification and filtration of the aqueous extracts, 25 microL of the tissue final extracts and 50 microL of the milk final extract were injected into the LC apparatus. Absolute recovery of the two analytes in any biological matrix at the 50 ppb level in tissues and the 4 ppb level in milk was 74-95% with relative standard deviations (RSDs) of no larger than 9%. When penicillin V was used as surrogate internal standard, relative recovery of the targeted compounds present in bovine tissues and milk at, respectively, 25 and 2 ppb levels ranged between 100 and 106% with RSDs of no larger than 11%. When fractionation of analytes by using a short chromatographic run was attempted, remarkable signal weakening for the two analytes was experienced. This effect was traced to polar endogenous coextractives eluted in the first part of the chromatographic run that interfered with the gas-phase ion formation of the two penicillins. Slowing the chromatographic run eliminated this unwelcome effect. Limits of quantification of the two analytes in bovine milk were estimated to be <1 ppb, whereas amoxicillin and ampicillin could be quantified in bovine tissues down to 3.1 and 0.8 ppb levels, respectively.  相似文献   

6.
This paper describes a new method for the rapid extraction and unequivocal confirmation of 13 sulfonamides (SAs) in raw meat and infant foods. The highly automated extraction procedure is based on accelerated solvent extraction followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) as a confirmatory analysis. After 1 g of food matrix was blended with 2 g of C18 as a solid support material, the mixture was packed into the extraction cell and the SAs were extracted with 10 mL of hot water at 160 degrees C and 100 atm; 100 microL of the extract was directly injected into the LC-MS system. The analytes were ionized in an electrospray interface operating in the positive ion mode and were identified by selecting two multireaction monitoring transitions, which guaranteed method specificity. Typical recoveries from crude meat and baby food samples ranged from 70 to 101% at a fortification level of 100 ppb, corresponding to the maximum residue limits established by the European Union and the U.S. Food and Drug Administration. The interday method precision was less than 8.5%, and the limits of detection were below 2.6 ppb. This study has taken matrix-induced suppression of ionization into account, by comparing standard and matrix-matched calibration curves. Four of the 13 monitored SAs have been detected in some baby foods and raw meat samples, bought from Roman supermarkets and butchers' shops, using the described methodology.  相似文献   

7.
A simple, specific, and rapid analytical method for determining seven largely used carbamate insecticides in tomato, spinach, lettuce, zucchini, pear, and apple is here presented. This method is based on the matrix solid-phase dispersion technique, with heated water as extractant followed by liquid chromatography (LC)-mass spectrometry (MS) equipped with a single quadrupole and an electrospray ion source. Target compounds were extracted from the vegetal matrixes by water heated at 50 degrees C. After acidification and filtration, 0.25 mL of any aqueous extract was injected in the LC column. MS data acquisition was performed in the selected ion monitoring mode, selecting three ions for each target compound. Heated water appeared to be an excellent extractant because recovery data ranged between 76 (carbaryl in spinach) and 99% (pirimicarb in spinach), with RSDs not larger than 10%. Using trimethacarb (an obsolete carbamate insecticide) as a surrogate internal standard, the accuracy of the analysis varied between 84 and 110%, with RSDs not larger than 9%. On the basis of a signal-to-noise ratio of 10, limits of quantification were estimated to range between 2 (pirimicarb) and 10 ppb (oxamyl) and were not influenced by the type of matrix. When trying to fractionate analytes by using a short chromatographic run time, marked weakening of the ion signals for oxamyl, methomyl, and aldicarb were observed. This effect was traced to polar endogenous co-extractives eluted in the first part of the chromatographic run that interfered with gas-phase ion formation for carbamates. Adopting more selective chromatographic conditions eliminated this effect.  相似文献   

8.
Liquid chromatographic determination of aflatoxin M1 in milk   总被引:1,自引:0,他引:1  
The official AOAC method for aflatoxin M1 in milk was modified by replacing cellulose column chromatography with cartridge chromatographic cleanup and replacing thin layer chromatographic (TLC) determination with liquid chromatographic (LC) quantitation to yield a new method for bovine and porcine milk. An acetone extract of milk is treated with lead acetate and defatted with hexane, and M1 is partitioned into chloroform as in the AOAC method. Chloroform is removed by evaporation under a stream of nitrogen at 50 degrees C. The residue is dissolved in chloroform, the vessel is rinsed with hexane, and the 2 solutions are applied in sequence to a hexane-activated silica Sep-Pak cartridge. Less polar impurities are removed with hexane-ethyl ether, and M1 is eluted with chloroform-methanol, and determined by C18 reverse phase LC using fluorescence detection. Recoveries of M1 added to bovine milk at 0.25, 0.50, and 1.0 ng/mL were 90.8, 93.4, and 94.1%, respectively. The limit of detection was less than 0.1 ng M1/mL for both bovine and porcine milk.  相似文献   

9.
A gas chromatographic method is described for the analysis of human milk to determine polychlorinated biphenyls (PCBs) as 72 congeners plus p,p'-DDE, mirex, hexachlorobenzene, and octachlorostyrene. The detection limit for individual compounds is about 0.05 ng/g when 30 g milk is analyzed. Total PCBs can be estimated with a detection limit of 1-5 ng/mL milk. Analytical precision is better than +/- 10% for all compounds at 20-50 ng/mL whole milk.  相似文献   

10.
A multiresidue method for the isolation and liquid chromatographic determination of oxytetracycline (OTC), tetracycline (TC), and chlortetracycline (CTC) antibiotics in milk is presented. Blank and tetracycline (OTC, TC, and CTC) fortified milk samples (0.5 mL) were blended with octadecylsilyl (C18, 40 microns, 18% load, endcapped, 2 g) derivatized silica packing material containing 0.05 g each of oxalic acid and disodium ethylenediaminetetraacetic. A column made from the C18/milk matrix was first washed with hexane (8 mL), following which the tetracyclines were eluted with ethyl acetate-acetonitrile (1 + 3; v/v). The eluate contained tetracycline analytes that were free from interfering compounds when analyzed by liquid chromatography with UV detection (photodiode array, 365 nm). Correlation coefficients of standards curves for individual tetracycline isolated from fortified samples were linear (from 0.982 +/- 0.009 to 0.996 +/- 0.004) with average percentage recoveries from 63.5 to 93.3 for the concentration range (100, 200, 400, 800, 1600, and 3200 ng/mL) examined. The inter-assay variability ranged from 8.5 +/- 2.4% to 20.7 +/- 13.0% with an intra-assay variability of 1.0-9.3%.  相似文献   

11.
An international collaborative study involving 14 collaborators from 5 different countries was conducted to test a rapid liquid chromatographic (LC) method for detecting aflatoxins M1 and M2 in fluid milk. Each collaborator prepared artificially contaminated milk samples (0.078-1.31 ng M1/mL and 0.030-0.13 ng M2/mL) by adding solutions containing various concentrations of aflatoxins M1 and M2 to fresh milk. Recoveries ranged from 85.2 to 102.5% (av. 93.7%) for aflatoxin M1 and from 99.5 to 126.7% (av. 109.8%) for aflatoxin M2. Coefficients of variation averaged 21.4% (M1) and 35.9% (M2). An analysis of variance was calculated from combined data to determine variance components. The within-laboratory variations (So) (repeatability) were 27.9% (M1) and 23.9% (M2), and the among-laboratory variations (Sx) (reproducibility) were 44.5% (M1) and 64.7% (M2). No visual differences were determined between normal or reverse phase LC for contaminated samples; however, there were an insufficient number of collaborators using normal phase to give meaningful separate statistical data. For 26 observations of uncontaminated milk, 3 false M1 positives were reported for normal phase LC determinations and 2 false M1 positives were reported for reverse phase LC determinations. Three normal phase and 11 reverse phase false M2 positives were reported for 104 observations in uncontaminated milk. The reverse phase LC method for determination of aflatoxins M1 and M2 in fluid milk has been adopted official first action.  相似文献   

12.
Several sulfonamide antimicrobials (SAAs) are largely used in veterinary medicine. A rapid, specific, and sensitive procedure for determining 12 SAAs in cheese is presented. The method is based on the matrix solid-phase dispersion technique followed by liquid chromatography (LC)-tandem mass spectrometry (MS) equipped with an electrospray ion source. Target compounds were extracted from Mozzarella, Asiago, Parmigiano, Emmenthal, and Camembert cheese samples by 6 mL of water modified with 10% methanol and heated at 120 degrees C. The addition of methanol to hot water served to improve remarkably extraction yields of the most lipophilic SAAs, that is, sulfadimethoxine and sulfaquinoxaline. After acidification and filtration, 100 microL of the aqueous extract was injected in the LC column. MS data acquisition was performed in the multireaction monitoring mode, selecting two precursor-to-product ion transitions for each target compound. Methanol-modified hot water appeared to be an efficient extractant, because absolute recovery ranged between 67 and 88%. Using sulfamoxole as surrogate analyte, recovery of the 12 analytes spiked in the five types of cheese considered at the 50 ng/g level ranged between 75 and 105% with RSD not higher than 11%. Statistical analysis of the mean recovery data showed that the extraction efficiency was not affected by the type of cheese analyzed. This result indicates this method could be applied to other cheese types not considered here. The accuracy of the method was determined at three spike levels, that is, 20, 50, and 100 ng/g, and varied between 73 and 102% with relative standard deviations ranging between 4 and 12%. On the basis of a signal-to-noise ratio of 10, limits of quantification were estimated to be <1 ng/g.  相似文献   

13.
A method was developed and validated to determine 5-hydroxyflunixin in raw bovine milk using liquid chromatography tandem mass spectrometry (LC/MS/MS). The mean recovery and percentage coefficient of variation (%CV) of 35 determinations for 5-hydroxyflunixin was 101% (5% CV). The theoretical limit of detection was 0.2 ppb with a validated lower limit of quantitation of 1 ppb and an upper limit of 150 ppb. Accuracy, precision, linearity, specificity, ruggedness, and storage stability were demonstrated. A LC/MS/MS confirmatory method using the extraction steps of the determinative method was developed and validated for 5-hydroxyflunixin in milk from cattle. Briefly, the determinative and confirmatory methods were based on an initial solvent (acetone/ethyl acetate) precipitation/extraction of acidified whole milk. The solvent precipitation/extraction effectively removed incurred ((14)C) residues from milk samples. The organic extract was then purified by solid phase extraction (SPE) using a strong cation exchange cartridge (sulfonic acid). The final SPE-purified sample was analyzed using LC/MS/MS. The methods are rapid, sensitive, and selective and provide for the determination and confirmation of 5-hydroxyflunixin at the 1 and 2 ppb levels, respectively.  相似文献   

14.
A simple, specific, and sensitive procedure for determining six cyanotoxins, that is, microcystins RR, LR, YR, LA, and LW and nodularin, in fish muscle tissue is presented. This method is based on the matrix solid-phase dispersion technique with heated water as extractant followed by liquid chromatography (LC)-tandem mass spectrometry (MS) equipped with an electrospray ion source. Target compounds were extracted from tissue by 4 mL of water acidified to pH 2 and heated at 80 degrees C. After acidification and filtration, 0.2 mL of the aqueous extract was injected in the LC column. MS data acquisition was performed in the multireaction monitoring mode, with at least two precursor ion > product ion transitions selected for each target compound. Analyte recovery ranged between 61 and 82% and was not substantially affected by either the analyte concentrations or the type of fish. The nonexcellent recovery of some of the microcystins was traced to binding of these compounds to protein phosphatases in fish tissue occurring during sample treatment. The existence of covalently bound microcystins in fish has been evidenced by several studies. Compared to an older sample preparation procedure, this one extracted larger amounts of the analytes in a simpler and much more rapid way. On the basis of a signal-to-noise ratio of 10, limits of quantification were estimated to range between 1.6 and 4.0 ng/g. The effects of temperature and volume of the extractant on the analyte recovery were studied.  相似文献   

15.
A multiresidue method for the isolation and liquid chromatographic determination of 7 benzimidazole anthelmintics (thiabendazole, oxfendazole, para-hydroxyfenbendazole, fenbendazole sulfone, mebendazole, albendazole, and fenbendazole) in milk is presented. Blank or benzimidazole-spiked milk samples (0.5 mL) were blended with octadecylsilyl (C-18, 18% load, end-capped) derivatized silica packing material. A column made from the C-18/milk matrix was first washed with hexane (8 mL), and then the benzimidazoles were eluted with methylene chloride-ethyl acetate (1 + 2, v/v; 8 mL). The eluate contained benzimidazole analytes which were free from interfering compounds as determined by UV detection (photodiode array, 290 nm). Correlation coefficients of standard curves for individual benzimidazoles isolated from spiked samples were linear (0.989 +/- 0.003 to 0.998 +/- 0.001) with recoveries ranging from 70 +/- 9% to 107 +/- 2% for the concentration range (62.5-2000 ng/mL) examined. The inter-assay variabilities ranged from 4 +/- 1% to 9 +/- 7% with intra-assay variabilities of 3-6%.  相似文献   

16.
A method was developed that is suitable for screening eggs for a variety of nonpolar residues in a single procedure. Residues are extracted by silica solid-phase extraction (SPE). Analysis is conducted via reverse-phase gradient liquid chromatography, electrospray ionization, and tandem ion trap mass spectrometry. For screening purposes (based on a single precursor-product ion transition) the method can detect ionophore (lasalocid, monensin, salinomycin, narasin) and macrolide (erythromycin, tylosin) residues in egg at approximately 1 ng/mL (ppb) and above and novobiocin residues at approximately 3 ppb and above. Conditions are described for confirmatory analysis based on multiple ions in the product ion spectrum. The extraction efficiency for ionophores was estimated at 60-85%, depending on drug. Recovery of macrolides and novobiocin was not as good (estimated at 40-55% after a hexane wash of the final extract was included), but the method consistently screened and confirmed these residues at concentrations below the target of 10 ppb. The method was applied to eggs from hens dosed with each drug individually. Lasalocid was found to have the highest probability of detection in eggs based on its high ionization efficiency and higher rate of deposition relative to the other drugs. The method is part of a larger scheme to provide surveillance methods for a wide variety of drug residues in eggs.  相似文献   

17.
Solid-phase extraction (SPE) and direct competitive chemiluminescence enzyme immunoassay (dcCL-EIA) were combined for the detection of organophosphorus pesticides (OPs) in environmental water samples. dcCL-EIA based on horseradish peroxidase labeled with a broad-specificity monoclonal antibody against OPs was developed, and the effects of several physicochemical parameters on dcCL-EIA performance were studied. SPE was used for the pretreatment of water samples to remove interfering substances and to concentrate the OP analytes. The coupling of SPE and dcCL-EIA can detect seven OPs (parathion, coumaphos, phoxim, quinalphos, triazophos, dichlofenthion, and azinphos-ethyl) with the limit of quantitation below 0.1 ng/mL. The recoveries of OPs from spiked water samples ranged from 62.5% to 131.7% by SPE-dcCL-EIA and 69.5% to 112.3% by SPE-HPLC-MS/MS. The screening of OP residues in real-world environmental water samples by the developed SPE-dcCL-EIA and their confirmatory analysis using SPE-HPLC-MS/MS demonstrated that the assay is ideally suited as a monitoring method for OP residues prior to chromatographic analysis.  相似文献   

18.
A simple liquid chromatographic (LC) method was developed to determine and identify incurred morantel-related residues in bovine milk by converting them to 3-(3-methyl-2-thienyl) acrylic acid (CP-20, 107). Key techniques in this method involve short-term digestion of milk in HCl to release residues convertible to CP-20, 107, isolation and alkaline hydrolysis of these precursors to CP-20, 107, and recovery of the product for LC analysis. Photochemical conversion of CP-20, 107 to its cis-isomer and separation by LC identifies the residue. A homolog (pyrantel), which is used as an internal standard, is hydrolyzed to 3-(2-thienyl) acrylic acid. These acrylic acid isomers are readily resolved by LC. The method was evaluated over the 1-4 ppb (ng/mL) range for accuracy and precision to assess its utility for withdrawal studies. Bovine milk supplemented with morantel at 1, 2, and 4 ppb and assayed in replicate (n = 7-8) over 4 trials gave mean values and standard deviations of 1.0 +/- 0.11, 2.0 +/- 0.24, and 4.0 +/- 0.44 ppb, respectively. A milk specimen containing physiologically incurred residues of morantel assayed 2.1 +/- 0.19 ppb in replicate (n = 5).  相似文献   

19.
An ultrahigh-performance liquid chromatography (UHPLC) tandem mass spectrometric (MS/MS) method was developed for the simultaneous quantification of 2-acetyl-4-tetrahydroxybutylimidazole (THI), 2- and 4-methylimidazoles (2-MI and 4-MI), and 5-hydroxymethylfurfural (HMF) in beverage samples. A C30 reversed-phase column was used in this method, providing sufficient retention and total resolution for all targeted analytes, with an MS/MS instrument operated in selected reaction monitoring (SRM) mode for sensitive and selective detection using isotope-labeled 4-methyl-d(3)-imidazole (4-MI-d(3)) as the internal standard (IS). This method demonstrates lower limit of quantification (LLOQ) at 1 ng/mL and coefficient of determination (r(2)) >0.999 for each analyte with a calibration range established from 1 to 500 ng/mL. This method also demonstrates excellent quantification accuracy (84.6-105% at 5 ng/mL, n = 7), precision (RSD < 7% at 5 ng/mL, n = 7), and recovery (88.8-99.5% at 10, 100, and 200 ng/mL, n = 3). Seventeen carbonated beverage samples were tested (n = 2) in this study including 13 dark-colored beverage samples with different flavors and varieties and 4 light-colored beverage samples. Three target analytes were quantified in these samples with concentrations in the range from 284 to 644 ng/mL for 4-MI and from 706 to 4940 ng/mL for HMF. THI was detected in only one sample at 6.35 ng/mL.  相似文献   

20.
Milk is typically screened for beta-lactam antibiotics by nonspecific methods. Although these methods are rapid and sensitive, they are not quantitative and can yield false positive findings. A sensitive and specific method for the quantitation and mass spectral confirmation of five beta-lactam and two cephalosporin antibiotics commonly or potentially used in the dairy industry is described using high-performance liquid chromatography with tandem mass spectrometry. The antibiotics studied were ampicillin, amoxicillin, penicillin G, penicillin V, cloxacillin, cephapirin, and ceftiofur. The antibiotics were extracted from milk with acetonitrile, followed by reversed-phase column cleanup. The extract was analyzed by liquid chromatography coupled with a mass spectrometer, using a water/methanol gradient containing 1% acetic acid on a C-18 reversed-phase column. Determination was by positive ion electrospray ionization and ion trap tandem mass spectrometry. Quantitation was based on the most abundant product ions from fragmentation of the protonated ion for amoxicillin, cephapirin, ampicillin, and ceftiofur and on the fragmentation of the sodium adduct for penicillin G, penicillin V, and cloxacillin. The method was validated at the U.S. FDA tolerance or safe level and at 5 or 2.5 ng/mL for these compounds in bovine milk. Theoretical method detection limits in milk based on a 10:1 signal to noise ratio were 0.2 ng/mL (ampicillin), 0.4 ng/mL (ceftiofur), 0.8 ng/mL (cephapirin), 1 ng/mL (amoxicillin and penicillin G), and 2 ng/mL (cloxacillin and penicillin V) using a nominal sample size of 5 mL.  相似文献   