首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
ObjectivesThe objective of this study was to evaluate the effect of age on myocardial function assessed by two-dimensional speckle-tracking echocardiography (2D-STE) in healthy dogs.AnimalsThirty-two healthy Beagles were used.MethodsMyocardial function was assessed in each dog by using 2D-STE, and the results were compared between young and old dogs.ResultsThe myocardial deformations in systole, besides the apical rotation rate, were not significantly different between young and old dogs. In contrast, the early diastolic circumferential strain rate, basal rotation rate, and torsion rate were significantly lower in old dogs than in young dogs (P = 0.03, P = 0.033, and P = 0.015, respectively). Late diastolic longitudinal and radial strain rates were significantly higher in old dogs than in young dogs (P = 0.002 and P = 0.018, respectively).ConclusionsYoung and old dogs showed similar systolic myocardial deformations, but significant differences in the values of some diastolic deformation variables were found between young and old dogs, highlighting the need for using age-matched control subjects in studies of diastolic function.  相似文献   

2.
ObjectiveThe objective of this study was to clinically assess myocardial deformations in dogs with chronic mitral valve insufficiency (CMVI) using two-dimensional speckle-tracking echocardiography (2D-STE).Animals87 dogs with CMVI.MethodsDogs were placed into 1 of 3 classes, based on the International Small Animal Cardiac Health Council classification. In addition, 20 weight- and age-matched healthy dogs were enrolled as controls. The dogs were examined for myocardial deformations using 2D-STE, and strain and strain rate in the longitudinal, circumferential, and radial directions were evaluated.ResultsClass II and III dogs had higher circumferential strain than class I dogs (P = 0.002 and P = 0.001, respectively) and controls (P < 0.001 and P < 0.001, respectively). Class III dogs had higher radial strain than class I dogs (P = 0.001) and controls (P < 0.001). Class III dogs had higher radial strain rate than class I dogs (P = 0.006) and controls (P = 0.001). Other deformations, including longitudinal deformations, were not significantly different between classes of CMVI or between CMVI dogs and controls.ConclusionsIn the clinical progression of CMVI in dogs, myocardial deformations, as assessed by 2D-STE, differed according to myocardial contractile direction. Thus, assessments of multidirectional myocardial deformations may be important for better assessment of clinical cardiac function in dogs with CMVI.  相似文献   

3.
ObjectiveTo determine the feasibility of atrial septal pacing via a delivery catheter-guided small non-retracting helix pacing lead.AnimalsSix healthy beagles (8.3-12.9 kg).MethodsUsing single plane fluoroscopic guidance, Medtronic® 3830 SelectSecure leads were connected to the atrial septum via Medtronic® Attain Select® II standard 90 Left Heart delivery catheter. Pacing threshold and lead impedance were measured at implantation. The Wenckebach point was tested via atrial pacing up to 220 paced pulses per minute (ppm). Thoracic radiographs were performed following implantation to identify the lead position, and repeated at 24 h, 1 month, and 3 months post-operatively.ResultsMacro-lead dislodgement occurred in two dogs at 24 h and in three dogs at one-month post-implantation. Lead impedance, measured at the time of implantation, ranged from 583 to 1421 Ω. The Wenckebach point was >220 ppm in four of the six dogs. The remaining two dogs had Wenckebach points of 120 and 190 ppm.ConclusionsThis pilot study suggests the selected implantation technique and lead system were inadequate for secure placement in the atrial septum of these dogs. The possible reasons for inadequate stability include unsuitable lead design for this location, inadequate lead slack at the time of implantation and inadequate seating of the lead as evidenced by low impedance at the time of implantation. Other implantation techniques and/or pacing leads should be investigated to determine the optimal way of pacing the atria in small breed dogs that are prone to sinus node dysfunction.  相似文献   

4.

Background

Left ventricular torsional motion plays an important role for effective pump function. However, noninvasive clinical assessment of torsional deformations by two‐dimensional speckle‐tracking echocardiography (2D‐STE) in dogs with myxomatous mitral valve disease (MMVD) has not been reported.

Hypothesis

Left ventricular torsion is determined by the native orientation of the helical myocardial fibers, such that it might provide better assessment of myocardial function than conventional methods.

Animals

Sixty‐seven client‐owned dogs with MMVD were classified into 3 classes based on the International Small Animal Cardiac Health Council classification and 16 weight‐ and age‐matched healthy dogs.

Methods

Dogs were examined for myocardial deformations by 2D‐STE and were evaluated for peak systolic rotation and rotation rate at each basal and apical view. Dogs also were evaluated for peak systolic torsion and torsion rate.

Results

Peak systolic torsion was higher in class II than in class I (P < .001) dogs. Peak systolic torsion was lower in class III than in class II (P = .001) dogs and controls (P = .003).

Conclusions and Clinical Importance

Torsional deformations assessed by 2D‐STE differed among clinical classes of MMVD. Myocardial torsional deformations by 2D‐STE may provide more detailed assessment of contractile function in dogs with MMVD.  相似文献   

5.
IntroductionAlternatives for out-of-clinic heart rate (HR) measurement are required to optimise the management of atrial fibrillation (AF) in dogs. Additionally, the presence of circadian variation (CV) in HR in pet dogs remains unknown.We aimed to identify the number and duration of spot-checks required for an accurate estimation of 24-hour HR in canine AF. Circadian variation in HR was examined in healthy dogs and dogs with AF, and spot-check-derived HR was compared with a CV-derived gold standard.Materials and methodsAmbulatory electrocardiogram data from healthy dogs and dogs with AF were retrospectively analysed. Heart rate was calculated from the entire recording and pre-defined periods (spot-checks) of one hour to 30 and 60 s in duration. Circadian variation in HR was determined by cosinor analysis. Bias and limits of agreement of means and median HR with mesor HR were determined by correlation and Bland–Altman analysis.ResultsCircadian variation in HR was identified not only in 18/22 healthy dogs and 14/21 AF dogs but only on ambulatory electrocardiogram recordings.Four-hourly spot-checks provided the most accurate estimate of mesor HR in healthy dogs (bias of the median over 30 s 7.70, limits of agreement 7.48), whereas, in dogs with AF, four, six and eight-hourly spot-checks provided reliable estimates of mesor HR (bias within −1.29 and −29.5).ConclusionsFour, six and eight-hourly HR spot-checks can estimate 24-hourly HR in dogs with AF. There was CV in HR in most healthy pet dogs and dogs with AF. Spot-check protocols cannot identify CV in HR.  相似文献   

6.
IntroductionIn dogs, single lead ventricular pacing, ventricular sensing, inhibition response, rate adaptive (VVIR) pacemakers are routinely used to treat third degree atrioventricular block. The objectives of this study were to investigate the heart rate distribution in dogs with VVIR pacemakers, and report changes when activity settings were adjusted.AnimalsEighteen client-owned dogs with VVIR pacemakers for third degree atrioventricular block.Materials and methodsThis observational study consisted of a review of medical records of dogs with VVIR pacemakers. For dogs with >50% of paced beats at the lower pacing rate, the activity daily living (ADL) and exertion responses were increased. Re-evaluations were performed after 6–12 months.ResultsHeart rate distribution similar to healthy dogs was absent for all dogs. In nine dogs, the ADL and exertion responses were increased to the highest level. Of these, three dogs showed no improvement in heart rate distribution; for two dogs, one with an epicardial pacemaker, several activity settings were adjusted and pacing at higher heart rates was observed at re-evaluation. Four dogs died or were lost to follow-up. Clinical signs had resolved for all dogs after pacemaker implantation.ConclusionDefault activity settings of VVIR pacemakers do not result in heart rate distribution equivalent to healthy dogs. Increasing the ADL and exertion response settings to the highest levels did not improve the pacemaker rate response. Further investigations into the role of dog size, generator positioning, pacemaker settings, and whether rate responsiveness is required for dogs' quality and quantity of life are warranted.  相似文献   

7.
ObjectiveCompare the efficacy of two cardiac pacing catheters for transesophageal atrial pacing (TAP).AnimalsTen healthy dogs.MethodsTransesophageal atrial pacing was attempted in left lateral recumbency under general anesthesia. In series, a curved electrophysiologic (EP) catheter and a straight transesophageal pacing (TP) catheter were passed transorally into the distal esophagus, caudal to the heart. Each catheter was slowly withdrawn until pacing was initiated. The catheter continued to be withdrawn in 5 mm increments until capture was no longer achieved at maximal pacing setting creating a total zone of capture (tZOC). Minimum pacing threshold (Thmin) and degree of extraneous muscle stimulation (EMS) were determined at each site.ResultsThe EP catheter achieved TAP in 10/10 dogs with a Thmin of 8.8 ± 4.8 mA and tZOC of 4.0 ± 1.7 cm. The TP catheter achieved TAP in 7/10 dogs with a Thmin of 22.5 ± 5.6 mA and tZOC of 1.2 ± 1.6 cm. No EMS was noted during TAP at Thmin using the EP catheter. Of the 7 dogs in which TAP was successful, 3/7 experienced considerable EMS at Thmin. There was no significant relationship between patient body weight and Thmin with either catheter (EP catheter P = 0.09; TP catheter P = 0.81).ConclusionsThe electrophysiology catheter captured the atria of more dogs over a larger area without EMS as compared to the TP catheter. The electrophysiology catheter is recommended for transesophageal atrial pacing in dogs.  相似文献   

8.

Background

Atrial fibrillation (AF) usually is associated with a rapid ventricular rate. The optimal heart rate (HR) during AF is unknown.

Hypothesis/Objectives

Heart rate affects survival in dogs with chronic AF.

Animals

Forty‐six dogs with AF and 24‐hour ambulatory recordings were evaluated.

Methods

Retrospective study. Holter‐derived HR variables were analyzed as follows: mean HR (meanHR, 24‐hour average), minimum HR (minHR, 1‐minute average), maximum HR (maxHR, 1‐minute average). Survival times were recorded from the time of presumed adequate rate control. The primary endpoint was all‐cause mortality. Cox proportional hazards analysis identified variables independently associated with survival; Kaplan‐Meier survival analysis estimated the median survival time of dogs with meanHR <125 bpm versus ≥125 bpm.

Results

All 46 dogs had structural heart disease; 31 of 46 had congestive heart failure (CHF), 44 of 46 received antiarrhythmic drugs. Of 15 dogs with cardiac death, 14 had CHF. Median time to all‐cause death was 524 days (Interquartile range (IQR), 76–1,037 days). MeanHR was 125 bpm (range, 62–203 bpm), minHR was 82 bpm (range, 37–163 bpm), maxHR was 217 bpm (range, 126–307 bpm). These were significantly correlated with all‐cause and cardiac‐related mortality. For every 10 bpm increase in meanHR, the risk of all‐cause mortality increased by 35% (hazard ratio, 1.35; 95% CI, 1.17–1.55; P < 0.001). Median survival time of dogs with meanHR<125 bpm (n = 23) was significantly longer (1,037 days; range, 524‐open) than meanHR ≥125 bpm (n = 23; 105 days; range, 67–267 days; P = 0.0012). Mean HR was independently associated with all‐cause and cardiovascular mortality (P < 0.003).

Conclusions and Clinical Importance

Holter‐derived meanHR affects survival in dogs with AF. Dogs with meanHR <125 bpm lived longer than those with meanHR ≥ 125 bpm.  相似文献   

9.
BackgroundEvaluation of left ventricular (LV) diastole is clinically important in cats with heart disease. Diastolic dysfunction is a main characteristic of feline cardiomyopathy and is associated with clinical signs and poor outcome. Numerous echocardiographic indices characterizing LV diastole exist, of which Doppler variables of transmitral flow and mitral annular motion are used most often. However, rapid heart rate (HR), a common finding in cats examined in the veterinary hospital environment, may cause summation of flow waves limiting interpretation of diastolic function.ObjectiveTo evaluate the effects of vagal maneuvers (gentle eyeball pressure and nasal planum massage) on HR and Doppler variables of LV diastolic filling.AnimalsTwenty-four healthy client-owned cats with summated transmitral flow waves at baseline.MethodsProspective observational study. Transthoracic echocardiography was performed and Doppler transmitral and mitral annular tissue Doppler velocities recorded both before and during vagal maneuvers. Data were compared using a paired t-test.ResultsApplication of vagal maneuvers temporarily decreased HR in all cats (mean reduction ± SD; 42 ± 22 bpm). The duration of HR reduction (<5 s, 5–10 s, and >10–15 s) was evenly distributed among groups (8 cats in each). Summated Doppler transmitral flow and mitral annular tissue velocity waves were separated during vagal maneuvers in 71% and 72% of cats, respectively. No adverse effects were observed.ConclusionsVagal maneuvers may be utilized as a simple non-pharmacologic tool in the Doppler evaluation of LV diastolic function in healthy cats.  相似文献   

10.
IntroductionHeart rate (HR) is often elevated in cats with cardiomyopathies (CMPs). Pharmacologic modulation of HR may reduce cardiac morbidity and mortality.ObjectivesTo investigate the effects of cilobradine vs. placebo, regarding time to cardiac mortality or morbidity in cats with first episode of congestive heart failure (CHF) due to primary CMP.AnimalsThree hundred and sixty-seven client-owned cats with primary CMP that had presented with a first episode of CHF at 50 centers in Europe. Per-protocol population comprised 193 cats (n = 89 cilobradine, n = 104 placebo). An interim analysis for futility was planned.MethodsProspective, randomized, placebo-controlled, double-blinded, multicenter clinical trial. Primary outcome variable was the time to a composite of cardiac mortality or cardiac morbidity.ResultsMedian time to primary outcome was 84 days (95% confidence interval [CI]: 63–219 days) in the cilobradine group (CG) and 203 days in the placebo group (95% CI: 145–377 days) with observed hazard ratio of 1.44, indicating a higher hazard for the CG (P = 0.057). Mean HR was 28 beats per minute (bpm) lower at Day 7 (P < 0.0001) and remained 29 bpm lower at Day 360 (P = 0.026) in the CG than that in the placebo group. Although the number of adverse events did not differ, there were more serious adverse events in the CG.ConclusionsHeart rate reduction by cilobradine in cats with a first episode of CHF due to primary CMP did not reduce cardiac mortality and morbidity.  相似文献   

11.
ObjectivesTo investigate the relationship of heart rate (HR) and ECG time intervals to body weight (BWT) in healthy horses and ponies. We hypothesized that HR and ECG time intervals are related to BWT.Animals250 healthy horses of >30 breeds; 5.5 (1–30) y [median (range)]; 479 (46–1018) kg.MethodsProspective study. Standard base-apex ECGs were recorded while the horses were standing quietly in a box stall. Mean HR over 15 s was calculated and RR interval, PQ interval, QRS duration, and QT interval were measured by a single observer.QT was corrected for differences in heart rate using Fridericia's formula (QTcf = QT/3√RR). The relationship between ECG variables and BWT, age, sex, and RR interval was assessed using multivariate backward stepwise regression analyses. Goodness of fit of the model was improved when using log(BWT) compared to BWT. Body weight was overall the strongest predictor of HR and ECG time intervals. Therefore, only log(BWT) was included as an independent variable in the final model. The level of significance was p = 0.05.ResultsHR (R2 = 0.21) showed a significant negative relationship and PQ (R2 = 0.53), QRS (R2 = 0.23), QT (R2 = 0.14), and QTcf (R2 = 0.02) showed significant positive relationships to log(BWT).ConclusionsSmall equine breeds undergoing routine ECG recordings have slightly faster heart rates and shorter ECG time intervals compared to larger equine breeds. Although the magnitude of absolute differences may be small, body weight needs to be considered among other factors when comparing HR and ECG time intervals to normal ranges in horses.  相似文献   

12.

Background

Hyperadrenocorticism (HAC) is associated with an increased prevalence of hypertension. This study investigated the left ventricular function using two-dimensional speckle-tracking echocardiography (2D-STE) in small breed dogs affected with spontaneous HAC.Age-matched healthy controls (n = 9), dogs with pituitary-dependent hyperadrenocorticism (PDH, n = 10), and dogs with adrenal-dependent hyperadrenocorticism (ADH, n = 9) were included in this study. Conventional echocardiography, global longitudinal and circumferential strain, and strain rate were assessed.

Results

On group-wise comparison, left ventricular free wall (LVFWd) and interventricular septal thickness in diastole (IVSd) were thickest in the ADH group, followed by the PDH and controls (P = 0.014 and P = 0.001, respectively). Neither LVFWd nor IVSd was correlated with systemic blood pressure (P = 0.238 and P = 0.113, respectively). The values of all variables derived from the global strain and strain rate in longitudinal and circumferential directions followed the same pattern: highest in the controls, followed by PDH and then ADH (all P < 0.05, respectively). On multiple regression analyses, global longitudinal strain, global longitudinal strain rate in systole and early diastole, and global circumferential strain all decreased linearly with increased IVSd (all P < 0.05).

Conclusions

Left ventricular hypertrophy (LVH) was more prevalent in the HAC group compared to the control group. Association between hypertension and development of LVH was not identified. Decreased global longitudinal and circumferential strains were associated with increased IVSd. 2D-STE revealed significant decreases in systolic functions that were undetected using conventional echocardiography in the ADH and PDH groups.  相似文献   

13.
ObjectiveTo determine if the transesophageal atrial (A) wave amplitude or ventricular (V) wave amplitude can be used to guide optimal positioning of a transesophageal pacing catheter in dogs.Study designProspective clinical study.AnimalsFourteen client owned healthy dogs with a median weight of 15.4 kg (IQR = 10.6–22.4) and a median age of 12 months (IQR = 6–12).Materials and methodsTransesophageal atrial pacing (TAP) using a 6 Fr pacing catheter was attempted in dogs under general anesthesia. The pacing catheter was inserted orally into the esophagus to a position caudal to the heart. With the pulse generator set at a rate 20 beats minute−1 above the intrinsic sinus rate, the catheter was slowly withdrawn until atrial pacing was noted on a surface electrocardiogram (ECG). Then the catheter was withdrawn in 1 cm increments until atrial capture was lost. Minimum pacing threshold (MPT) and transesophageal ECG were recorded at each site. Amplitudes of the A and V waves on transesophageal ECG were then measured and their relationship to MPT was evaluated.ResultsTAP was achieved in all dogs. In 9/14 dogs the site of lowest overall MPT was the same as the site of maximal A wave deflection. In dogs with at least three data points, linear regression analysis of the relationship between the estimated site of the lowest overall MPT compared to estimated site of the maximal A and V waveform amplitudes demonstrated a strong correlation (R2 = 0.99).Conclusion and clinical relevanceTransesophageal ECG A and V waveforms were correlated to MPT and could be used to direct the placement of a pacing catheter. However, the technique was technically challenging and was not considered to be clinically useful to guide the placement of a pacing catheter.  相似文献   

14.
ObjectiveTo compare the cardiovascular effects of a combination of medetomidine and vatinoxan (MVX) versus medetomidine (MED) alone administered intramuscularly (IM) and to determine whether heart rate (HR) can be used as a surrogate for cardiac output (CO) after the use of medetomidine with or without vatinoxan.Study designA randomized, blinded, experimental, crossover study.AnimalsA group of eight healthy Beagle dogs aged 4.6 (2.3–9.4) years and weighing 12.9 (9–14.7) kg, median (range).MethodsEach dog was injected with 1 mg m–2 medetomidine with or without 20 mg m–2 vatinoxan IM with a washout period of 7 days. Cardiovascular data and arterial and mixed venous blood gas samples were collected at baseline, 5, 10, 15, 20, 35, 45, 60, 90 and 120 minutes after treatment administration. CO was measured at all time points via thermodilution. Differences between treatments, period and sequence were evaluated with repeated measures analysis of covariance and the relationship between HR and CO was assessed with a repeated measures analysis of variance; p values < 0.05 were deemed significant.ResultsThe CO was 47–96% lower after MED than after MVX (p < 0.0001). Increases in systemic, pulmonary arterial and right atrial pressures and oxygen extraction ratio were significantly higher after MED than after MVX (all p < 0.0001). HR was significantly lower after MED and the linear relationship to CO was significant (p < 0.0001).Conclusions and clinical relevanceOverall, MED affected the cardiovascular system more negatively than MVX, and the difference in cardiovascular function between the treatments can be considered clinically relevant. HR was linearly related to CO, and decreases in HR reflected cardiac performance for dogs sedated with medetomidine with or without vatinoxan.  相似文献   

15.
ObjectiveTo compare the effects of intravenous (IV) lidocaine and fentanyl on the cough reflex and autonomic response during endotracheal intubation in dogs.Study designRandomized, blinded, superiority clinical trial.AnimalsA total of 46 client-owned dogs undergoing magnetic resonance imaging.MethodsAfter intramuscular methadone (0.2 mg kg–1), dogs were randomized to be administered either IV lidocaine (2 mg kg–1; group L) or fentanyl (7 μg kg–1; group F). After 5 minutes, alfaxalone was administered until endotracheal intubation was possible (1 mg kg–1 IV over 40 seconds followed by 0.4 mg kg–1 increments to effect). Total dose of alfaxalone was recorded and cough reflex at endotracheal intubation was scored. Heart rate (HR) was continuously recorded, Doppler systolic arterial blood pressure (SAP) was measured every 20 seconds. Vasovagal tonus index (VVTI) and changes (Δ) in HR, SAP and VVTI between pre-intubation and intubation were calculated. Groups were compared using univariate and multivariate analysis. Statistical significance was set as p < 0.05.ResultsGroup F included 22 dogs and group L 24 dogs. The mean (± standard deviation) alfaxalone dose was 1.1 (± 0.2) and 1.35 (± 0.3) mg kg–1 in groups F and L, respectively (p = 0.0008). At intubation, cough was more likely in group L (odds ratio = 11.3; 95% confidence intervals, 2.1 – 94.2; p = 0.01) and HR increased in 87.5% and 54.5% of groups L and F, respectively (p = 0.02). The median (range) ΔHR between pre-intubation and intubation was higher (13.1%; – 4.3 to + 55.1) in group L (p = 0.0021). Between groups, SAP and VVTI were similar.Conclusion and clinical relevanceAt the stated doses, whilst reducing the alfaxalone dose, fentanyl is superior to lidocaine in suppressing the cough reflex and blunting the increase in HR at endotracheal intubation in dogs premedicated with methadone.  相似文献   

16.
ObjectivesTo measure flow-mediated vasodilation (FMD) in healthy dogs and in client-owned dogs with chronic valvular disease (CVD) and to investigate possible correlations between markers of CVD severity and FMD.AnimalsTwelve dogs with CVD and 11 healthy weight-matched dogs.MethodsBrachial artery FMD following 5 min inflation of a cuff around the antebrachium was measured in 12 dogs with CVD and 11 healthy weight-matched dogs. Measurements were also obtained in the healthy dogs 5 min after cuff placement but without inflation (‘sham cuff placement’). Dogs with CVD underwent echocardiography to confirm and characterize their disease.ResultsIn healthy dogs (median age 4 [2–6] years), median FMD was 7.7% versus 3.4% with sham cuff placement (P = 0.003). In dogs with CVD (median age 8 [4–16] years) median FMD was 5.5% versus 7.7% in healthy dogs (P = 0.131). FMD showed an inverse correlation with left ventricular end-diastolic diameter normalized for body weight (r = ?0.76, P = 0.0043).ConclusionsBrachial FMD in dogs with early CVD inversely correlates with severity of left ventricular remodelling.  相似文献   

17.
This study was conducted to assess the ability of two-dimensional tissue tracking (2DTT) to evaluate changes in left ventricular (LV) myocardial function associated with sustained high electrical pacing. Pacemakers were implanted at the right ventricular (RV) apex of five female Beagles, and sustained high electrical pacing of 250 beats per minute (bpm) was performed for three consecutive weeks. Conventional echocardiography and 2DTT were performed at baseline, and at every week for three weeks with pacing. The baseline parameters were then compared to those of weeks 1, 2, and 3. Three weeks of pacing resulted in significant reduction of radial and circumferential global strains (p < 0.001). Regional analysis revealed reduction of segmental strains in both radial and circumferential directions, as well as increased dyssynchrony after three weeks of pacing in the radial direction (p = 0.0007). The results of this study revealed the ability of 2DTT to measure radial and circumferential strains in dogs with sustained high-electrical pacing, and allowed assessment of global and regional myocardial function and the degree of dyssynchrony.  相似文献   

18.
ObjectiveTo compare a Parasympathetic Tone Activity (PTA) monitor with cardiovascular changes in invasive mean arterial pressure (IMAP) and heart rate (HR) when evaluating the response to nociceptive stimuli in anaesthetized dogs.Study designProspective experimental study.AnimalsA group of nine (seven male and two female) adult Beagle dogs weighing 13.4 ± 1.5 kg (mean ± standard deviation).MethodsAnaesthesia was induced with propofol and maintained with sevoflurane in oxygen. Electrical stimuli of different nociceptive intensities were applied for 30 seconds. Stimuli were classified in each patient according to the response obtained (relevant change ≥ 20%) as low (no response), medium (PTA only) or high (PTA and IMAP/HR). Immediate and averaged values of PTA, IMAP and HR were recorded every second from 60 seconds before to 120 seconds after application of the nociceptive stimulus. Time to nociceptive response and peak response were evaluated with analysis of variance and t test.ResultsImmediate PTA baseline values did not differ significantly before application of the low, medium and high stimuli (73 ± 15, p = 0.966). Immediate PTA response was observed with the medium stimulus at 33 ± 7 seconds with a maximum decrease of 57 ± 13% at 69 ± 5 seconds. With the high stimulus, the immediate PTA response was of a similar magnitude to the medium stimulus with a response at 28 ± 7 seconds (p = 0.221) and a maximum decrease of 68 ± 15% (p = 0.115) at 72 ± 7 seconds (p = 0.436). The cardiovascular change occurred (22 ± 8 seconds) prior to the immediate PTA response (p = 0.032).Conclusions and clinical relevanceThe PTA monitor detected nociceptive stimuli at lower intensities than those eliciting cardiovascular changes. However, nociceptive stimuli of higher intensities provoked cardiovascular changes that occurred before a PTA response was observed.  相似文献   

19.
ObjectiveTo compare the effect of alfaxalone and propofol on heart rate (HR) and blood pressure (BP) after fentanyl administration in healthy dogs.Study designProspective, randomised clinical study.AnimalsFifty healthy client owned dogs (ASA I/II) requiring general anaesthesia for elective magnetic resonance imaging for neurological conditions.MethodsAll dogs received fentanyl 7 μg kg−1 IV and were allocated randomly to receive either alfaxalone (n = 25) or propofol (n = 25) to effect until endotracheal (ET) intubation was possible. Heart rate and oscillometric BP were measured before fentanyl (baseline), after fentanyl (Time F) and after ET intubation (Time GA). Post-induction apnoea were recorded. Data were analysed using Fisher’s exact test, Mann Whitney U test and one-way anova for repeated measures as appropriate; p value <0.05 was considered significant.ResultsDogs receiving propofol showed a greater decrease in HR (-14 beat minute−1, range -47 to 10) compared to alfaxalone (1 beat minute−1, range -33 to 26) (p = 0.0116). Blood pressure decreased over the three time periods with no difference between groups. Incidence of post-induction apnoea was not different between groups.ConclusionFollowing fentanyl administration, anaesthetic induction with propofol resulted in a greater negative chronotropic effect while alfaxalone preserved or increased HR.Clinical relevanceFollowing fentanyl administration, HR decreases more frequently when propofol rather than alfaxalone is used as induction agent. However, given the high individual variability and the small change in predicted HR (-7.7 beats per minute after propofol), the clinical impact arising from choosing propofol or alfaxalone is likely to be small in healthy animals. Further studies in dogs with myocardial disease and altered haemodynamics are warranted.  相似文献   

20.
ObjectiveTo compare the sedative and clinical effects of intravenous (IV) administration of dexmedetomidine and xylazine in dromedary calves.Study designExperimental, crossover, randomized, blinded study.AnimalsA total of seven healthy male dromedary calves aged 14 ± 2 weeks and weighing 95 ± 5.5 kg.MethodsCalves were assigned three IV treatments: treatment XYL, xylazine (0.2 mg kg−1); treatment DEX, dexmedetomidine (5 μg kg−1); and control treatment, normal saline (0.01 mL kg−1). Sedation scores, heart rate (HR), respiratory rate (fR), rectal temperature (RT) and ruminal motility were recorded before (baseline) and after drug administration. Sedation signs were scored using a 4-point scale. One-way anova and Mann–Whitney U tests were used for data analysis.ResultsCalves in treatments XYL and DEX were sedated at 5–60 minutes. Sedation had waned in XYL calves, but not DEX calves, at 60 minutes (p = 0.037). Sedation was not present in calves of any treatment at 90 minutes. HR decreased from baseline in XYL and DEX at 5–90 minutes after drug administration and was lower in DEX than XYL at 5 minutes (p = 0.017). HR was lower in DEX (p = 0.001) and XYL (p = 0.013) than in control treatment at 90 minutes. fR decreased from baseline in XYL and DEX at 5–60 minutes after drug administration and was lower in DEX than XYL at 5 minutes (p = 0.013). RT was unchanged in any treatment over 120 minutes. Ruminal motility was decreased in XYL at 5, 90 and 120 minutes and absent at 10–60 minutes. Motility was decreased in DEX at 5, 10 and 120 minutes and was absent at 15–90 minutes.Conclusion and clinical relevanceThe duration of sedation from dexmedetomidine (5 μg kg–1) and xylazine (0.2 mg kg–1) was similar in dromedary calves.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号