首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A liquid chromatographic (LC) method has been developed for determination of thiamine in infant formula products. The method involves the following steps: (a) dissolution of the formula with water, (b) pH adjustment to induce protein precipitation, (c) filtration, (d) concentration of thiamine by using a cation exchange column and extraction system, (e) cleanup of adsorbed thiamine and other contaminants on the ion exchange column by washing with water and then methanol, (f) elution of thiamine with a mixture of methanol-2M potassium chloride buffer, (g) analysis for thiamine by liquid chromatography. Thiamine is separated from its phosphate esters, the mono-, di-, and triphosphates, as well as its antagonists oxythiamine and pyrithiamine on a 6 micron particle size column and a mobile phase of 40mM triethyl-ammonium phosphate buffer-methanol (pH 7.7) (90 + 10). The method is reproducible, with relative standard deviations ranging from +/- 0.76 to +/- 1.2%, depending on the infant formula product tested. Recovery of thiamine from various infant formula products is greater than 99%. Analysis for thiamine of several commercially available infant formulas at different levels of fortification gave results that ranged from 122 to 216% of the declared levels. These results agree well with those obtained using the AOAC fluorometric method.  相似文献   

2.
Vitamin D2 or vitamin D3 is determined by liquid chromatography (LC) in milk and infant formula. Vitamin D is extracted from the saponified sample, passed through an amino-cyano LC cleanup column to remove major interferences, and quantitated using normal phase LC. Within-day precision is 4.5% relative standard deviation (RSD); the overall method RSD (reflecting technician-to-technician, day-to-day, and within-day variability) is 7.7%. Overspike recoveries averaged 97% for milk, 98% for milk-based infant formula, and 93% for soy-based infant formula. The performance of the method is compared with that of the official AOAC vitamin D method (rat bioassay). The method is applicable to the determination of vitamin D in milk and in the major milk- and soy-based infant formulas available in the United States. The method can quantitate (but not distinguish) either vitamin D2 or vitamin D3. The method is applicable to milk and infant formula samples containing between 100 and 1500 IU vitamin D/L. Sample throughput is between 4 and 8 replicates per day.  相似文献   

3.
The normal phase liquid chromatographic (LC) method for determination of trans- and cis-isomers of vitamin K1 (phylloquinone) in infant formula described here uses an Apex silica column, isocratic elution, and UV absorption detection at 254 nm. Vitamin K1 is extracted quantitatively from the product matrix by pretreating the as-fed liquid with concentrated ammonium hydroxide and methanol, and then extracting it with a 2:1 mixture of dichloromethane and isooctane. The extract is cleaned up by silica open-column chromatography and concentrated for LC analysis. For trans-vitamin K1, the method precision is less than or equal to 3.3% RSD (relative standard deviation), and the spike recovery is 98 +/- 4%. For cis-vitamin K1, the precision is less than or equal to 12% RSD, determined at levels near the detection limit, and the spike recovery is 95 +/- 9%. The detection limit is 0.3 ng for both isomers at signal/noise = 3.  相似文献   

4.
A method is described for the determination of vitamins D2 + D3 in milk- and soy-based infant formula. Vitamins D2 and D3 are extracted from the saponified sample and converted to isotachysterols with acidified butanol. Reverse-phase liquid chromatography (LC) is used to remove interferences, and total vitamin D is quantitated using normal-phase LC. Recoveries of spiked samples averaged 97.6% for milk-based infant formula, and 98.8% for soy-based infant formula. This method quantitates vitamin D2 + D3 in infant formulas containing as low as 40 IU/qt when prepared according to label direction.  相似文献   

5.
A liquid chromatographic (LC) method was developed for determining vitamins D2 and D3 in fortified milk and infant formulas. The lipid-soluble components were extracted from the aqueous phase by homogenizing in isopropanol-methylene chloride with magnesium sulfate added to remove water. The vitamins were fractionated from the lipid material by using gel permeation chromatography (GPC) followed by further cleanup of the combined GPC fractions on a muBondapak/NH2 column. Four muStyragel (100 A) columns connected in series were used for GPC fractionation of sample extracts in methylene chloride. Injection and collection were repeated 3 times to collect enough vitamin D for quantitation. The muBondapak/NH2 column, using a mobile phase of methylene chloride-isooctane-isopropanol (600 + 400 + 1), resolved vitamin D from other UV-absorbing compounds and soy sterols in infant formula and from cholesterol in milk. Vitamins D2 and D3 coeluted as one peak, with the resolution and vitamin level sufficient for visual monitoring (280 nm/0.02 absorbance unit full scale) in a collection time of 22-26 min. A Zorbax ODS (6 micron) column and a methylene chloride-acetonitrile-methanol (300 + 700 + 2) mobile phase were used for LC quantitation; vitamins D2 and D3 were baseline resolved in about 11 min. The infant formula samples included ready-to-use and concentrated liquids prepared in nonfat milk base or soy base fortified with vitamins D2 or D3 at 400 IU/qt or L (10 micrograms). The mean percent recovery of added vitamin D3 (400-500 IU/qt) from infant formula (n = 7) was 89.6 +/- 6.7 (coefficient of variation (CV) 7.5%).(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

6.
Commercial infant formulas were analyzed simultaneously for thiamine and riboflavin by an automated fluorometric method and by the AOAC manual fluorometric methods. For 10 products, the mean thiamine and riboflavin results determined using the automated method ranged from 104 to 113% and 90 to 112%, respectively, of those by the AOAC manual methods. The coefficients of variation for thiamine and riboflavin ranged from 1.05 to 3.90% and 0.60 to 2.48%, respectively, for the automated methods, and 1.48 to 3.86% and 0.69 to 10.9%, respectively, for the manual methods. Using the automated method, mean recoveries of thiamine and riboflavin added to samples were 103 and 104%, respectively. The automated method used a common sample preparation to determine both thiamine and riboflavin, and gave results equivalent to, or better than, those obtained by the manual methods.  相似文献   

7.
A fast and simple method for determination of taurine in infant formulas has been developed. The sample preparation uses disposable ultrafiltration cartridges to remove protein and clarify the sample. Hydrolysis is avoided, simplifying the procedure and increasing efficiency. One mL sample is centrifuged in a cartridge for 45 min. The filtrate is diluted with pH 2.2 citrate buffer and injected into a high performance amino acid analyzer. A cation-exchange column (sodium phase) is used with a single buffer eluant and an isocratic chromatographic program. Colorimetric detection is performed following post-column ninhydrin reaction. Chromatographic resolution from other ninhydrin-positive compounds is excellent. Average recoveries for 3 levels of spike for various products were 100-102%. Precision is 1-3% RSD, depending on product. Linearity, specificity, and ruggedness are excellent. The method is applicable to quality control testing of milk-based, soy-based, and prehydrolyzed protein-based infant formulas in the ready-to-use, concentrate, and powder forms. A variety of commercially available infant formulas from different manufacturers were analyzed and all were found to contain taurine levels comparable to human milk. Some human milk and cow's milk samples were also analyzed and results compare well with literature values.  相似文献   

8.
A simple and rapid method is presented for the liquid chromatographic assay of ascorbic acid, niacinamide, pyridoxine, thiamine, and riboflavin from a single chromatogram. Ion-pair chromatography with a reverse phase C18 cartridge in a radial compression system is used. Quantitation is excellent with a total analysis time of less than 20 min. A mobile phase of methanol-water (15 + 85) (0.005M heptanesulfonic acid) with 0.5% triethylamine at pH 3.6 and a flow rate of 2.0 mL/min gives the most satisfactory separation of the 5 water-soluble vitamins. By using 2 detectors in series set at different wavelengths and sensitivities, all 5 vitamins, with peak heights on scale, can be measured from a single injection; peak elution order is ascorbic acid, niacinamide, pyridoxine, thiamine, and riboflavin. Ascorbic acid is measured at 254 nm and the other vitamins, at 280 nm. The amount of amine modifier in the mobile phase is critical to the separation of niacinamide and pyridoxine. Recoveries of 5 water-soluble vitamins from spiked placebos were in the range of 98.2-102.0%. Confidence limits, +/- 3 SD, were in the range of 1.0-5.4%. Overall, the results obtained using the liquid chromatographic method show excellent agreement with manual methods and automated analysis.  相似文献   

9.
As a consequence of the adulteration of infant formulas and milk powders with melamine (MEL) in China in 2008, much attention has been devoted to the analysis of MEL [and cyanuric acid (CA)] in dairy products. Several methods based on high-performance liquid chromatography (HPLC), liquid chromatography-tandem mass spectrometry (LC-MS/MS), nuclear magnetic resonance (NMR), or Raman spectroscopy have been described in the literature. However, no method is available for the simultaneous determination of MEL and CA in other raw materials, which are considered as high-risk materials for economically motivated adulteration. The present paper reports the results of an interlaboratory-based performance evaluation conducted with seven laboratories worldwide. The purpose was to demonstrate the ability of a cleanup-free LC-MS/MS method, originally developed for cow's milk and milk-powdered infant formula, to quantify MEL and CA in egg powder and soy protein. Limit of detection (LOD) and limit of quantification (LOQ) were 0.02 and 0.05 mg/kg for MEL in egg powder and soy protein, respectively. For CA, LOD and LOQ were 0.05 and 0.10 mg/kg in egg powder and 1.0 and 1.50 mg/kg in soy protein, respectively. Recoveries ranged within a 97-113% range for both MEL and CA in egg powder and soy protein. Reproducibility values (RSD(R)) from seven laboratories were within a 5.4-11.7% range for both analytes in the considered matrices. Horwitz ratio (HorRat) values between 0.4 and 0.7 indicate acceptable among-laboratory precision for the method described.  相似文献   

10.
A rapid method for the determination of sub-part-per-million levels of copper in infant formula, which does not require decomposition of the sample matrix before analysis, has been developed. The method uses L'vov platform graphite furnace atomic absorption spectroscopy (GFAAS), a technique that greatly reduces matrix interferences limiting the applicability of normal GFAAS. The sample preparation consists of dilution of a weighed sample of infant formula to a known volume with a 0.5% solution of Triton X-100 in deionized water. The accuracy of the method, as assessed from the results of overspike recovery studies (96.5-101.3% recovery) for different matrix types and comparison to results generated with alternative methodologies, can be considered excellent. The overall precision of the method ranges from 2.5 to 4.3% RSD for different matrix types.  相似文献   

11.
OBJECTIVE: To determine the nutrient composition of complementary foods consumed by 6-12-month-old South African infants. DESIGN: Nutrient intake was determined for infants who were recruited to participate in a randomised controlled trial using a single 24-hour dietary recall. SETTING/SUBJECTS: Infants aged 6-12 months (n=475) residing in The Valley of a Thousand Hills, a rural area in KwaZulu-Natal, South Africa. RESULTS: Energy and protein intakes from complementary foods were adequate. Infants who consumed infant products (commercially available fortified infant cereals/ready-to-eat canned baby foods/formula milk powder) had significantly higher intakes of calcium, iron, zinc, vitamin A, thiamine, riboflavin, niacin, vitamin B6, vitamin B12 and vitamin C than infants who did not consume any infant products. For infants who consumed infant cereals (n=142), these cereals provided 51% of total iron intake. Infant cereals provided more than 25% of total intake for magnesium, thiamine, niacin and vitamin B12. For infants consuming ready-to-eat canned baby foods (n=77), these products contributed less than 15% of total intake for all the micronutrients. The nutrient density of the complementary diet was less than half the desired density for calcium, iron and zinc. Animal products were consumed by 17% of infants, 26% consumed dairy products and 18% consumed vitamin-A-rich fruit and vegetables during the 24-hour recall period. CONCLUSION: The nutrient composition of complementary foods among rural South African infants was inadequate, especially for iron, zinc and calcium. Strategies should be developed to improve the nutritional quality of their diets.  相似文献   

12.
A rapid method employing static headspace gas chromatography (HS-GC) has been developed and validated for quantitative analysis of the impact aroma compound, 2-acetyl-1-pyrroline (2AP), in grains of fragrant rice. This developed method excludes wet extraction, and the rice headspace volatiles are brought directly and automatically to GC analysis. The conditions of the static HS autosampler were optimized to achieve high recovery and sensitivity. The most effective amount of rice sample used was 1 g, which provided 51% recovery and a linear multiple headspace extraction (MHE) plot of the peak area of 2AP. The sensitivity of the method was enhanced by utilizing a megabore fused silica capillary column in conjunction with a nitrogen-phosphorus detector (NPD). Method validations performed for both static HS-GC-FID and HS-GC-NPD demonstrated linear calibration ranges of 20-10 000 (r(2) = 0.9997) and 5-8000 (r(2) = 0.9998) ng of 2AP/g of rice sample, respectively. The limits of detection for both systems were 20 and 5 ng of 2AP, and the limits of quantitation were 0.30 and 0.01 g of brown rice sample, respectively. Reproducibility calculated as intraday and interday coefficients of variation were 3.25% RSD (n = 15) and 3.92% RSD (n = 35), respectively, for SHS-GC-FID and 1.87% RSD (n = 15) and 2.85% RSD (n = 35), respectively, for SHS-GC-NPD. The method was found to be effective when applied to the evaluation of aroma quality, based on 2AP concentrations, of some fragrant rice samples.  相似文献   

13.
Nucleotide-supplemented infant formula has been shown to positively modify the composition of intestinal microflora, emulating the attribute of human milk. Quantification of nucleotides in infant formula is of interest because of its applicability in quality and safety assessments. There is no standard method for the analysis of nucleotides in infant formula. In the present study, ion-exchange liquid chromatography (IELC)- and centrifugal ultrafiltration (CUF)-based protocols were developed for routine determination of additive nucleotides in infant formula. Five target nucleotides, guanosine 5'-monophosphate (GMP), inosine 5'-monophosphate (IMP), uridine 5'-monophosphate (UMP), cytidine 5'-monophosphate (CMP), and adenosine 5'-monophosphate (AMP) were measured by IELC with a mobile phase of 50 mM diammonium hydrogen phosphate buffer, pH 4.0, with UV detection at 254 nm. The calibration was linear over the range 0.5-50 microg/mL; R(2) = 0.999. The calculated LOD and LOQ were 0.01-0.05 microg/mL and 0.05-0.5 microg/mL, respectively. Recovery values (spiked concentration levels: 0.5, 5, and 10 microg/mL) ranged from 85.0 +/- 1.4% to 92.3 +/- 2.1% using only CUF preparation. This was applied to measure the concentration of five nucleotides in common infant formulas.  相似文献   

14.
Immunoglobulin-containing food products and nutraceuticals such as bovine colostrum are of interest to consumers as they may provide health benefits. Commercial scale colostrum products are valued for their immunoglobulin G (IgG) content and therefore require accurate analysis. One of the most commonly used methods for determining total soluble IgG in colostrum products is based on affinity chromatography using a Protein G column and UV detection. This paper documents improvements to the accuracy of the Protein G analysis of IgG in colostrum products, especially those containing aggregated forms of IgG. Capillary electrophoresis-sodium dodecyl sulfate (CE-SDS) analysis confirmed that aggregated IgG measured by Protein G does not contain significant amounts of casein or other milk proteins. Size exclusion chromatography identified the content of soluble IgG as mainly monomeric IgG and aggregated material MW > 450 kDa with small amounts of dimer and trimer. The turbidity of the eluting IgG, mainly associated with aggregated IgG, had a significant effect on the quantitative results. Practical techniques were developed to correct affinity LC data for turbidity on an accurate, consistent, and efficient basis. The method was validated in two laboratories using a variety of colostrum powders. Precision for IgG was 2-3% (RSD(r)) and 3-12% (RSD(R)). Recovery was 100.2 ± 2.4% (mean ± RSD, n = 10). Greater amounts of aggregated IgG were solubilized by a higher solution:sample ratio and extended times of mixing or sonication, especially for freeze-dried material. It is concluded that the method without acid precipitation and with turbidity correction provides accurate, precise, and robust data for total soluble IgG and is suitable for product specification and quality control of colostrum products.  相似文献   

15.
A creative and sensitive method has been developed for the determination of triterpene glycosides concentrations in sea cucumber ( Stichopus japonicus) and related products by using d-quinovose (6-deoxyglucose) as the measurement standard by reverse-phase high-performance liquid chromatography (HPLC) and variable-wavelength detection. d-quinovose, which is a unique monosaccharide in holostane triterpene glycosides, was liberated by acid hydrolysis and precolumn derivatized by 1-phenyl-3-methyl-5-pyrazolone (PMP). PMP-quinovose was analyzed by HPLC with 22% acetonitrile in 0.05 M KH2PO4 aquatic solution (pH 5.2) as mobile phase. The calibration curves of d-quinovose were linear within the range of 6.56-164 mg/L (r(2) > 0.995). The contents of triterpene glycosides in various S. japonicus products were determined after appropriate pretreatment methods. The concentration of triterpene glycosides was calculated by the formula C = C(qui) x alpha (alpha = 8.5). The result showed that this method was a simple, rapid, and stable method for the determination of triterpene glycosides in S. japonicus products.  相似文献   

16.
A sensitive, efficient, and reproducible method, based on solid phase extraction and derivatization with acetic anhydride followed by gas chromatography-mass spectrometry in selected-ion monitoring mode, was developed for the determination of bisphenol A (BPA) in liquid infant formula. The method quantification limit was 0.5 ng g(-1). Extraction recoveries were 85-94% over the concentration range of 2.5-20 ng g(-1). Good reproducibility of the method was observed at levels of 0.54 and 10.4 ng g(-1) with relative standard deviations of 5.0 and 2.8%, respectively. The method was used to analyze samples of 21 canned liquid infant formula products for BPA. BPA was detected in all samples at levels ranging from as low as 2.27 ng g(-1) to as high as 10.2 ng g(-1). The probable daily intakes of BPA due to consumption of canned liquid infant formula were estimated for infants from premature to 12-18 months of age. The maximum probable daily intake of BPA was 1.35 microg kg(-1) of body weight day(-1) for 0-1-month-old infants with the maximum formula intake, which is below the provisional tolerable daily intake for BPA established by Health Canada, 25 microg kg(-1) of body weight day(-1).  相似文献   

17.
Thiamine and its mono- and pyrophosphate esters were determined in beer and the raw materials used for its manufacture (brewer's yeast, malt, raw grain, and hops) after separation using reversed-phase liquid chromatography. The method used fluorescence detection and a new amide-based stationary phase, which avoids the need to form ion pairs, leading to narrower peaks and a simpler mobile phase. Analyses were performed by isocratic elution with a phosphate buffer mobile phase and using a postcolumn derivatization system based on the oxidation of thiamine to fluorescent thiochrome with potassium ferricyanide in alkaline solution. Only thiamine was found in the beers and raw products, especially in brewer's yeast and malt. A stability study pointed to a faster decrease in the thiamine content of samples stored at room temperature and in sunlight.  相似文献   

18.
A liquid chromatography electrospray ionization tandem mass spectrometry method for the determination of patulin in apple- and pear-based foodstuffs was developed. The sample preparation is based on the QuEChERS procedure involving an initial extraction step with water and acetonitrile, followed by a partitioning step after the addition of magnesium sulfate and sodium chloride. The cleanup was performed by using dispersive solid-phase extraction with a mixture of magnesium sulfate, primary secondary amine sorbent, and n-octadecylsiloxane sorbent added together to the extract. The cleaned extract was finally evaporated and reconstituted in water prior to injection. Quantitation was performed by isotope dilution using ((13)C(7))-patulin as internal standard. The method was first fully validated in three different baby food products including apple-pear juice, apple-pear puree, and infant cereals. Then the scope of application of the method was extended to pear concentrate, raw apples, apple flakes (naturally contaminated), dried apples, and yogurt. The sensitivity achieved by the method in all matrices gave limits of detection (LOD) and quantitation (LOQ) of ≤0.5 and ≤10 μg/kg, respectively, which was compliant with maximum levels settled in Commission Regulation (EC) No. 1881/2006. Method performances for all matrices also fulfilled the criteria established in the CEN/TR 16059:2010 document. Indeed, recoveries were within the 94-104% range; relative standard deviations of repeatability (RSD(r)) and intermediate reproducibility (RSD(IR)) were ≤7.5 and ≤13.0%, respectively, and trueness in an infant apple drink (FAPAS 1642) was measured at 99%.  相似文献   

19.
An on-line supercritical fluid extraction (SFE)/enzymatic hydrolysis procedure using immobilized lipase has been developed for the determination of vitamin A in dairy and meat products. Several lipases were tried, of which Novozyme 435 (Candida antarctica type B) showed the highest activity toward retinyl palmitate. There was no observed activity with alpha-tocopheryl acetate. When pressure, temperature, modifiers, flow rate, extraction time, and water content were varied, high vitamin A recovery was obtained in milk powder. Collected extracts were analyzed by reversed-phase high-performance liquid chromatography with ultraviolet and fluorescence detection without additional sample cleanup. The procedure gave reliable values of vitamin A as well as of vitamin E in other food items such as infant formula, minced pork and beef meat, and low- and high-fat liver paste. The described method is faster and more automated than conventional methods based on liquid-liquid extraction, or SFE using off-line saponification, for vitamin A and E determination. Results obtained with the new method did not differ significantly from those obtained with the other two methods mentioned above.  相似文献   

20.
A high-performance liquid chromatography (HPLC) method for the qualitative and quantitative analysis of allantoin in silk and seed of Zea mays has been developed. Allantoin separation in crude extract was achieved using a C 18 column and phosphate buffer solution (pH 3.0) as a mobile phase at ambient temperature at a flow rate of 1.0 mL/min and detected at 210 nm. The results showed that the amount of allantoin in samples was between 14 and 271 mg/100 g of dry plant material. A comprehensive validation of the method including sensitivity, linearity, repeatability, and recovery was conducted. The calibration curve was linear over the range of 0.2-200 microg/mL with a correlation coefficient of r2>0.999. Limit of detection (LOD, S/N=3) and limit of quantification (LOQ) values of the allantoin were 0.05 and 0.2 microg/mL (1.0 and 4.0 ng) respectively. The relative standard deviation (RSD) value of the repeatability was reported within 1.2%. The average recovery of allantoin added to samples was 100.6% with RSD of 1.5%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号