1.
Nail-head pull-through, lateral nail resistance, and single shear nailed joint tests were conducted on medium density fiberboard (MDF) with different density profiles, and the relations between the results of these tests and the density profiles of MDF were investigated. The maximum load of nail-head pull-through and the maximum load of nailed joints were little affected by the density profile. However, the ultimate strength of lateral nail resistance, the stiffness, and the yield strength of nailed joints were affected by the density profile of MDF and showed high values when the surface layer of the MDF had high density. It is known that bending performance is also influenced by density profile. Therefore, the stiffness and the yield strength of nailed joints were compared with the bending performance of MDF. The stiffness of nailed joints was positively correlated with the modulus of elasticity (MOE); in the case of CN65 nails, the initial stiffness of joints changed little in response to changes in MOE. The yield strength of nailed joints had a high positive correlation with the modulus of rupture (MOR). The stiffness and the yield strength of nailed joints showed linear relationships with MOE and MOR, respectively.  相似文献   

2.
Nailed timber joints are widely used in timber structures, and their deterioration may cause significant damage. We investigated the withdrawal strength of joints using steel wire nails in specimens exposed to a brown-rot fungus. We also examined the effects of nail corrosion on withdrawal strength, because high humidity conditions accelerate not only wood decay but also the corrosion of nails. We found that nail corrosion increased the withdrawal strength. The ratios of withdrawal strength of nailed joints with rusted nails to that of joints with a minimally rusted nails were 1.47 and 1.56 in joints nailed in radial and tangential directions to annual rings, respectively. Withdrawal strength, excluding the effects of nail corrosion, had a negative correlation with mass loss and Pilodyn-pin-penetration-depth-ratio. We estimated the withdrawal strength of the nailed joint with decayed wood and rusted nails by multiplying the values from the empirical formula (obtained from mass loss and Pilodyn-pin-penetration-depth-ratio) by 1.47 and 1.56 for joints nailed in radial and tangential direction to annual rings, respectively.  相似文献   

3.
We used a two-dimensional finite element method to analyze the load-slip characteristics of nailed wooden joints sheathed with a panel. We used tests of nail bending, nail shank embedment in a wood or a panel, nail-head embedment in a face of a panel, nail withdrawing from a wood, friction between a wood and a panel, and initial axial forces of the nails. The values of the material properties for the analytical models were determined with the above tests. With a conventional one-dimensional analysis it is impossible to evaluate the shearing performance accurately because the axial forces of the nail are not calculated. Therefore, we used two-dimensional geometric nonlinear analysis. The computed load-slip curves closely matched the original experimental results; and when the friction and initial axial forces were considered, the computed curves were more likely to match the original experimental results. Our results suggested that it is better to use geometric nonlinear analysis to analyze the shearing characteristics of nailed joints, and that friction and axial forces are important factors for accurate analysis.Parts of this report were presented at the 7th World Conference on Timber Engineering, Malaysia, August 2002  相似文献   

4.
In this study, an experimental study was conducted on the nailed timber–plywood–timber joints extended from the standard wall–floor joints of wooden light frame constructions, where the bottom plates of shear walls are nailed to the floors consisting of joists and floor sheathings nailed to them. The principal conclusions are as follows: The allowable lateral resistance of the nailed timber–plywood–timber joints can roundly be estimated by neglecting the plywood panels if their densities are higher than those of the timber main-members and they are fastened effectively onto the timber main-members. The stiffness of the timber–plywood–timber joints is less than that of the control timber–timber joints, which is improved by increasing the number of nails used to fasten the plywood panels onto the timber main-members. The stiffness of the joints whose floor sheathings are glued onto the joists is equivalent to the control timber–timber joints. The timber–plywood–timber joints with appropriate specifications have greater energy capacity until the failure than that of the control timber–timber joints. This ensures their energy capacity, which is important in dynamic resistance, to be equivalent to the control timber–timber joints.  相似文献   

5.
Summary Applying modern methods of analyzing floor, wall, and connection subsystems in light-frame wood buildings requires information on the stiffness of nailed joints under long-term loads. Because this information can best be derived by testing nail-joint specimens under constant loads, theoretical procedures were developed that use test data for constant loads to predict stiffness under variable in-service loads; five nonlinear, viscous-viscoelastic models were develpoed on the basis of existing formulations of creep and mechanisms of load transfer between nails and wood. The models incorporated the modified superposition and strain-hardening principles in describing responses to discrete or continuous loading functions. Tests have shown that the models closely predict creep slip of typical nailed joints.This research was jointly supported by the Forest Research Laboratory, Oregon State University, and the Cooperative State Research Service, U.S. Department of Agriculture, Special Grant 85-CRSR-2-2553. This is Paper 2288 of the Forest Research LaboratoryFormerly Graduate Research Assistant Forest Research Laboratory  相似文献   

6.
钉连接是木结构中常用的连接方式之一。依据美国钉连接的试验方法及设计值的确定方法,对我国东北地区落叶松的钉连接性能进行了检测。结果表明,随着圆钉直径的增大,落叶松的抗拔出力和抗剪切力基本呈上升趋势。并对东北地区落叶松钉连接的参考设计值进行了分析。  相似文献   

7.
Dynamic tests of nailed plywood–timber joints are conducted under harmonic vibrations from 2 to 7 Hz. The principal results are as follows: under dynamic loading, nailed plywood–timber joints may break in low-cyclic bending fatigue failure of nails besides the other failure modes typical under static loading. The dynamic response of nailed plywood–timber joints is clearly dependent upon both the input frequency and the acceleration. These responsive characteristics arise from the nonlinear load–slip relationships and the characteristic cyclic stiffness degradation of nailed joints; that is, the cyclic degradation of the equivalent linear stiffness decreases the resonant frequencies of the same joints, which results in a transition of dynamic responses. It indicates that frequency components of seismic waves resonant to the frequencies corresponding to safety-limit stiffness of nailed joints may lead them to critical failures, even if the accelerations do not exceed the accelerations equivalent to the static damage-limit resistance.  相似文献   

8.
The performance of plywood-sheathed shear walls is determined at the plywood-to-timber joints. In joints with dowel-type fasteners, such as nails and screws, the fastener is fractured under reversed cyclic loading (e.g., seismic force), reducing the ductility of the joint. The fracture is caused by low-cycle fatigue due to the reversed cyclic bending of the fastener. Therefore, evaluating the fatigue life is important for estimating the ultimate displacement. The main objective of this study is to estimate the ultimate displacement of the joints and to enable load–displacement calculation of single shear joints under reversed cyclic displacement when bending fatigue failure of the fastener occurs. Single shear tests were conducted under different loading protocols, and the damage performances of the fasteners were determined by subjecting them to reversed cyclic bending tests. Based on the results, the failure lifetimes of joints with dowel-type fasteners were estimated. In addition, the fracture mechanism of these dowel-type fasteners was elucidated. CN50-type nails and wood screws with dimensions of 4.1?×?38 and 4.5?×?50 mm were used as fasteners. The single shear tests showed that the smaller the displacements per cycle, the lower are the ultimate displacement and ductilities of the joints. Moreover, load–displacement relationship up to fastener failure can be approximately estimated by combining the yield model and failure lifetime.  相似文献   

9.
戴璐  肖浩楠 《林产工业》2020,57(1):29-36
基于Abaqus有限元分析,对不同榫长的实木榫卯连接梁柱节点和榫长为75 mm的不同层数的正交胶合木(CLT)榫卯连接梁柱节点进行数值模拟,分析其受力状态并提取荷载-位移曲线,与使用金属连接件连接的梁柱节点承载力进行对比,探究将榫卯连接应用在现代木结构中的理论依据。研究表明:竖向荷载作用下,榫长75 mm的榫卯连接梁柱节点承载能力处于M8和M10螺栓连接梁柱节点的理论承载力之间;当榫长增大时,节点的最大承载力逐渐提高,榫长150 mm的榫卯节点承载力已经略微超过M12螺栓连接时的理论承载强度,说明榫卯连接梁柱节点在承载能力上可以满足现代木结构建筑的使用要求。由于榫卯节点的承载力主要受到顺纹抗压强度的影响,因此相比于实木连接榫卯节点,CLT榫卯节点的承载力无显著提高。  相似文献   

10.
To investigate the effect of moisture content (MC) of members on the mechanical properties of timber joints, bending tests of precut joints and shear tests of dowel-type joints were carried out using timbers of Japanese cedar (Cryptomeria japonica D. Don) with three moisture conditions: green, kiln-dried with a MC target of 15%, and over-kiln-dried with a MC target of 5%. For the bending test, timbers were processed with a precut processing machine into “koshikake-ari” (a kind of dovetail joint) and “koshikake-kama” (a kind of mortise and tenon joint). A pair of members was jointed together without mechanical fasteners. Bolts (diameter = 12 mm) and nails (diameter = 2.45 mm) were used as dowels in the shear test. Bolted joints were constructed with one bolt and two metal side plates. Two nails and two metal side plates were used for the nailed joint. For precut joints, no clear effect of MC was recognized on maximum moment and initial stiffness. The maximum strength of mechanical joints assembled with kiln-dried wood was changed by the degree of drying. Stiffness of the joints assembled with kiln-dried specimens was larger than that of the joints assembled with green specimens.Part of this study was presented at the 7th International IUFRO Wood Drying Conference, Tsukuba, July 2001  相似文献   

11.
Prediction of yield load has nowadays been accepted as the basis for the limit state method of the design. Currently, there are many methods to predict the yield load of timber joints. These methods, i.e Foschi, Johansen, Smith and US 5% nail diameter offset, are reviewed in-depth in this paper. In this study, the authors presented a new approach which, hopefully, is simpler than the existing methods. The paper outlines the works carried out to arrive at the formula. About 300 Malaysian timber nailed joints were fabricated and tested to obtain the relationship between yield load and maximum load and to propose a new method to predict the yield load of a nailed joint. There seems to be a direct relationship between the yield load and the maximum load. From this relationship, a new formula, which depends only on nail diameter and specific gravity, was established.  相似文献   

12.
An experimental study on combined steel-to-timber joints with nails and bolts is conducted in this study. Principal results are as follows: The initial stiffness and effective allowable resistance of combined joints depend obviously on clearances in predrilled bolt-holes. The combined joints with nails and bolts have high potential of energy capacity to resist strong earthquake forces. There are upper limits of clearances in predrilled bolt-holes that allow advantages of considering the synthetic resistance of combined joints in practical structural design. Combining the joint components with appropriate design will give higher performance against strong earthquakes increasing the safety margin and energy capacity until the failure. The combined joints should be designed under the restrictions of particular specifications in closed design systems because the advantages of combining the joint components are influenced obviously by various actual conditions, which are too difficult to consider in detail in open design systems.  相似文献   

13.
Monotonic and reversed cyclic loading tests were conducted on dowel-type timber joints with varying degrees of wood decay due to Fomitopsis palustris (Berk. et Curt.), a brown rot fungus, and the effect of decay on various shear performances of dowel-type joints was investigated. For joints affected by the brown rot fungus, the initial stiffness, yield load, and maximum load of dowel-type joints were significantly decreased, even with a small mass loss of wood. The reductions in shear performance were the largest for initial stiffness, followed by yield load and maximum load, in that order. For a 1% reduction of the yield load, initial stiffness and maximum load showed reductions of 1.15% and 0.77%, respectively. When dowel-type joints that had been exposed to the brown rot fungus were subjected to reversed cyclic loading, the gap between the dowel and the lead hole of the wood was increased and equivalent viscous damping was decreased. These results indicate that decay around the dowel lead hole especially affects the load-displacement behavior at small displacement level, and dowel-type joints under cyclic loading have very low resistance to forces acting on the wooden structure. Part of this report was presented at the 5th Symposium on Timber Bridges of the Japan Society of Civil Engineers, Tokyo, July 2006; the 56th Annual Meeting of the Japan Wood Research Society, Akita, August 2006; and the Annual Meeting of the Architectural Institute of Japan, Fukuoka, August 2007  相似文献   

14.
对我国东北地区落叶松在木结构中钉连接施工技术进行的试验研究表明,用兴安落叶松进行钉连接时,预钻孔直径应是钉直径的85%左右,预钻孔深度应该超过钉入深度;用于端部钉连接的钉不易太粗,可通过具体试验确定或采取相应技术措施,保证连接性能。  相似文献   

15.
Under varying climate conditions, cracks are commonly observed in bolted joints, owing to the shrinkage of wood and confinement from slotted-in steel plates and bolts. A three-dimensional finite element model was developed to investigate the mechanical behavior of bolted glulam joints with initial cracks. Wood foundation was prescribed in the model to simulate the local crushing behavior of wood surrounding the bolts. The behavior of wood in compression and the foundation were defined as transversely isotropic plastic in the software package ANSYS. Cohesive zone model was applied in the numerical analysis to consider the propagation of initial cracks and brittle failure of wood in the bolted joints under tension load. The numerical model was validated by the experiments conducted on full-scale specimens and it is indicated that the numerical model has good ability in predicting the failure modes and capacity of tension joints with local cracks. To further investigate the influence of crack number, length and locations, a parametric study was conducted with the verified model. Moreover, to study the effects of cracks on the behavior of bolted joints with different failure modes, another bolted joint including bolts with different strength grades and diameters was designed and analyzed in the parametric study, which was expected to have bolt yielding failure mode. It was found that the initial cracks can decrease the capacity and initial stiffness of tension joints by up to 16.5 and 34.8%, respectively.  相似文献   

16.
A quasi-non-linear fracture mechanics model based on beam on elastic foundation theory is applied for analysis of dowel joints with a single dowel loaded perpendicular to grain. The properties of the elastic foundation are chosen so that the perpendicular-to-grain tensile strength and fracture energy properties of the wood are correctly represented. It is shown that this particular choice of foundation stiffness makes a conventional maximum stress failure criterion lead to the same solution as the compliance method of fracture mechanics. Results of linear elastic fracture mechanics are obtained as a special case by assuming an infinitely large value of the foundation stiffness. Results of tests on so-called plate joints are compared with theoretical predictions, showing good agreement for variations in initial crack length as well as edge distance.  相似文献   

17.
The purpose of the study was to determine the effect of joints on the mid-span load capacity of bookshelves made from laminated particleboard. Twenty types of joints were selected based on their popularity in the cabinet-making industry. Results showed that highest mid-span load capacities were obtained with glued groove joints that included glued wooden dowels. Overall, highest mid-span load capacities were obtained with fixed shelf-joint constructions, whereas lower capacities were obtained with adjustable constructions. Based on its high-load capacity and ease of construction, the spline joint appears best-suited for use by most craftsmen. Statistical lower tolerance limits were used to take capacity variability into account for design purposes. The 75% confidence|75% proportion limits for the glued wood spline and glued fiberboard spline joints were 94% and 93% of average, respectively.  相似文献   

18.
In this study, dynamic tests of nailed plywood-timber joints are conducted under a band-limited white-noise wave using a uniaxial hydraulic shaking table. The principal results are as follows: dynamic responses of nailed plywood-timber joints under a band-limited white-noise wave are reasonably related to the static load-slip relationships and the dynamic responses under harmonic waves of them. When nailed plywood-timber joints are shaken under a composite wave of wide frequency range, they resonate transitionally with one of the frequency components one after another decreasing their equivalent resonant frequencies along their static load-slip curves. Nailed plywood-timber joints are in danger of ultimate failures even though the input maximum accelerations do not exceed their damage limits, if they are shaken for long times with or without intermittences. In this case, nailed plywood-timber joints are prone to fail in low-cyclic bending fatigue failure of nails. Nailed plywood-timber joints, on the other hand, are prone to fail in typical static failure modes when they are shaken under strong input maximum accelerations equivalent to their ultimate limits.  相似文献   

19.
Previous experimental studies reported that bolt pretensioning greatly increases the initial stiffness and load-carrying capacity of bolted joints. It is also a matter of great importance to structural designers to understand the effect of pretension on the load-carrying capacities of bolted joints, and this study presents an extended yield model that considers the fastener’s pretension force. In the extended yield model, the load-carrying capacity was defined as the load at a slip of 15 mm. The ultimate fastener bending angle at the yielded cross section equivalent to this joint slip, which was affected by the fastener’s axial force, was iteratively evaluated in numerical analyses. The introduction of bolt pretensioning largely increased the joint slip resistance at initial loading, but it decreased the ultimate fastener bending angle. This decrease of fastener bending angle resulted in a relatively low stiffness hardening (or secondary stiffness), which is caused by secondary axial forces associated with embedment of steel plates into the wood member. Prediction was verified by the tests of 36 steel-to-timber joints under three different pretension forces and two loading directions relative to the grain. Some of the observed load-carrying capacities of the joints, particularly in loading perpendicular to the grain, however, were not as high as those expected by the numerical analyses considering the given pretension forces.  相似文献   

20.
The joint-slip in nailed joints in the form of standard block shear specimens was measured with the aid of a small apparatus which can be fixed directly to the specimen.

The method of measuring joint-slip of nailed joints as described in this paper yielded very accurate and satisfactory results. The load-displacement curves obtained are very typical for nailed joints.

The deformation registered by the Instron testing machine did not represent the true joint-slip, but rather the total deformation which took place in the wood as well as the machine parts.  相似文献   