首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Renal length, height, width, resistive index (RI), size of cortex, and medulla were determined by renal ultrasonography in 50 healthy Korean domestic short-hair cats. In the sagittal plane, the renal length was 3.83 ± 0.51 cm (mean ± SD) in the left kidney and 3.96 ± 0.48 cm in the right kidney, whereas the renal height was 2.42 ± 0.27 cm in the left kidney and 2.36 ± 0.28 cm in the right kidney. In the transverse plane, the renal height was 2.42 ± 0.28 cm in the left kidney and 2.38 ± 0.27 cm in the right kidney, whereas the renal width was: 2.65 ± 0.35 cm in the left kidney and 2.63 ± 0.31 cm in the right kidney. In the dorsal plane, the renal length was 3.84 ± 0.53 cm in the left kidney and 3.97 ± 0.54 cm in the right kidney, whereas the renal width was 2.65 ± 0.34 cm in the left kidney and 2.66 ± 0.33 cm in the right kidney. There were no significant differences (p > 0.05) among the same structure sizes measured in different planes. In the sagittal plane, the size of the renal cortex was 0.47 ± 0.08 cm in the left kidney and 0.47 ± 0.08 cm in the right kidney, whereas of the size of the renal medulla was 0.55 ± 0.30 cm in the left kidney and 0.50 ± 0.07 cm in the right kidney. RI evaluated by pulsed wave Doppler sonography was 0.52 ± 0.05 in the left kidney and 0.55 ± 0.05 in the right kidney. The actual renal dimensions determined by gross examination were not statistically different from those determined by ultrasonography. Furthermore the renal dimensions and RI were statistically correlated to the body weight of cats.  相似文献   

2.
The aims of this study were to establish a normal reference range (mean ± 2 SD) and assess reliability of renal dimensions obtained using transabdominal ultrasonography in Thoroughbred horses (n = 7). A minimum of three ultrasonographic cineloops were obtained from each intercostal space and the left paralumbar fossa by two observers daily for three consecutive days. Renal length, width, and thickness and cortex, medulla, and pelvic dimensions were obtained. Measurements were undertaken by both observers, who were unaware of prior measurements, to assess reproducibility and measured on three separate occasions to evaluate short-term measurement repeatability. Measurements from images obtained by both operators were compared to evaluate image repeatability. The left kidney was consistently identified in the left 15th-17th intercostal space and the paralumbar fossa with maximal length in the 16th intercostal space (12.7 ± 2.0 cm) and maximal width in the paralumbar fossa (7.9 ± 1.1 cm). The right kidney was consistently identified in the right 15th-17th intercostal space with maximal length and maximal width in the 15th intercostal space (16.0 ± 0.7 cm and 7.9 ± 1.0 cm). Reproducibility, image repeatability, measurement repeatability were good to excellent, although were less good for the smaller structures. There were no differences in renal dimensions between horses. Overall renal ultrasonography was reliable and a normal reference range for Thoroughbred horses was established. Renal dimensions vary between rib spaces. As repeatability and reproducibility were excellent for renal length and width, it may be prudent to use those measurements in rib spaces where parameters were maximal.  相似文献   

3.
Multidetector row computed tomography (MDCT) provides anatomical information about the kidney and other internal organs. Presently, the suitability of 64-channel MDCT to assess the kidney of healthy micropigs was evaluated. Morphological evaluations of the kidney and the major renal vessels of six healthy micropigs were carried out using MDCT, recording kidney volume and the diameter and length of renal arteries and veins. The mean diameters and lengths of the renal artery were 0.44 ± 0.05 and 4.51 ± 0.55 cm on the right side and 0.46 ± 0.06 and 3.36 ± 0.27 cm on the left side, respectively. The mean diameters and lengths of the renal vein were 1.44 ± 0.52 and 4.22 ± 1.29 cm on the right side and 1.38 ± 0.17 and 5.15 ± 0.87 cm on the left side, respectively. The mean volume of the right kidney was 79.3 ± 14.5 mL and of the left kidney was 78.0 ± 13.9 mL. The data presented in this study suggest that the MDCT offers a noninvasive, rapid, and accurate method for the evaluation of the renal anatomy in living kidney donors. It also provides sufficient information about extra-renal anatomy important for donor surgery and determination of organ suitability.  相似文献   

4.
BackgroundChinchillas, being small mammals, are subject to many of the urinary disorders that affect other companion animals. In cats and dogs, relationships between renal length and the presence of renal pathology have been well documented through the use of diagnostic imaging. Radiography and computed tomography (CT) are two commonly utilized diagnostic imaging modalities for assessing renal pathology. Presently, there are no published data on chinchilla kidney size and appearance using radiography or CT. This study aimed to determine healthy adult chinchilla renal size and correlate renal size to L2 body length and aortic diameter by use of radiography and CT.MethodsTwenty-eight healthy adult chinchillas with no clinical evidence of renal disease were placed under sedation for acquisition of radiographs and CT imaging. Both kidneys were measured on the radiographic views (right lateral, left lateral and ventrodorsal), when identifiable. Renal length, L2 body length and abdominal aortic diameter were measured on CT multiplanar reformatted images in specified planes and windows.ResultsIn 25% (7/28) of chinchillas, the renal length of either kidney could not be obtained on any of the three radiographic views due to superimposition of fluid and ingesta within the alimentary tract. Both the right and left kidney were identified on CT images in 100% of chinchillas (28/28). The left renal and right renal 95% confidence intervals from the dorsal plane CT images were 2.26 – 2.33 cm and 2.31 – 2.39 cm, respectively. No correlation was found between kidney length, L2 body length and diameter of the abdominal aorta on CT images.ConclusionsBased on dorsal plane CT imaging, normal chinchilla renal length is proposed to be between 2.25–2.4 cm.Clinical RelevanceRadiographic evaluation of chinchilla renal length is greatly limited due to their large fluid- and ingesta-filled colon and cecum, as is typical of animals that are hindgut fermenters. Through establishment of a normal CT reference interval for renal length and the ever-increasing clinical utility of CT, clinicians can better evaluate chinchilla renal length and identify alterations that may indicate pathologic processes.  相似文献   

5.
The aims of this study were to determine the total volume of the horse kidney and volume fractions of its functional subcomponents (cortex, medulla, renal pelvis) using stereological methods and investigate any possible difference in the functional subcomponents of the right and left kidneys that may arise from differences in shape. The study was carried out on the kidneys of 5 horses of different breed and sex. The weight of the kidneys was measured by a digital scale, and kidney volume was calculated by Archimedes' principle. Total kidney volume and volume fractions of subcomponents of the right and left kidneys were estimated by the Cavalieri's principle. The weights of the right and left kidneys were 550 ± 25 g and 585 ± 23 g, respectively. The volumes of the right and left kidneys estimated using the Cavalieri method were 542 ± 46 ml and 581 ± 29 ml. The relative organ weight of the kidneys was calculated as 1:330. The densities of the right and left kidneys were determined to be 1.01 and 1.00, respectively. The mean volume fractions of the cortex, medulla and renal pelvis were determined as 55.6, 42.7 and 1.7 in both kidneys. No statistically significant difference existed between morphometric data pertaining to the right and left kidneys (P > 0.05). To determine precisely whether differences in shape cause any difference in the functional subcomponents of the right and left kidneys requires further investigation of differences in the number of microscopically functional unit of the kidney such as renal glomeruli and nephrons.  相似文献   

6.
Renal length and width dimensions were determined from survey radiography and excretory urography in 28 cats of various sex and reproductive status. Renal dimensions were expressed as a ratio to the length of the second lumbar vertebra. Renal dimensions were not significantly different when males were compared to females. However, significant differences in renal dimensions between intact and neutered cats were identified. Renal length ratios for neutered cats were: left kidney 2.22 +/- 0.14 (mean +/- standard deviation), right kidney 2.29 +/- 0.14. In intact cats, renal length ratios were: left kidney 2.60 +/- 0.19, right kidney 2.65 +/- 0.24. The mean renal length ratios for neutered cats was smaller than previously reported normal values. Thus, reproductive status should be considered when evaluating feline kidneys for alterations in size. Based on this study, normal feline renal length ratios range from 1.9 to 2.6 for neutered cats and 2.1 to 3.2 for intact cats.  相似文献   

7.
A reliable method for obtaining renal ultrasonographic measurements in the horse is important for diagnosis and monitoring of clinical renal disease. The aims of this prospective study were to develop and validate a novel translumbar ultrasound technique for measuring renal dimensions in horses. Six Thoroughbred or Thoroughbred part bred horses were recruited. All horses were scheduled for euthanasia due to reasons unrelated to the kidneys. Two observers recorded renal length, width, and depth; and dimensions of the cortex, medulla, pyramids, and pelvis for both kidneys in each horse using novel translumbar and conventional transabdominal ultrasound methods. The same measurements were recorded from post‐mortem renal specimens. Both kidneys were consistently identified by both methods in the 15–17th intercostal spaces and paralumbar fossa. Using the translumbar technique, maximal dimensions were obtained for the left kidney in the 16th intercostal space (length 16.2 ± 2.0 cm, width 11.8 ± 0.5 cm, depth 6.4 ± 0.9 cm) and for the right kidney in the 15th intercostal space (length 16.1 ± 1.2 cm, width 13.4 ± 1.2 cm, depth 6.7 ± 0.7 cm). Renal dimensions obtained by transabdominal and translumbar projections did not differ (P > 0.05). Good correlations were found between overall renal dimensions and post‐mortem measurements for both ultrasound techniques (r2 > 0.8), but were better for the translumbar method (mean r2 = 0.92 cf. 0.88). Good‐to‐excellent reliability was found for all translumbar ultrasound measurements except for the renal cortex. Reproducibility was better for the larger (overall length, width, and depth) than the smaller (cortex, medulla, and pyramids) structures. Findings indicated that translumbar ultrasonography is a valid method for measuring renal dimensions in horses.  相似文献   

8.
The literature on plain film evaluation of the canine liver is reviewed and the problems associated with radiographic hepatometry in this species and in man are outlined. Methods used to determine liver size in man are briefly described. Liver measurements obtained from lateral recumbent radiographs of 20 German Shepherd Dogs were examined statistically. The ratio of a measurement of liver length to second lumbar vertebra body length was found to be of statistical value, as was the relative position of the junction separating left medial, right medial and quadrate lobes from a further part of the right medial and left lateral lobes. The extrapolation of these results to other breeds is discussed.  相似文献   

9.
We determined the position, dimensions, and structure of the kidneys, ureters, bladder, and urethra in 20 healthy, adult rams by use of ultrasonography. The findings were compared with those of seven rams with obstructive urolithiasis, thus establishing criteria for the diagnosis of urolithiasis via ultrasonography. A 5.0 MHz convex transducer was placed over the right paralumbar fossa to examine the kidneys, and a 5.0 MHz linear rectal transducer was used to examine the bladder and urethra transrectally. All examinations were performed on standing rams. The left kidney had a length of 8.4 ± 0.3 cm (mean ± SD), a width of 4.7 ± 0.3 cm, and a depth of 4.4 ± 0.3 cm. The diameter of the renal sinus of the left kidney was 1.5 ± 0.2 cm. The circumference of the medullary pyramids measured 2.8 ± 0.3 cm. Similar ultrasonographic measurements were obtained for the right kidney. The mean diameter of the bladder of 12 rams was 7.5 ± 2.8 cm. The diameter of the bladder could not be determined in the remaining eight rams because it was greater than 10 cm and therefore beyond the penetration depth of the scanner. The only part of the urethra which could be visualized ultrasonographically was the internal urethral orifice. It had a diameter of 0.2 ± 0.1 cm.

Ultrasonographic examination of seven rams with obstructive urolithiasis revealed a markedly dilated urethra and urinary bladder. Due to severe cystitis, the contents of the urinary bladder appeared as multiple, tiny, uniformly distributed echoes. The renal pelvis and medullary pyramids of both kidneys were dilated in four rams. In two rams, uroperitoneum and accumulation of urine in the abdomen were diagnosed via ultrasonography. In one ram this was due to a ruptured ureter and in one to a ruptured bladder. The results of this study indicate that ultrasonography is a useful aid in the diagnosis of obstructive urolithiasis.

  相似文献   

10.
A 4-day-old alpaca cria presented for inappetence that responded to symptomatic treatment. The cria re-presented with acute signs of inappetence and azotaemia. The azotaemia persisted despite intravenous fluid therapy. There was no right kidney on ultrasound and there appeared to be perirenal oedema around the left kidney. A diagnosis of right renal agenesis and acute renal failure of the left kidney was made. The cria failed to improve and was euthanased. Necropsy examination confirmed right renal agenesis and agenesis of the right ureter and right renal artery. A section of left kidney submitted for histological examination revealed diffuse, acute, marked tubular degeneration and nephrosis. The cause of the renal failure in the left kidney was not determined.  相似文献   

11.
In humans, crossed renal ectopia is a rare, usually asymptomatic, congenital malpositioning of the kidneys, involving wandering of one or both embryonic kidneys across the midline and usually fusion with its contralateral partner. This is the first report of crossed renal ectopia in the cat. A 7-year-old, neutered male cat was presented with polyuria, polydipsia, and a palpable abdominal mass. Diagnostic investigations, including clinical pathology, survey and contrast radiography, and ultrasonography, confirmed the presence of an ectopic left kidney fused with an orthotopic right kidney, with concurrent renal failure and hypertension. Many features of crossed renal ectopia in this cat are similar to those described in humans, however the vascular supply, the presence of renal failure, and the axial rotation of the fused kidney are atypical.  相似文献   

12.
Cystic renal disease is rare in dogs and although infected renal cysts have been reported in humans, no report could be found in dogs. A 58 kg, 5-year-old, castrated, male Boerboel presented with weight loss, pyrexia, lethargy and vomiting, 20 months after an incident of haematuria was reported. The initial ultrasonographic diagnosis was bilateral multiple renal cysts of unknown aetiology. The cysts had significantly increased in size over the 20-month period and some contained echogenic specks which could be related to infection, normal cellular debris or haemorrhage. In both kidneys the renal contours were distorted (the left more than the right). The abnormal shape of the left kidney was largely due to multiple cysts and a large crescent-shaped septate mass on the cranial pole of the kidney. Aspirates of the septate mass were performed (left kidney) and the cytology and culture were indicative of an abscess. It is suggested that the previous incident of haematuria provided a portal of entry for bacteria into the cysts resulting in renal cortical abscess formation.  相似文献   

13.
There are numerous publications about feline renal imaging information; however, none have established reference values for kidney size using computed tomography (CT). This study aimed to determine renal size and shape as well as the morphology of renal‐related structures in clinically normal cats (Felis catus) that underwent CT. Twenty‐seven healthy cats underwent pre‐ and post‐iodinated contrast‐enhanced CT. Most cat (59%) kidneys were located at the same level. The average pre‐contrast dimensions of the left kidney included a width of 2.46 ± 0.28 cm, a length of 3.52 ± 0.44 cm and a height 2.19 ± 0.31 cm, whereas those of the right kidneys were 2.45 ± 0.27 cm, 3.54 ± 0.46 cm and 2.05 ± 0.23 cm, respectively. After contrast enhancement, kidneys were slightly enlarged though not significantly. Additionally, renal length (LK or RK) was compared with second lumbar vertebra (L2) length and abdominal aorta diameter (AO). AO was significantly larger in male cats whereas L2 length appeared longer in male cats, but was not statistically different from the female cats. The LK/L2 and RK/L2 ratios were 2.29 ± 0.23 and 2.36 ± 0.20, respectively, and the LK/AO and RK/AO were 11.72 ± 1.37 and 12.05 ± 1.47, respectively. Renal vessels were examined. The renal vein was obviously larger than the renal artery, and paired renal veins were observed periodically. This study provides CT information about the feline kidney, which may help to establish reference values and information regarding renal structure prior to surgery in practice.  相似文献   

14.
A biopsy procedure was developed to provide serial kidney samples from standing steers. Ten clinically normal steers were given intramuscular injections of gentamicin sulfate, 4 mg/kg body weight. Renal biopsy was performed at 5 separate times. After feed was withheld for 24 h, laparoscopic surgery was performed in standing stocks. Acepromazine, xylazine, and butorphanol were used for sedation and analgesia, and 2% lidocaine was used for local anesthesia. Two incisions approximately 2 cm long were made in the paralumbar fossa to allow for trocar introduction. The abdomen was insufflated with CO2 and, with endoscopic guidance, a biopsy forceps used to remove a kidney sample 2 to 3 mm in diameter, by either a left or a right abdominal approach. Each operation was recorded on videotape, and images were also captured with a digital medical device system. Respiration, heart rate, temperature, appetite, attitude, and postural positions were evaluated at 12, 24, 48, and 72 h after surgery. The 51 laparoscopic procedures provided 48 renal samples (approximately 100 mg each). The 1st and 2nd samples were from the right kidney, and the 3rd sample was from either the left or the right kidney; the 4th and 5th samples were from the left kidney. Adhesions made an approach from the right side difficult for the 3rd sample. No clinical changes were observed in 9 steers after the procedure. One steer died after the 3rd procedure owing to hemorrhage.  相似文献   

15.
The size of the borders of the omental veil as well as its relation to body length and weight, were studied in 71 mongrel dogs. The average size of the omental veil in adult dogs was: caudal margin 17cm, cranial margin 16 cm, right margin 10 cm and left margin 7 cm. A very significant relation (P < 0.001) was found between the dimensions of each border and the body length and weight.  相似文献   

16.
运用管道铸型技术以及扫描电镜技术对双峰驼肾动脉血管进行了系统观察.结果显示,双峰驼肾动脉在入肾门前约4~8 cm处分为背干和腹干,入肾后在肾窦内相继形成肾段动脉.左右两肾段动脉的分支分布各有特点,各段动脉分支延伸至肾的皮髓交界处,形成弓形动脉;弓形动脉是叶间动脉的延续,并不与肾表面相平行;肾血管球以及出、入球微动脉因分布区域的不同,形态结构也不尽一致.表明,双峰驼肾各段动脉分布的规律性强,段动脉分支之间没有吻合支存在;肾各部位的血管球随分布区域的不同,其形态结构也呈现一定的变化.  相似文献   

17.
OBJECTIVE: To compare glomerular filtration rate (GFR) as estimated from Patlak plot analysis by use of single-slice computed tomography (CT) with that obtained from clearance of plasma inulin in pigs. ANIMALS: 8 healthy anesthetized juvenile pigs. PROCEDURES: All pigs underwent precontrast, whole-kidney, helical CT; postcontrast single-slice dynamic CT; and postcontrast, whole-kidney CT for volume determination. On dynamic images, corrected Hounsfield unit values were determined for each kidney and the aorta. A Patlak plot for each kidney was generated, and plasma clearance per unit volume was multiplied by renal volume to obtain whole-animal contrast clearance. Mean GFR determined via inulin clearance (Inu-GFR) was measured from each kidney and correlated to mean GFR determined via CT (CT-GFR) for the left kidney, right kidney, and both kidneys by use of linear regression and Bland-Altman analyses. RESULTS: CT-GFR results from 7 pigs were valid. Total and right kidney Inu-GFR were correlated with total and right kidney CT-GFR (total, R(2) = 0.85; right kidney, R(2) = 0.86). However, left kidney CT-GFR was poorly correlated with left kidney Inu-GFR (R(2) = 0.47). Bland-Altman analysis revealed no significant bias between Inu-GFR and CT-GFR for the left kidney, right kidney, or both kidneys. CONCLUSIONS AND CLINICAL RELEVANCE: CT-GFR as determined by use of a single-slice acquisition technique, low-dose of iohexol, and Patlak plot analysis correlated without bias with Inu-GFR for the right kidney and both kidneys (combined). This technique has promise as an accurate CT-GFR method that can be combined with renal morphologic evaluation.  相似文献   

18.
Helical computed tomography angiography was used to evaluate the renal vascular anatomy of potential feline renal donors. One hundred and fourteen computed tomography angiograms were reviewed. The vessels were characterized as single without bifurcation, single with bifurcation, double, or triple. Multiplicity was most commonly seen for the right renal vein (45/114 vs. 3/114 multiple left renal veins, 0/114 multiple right renal arteries, and 8/114 multiple left renal arteries). The right kidney was 13.3 times more likely than the left to have multiple renal veins. Additional vascular variants included double caudal vena cava and an accessory renal artery. For the left kidney, surgery and computed tomography angiography findings were in agreement in 92% of 74 cats. For the right kidney, surgery and computed tomography angiography findings were in agreement in 6/6 cats. Our findings of renal vascular anatomy variations in cats were similar to previous reports in humans. Identifying and recognizing the pattern of distribution of these vessels is important when performing renal transplantation.  相似文献   

19.
为建立血吸虫虫卵计数的可准确量化和易于操控的小鼠肝脏取样方法,用日本血吸虫人工感染BALB/c系小鼠42 d后,将肝脏分成左叶、中央叶、右叶,分别进行日本血吸虫虫卵计数。结果显示,感染日本血吸虫42 d的BALB/c小鼠肝脏的平均重量为(2.23±0.26)g。左叶、中央叶、右叶和全肝的每克肝脏含卵数(EPG)分别为49.80×103±26.70×103,59.03×103±29.04×103、36.55×103±17.77×103和47.78×103±23.64×103。各肝叶之间差异有统计学意义(P〈0.05)。可见,血吸虫虫卵在肝脏各叶中的分布是不均匀的,以肝中央叶为最多,肝右叶最少。肝脏EPG与各肝叶中EPG符合线性关系,每对配对成虫对肝脏EGP的贡献从3.67×103到6.5×103个虫卵不等。  相似文献   

20.
The left and right kidneys, ureters, urinary bladder and urethra of 29 female clinically healthy Saanen goats were examined via transcutaneous and transrectal ultrasonography. In order to establish reference values the examinations were performed using a 5.0 MHz linear transducer to scan the right caudal costal part of the abdominal wall, right and left dorsal flanks and right and left inguinal regions of standing goats. A 5.0 MHz intracavity probe was used for transrectal ultrasonographic examination of the urinary bladder and urethra. The kidneys were examined in longitudinal and cross section and assessed subjectively. They could usually be seen from the 12th intercostal space on the right side and dorsal right flank. The right kidney was 8.0 ± 0.67 cm long and the left was 8.4 ± 0.64 cm long. The ureters could not be visualized in any of the goats. The length of the urinary bladder was 5.1 ± 1.38 cm, and its largest cross-sectional diameter was 2.6 ± 1.01 cm. The urethra was seen in 23 goats and appeared as echogenic lines with no visible lumen. The transition from the neck of the bladder to the internal urethral orifice extended beyond the brim of the pelvis in only one goat.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号