首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 225 毫秒
1.
Three kinds of locally available plastic biofilter media with different configurations (plastic rolls, PVC pipes and scrub pads) were evaluated for their efficiency in organic waste removal from the effluents of an intensive recirculating tilapia culture system. A set of three types of solid-removing filters consisting of screened sedimentation; upflow sand as well as plastic bead filtration accomplished the mechanical filtration. Values of critical metabolic wastes like total ammonia nitrogen (TAN) (0.92 ppm) and nitrite-nitrogen (NO2-N) (0.22 ppm) were found to be well within the acceptable limits, while other water quality parameters in the culture water were also maintained within the normal range by the filtration system. Removal rates of 3.46 g TAN/m3 per day and 0.77 g NO2-N/m3 per day, as well as TAN and NO2-N removal efficiencies of 29.37 and 27.3% respectively, were established to be the best for the plastic-roll biofilter medium as compared to PVC-pipe and scrub-pad media. Percent removal of TAN and NO2-N per pass of the biofilter (25.49 and 26.3% respectively) and the specific TAN and NO2-N removal rates (43 and 9.6 mg/m2 per day) of plastic rolls were also found to be superior to the other two biofilter media. Pieces of PVC pipes as biofilter medium is recommended to be used in the biofilters in view of their cheaper cost.  相似文献   

2.
Application of microbead biological filters   总被引:1,自引:0,他引:1  
The application of floating microbead filters to aquaculture is reviewed and discussed. The microbead filter is distinctly different from the more commonly used floating bead filters that are used today. Conventional bead filters work in pressured vessels and use a media that is only slightly buoyant. The required mass of beads for the volume required make the media a relatively expensive component of a floating bead filter in contrast to sand or microbead media that is much less expensive on a per volume basis. Microbead filters use polystyrene beads (microbead) that are 1–3 mm in diameter (floating bead filters use media approximately 3 mm in diameter also). Microbead have an overall bulk density of 16 kg/m3 and a specific surface area of 3936 m2/m3 (for 1 mm beads). This material can be obtained commercially in bulk for roughly US$ 4 kg−1 of material. Biological filters that use microbeads for their nitrifying substrate can be thought of as a trickling bio-filter in terms of how the flow distribution and collection mechanics are designed and operated. For design purposes, microbead filters can be assumed to nitrify approximately 1.2 kg of TAN/m3 of media per day for warm water systems with influent ammonia–nitrogen levels from 2 to 3 mg/l. For cool water applications, rates should be assumed to be 50% of warm water rates or use rates similar to those used for fluidized sand beds. Designs and results in several applications are presented. Microbead filters have been used successfully by several commercial growers after being first introduced in the mid 1990s. Effects of capitalization for equipment and buildings upon production costs is discussed and presented in graphical form.  相似文献   

3.
A 2.83 m3 prototype paddle-washed bead filter for combined solids capture and biological filtration was successfully operated in a commercial recirculating alligator (Alligator mississippiensis) facility. The bead filter was originally designed and operated as a downflow filter but due to operational and water quality problems, it was reconfigured to operate in an upflow mode. Water quality conditions and filter performance improved dramatically, with the upflow bead filter capable of handling the equivalent loading of 10.3 kg m−3 beads per day of 40% protein feed, despite oxygen limitations and hydraulic problems associated with the retrofitted alligator system.  相似文献   

4.
This paper describes the performance characteristics of an industrial-scale air-driven rotating biological contactor (RBC) installed in a recirculating aquaculture system (RAS) rearing tilapia at 28 °C. This three-staged RBC system was configured with stages 1 and 2 possessing approximately the same total surface area and stage 3 having approximately 25% smaller. The total surface area provided by the RBC equaled 13,380 m2. Ammonia removal efficiency averaged 31.5% per pass for all systems examined, which equated to an average (± standard deviation) total ammonia nitrogen (TAN) areal removal rate of 0.43 ± 0.16 g/m2/day. First-order ammonia removal rate (K1) constants for stages 1–3 were 2.4, 1.5, and 3.0 h−1, respectively. The nitrite first-order rate constants (K2) were higher, averaging 16.2 h−1 for stage 1, 7.7 h−1 for stage 2, and 9.0 h−1 stage 3. Dissolved organic carbon (DOC) levels decreased an averaged 6.6% per pass across the RBC. Concurrently, increasing influent DOC concentrations decreased ammonia removal efficiency. With respect to dissolved gas conditioning, the RBC system reduced carbon dioxide concentrations approximately 39% as the water flowed through the vessel. The cumulative feed burden – describes the mass of food delivered to the system per unit volume of freshwater added to the system daily – ranged between 5.5 and 7.3 kg feed/m3 of freshwater; however, there was no detectable relationship between the feed loading rate and ammonia oxidation performance.  相似文献   

5.
The purpose of this study was to develop a mathematical model to assist in the determination of design numbers for color destruction by ozone as a function of feed rate. A mass balance model was developed that takes into account methods of introduction and removal of color, including removal by ozone. Because direct measurement of color mass or concentration is difficult, a representative unit was developed during this study called the color mass equivalent (CME). The CME represents a direct measurement of absorbance at 436 nm, which is a unitless measurement, multiplied by the system volume. The CME is directly proportional to the true concentration of color causing compounds at that wavelength. Once the model was developed, two studies were run to test the model. A 1,500-L recirculating fish system was set up with a 57-L bead filter and six 1-L fluidized sand beds. Approximately 45 kg of channel catfish Ictalurus puncfatus were placed in the system and fed 0.25 kg of 32% protein feed per day (0.55% body wt.). Once the system reached stable conditions, the system was flushed with clean water and samples were taken to estimate the accumulation rate of color in the system. After 5 wk, an ozone unit was activated and samples were taken to determine the destruction rate for color. Once an accumulation rate had been determined, a second study was performed to corroborate this value. The same ozone unit was installed on a 5,000-L recirculating fish system being fed 0.49 kg per day with a 171-L bead filter. Samples were taken to determine the destruction rate for color. The accumulation rate for color was 12.6 CME/kg feed and the destruction rates were 1.7 CME/g O3 in the first study and 0.82 CMWg O3 in the second study. This calculates to a range of 7 to 15 g O3/kg feed to remove the color produced by the feed.  相似文献   

6.
A simple indoor recirculating system for production of juvenile sea cucumber (Apostichopus japonicus) was operated on a commercial scale for 90 days during winter. The system consists of three 70 m3 sea cucumber rearing tanks and one biofilter tank where macroalgae (Ulva pertusa) was used as a biofilter in order to reduce water requirements. Effluent from the sea cucumber tanks drained into the macroalgae biofilter tank and were then returned to the sea cucumber tanks by a discontinuous-flow recirculation system. Survival and growth rates in the sea cucumber culture tanks were similar to those in the control tank (with one water exchange per day). The survival rate averaged about 87%. The average body weight increased from 3.5 ± 0.3 g to 8.1 ± 0.8 g and total sea cucumber biomass production over the experimental period was 745 g m−2 after initial stocking densities of 375 g m−2. The growth rate of U. pertusa was 3.3% day−1. U. pertusa was efficient in removing toxic ammonia and in maintaining the water quality within acceptable levels for sea cucumber culture; there were only small daily variations of temperature, pH and DO. The U. pertusa tank removed 68% of the TAN (total ammonia-nitrogen) and 26% of the orthophosphate from the sea cucumber culture effluent; the macroalgae biofilter removed ammonia at an average rate of 0.459 g N m−2 day−1. It would be efficient to use the U. pertusa biofilter in a recirculating system for production of A. japonicus juveniles in winter.  相似文献   

7.
Three different commercially available structural plastic media were evaluated in triplicate in moving bed biofilters under low salinity (11–12 ppt) warm water culture conditions and two different feed loading rates. The culture system consisted of nine separate modules that include a double drain fish culture tank paired to a moving bed biofilter. The biofilters were filled with 0.11 m3 of one of three different types of floating plastic structured media. The three types of media evaluated were K1 kaldnes media, MB3 media, and AMB media. Volumetric total ammonia nitrogen (TAN) removal rates (g TAN removed/m3 media-day), TAN removal efficiency, and biofilm kinetic constants, Ki (h−1) were determined for the three media types at two different daily feed load rates of 3.5 and 8.2 kg feed/m3 media. The feed provided was a 4.8 mm slow sinking marine grower diet pellet (45% protein, 17% fat). Average (±standard deviation, SD) volumetric TAN removal rates (VTR) at the lower feed load for the three media types were 92.2 ± 26.3, 86.1 ± 27.5, and 82.5 ± 25.9 for the MB3, AMB, and K1 kaldnes media, respectively. At the higher feed load the average VTR for the three media types was 186.4 ± 53.7, 172.9 ± 47.8, and 139.9 ± 38.9 for the MB3, AMB, and K1 kaldnes media, respectively. Influent TAN concentrations varied by the feed load rate and ranged from 0.55 to 0.93 mg/L and 0.83 to 1.87 mg/L for the low and higher feed loads, respectively. The percent TAN removal rates for the MB3 media was the highest of the three media types at both the low and high feed load rates averaging 12.3% and 14.4%, respectively. The MB3 media was selected for use in the moving bed biofilters because of the greater VTR and removal efficiency results for use in the 0.11 m3 moving bed biofilters of the hatchery recirculating aquaculture system.  相似文献   

8.
Higher-energy fish feeds can reduce waste discharges and might also improve water quality in recirculating fish-culture systems. A higher-energy diet, Zeigler Salmon High Energy feed (HE; 45% protein, 20% fat, 17.4 MJ digestible energy kg-1) and a lower-energy diet, Zeigler Hi-Fat Trout Grower (LE; 38% protein, 12% fat, 14.6 MJ digestible energy kg -1) were fed ad libitum at different times to rainbow trout, Oncorhynchus mykiss (Walbaum), in a semi-closed recirculating culture system by means of demand feeders. The system contained two 10-m3 fish-culture tanks, each with a downstream microscreen (80 μn) filter. Feeding rates per day and per unit biomass were not significantly different between diets. In general, use of HE was associated with higher levels of total ammonia nitrogen (TAN) and NO2-N, lower BOD5 and total suspended solids (TSS), and lower effluent releases of suspended solids per unit feed, NO3-N per unit feed, and dissolved phosphorus per unit feed. Although total effluent P per unit feed or P fed did not differ significantly between diets, HE had significantly more of the total effluent P in the settleable solids, 85% vs. 76%. Differences in water quality in the system were probably not of great importance with respect to fish health.  相似文献   

9.
Hydroponic plants can efficiently absorb and uptake soluble compounds in wastewater but they have low abilities to remove suspended solids due to the lack of culture media to trap solids. This paper presented an improved hydroponic method for effective treatment of the wastewater from the backwash of recirculating aquacultural systems. The ryegrass (Lolium perenne Lam) was cultured with improved media consisting of perforated plastic plates and several layers of unwoven cotton fabric. The plate/fabric/grass cells with one, three, five, and seven layers of fabric were studied. After one vertical filtration pass through the cells, the removals were 48, 59, 60 and 63% for total solids (TS), 48, 58, 63 and 69% for volatile solids (VS), and 4, 7, 14 and 25% for suspended solids (SS), respectively, for different cells with one, three, five, and seven layers of fabric. It was found that increasing the number of vertical filtration passes through the cells improved the solids removal. The 1-day treatment in the recycling irrigation and treatment system with five cells ( = 0.8 m2 grass) removed 66% TS, 71% VS, and 91% SS, and absorbed 72% total nitrogen (TN), 80% total phosphorus (TP), 63% chemical oxygen demand (COD), and 85% total ammonia nitrogen (TAN). This hydroponic plate/fabric/grass system is a simple and efficient technology for the effective eco-treatment of aquacultural wastewater with relatively high concentrations of suspended solids.  相似文献   

10.
In order to determine the composition, shape and structure of micro-particles in a cold water recirculating plant raising juvenile Atlantic salmon to the smolt stage, samples of suspended solids, collected on classification meshes, and samples of particles in the culture water were examined microscopically. Concurrent gravimetric tests were attempted which method proved unusable due to clogging of the meshes by a viscid material, especially for particles under 40 μm. It was determined that this viscid material, also evident on the classification screens, constituted a major portion of the less dense particles (1050 kg/m3) by floccing fine particles. Staining indicated that the viscid material was primarily mucus with some gelatinized starches from the feed. Undigested feed stirred in distilled, filtered water were also examined microscopically. Again a viscid coating was found on the filter media, but in this case the primary source appeared to be gelatinized starches. The lighter fraction was essentially absent. In both the culture water and the feed samples, the heavier fraction, 1150 kg/m3, appears to originate primarily from the heavy, brown, indigestible cellulose fraction of the ground wheat in the feed.  相似文献   

11.
A partial-reuse system for coldwater aquaculture   总被引:7,自引:0,他引:7  
A model partial-reuse system is described that provides an alternative to salmonid production in serial-reuse raceway systems and has potential application in other fish-culture situations. The partial-reuse system contained three 10 m3 circular ‘Cornell-type’ dual-drain culture tanks. The side-wall discharge from the culture tanks was treated across a microscreen drum filter, then the water was pumped to the head of the system where dissolved carbon dioxide (CO2) stripping and pure oxygen (O2) supplementation took place before the water returned to the culture tanks. Dilution with make-up water controlled accumulations of total ammonia nitrogen (TAN). An automatic pH control system that modulated the stripping column fan ‘on’ and ‘off’ was used to limit the fractions of CO2 and unionized ammonia nitrogen (NH3---N). The partial-reuse system was evaluated during the culture of eight separate cohorts of advanced fingerlings, i.e., Arctic char, rainbow trout, and an all female brook trout × Arctic char hybrid. The fish performed well, even under intensive conditions, which were indicated by dissolved O2 consumption across the culture tank that went as high as 13 mg/L and fish-culture densities that were often between 100 and 148 kg/m3. Over all cohorts, feed conversion rates ranged from 1.0 to 1.3, specific growth rates (SGR) ranged from 1.32 to 2.45% body weight per day, and thermal growth coefficients ranged from 0.00132 to 0.00218. The partial-reuse system maintained safe water quality in all cases except for the first cohort—when the stripping column fan failed. The ‘Cornell-type’ dual-drain tank was found to rapidly (within only 1–2 min) and gently concentrate and flush approximately 68–88% (79% overall average) of the TSS produced daily within only 12–18% of the tank’s total water flow. Mean TSS concentrations discharged through the three culture tanks’ bottom-center drains (average of 17.1 mg/L) was 8.7 times greater than the TSS concentration discharged through the three culture tanks’ side-wall drains (average of 2.2 mg/L). Overall, approximately 82% of the TSS produced in the partial-reuse system was captured in an off-line settling tank, which is better TSS removal than others have estimated for serial-reuse systems (approximately 25–50%). For the two cohorts of rainbow trout, the partial-reuse system sustained a production level of 35–45 kg per year of fish for every 1 L/min of make-up water, which is approximately six to seven times greater than the typical 6 kg per year of trout produced for every 1 L/min of water in Idaho serial-reuse raceway systems.  相似文献   

12.
The objective of this research was to evaluate the dissolved carbon dioxide stripping efficiency of two types of 1-m tall structured plastic packing (tubular NORPAC and structured block CF-3000 Accu-Pac media) that were placed separately in two full-scale forced-ventilation cascade columns that were located within a coldwater recirculating aquaculture system at the Freshwater Institute. These two structured packing types were selected because they both provide large 4–5 cm void spaces that are either vertically-continuous (e.g. the tubular NORPAC) or an open structure with zigzagging but continuous void spaces (e.g. the blocks of cross-corrugated sheet media), which should reduce the likelihood of plugging with biosolids. Water flow rates were adjusted so that each cascade column was loaded with either 87, 136 and 187 m3/h water flow per m2 of cascade column plan area (i.e. 35, 56 and 76 gpm/ft2). Air:water loading rates of 2.2:1 to 3.4:1, 5.1:1 to 5.6:1, and 9.5:1 to 9.9:1 were produced by setting the water flow rates through each column at 1.62, 2.54 and 3.48 m3/min, respectively, and then measuring the resulting air flow rate through the column under these conditions. As expected, the dissolved carbon dioxide removal efficiencies of both structured packing tested were found to depend on the volumetric air:water loading rate applied. The lowest volumetric air:water loading rate (i.e. 2.2:1 to 3.4:1) resulted in only 21–24% dissolved carbon dioxide removal. However, the dissolved carbon dioxide removal efficiencies rose to 32.4–33.6 and 35.8–37.2% for the medium and high air:water loading rates, i.e. 5.1:1 to 5.6:1 and 9.5:1 to 9.9:1, respectively. A second objective of this research was to determine if either packing would plug with biosolids after long-term operation. At the end of approximately 1 year of operation, both of the plastic packing materials were examined from the top of the packing to determine if potential fouling or plugging problems were apparent. A thin layer of brown biofilm covered both packings, but the biofilm did not appear to threaten water or airflow through the packing. In addition, no large mats of biosolids were visible from the top of either column. However, flooding at the interface of the support screen and the tubular NORPAC was suspected to have reduced air flows measured at the highest hydraulic loading rate tested (i.e. at 187 m3/h per m2), which coincided with the lowest air:water loading rates tested.  相似文献   

13.
An indoor aquaponic system (i.e., the integration of fish culture with hydroponic plant production in a recirculating setup) was operated for maximizing water reuse and year-round intensive food production (Nile tilapia, Oreochromis niloticus , and leaf lettuce) at different fish feed to plants ratios. The system consisted of a fish culture component, solid removal component, and hydroponic component comprising six long channels with floating styrofoam rafts for holding plants. Fish culture effluents flowed by gravity from the fish culture component to the solid removal component and then to the hydroponic component. Effluents were collected in a sump from which a 1-horsepower in-line pump recirculated the water back to the fish culture tanks at a rate of about 250 L/min. The hydroponic component performed as biofilter and effectively managed the water quality. Fish production was staggered to harvest one of the four fish tanks at regular intervals when fish attained a minimum weight of 250 g. Out of the total eight harvests in 13 mo, net fish production per harvest averaged 33.5 kg/m3 of water with an overall water consumption of 320 L/kg of fish produced along with the production of leaf lettuce at 42 heads/m2 of hydroponic surface area. Only 1.4% of the total system water was added daily to compensate the evaporation and transpiration losses. A ratio of 56 g fish feed/m2 of hydroponic surface effectively controlled nutrient buildup in the effluents. However, plant density could be decreased from 42 to 25–30 plants/m2 to produce a better quality lettuce.  相似文献   

14.
Intensive recirculating aquaculture relies on biofilters to sustain satisfactory water quality in the system. Fluidized bed and immobilized cell technologies were used to remove ammonia from the water and maintain fish health. A high‐rate nitrifying fluidized bed biofilter combined with valveless filter was designed for use in a recirculation aquaculture system (RAS). The suspended solids produced during fish culture could automatically be removed using a valveless filter. Natural porosity with fitting proportion, steady fluidization and expanding rate was chosen as the fluidized carrier. The technology of bacterial separation and cultivation was used. The immobilized Rhodopseudomonas palustris (R. palustris) produced through a biotechnologically embedding medium is suitable for fish and could help prevent diseases. Nitrification was promoted through the selective rearing of nitrobacteria in a fluidized bed biofilter. Water quality was improved using fluidized bed biofilter and immobilized R. palustris in the RAS. In addition, the proposed system was able to reduce costs. Maximum fish load was 45 ± 3 kg m?3 in the closed recirculating water fish culture system, and water use was reduced by 80–90%. The total ammonia nitrogen removal rate of the technology was 80–95%, and nitrite N removal rate was above 80%.  相似文献   

15.
A low‐head recirculating aquaculture system (RAS) for the production of Florida pompano, Trachinotus carolinus, from juvenile to market size was evaluated. The 32.4‐m3 RAS consisted of three dual‐drain, 3‐m diameter culture tanks of 7.8‐m3 volume each, two 0.71‐m3 moving bed bioreactors filled with media (67% fill with K1 Kaldness media) for biofiltration, two degassing towers for CO2 removal and aeration, a drum filter with a 40‐µm screen for solids removal, and a 1‐hp low‐head propeller pump for water circulation. Supplemental oxygenation was provided in each tank by ultrafine ceramic diffusers and system salinity was maintained at 7.0 g/L. Juvenile pompano (0.043 kg mean weight) were stocked into each of the three tanks at an initial density of 1.7 kg/m3 (300 fish/tank). After 306 d of culture, the mean weight of the fish harvested from each tank ranged from 0.589 to 0.655 kg with survival ranging from 57.7 to 81.7%. During the culture period, the average water use per kilogram of fish was 3.26 or 1.82 m3 per fish harvested. Energy consumption per kilogram of fish was 47.2 or 22.4 kwh per fish harvested. The mean volumetric total ammonia nitrogen (TAN) removal rate of the bioreactors was 127.6 ± 58.3 g TAN removed/m3 media‐d with an average of 33.0% removal per pass. Results of this evaluation suggest that system modifications are warranted to enhance production to commercial levels (>60 kg/m3).  相似文献   

16.
This study examined the effects of different hydraulic loading rates on the treatment efficiency of subsurface flow (SSF) constructed wetlands treating effluents from trout farming over a period of 6 months. Six identical wetland cells with a pre-sedimentation zone of 9.6 m2 and a root zone of 23.6 m2 were loaded with effluents from intensive trout farming (> 2.1 kg feeding stuff per L/s and day). The total runoff of 13.2 L/s was treated in the wetland cells, where two duplicate cells received equal hydraulic loads of 3.9, 1.8 and 0.9 L/s. All examined wetland cells had significant treatment effects on the nutrient fractions containing particulate matter [total nitrogen (TN), total phosphorous (TP), biological oxygen demand in 5 days (BOD5), chemical oxygen demand (COD), and total suspended solids (TSS)].

Efficiency was between 5.5% for TN and 90.1% for TSS. The SSF wetland also had a high treatment effect on total ammonia nitrogen (TAN), with efficiencies of 61.2 to 87.8%. Nitrate nitrogen (NO3–N) and phosphate phosphorous (PO4–P) showed a significant increase in the wetland effluent by 8.4 to 209%. Nitrite nitrogen (NO2–N), had no significant, or significant effluent increase depending on the inflow rate. Treatment efficiency for particulate nutrients and TAN increased with decreasing hydraulic load, while the differences between 1.8 and 0.9 L/s were not significant. The treatment efficiency for TP was constant for all cells, at around 40%. The wetland receiving 3.9 L/s was over-flooded after 10 to 12 weeks due to colmatation. Nevertheless, the wetland still showed high treatment efficiencies. For commercial trout farms, SSF wetlands are a highly effective method of effluent treatment. A hydraulic load of 1 L/s on 13.3 m2 wetland area (1.8 L/s on the examined wetland) seems most suitable. Higher loads lead to accelerated wetland colmatation, while lower loads waste space.  相似文献   


17.
Water recirculating systems have been used in the shellfish industry for depuration and wet-storage. Knowledge of shellfish excretion characteristics is critical to recirculating system design. In this study, the excretion rate of total ammonia nitrogen (TAN), total Kjeldahl nitrogen (TKN), and 5-day biochemical oxygen demand (BOD5) from Manila clams (Tapes philippinarum) were investigated under both laboratory and commercial conditions. The laboratory tests were conducted under temperatures ranging from 3 to 30°C. The experimental results showed that temperature was a key factor in determining the excretion rate of all the above parameters. The relationship between TAN excretion rate (RTAN) and temperature (T) can be represented by an exponential function (RTAN=0.57×1.25T). For the temperature range between 3 and 20°C, the daily mean excretion rates of TAN, TKN and BOD5 ranged between 1.5–46.1, 4.8–131.0 and 57.4–219.4 mg per kilogram of the clams (wet weight with shell on), respectively. There were linear correlations between TAN, TKN and BOD5 production rates. The data presented in this paper can be used to estimate waste generation from a given shellfish processing operation and to size the waste treatment components for a recirculating depuration (or wet-storage) system.  相似文献   

18.
Aerobic biological filtration systems employing nitrifying bacteria to remediate excess ammonia and nitrite concentrations are common components of recirculating aquaculture systems (RAS). However, significant water exchange may still be necessary to reduce nitrate concentrations to acceptable levels unless denitrification systems are included in the RAS design. This study evaluated the design of a full scale denitrification reactor in a commercial culture RAS application. Four carbon sources were evaluated including methanol, acetic acid, molasses and Cerelose™, a hydrolyzed starch, to determine their applicability under commercial culture conditions and to determine if any of these carbon sources encouraged the production of two common “off-flavor” compounds, 2-methyisoborneol (MIB) or geosmin. The denitrification design consisted of a 1.89 m3 covered conical bottom polyethylene tank containing 1.0 m3 media through which water up-flowed at a rate of 10 lpm. A commercial aquaculture system housing 6 metric tonnes of Siberian sturgeon was used to generate nitrate through nitrification in a moving bed biological filter. All four carbon sources were able to effectively reduce nitrate to near zero concentrations from influent concentrations ranging from 11 to 57 mg/l NO3–N, and the maximum daily denitrification rate was 670–680 g nitrogen removed/m3 media/day, regardless of the carbon source. Although nitrite production was not a problem once the reactors achieved a constant effluent nitrate, ammonia production was a significant problem for units fed molasses and to a less extent Cerelose™. Maximum measured ammonia concentrations in the reactor effluents for methanol, vinegar, Cerelose™ and molasses were 1.62 ± 0.10, 2.83 ± 0.17, 4.55 ± 0.45 and 5.25 ± 1.26 mg/l NH3–N, respectively. Turbidity production was significantly increased in reactors fed molasses and to a less extent Cerelose™. Concentrations of geosmin and MIB were not significantly increased in any of the denitrification reactors, regardless of carbon source. Because of its very low cost compared to the other sources tested, molasses may be an attractive carbon source for denitrification if issues of ammonia production, turbidity and foaming can be resolved.  相似文献   

19.
The total ammonia nitrogen (TAN) excretion of spiny lobsters Jasus edwardsii and Panulirus cygnus, was determined in relation to temperature, body weight, emersion, daily rhythm and feeding. Temperature and body weight had large influences on the rate of TAN excretion. Exponential relationships were found between temperature (T) and TAN excretion of both species. These were described by the following equations: J. edwardsii Log10 TAN=0.041T−3.57 (r2=0.979, F=143.2, P=0.001), P. cygnus Log10 TAN=0.057T−3.90 (r2=0.987, F=302.2, P<0.001). TAN excretions of both species were positively correlated to body weight (W), and the relationships were described by the following equations: J. edwardsii Log10 TAN=0.473 log10 W−1.704 (r2=0.42, F=14.05, P=0.001), P. cygnus Log10 TAN=0.499 log10 W−1.346 (r2=0.69, F=44.18, P<0.001). TAN excretion increased significantly when lobsters were re-immersed after a 30 min period of emersion. However, it returned to pre-emersion levels by the second hour of re-immersion. Daily rhythm resulted in a significantly higher nocturnal TAN excretion rate for J. edwardsii; no daily rhythm was observed for P. cygnus. Feeding had the largest influence on TAN excretion, with maximum increases of 6.28 (J. edwardsii) and 5.60 (P. cygnus) times the pre-feeding level. TAN excretion rates remained significantly higher than the pre-feeding levels for an extended period (26 h, J. edwardsii; 30 h, P. cygnus). Implications for the use of purging tanks in lobster holding facilities and for the design of biofiltration systems are discussed.  相似文献   

20.
Disease epizootics have negatively affected production and expansion of the shrimp culture industry. This, along with environmental concerns regarding limited water resources and contamination of receiving streams, has caused the industry to investigate more sustainable and biosecure management practices. A study was conducted to evaluate the effect of limited water exchange on water quality, growth and survival of the Pacific white shrimp Litopenaeus vannamei postlarvae (PL) in greenhouse-enclosed raceways. Concentrations of NH4-N did not exceed 2.0 mg l−1 during this period; whereas, NO2-N exceeded 26.4 mg l−1, indicating assimilation of primary amines by primary productivity. Periodic removal of suspended solids by a common pressurized sand filter and injection of oxygen into culture water resulted in high-survival rates for both raceways (97.5 and 106.0%) with an average biomass yield of 4.29 ± 0.06 kg m−3. Shrimp samples collected during the nursery trial and at harvest showed no signs of bacterial or viral pathogen infections.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号