首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 499 毫秒
1.
The predominant adrenergic protoalkaloid found in the peel and fruit of bitter orange, Citrus aurantium, is synephrine. Synephrine is reputed to have thermogenic properties and is used as a dietary supplement to enhance energy and promote weight loss. However, there exists some concern that the consumption of dietary supplements containing synephrine or similar protoalkaloids may contribute to adverse cardiovascular events. This study developed and validated a positive-ion mode liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the quantitative determination of the major (synephrine) and minor (tyramine, N-methyltyramine, octopamine, and hordenine) adrenergic protoalkaloids in a suite of National Institute of Standards and Technology (NIST) bitter orange Standard Reference Materials (SRMs): SRM 3258 Bitter Orange Fruit, SRM 3259 Bitter Orange Extract, and SRM 3260 Bitter Orange Solid Oral Dosage Form. The limit of quantitation (LOQ) for all protoalkaloids is approximately 1 pg on-column, except for octopamine (20 pg on-column). Additionally, the method has a linear dynamic range of > or =3 orders of magnitude for all of the protoalkaloids. Individual, as well as "total", protoalkaloid levels (milligrams per kilogram) in the NIST SRMs were determined and compared to the levels measured by an independent liquid chromatography/fluorescence detection (LC/FD) method. Satisfactory concordance between the LC/MS/MS and LC/FD protoalkaloid measurements was demonstrated. LC/MS/MS analysis of the protoalkaloids in the SRMs resulted in mean measurement imprecision levels of < or =10% coefficient of variation (% CV).  相似文献   

2.
As a consequence of the adulteration of infant formulas and milk powders with melamine (MEL) in China in 2008, much attention has been devoted to the analysis of MEL [and cyanuric acid (CA)] in dairy products. Several methods based on high-performance liquid chromatography (HPLC), liquid chromatography-tandem mass spectrometry (LC-MS/MS), nuclear magnetic resonance (NMR), or Raman spectroscopy have been described in the literature. However, no method is available for the simultaneous determination of MEL and CA in other raw materials, which are considered as high-risk materials for economically motivated adulteration. The present paper reports the results of an interlaboratory-based performance evaluation conducted with seven laboratories worldwide. The purpose was to demonstrate the ability of a cleanup-free LC-MS/MS method, originally developed for cow's milk and milk-powdered infant formula, to quantify MEL and CA in egg powder and soy protein. Limit of detection (LOD) and limit of quantification (LOQ) were 0.02 and 0.05 mg/kg for MEL in egg powder and soy protein, respectively. For CA, LOD and LOQ were 0.05 and 0.10 mg/kg in egg powder and 1.0 and 1.50 mg/kg in soy protein, respectively. Recoveries ranged within a 97-113% range for both MEL and CA in egg powder and soy protein. Reproducibility values (RSD(R)) from seven laboratories were within a 5.4-11.7% range for both analytes in the considered matrices. Horwitz ratio (HorRat) values between 0.4 and 0.7 indicate acceptable among-laboratory precision for the method described.  相似文献   

3.
A liquid chromatography electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) method was developed and validated to quantify and confirm trace levels of 13 pesticides including aldicarb sulfoxide, aldicarb sulfone, oxamyl, methomyl, formetanate, 3-hydroxycarbofuran, carbendazim, thiabendazole, aldicarb, propoxur, carbofuran, carbaryl, and methiocarb in apple-based infant foods such as apple sauces, apples and strawberries, apples and blueberries, and apples and plums. Data acquisition under MS/MS was achieved by applying multiple reaction monitoring of two fragment ion transitions to provide a high degree of sensitivity and selectivity for both quantification and confirmation. LC/ESI-MS/MS quantitative results were significantly affected by matrices, and thus, the standard addition was employed to compensate for the matrix effects to achieve the best accuracy of the method. Recoveries of 13 pesticides, spiked at 5.0, 25.0, and 45.0 microg/kg, were around 100% using the LC/ESI-MS/MS standard addition. The method detection limits (S/N > or = 3:1) of 13 pesticides were less than 0.2 microg/kg.  相似文献   

4.
A high-performance liquid chromatography (HPLC) method for the qualitative and quantitative analysis of allantoin in silk and seed of Zea mays has been developed. Allantoin separation in crude extract was achieved using a C 18 column and phosphate buffer solution (pH 3.0) as a mobile phase at ambient temperature at a flow rate of 1.0 mL/min and detected at 210 nm. The results showed that the amount of allantoin in samples was between 14 and 271 mg/100 g of dry plant material. A comprehensive validation of the method including sensitivity, linearity, repeatability, and recovery was conducted. The calibration curve was linear over the range of 0.2-200 microg/mL with a correlation coefficient of r2>0.999. Limit of detection (LOD, S/N=3) and limit of quantification (LOQ) values of the allantoin were 0.05 and 0.2 microg/mL (1.0 and 4.0 ng) respectively. The relative standard deviation (RSD) value of the repeatability was reported within 1.2%. The average recovery of allantoin added to samples was 100.6% with RSD of 1.5%.  相似文献   

5.
A simple and rapid method is presented for the analysis of residues of ethylenebis(dithiocarbamate) (maneb, zineb, and mancozeb) and N,N-dimethyldithiocarbamate (thiram and ziram) fungicides in dry tobacco leaves and peaches. Residues are extracted and hydrolyzed to CS(2) in a single step by use of microwave energy in a closed-vessel system while the evolved CS(2) trapped in a layer of iso-octane overlaying the reaction mixture is taken for gas chromatographic-flame photometric analysis. This combined extraction-hydrolysis step is carried out in 10 and 15 min for sets of 12 samples of tobacco and peach matrices, respectively. Total sample preparation time for GC analysis is 40 min. The limits of detection (LOD) are 0.005 mg/kg for thiram and ziram on peaches and 0.1 mg/kg for maneb, zineb, and mancozeb on tobacco. The respective LOD and limit of quantification (LOQ) levels in CS(2) equivalents are 0.003 and 0.006 mg/kg on peaches and 0.04 and 0.2 mg/kg on tobacco, respectively. Recoveries in the 0.01-60 mg/kg fortification range are 80-100% with respective relative standard deviations <20%. The method was used for the analysis of >3000 commercial tobacco samples including also different marketed cigarette brands.  相似文献   

6.
A method was developed for the quantification of alternariol and alternariol monomethyl ether on tangerines with and without symptoms of Alternaria brown spot disease. The method employs solid-phase extraction for cleanup, followed by high-performance liquid chromatography coupled with tandem mass spectrometry (HPLC-MS/MS) for detection. This method was validated on flavedo (exocarp or epicarp, exterior yellow peel) and on albedo tissue (mesocarp, interior white peel). An excellent linearity over a range of 0.50-20.0 mg/kg was achieved, with r2 >or= 0.997. The limits of detection (LOD) and quantification (LOQ) were fewer than 0.13 and 0.50 microg/kg, respectively. The relative standard deviations (RSDs) were 相似文献   

7.
Two liquid chromatographic methods that involve precolumn derivatization with o-phthaladehyde (OPA) and phenylisothiocyanate (PITC) with fluorescence and diode array UV detection for the determination of theanine have been developed. The chromatographic separations were achieved by reverse-phase high-performance liquid chromatography using octadecyl columns and gradient elution. The methods were applied to evaluate the theanine content of commercial tea leaves. The coefficient of variation of the peak area repeatability for within day (n = 8) and between day (n = 8 over 10 days) was lower than 3% for both of the methods. The estimated limit of detection (LOD) and limit of quantitation (LOQ) for the OPA method was 0.12 and 0.35 microg theanine, respectively. The PITC method was 500-fold more sensitive with LOD and LOQ values of 0.25 and 0.75 ng, respectively. The theanine content of the commercial tea samples varied from 2-5 mg/g leaf. The overall % recoveries for these methods ranged from 93-99.3. The sensitivity and simplicity of the method render them suitable for use in quality control laboratories.  相似文献   

8.
A simple and reproducible method for qualitative and quantitative analysis of phenolic compounds in virgin olive oils by solid-phase extraction (SPE), high performance liquid chromatography with diode array detector (HPLC-DAD), and HPLC-mass spectrometry (MS) in tandem mode was developed. The polar fraction was obtained from samples of three different virgin olive oils. Detection and quantification were performed at 280, 240, and 320 nm. For identification purposes, HPLC-MS/MS was equipped with turbo ion spray source in the negative-ion mode. Twenty compounds of twenty-three detected and quantified were characterized. The method showed satisfactory linearity (r > 0.99), good recovery, satisfactory precision, and appropriate limits of detection (LOD) and quantification (LOQ).  相似文献   

9.
A method is reported for the determination of cyromazine and melamine residues in soil. Soil samples are extracted twice via mechanical shaking, each time with 70% acetonitrile/30% 0.050 M ammomium carbonate for 30 min. An aliquot portion of the pooled extracts is subjected to strong cation exchange (SCX) purification on AG 50W-X4 resin. Final analysis is accomplished using liquid chromatography-ultraviolet (LC-UV) detection at a wavelength of 214 nm. Confirmatory analyses can be performed using gas chromatography-mass selective detection (GC-MSD) in the selected ion monitoring (SIM) mode. The limit of detection (LOD) is 2.5 ng injected and the limit of quantification (LOQ) is 10 ppb when using LC-UV for the analysis of N-cyclopropyl-1,3,5-triazine-2,4, 6-triamine (cyromazine) and 1,3,5-triazine-2,4,6-triamine (melamine). The LOD is 0.050 ng injected and the LOQ is 10 ppb when using GC-MSD for confirmatory analyses. The mean procedural recoveries were 97 and 95% and the standard deviations were 16 and 11% for cyromazine and melamine, respectively (n = 24), when using LC-UV. The mean procedural recoveries were 107 and 92% and the standard deviations were 9.9 and 16% for cyromazine and melamine, respectively (n = 29), when using GC-MSD. The method validation study was conducted under U.S. EPA FIFRA Good Laboratory Practice Guidelines 40 CFR 160. The method also passed an Independent Laboratory Validation (ILV) as per U.S. EPA FIFRA Subdivision N.  相似文献   

10.
A method using liquid chromatography electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) for the determination of trace levels of five macrolide antibiotics (spiramycin, tilmicosin, oleandomycin, erythromycin, and tylosin) in eggs is presented. Data acquisition under MS/MS was achieved by applying multiple reaction monitoring (MRM) of two or three fragment ion transitions to provide a high degree of sensitivity and specificity for both quantification and confirmation. Matrix-matched standard calibration curves were used to achieve the best accuracy of the method. A fully nested experimental design was used to study the measurement uncertainty arising from intermediate precision and trueness or proportional bias. The overall recoveries, that is, those determined by the nested experiments, of spiramycin, tilmicosin, oleandomycin, erythromycin, and tylosin at fortified levels of 60, 100, 200, and 300 microg/kg were 96.8, 98.2, 98.3, 98.8, and 95.4%, respectively. The LC/ESI-MS/MS method detection limits (S/N > or = 3:1) of five macrolides were <1.0 microg/kg.  相似文献   

11.
An ultrahigh-performance liquid chromatography (UHPLC) tandem mass spectrometric (MS/MS) method was developed for the simultaneous quantification of 2-acetyl-4-tetrahydroxybutylimidazole (THI), 2- and 4-methylimidazoles (2-MI and 4-MI), and 5-hydroxymethylfurfural (HMF) in beverage samples. A C30 reversed-phase column was used in this method, providing sufficient retention and total resolution for all targeted analytes, with an MS/MS instrument operated in selected reaction monitoring (SRM) mode for sensitive and selective detection using isotope-labeled 4-methyl-d(3)-imidazole (4-MI-d(3)) as the internal standard (IS). This method demonstrates lower limit of quantification (LLOQ) at 1 ng/mL and coefficient of determination (r(2)) >0.999 for each analyte with a calibration range established from 1 to 500 ng/mL. This method also demonstrates excellent quantification accuracy (84.6-105% at 5 ng/mL, n = 7), precision (RSD < 7% at 5 ng/mL, n = 7), and recovery (88.8-99.5% at 10, 100, and 200 ng/mL, n = 3). Seventeen carbonated beverage samples were tested (n = 2) in this study including 13 dark-colored beverage samples with different flavors and varieties and 4 light-colored beverage samples. Three target analytes were quantified in these samples with concentrations in the range from 284 to 644 ng/mL for 4-MI and from 706 to 4940 ng/mL for HMF. THI was detected in only one sample at 6.35 ng/mL.  相似文献   

12.
As more genetically modified plant events are approved for commercialization worldwide, the event-specific PCR method has become the key method for genetically modified organism (GMO) identification and quantification. This study reveals the 3' flanking sequence of the exogenous integration of Oxy-235 canola employing thermal asymmetric interlaced PCR (TAIL-PCR). On the basis of the revealed 3' flanking sequence, PCR primers and TaqMan probe were designed and qualitative and quantitative PCR assays were established for Oxy-235 canola. The specificity and limits of detection (LOD) and quantification (LOQ) of these two PCR assays were validated to as low as 0.1% for the relative LOD of qualitative PCR assay; the absolute LOD and LOQ were low to 10 and 20 copies of canola genomic DNA in quantitative PCR assay, respectively. Furthermore, ideal quantified results were obtained in the practical canola sample detection. All of the results indicate that the developed qualitative and quantitative PCR methods based on the revealed 3' integration flanking sequence are suitable for GM canola Oxy-235 identification and quantification.  相似文献   

13.
Fusarin C is a mycotoxin that is produced by a variety of Fusarium species and is therefore a possible contaminant in food and feed. For this reason, a reliable high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method for the determination of fusarin C in food and feed samples was developed based on dispersive solid phase extraction (DSPE). This method has a limit of detection (LOD) of 2 μg/kg, a limit of quantitation (LOQ) of 7 μg/kg, and a recovery rate of 80%. Fifty different corn samples were analyzed, and fusarin C was detected in 40 of them. The fusarin C level varied in kernels of corn ears from not detectable up to 83 mg/kg and in food samples from not detectable up to 28 μg/kg. The co-occurrence of further structural analogues of fusarin C was confirmed by high-performance liquid chromatography Fourier transformation mass spectrometry (HPLC-FTMS). In addition, the stability of fusarin C under storage conditions was evaluated.  相似文献   

14.
A novel multiresidue analysis method is developed for the determination of twenty phthalate esters at the μg/kg level in edible vegetable oils by microwave-assisted extraction-gel permeation chromatography-solid phase extraction-high resolution gas chromatography-tandem mass spectrometry (MAE-GPC-SPE-HRGC-MS/MS). The samples were extracted with methanol under microwave incubation. Cleanup was carried out with GPC followed by a further C18 SPE column and then separated by the HP-5MS capillary column under a temperature program. The eluents were qualitatively and quantitatively determined by tandem mass analyzer with selected reaction monitoring (SRM) type and positive ion mode. The calibration curves showed good linearity in the range 5 μg/kg to 2.50 mg/kg with correlation coefficients larger than 0.999. Low detection limits (LODs) of 0.218-1.367 μg/kg and quantification limits (LOQ) of 0.72-4.51 μg/kg were achieved. The mean recoveries were in the range from 93.04% to 104.6% at 5, 15, and 40 μg/kg spiked levels, and the relative standard deviations (RSDs) were in the range of 1.01% and 5.26% (n = 7). This method could potentially overcome the interference from large amounts of lipids and pigment. The real sample test showed this method can be used for sensitive and accurate determination and confirmation of phthalate ester residues in high-fat and complex samples.  相似文献   

15.
A specific and sensitive method based on liquid chromatography-tandem mass spectrometry using atmospheric pressure chemical ionization (LC-APCI-MS/MS) has been developed for the determination of four anabolic steroids [trenbolone, methylboldenone, methyltestosterone, and norethandrolone] in bovine muscle. Methyltestosterone- d 3 was used as internal standard. The procedure involved enzymatic hydrolysis, extraction with tert-butyl methyl ether, defattening, and final cleanup with solid-phase extraction with Oasis HLB cartridges. The analytes were analyzed by reversed-phase LC-MS/MS, acquiring two diagnostic product ions from the chosen precursor [M + H] (+) for the unambiguous confirmation of hormones. The method was validated according to the European Commission Decision 2002/657/EC for the detection and confirmation of residues in products of animal origin. The limits of detection (LOD) and limits of quantitation (LOQ) were found to be 0.3 ng/g and 1.0 ng/g, respectively. The accuracy and precision have been determined, with recoveries ranging from 83% to 104% and the CV factor not exceeding the value of 7%. The decision limits CCalpha were calculated and ranged from 0.05 to 0.15 ng/g while the detection capabilities CCbeta ranged from 0.09 to 0.25 ng/g. The method proved to be sensitive and reliable and thus renders an appropriate means for residue analysis studies.  相似文献   

16.
The present work describes a solid-phase microextraction (SPME) gas chromatography-tandem mass spectrometry (MS/MS) method to quantify 24 pesticides in fortified white wine and fortified red wine. In this study "fortified wine" refers to a wine in which fermentation is arrested before completion by alcohol distillate addition, allowing sugar and alcoholic contents to be higher (around 80-100 g/L total sugars and 19-22% alcohol strength (v/v)). The analytical method showed good linearity, presenting correlation coefficients (R(2)) ≥ 0.989 for all compounds. Limits of detection (LOD) and quantitation (LOQ) in the ranges of 0.05-72.35 and 0.16-219.23 μg/L, respectively, were obtained. LOQs are below the maximum residue levels (MRL) set by European Regulation for grapes. The proposed method was applied to 17 commercial fortified wines. The analyzed pesticides were not detected in the wines tested.  相似文献   

17.
Polymerase chain reaction (PCR) methods have been the main technical support for the detection of genetically modified organisms (GMOs). To date, GMO-specific PCR detection strategies have been developed basically at four different levels, such as screening-, gene-, construct-, and event-specific detection methods. Event-specific PCR detection method is the primary trend in GMO detection because of its high specificity based on the flanking sequence of exogenous integrant. GM canola, event T45, with tolerance to glufosinate ammonium is one of the commercial genetically modified (GM) canola events approved in China. In this study, the 5'-integration junction sequence between host plant DNA and the integrated gene construct of T45 canola was cloned and revealed by means of TAIL-PCR. Specific PCR primers and TaqMan probes were designed based upon the revealed sequence, and qualitative and quantitative TaqMan real-time PCR detection assays employing these primers and probe were developed. In qualitative PCR, the limit of detection (LOD) was 0.1% for T45 canola in 100 ng of genomic DNA. The quantitative PCR assay showed limits of detection and quantification (LOD and LOQ) of 5 and 50 haploid genome copies, respectively. In addition, three mixed canola samples with known GM contents were detected employing the developed real-time PCR assay, and expected results were obtained. These results indicated that the developed event-specific PCR methods can be used for identification and quantification of T45 canola and its derivates.  相似文献   

18.
The aim of this study was to develop an analytical procedure based on liquid chromatography-mass spectrometry (LC–MS) for analysis of monomeric organic N compounds in soil extracts. To benchmark the developed LC–MS method it was compared with a capillary electrophoresis–mass spectrometry (CE–MS) method recently used for analysis of small organic N monomers in soil. The separation was optimized and analytical performance assessed with 69 purified standards, then the LC–MS method was used to analyse soil extracts. Sixty-two out of 69 standards were analysable by LC–MS with separation on a hydrophilic interaction liquid chromatography column. The seven compounds that could not be analysed were strongly cationic polyamines. Limits of detection for a 5 μL injection ranged between 0.002 and 0.38 μmol L−1, with the majority (49 out of 62) having limits of detection better than 0.05 μmol L−1. The overall profile and concentration of small organic N monomers in soil extracts was broadly similar between LC–MS and CE–MS, with the notable exception of four ureides that were detected by LC–MS only. In soil extracts that had been concentrated ten-fold the detection and quantification of (some) organic N compounds was compromised by the presence of large amounts of inorganic salts. The developed LC–MS method offered advantages and disadvantages relative to CE–MS, and a combination of the two methods would achieve the broadest possible coverage of organic N in soil extracts.  相似文献   

19.
A reverse phase liquid chromatographic (LC) method has been developed for the assay of calcium pantothenate in commercial multivitamin tablet formulations and raw materials. The assay was validated according to the Pharmaceutical Manufacturers Association Quality Control HPLC Committee guidelines. The chromatographic system includes a C-18 column and a mobile phase consisting of 0.25M sodium phosphate buffer, pH 2.5, and acetonitrile (97 + 3 v/v). The column effluent is monitored by UV detection at 205 nm. The sample preparation involves only extraction in water followed by filtration. The method is stability-indicating with a detection limit of approximately 50 ng/mL of the calcium pantothenate in the samples. The system is linear from at least 0.02 to 0.10 mg/mL. The mean recovery of spiked placebos ranged from 98.7 to 99.8%. The within-day precision of the assay on finished products (N = 6) ranged from 0.3 to 2.0% CV. A system suitability criterion for resolution is based on the separation between calcium pantothenate and 2 closely eluting compounds, saccharin and a saccharin degradation product, 2-sulfamoylbenzoic acid.  相似文献   

20.
A method based on a gel permeation chromatography (GPC) extraction procedure combined with an additional cleanup by solid-phase extraction (SPE) on silica gel and liquid chromatography-mass spectrometry (LC-MS) detection has been validated for the analysis of seven glycidyl esters (GEs) including glycidyl laurate, myristate, palmitate, stearate, oleate, linoleate, and linolenate in various edible oils. This method was conjointly developed and validated by two different laboratories, using two different detection systems, a LC time of flight MS (LC-ToF-MS) and a LC triple-quadrupole MS (LC-MS/MS). The extraction procedure allowed targeting low contamination levels due to a highly efficient matrix removal from the 400 mg oil sample loaded on the GPC column and is suitable for routine analysis as 24 samples can be extracted in an automated and reproducible way every 12 h. GPC extraction combined with SPE cleanup and LC-MS/MS detection leads to a limit of quantification in oil samples between 50 and 100 μg/kg depending on the type of glycidyl ester. Recoveries ranged from 68 to 111% (average = 93%). Quantification was performed by automated standard addition on extracts to compensate matrix effects artifacts. To control recoveries of each sample four isotopically labeled GEs ((13)C(3) or (13)C(4)) were included in the method.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号