A direct competitive chemiluminescent enzyme-linked immunosorbent assay (CL-ELISA) for the determination of ochratoxin A (OTA) was developed using soybean peroxidase (SbP) in combination with 3-(10'-phenothiazinyl)propane-1-sulfonate (SPTZ) and 4-morpholinopyridine (MORPH) as a detection system. By varying the concentrations of the capture monoclonal anti-OTA antibody, a conjugate of OTA with SbP, and the composition of blocking buffers, the conditions of the immunoassay were optimized. Advantages of CL-ELISA were demonstrated by comparison with ELISA with colorimetric detection (COL-ELISA). The values of IC??, IC??, and working range (IC??-IC??) for CL-ELISA and COL-ELISA were 0.01, 0.08, and 0.02-0.3 ng/mL and 0.08, 0.58, and 0.17-2.2 ng/mL, respectively. The recovery values of CL-ELISA from three soybean spiked samples with OTA concentrations of 0.07, 0.1, and 0.15 ng/mL ranged from 72 to 125%. Determination of OTA in 21 various agricultural commodities showed that OTA in 8 examined samples was not detected by COL-ELISA. Furthermore, it was found that in 4 of these 8 samples the developed CL-ELISA determined OTA at levels from 0.96 to 4.64 ng/g.  相似文献   

2.
To develop an enzyme-linked immunosorbent assay for the fungicide fenarimol, two synthesized haptens, haptens-1 and -2, and the purchased 4,4'-DDA were conjugated to carrier proteins (BSA, KLH, and OVA). Polyclonal antibodies raised against hapten-1,2-KLH conjugates in rabbits and the coating antigens of hapten-1,2-BSA conjugates, hapten-2-OVA conjugate, and 4,4'-DDA-BSA conjugate were screened and selected for the homologous and/or heterologous ELISA formats. Two competitive indirect ELISAs were selected: assays I and II. The optimized ciELISAs of assays I and II showed average IC(50) values of fenarimol of 5.4 and 9.4 ng/mL, detection ranges of 1.1-25.9 and 1.1-82.7 ng/mL, and lowest detection limits of 0.3 and 0.3 ng/mL, respectively. The cross-reactivities with several structurally related compounds indicated the importance of the steric fitness in the antigen-antibody interaction. Recoveries of fenarimol from apple and pear samples spiked with the analyte by assay I were in the range of 93-113% by simple extraction, concentration, and dilution. This assay could be a convenient and supplemental analytical tool for monitoring fenarimol residues in environmental and agricultural samples.  相似文献   

3.
A competitive indirect enzyme-linked immunosorbent assay (ciELISA) for the organophosphorus insecticide acephate, O,S-dimethyl acetylphosphoramidothioate, was developed using a polyclonal antibody. Five different haptens mimicking the analyte were synthesized and conjugated with the carrier proteins bovine serum albumin (BSA) and keyhole limpet hemocyanin (KLH) by the N-hydroxysuccinimide active ester and diazotization methods. Polyclonal antibodies raised against hapten-KLH conjugates in rabbits and hapten-BSA conjugates as coating antigens were screened and selected for the assay in the homologous and heterologous ELISA systems. The effects of various assay conditions such as detergent, organic solvents, pH, and preincubation of the mixture of the polyclonal antibody and the analyte on the sensitivity were evaluated. The IC(50) value for acephate was 25 ng/mL in an optimized heterologous system using hapten-4-BSA as a coating antigen and a polyclonal antibody no. 8377 against hapten-1-KLH, showing the detection range of 5-140 ng/mL and the lowest detection limit of 2 ng/mL. The cross-reactivities of the structurally related organophosphorus insecticides, including the major metabolite of the analyte, methamidophos, were less than 1%. Recoveries from the analyte-fortified tap water, mulberry leaves, and lettuce samples in the assay were in the range of 72-121% by simple extraction, concentration, and dilution. These results indicate that the ELISA could be a convenient and supplemental analytical tool for monitoring acephate residues in environmental and agricultural samples.  相似文献   

4.
Staphylococcus aureus enterotoxin B (SEB) is a highly heat resistant enteric toxin with a potential as a biothreat agent. A sensitive method for the detection of staphylococcal enterotoxins is needed for food safety and food defense monitoring. The objectives of this research were to develop a competitive fluorescent immunoassay with detection of SEB below toxic levels of 1 ng/mL and to minimize sample preparation. Anti-SEB was immobilized onto carboxylated polystyrene microparticles, and SEB was labeled with fluorescein isothiocyanate (FITC). The concentrations of these reagents were optimized for the detection of SEB below 1 part per billion (1 ng/mL), and other assay conditions (sample volumes and incubation periods) were optimized. Drinking water and milk samples were spiked with 0.125-10 ng/mL SEB and were equilibrated overnight prior to analysis. The water and milk samples were directly analyzed, but heating the milk samples for 10 min at 90 degrees C improved the assay performance. SEB in samples bound with the anti-SEB linked to the latex followed by the competitive binding of SEB-FITC tracer. The excess, unbound tracer was separated by centrifugation, and the fluorescence density of the supernatant was measured. SEB was detected at levels as low as 0.125 ng/mL in drinking water and 0.5 ng/mL in whole milk. This fluorescent latex particle immunoassay will be utilized for the detection of SEB in various foods matrices.  相似文献   

5.
A competitive indirect enzyme-linked immunosorbent assay was developed for the fungicide iprovalicarb, using a polyclonal antibody produced against a hapten conjugated through the carboxyl group on the benzene ring to keyhole limpet hemocyanin. Under an optimized condition using a heterologous format, an IC(50) of 3.51 ng/mL and the lowest detection limit of 0.065 ng/mL were obtained. When the isopropoxy group was removed from the iprovalicarb structure for the synthesis of a hapten, the resulting hapten was not successful as an immunogen, indicating that the isopropyl moiety was an important epitope, as evidenced by the cross-reactivities of some structurally related compounds. When applied to the real crop and water samples, the recoveries were in the range of 80.52-144.70% (n = 4) and 72.11-100.43% (n = 4), respectively. Accordingly, this ELISA can be used as a useful method for monitoring iprovalicarb residues in crop and water samples.  相似文献   

6.
In this study, 4-aminophenylacetic acid was covalently coupled to aniline to synthesize an intermediate hapten and the intermediate hapten was coupled to β-naphthol to synthesize a tentative hapten of Sudan 3. The hapten was coupled to bovine serum albumin as the immunogen to produce the polyclonal antibody. The obtained antibody was highly specific to Sudan 3, Sudan 1, and Para red, but showed relative low binding ability to Sudan 2, Sudan 4, and Sudan red G. After evaluation of different coating antigens, a heterologous indirect competitive immunoassay was developed to multidetermine the six red dyes in food samples. The cross reactivities to the six analytes were in a range of 21-105%, and the limits of detection were in a range of 0.1-0.8 ng/mL depending on the compound. Intra- and interassay recoveries from the standard fortified blank samples were in a range of 74.5-96.3% with coefficients of variation lower than 15.1%.  相似文献   

7.
The development of a sensitive flow-though immunosensor for the analysis of the mycotoxin zearalenone in cereal samples is described. The sensor was completely automated and was based on a direct competitive immunosorbent assay and fluorescence detection. The mycotoxin competes with a horseradish-peroxidase-labeled derivative for the binding sites of a rabbit polyclonal antibody. Control pore glass covalently bound to Prot A was used for the oriented immobilization of the antibody-antigen immunocomplexes. The immunosensor shows an IC(50) value of 0.087 ng mL(-1) (RSD = 2.8%, n = 6) and a dynamic range from 0.019 to 0.422 ng mL(-1). The limit of detection (90% of blank signal) of 0.007 ng mL(-1) (RSD = 3.9%, n = 3) is lower than previously published methods. Corn, wheat, and swine feed samples have been analyzed with the device after extraction of the analyte using accelerated solvent extraction (ASE). The immunosensor has been validated using a corn certificate reference material and HPLC with fluorescence detection.  相似文献   

8.
An immunochromatography (ICG) strip test for rapid detection of atrazine in water samples was developed. A monoclonal antibody (MAb) specific to atrazine was produced from the cloned hybridoma cell (AT-1-M3) and used to develop a direct competitive enzyme-linked immunosorbent assay (DC-ELISA) and ICG strip. MAb conjugated to colloidal gold, and that was applied to the conjugate pad of the ICG strip. The visual detection limit for the ICG strip was 3 ng/mL. This test required only 10 min to get results and one step of sample to perform the assay. The results of water samples spiked with 5, 10, 20, and 50 ng/mL of atrazine by ICG strip were in good agreement with those obtained by DC-ELISA. The ICG strip was sufficiently sensitive and accurate to be useful for rapid screening of atrazine in various water samples.  相似文献   

9.
The Alternaria mycotoxin tenuazonic acid was derivatized with succinic anhydride and conjugated to keyhole limpet hemocyanin (KLH) and to horseradish peroxidase (HRP), respectively. The KLH conjugate was used to produce polyclonal antibodies in rabbits. A competitive direct enzyme immunoassay (EIA) for tenuazonic acid was established, which was moderately sensitive for tenuazonic acid [50% inhibition concentration (IC(50)): 320 ± 130 ng/mL] but strongly reacted with tenuazonic acid acetate (IC(50): 23.3 ± 7.5 ng/mL). Therefore, an optimized EIA protocol was established, which employed acetylation of standard and sample extract solutions. The mean standard curve detection limit (IC(30)) for tenuazonic acid acetate was 5.4 ± 2.0 ng/mL, enabling detection limits for tenuazonic acid in apple and tomato products of 25-50 ng/g (150 ng/g in tomato paste). Recoveries in a concentration range of 50-2000 ng/g were 60-130% in apple juice and tomato juice and 40-150% in other tomato products. Tenuazonic acid was detected in apple juice and tomato products from German retail shops at levels of 50-200 ng/g. In conclusion, this novel EIA for tenuazonic acid could be useful within a screening program for Alternaria mycotoxins in food.  相似文献   

10.
Hybridomas secreting a monoclonal antibody (mAb) against the herbicide chlorimuron-ethyl (CE) were produced by fusing the mouse myeloma cell line (SP2/0) with splenocytes from a mouse immunized against the conjugate of the sulfonamide moiety of CE and bovine serum albumin (BSA). The mAb, designated 1F5C5A10, had very weak affinity with metsulfuron, ethametsulfuron, pyrazosulfuron, bensulfuron, and chlorsulfuron. Two mAb-based indirect competitive enzyme-linked immunosorbent assays (icELISA) were developed. A conventional icELISA (icELISA-I) showed a concentration of half-maximum inhibition (IC(50)) of 11.6 ng/mL with a dynamic range of 1.6-84 ng/mL. A simplified icELISA (icELISA-II) had an IC(50) of 28.7 ng/mL and a dynamic range of 2.2-372 ng/mL. The two assays were tested on spiked water and soil samples. CE (1-500 ng/mL) fortified in water samples could be analyzed directly without any sample preparation by both immunoassays with an average recovery between 74 and 114%. icELISA-II, but not icELISA-I, was able to accurately analyze the herbicide residues in the crude soil extracts with recoveries between 99 and 129% without obvious matrix effects due to its lesser amount of sample used. In contrast to icELISA-I, icELISA-II is more convenient, whereas it consumes more reagents of coating antigen and goat anti-mouse IgG-peroxidase.  相似文献   

11.
Two enzyme-linked immunosorbent assays (ELISA) for the insecticide azinphos-methyl have been optimized and characterized. Both ELISAs are based on monoclonal antibodies produced from an immunogen with a hapten containing a phthalimido moiety and on protein conjugates of heterologous ligands containing a 1,2,3-benzotriazine group. Assay I was performed in the conjugate-coated ELISA format and assay II in the antibody-coated format. Several physicochemical factors (ionic strength, pH, incubation times, and Tween 20 and BSA concentrations) that influence assay performance were studied and optimized. Regarding specificity, both monoclonal immunoassays highly cross-reacted with azinphos-ethyl and phosmet. Finally, both assays were applied to the analysis of azinphos-methyl in spiked real water samples. For assay I the sensitivity, estimated as the I(50) value, was 0.40 nM, with a practical working range between 0.10 and 1.75 ng/mL and a limit of detection of 0.05 ng/mL. For assay II the sensitivity was 1.01 nM, with a practical working range between 0.32 and 2.54 ng/mL and a limit of detection of 0.08 ng/mL.  相似文献   

12.
Using a highly specific antibody against aflatoxin M1, a radioimmunoassay (RIA) and an enzyme-linked immunosorbent assay (ELISA) were developed for the quantitation of M1 in milk. RIA was sensitive in the range of 5-50 ng per assay but was subject to interference by whole milk. Extraction and cleanup were therefore necessary for the detection of M1 in milk at 0.5 ng/mL. An ELISA procedure was developed by using an aflatoxin M1-carboxymethyl-horseradish peroxidase conjugate as the ligand. Competitive assays revealed that this system was relatively more sensitive for M1 than for B1, and had a much lower degree of cross-reactivity for aflatoxins B2, G1, G2, B2a, and aflatoxicol. As low as 0.25 ng M1/mL in artificially contaminated milk (raw, whole, skim) could be detected by ELISA in 3 h without extraction or cleanup. Because of its simplicity, sensitivity, and specificity, ELISA is the preferred method for monitoring aflatoxin M1 in milk.  相似文献   

13.
For development of an indirect competitive enzyme-linked immunosorbent assay (ELISA) for the organophosphorus insecticide fenitrothion, the specificity of the antiserum R-3 generated with the bifunctional hapten, LysMNPA (2-[[[(3-methyl-4-nitrophenyl)oxy]methylcarbonyl]amino]-6-(2,4-dinitrophenyl)aminohexanoic acid) and the application to the residual analysis of some water samples were evaluated. At optimized ELISA conditions, the quantitative working range was from 1 to 39 ng/mL with a limit of detection of 0.3 ng/mL and an IC(50) value of 6 ng/mL. Cross-reactivity to structurally similar organophosphorus compounds and related chemicals was determined. The antiserum R-3 showed significant cross-reactivity with fenitrooxon and 3-methyl-4-nitrophenol, which have a 3-methyl-4-nitrophenoxy group as common structures, but showed relatively low cross-reactivity with other compounds. Each water sample (river water, tap water, purified water, and bottled water) had a matrix effect and was investigated by adding Tween 20 in the assay buffer. These four kinds of water samples were fortified with fenitrothion at several concentration levels and were directly analyzed with only dilution with an equal volume of antiserum solution. The mean recovery was 105.9%, and the mean coefficient of variation was 10.9%. The results suggested that the developed ELISA would be very suitable for a preliminary screening for fenitrothion in water samples at such low levels.  相似文献   

14.
Highly sensitive enzyme-linked immunoassays for chlorpyrifos, one of the most applied insecticides, are presented. Several haptens were synthesized for immunoreagent production and ELISA development. The best immunoassays obtained are based on an indirect coated-plate immunoassay format. Two assays were optimized; one shows a limit of detection of 0.3 ng L(-1), an I50 of 271 ng L(-1), and a dynamic range between 4 and 16 474 ng L(-1). The other one has a limit of detection of 0.07 ng L(-1), an I50 of 7 ng L(-1), and a dynamic range between 0.4 and 302 ng L(-1). The assays were used to quantify chlorpyrifos in olive oil using a simple and rapid sample extraction procedure. The good recoveries achieved in both assays (109% mean value) and the agreement with values given by the GC reference method (110% mean value) indicate their potential for either screening or laboratory quantification.  相似文献   

15.
A selective and fast method for the quantitative determination of 2,4,6-trichloroanisole (TCA) and 2,4,6-tribromoanisole (TBA) in wine was developed. Microextraction in packed syringe (MEPS) was optimized for the extraction and preconcentration of the analytes using extremely small volume samples (0.1-1 mL). For GC-EI-MS, the limit of detection (LOD) for red and white wine was in the range 0.17-0.49 microg L(-1) for TCA and TBA. In addition to GC-EI-MS both GC-NCI-MS and GC-HRMS were used to further improve both selectivity and sensitivity. The lowest LODs were achieved using GC-HRMS in the EI mode. In red and white wine samples the LODs were between 0.22-0.75 ng L(-1) for TCA and TBA. The reproducibility and linearity for the GC-HRMS method was good, with RSD-values of 4-10% for spiked red wine samples at 1 ng L(-1) and linearity with R (2) > 0.962 over a concentration range of 1 to 100 ng L(-1).  相似文献   

16.
An indirect competitive enzyme immunoassay for hen egg white lysozyme (HEL) used as a food additive was investigated. Anti-HEL antibodies were obtained from B10A mouse ascites immunized by intraperitoneal injection of HEL. HEL samples to be assayed were extracted from foods with 1% gelatin in borate buffer. Goat anti-mouse IgG (H+L)-peroxidase complex was used as a second antibody, and 3,3',5,5'-tetramethylbenzidine was used as a substrate for the peroxidase. The working range for quantitative analysis was 1-50 ng/mL, because in this range the binding inhibition curve of anti-HEL antibodies to HEL-coated plates by HEL was linear. Even after losing the lysozyme activity by heat treatment, HEL could be detected by indirect competitive enzyme immunoassay. Recoveries of HEL by this assay were greater than 85% for Japanese noodles and Japanese traditional-style confectioneries, 53-95% for Miso and cooked beans, and 30-85% for fried fish pastes. HEL contents of 55 commercial foods were determined; HEL was detected in 19 samples in the range 25-20,000 ng/g. HEL as a food additive was detected more frequently in plant-derived foods than in foods of animal origin.  相似文献   

17.
To develop a competitive indirect enzyme-linked immunosorbent assay based on polyclonal antibodies for the detection of the sulfonylurea herbicide bensulfuron-methyl, seven structurally related haptens were synthesized. Four of them mimicking the target analyte were conjugated to keyhole limpet hemocyanin by the N-hydroxysuccinimide activated ester method to use as immunogens, and all of them were conjugated to bovine serum albumin to use as plate-coating antigens. Polyclonal antibodies raised in rabbits and the coating antigens were screened and selected for the assay in simple homologous and heterologous ELISA formats. Three sensitive heterologous ELISAs were selected and optimized, showing the average IC(50) values of bensulfuron-methyl as low as 0.17, 0.09, and 0.09 ng/mL, the detection ranges of 0.04-0.60, 0.01-0.60, and 0.04-0.25 ng/mL, and the lowest detection limits of 0.03, 0.002, and 0.03 ng/mL, respectively. The cross-reactivities of other sulfonylurea herbicides and metabolites of bensulfuron-methyl to the antibodies were less than 15% in the two assays. Recoveries from the analyte-fortified water samples in assay I were in the range of 81-125% by simple dilution. The correlation between the ELISA and HPLC was 0.999 (n = 15) with a slope of 1.37 in the analysis of groundwater samples fortified with bensulfuron-methyl. The results obtained strongly indicate that the ELISA can be a highly sensitive and convenient tool for detecting bensulfuron-methyl residues in agricultural and environmental samples.  相似文献   

18.
An improved liquid phase microextraction (LPME) technique has been developed. As part of this technique, analytes were extracted into an extractant microdrop which was laid on the cone-shaped bottom of a PCR tube (polychloroprene rubber tube) but not at the needle tip of a microsyringe, and the sample vial and PCR tube were horizontally placed so that the extractant was not affected by the force of vertical orientation (gravity and floating force). The stability of the extractant microdrop increased greatly, and the selection of extractant was extended. In this work, flumetsulam and its two analogous herbicides were chosen as model analytes in investigating the feasibility of the new pretreatment method by coupling it to high-performance liquid chromatography (HPLC). Under the optimized experimental conditions, the linear range and the limits of detection (S/N = 3) were 0.01-5 microg/mL (r = 0.9997) and 0.8 ng/mL for flumetsulam, 0.002-5 microg/mL (r = 0.9994) and 0.5 ng/mL for analogue 1, and 0.002-1 microg/mL (r = 0.9993) and 0.5 ng/mL for analog 2, respectively. The inter- and intraday reproducibilities (RSD) were below 5.3 and 4.5%, respectively. Good recoveries that ranged from 79.4 to 115.0% were obtained in the analysis of real soil samples. The extraction efficiency of the improved method was 4-8 times higher than that of the conventional liquid phase microextraction method. The novel, simple, rapid, sensitive technique is very suitable for extraction of apolar and medium polar analyte in complex environmental samples.  相似文献   

19.
A monoclonal antibody (Mab) was produced by using the kanamycin-glutaraldehyde-bovine serum albumin (Kan-GDA-BSA) conjugate as the immunogen. The anti-Kan Mab exhibited high cross-reactivity with tobramycin (Tob) and slight or negligible cross-reactivity with other aminoglycosides. The specificity and cross-reactivity of this Mab are discussed regarding the three-dimensional, computer-generated molecular models of the aminoglycosides. Using this Mab, a rapid enzyme-linked immunosorbent assay (ELISA) and a colloidal gold-based strip test for Kan and Tob were developed. The rapid ELISA showed a 50% inhibition value (IC 50) of 0.83 ng/mL for Kan and 0.89 ng/mL for Tob with the analysis time less than 40 min, and the recoveries from spiked swine tissues at levels of 25-200 microg/kg ranged from 52% to 96% for Kan and 61% to 86% for Tob. In contrast, the strip test for Kan or Tob had a visual detection limit of 5 ng/mL in PBS, 50 microg/kg in meat or liver, and 100 microg/kg in kidney, and the results can be judged within 5-10 min. Observed positive samples judged by the strip test can be further quantitated by ELISA, hence the two assays can complement each other for rapid detection of residual Kan and Tob in swine tissues. Moreover, physical-chemical factors that affected the ELISA and strip test performance were also investigated. The effect of pH and antibody amount for gold-antibody conjugation on the strip test sensitivity was determined followed by a theoretical explanation of the effects.  相似文献   

20.
To detect the organophosphorus (OP) pesticide pirimiphos-methyl in grain samples, a monoclonal antibody-based indirect competitive enzyme-linked immunosorbent assay (IC-ELISA) was developed and optimized. By the active esters method, pirimiphos-methyl hapten A was conjugated to keyhole limpet hemocyanin to be used as the immunogen for the production of monoclonal antibodies, and pirimiphos-methyl hapten B was conjugated to ovalbumin to be used as coating antigen. By using the monoclonal antibody and the coating antigen, an IC-ELISA has been developed. Under the established optimized conditions, the IC-ELISA showed an IC50 of 4.2 ng/mL with a detection limit of 0.07 ng/mL. The IC-ELISA showed negligible cross-reactivity with other OP pesticides except with pirimiphos-ethyl. Recoveries of pirimiphos-methyl from spiked grain samples ranged from 83 to 96%.  相似文献   