The optical sensor for "tea catechins" was built by immobilizing 2,2'-(1,4-phenylenedivinylene)bis-8-hydroxyquinoline (PBHQ) on TiO? nanoparticles (NPs). The sensor worked by "indophenol blue" dye formation on PBHQ-immobilized TiO? NPs as a result of p-aminophenol (PAP) autoxidation with dissolved O? at pH 10. Among quercetin, rutin, naringenin, naringin, gallic acid, caffeic acid, ferulic acid, p-coumaric acid, catechin, epicatechin, epicatechin gallate, epigallocatechin, epigallocatechin gallate, and trolox, only catechin group antioxidants delayed the color formation on NPs, as measured by the reflectance signal at 710 nm. For quantitative analysis, reflectance signal versus time was recorded, and the difference between the areas under curve (ΔAUC) in the presence and absence of catechin was correlated (r = 0.98) to catechin concentration. The selectivity of the sensor for catechins was shown in tea infusions compared to other plant extracts and was ascribed to the nonplanar structure of catechin interfering with the formation of perfectly conjugated indophenol blue on TiO? surface.  相似文献   

2.
A sensitive method has been developed for the simultaneous determination of residues of 25 β?-agonists and 23 β-blockers in animal foods by high-performance liquid chromatography coupled with linear ion trap mass spectrometry (HPLC-LIT-MS). This method is based on a new procedure of hydrolysis and extraction by 5% trichloracetic acid, and then cleaned up by mixed strong cation exchange (MCX) cartridges coupled with a novelty cleanup step by methanol. Methanol and 0.1% formic acid were used as mobile phases for gradient elution, while a Supelco Ascentis Express Rp-Amide column was used for LC separation. ESI positive ion scan mode was used with consecutive reaction monitoring (CRM, MS3). Nine β?-agonists labeled by the deuterium isotope were used as internal standards for quantification. The linear ranges of 48 analytes were from 5 to 200 μg/L; the coefficient of correlation was not less than 0.995. Blank pork muscle, blank liver, and blank kidney were selected as representative matrix for spiked standard recovery test. The recoveries of each compound were in the range of 46.6-118.9%, and the relative standard deviations were in the range of 1.9-28.2%. Decision limits (CCα, α = 0.01) of 48 analytes in muscles, liver, and kidney samples ranged from 0.05 to 0.49 μg/kg, and the detection capability (CCβ, β = 0.05) ranged from 0.13 to 1.64 μg/kg. This method was successfully applied to 110 real animal origin food samples including meat, liver, and kidney of pig and chicken samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号