首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Strobilurin fungicides have been increasingly used for fungus pest control since they were introduced in 1996. For pesticide residue detection, immunoassays constitute nowadays a valuable approach. This paper describes the synthesis of functionalized haptens of kresoxim-methyl, the production of monoclonal antibodies, and the development of enzyme-linked immunosorbent assays. On the one hand, a two-step conjugate-coated immunoassay was optimized using extended or short incubation times, with limits of detection of 0.4 ng/mL for the extended assay and 0.3 ng/mL for the rapid assay. On the other hand, an immunoassay was optimized following a procedure consisting of just one incubation step. This one-step assay had a limit of detection of 0.4 ng/mL. All of these assays showed a similar performance, with sensitivities well below common maximum residue limits for this pesticide (50 microg/kg) and lower than the detection limits of the usual chromatographic detection methods.  相似文献   

2.
Two enzyme-linked immunosorbent assays (ELISA) for the insecticide azinphos-methyl have been optimized and characterized. Both ELISAs are based on monoclonal antibodies produced from an immunogen with a hapten containing a phthalimido moiety and on protein conjugates of heterologous ligands containing a 1,2,3-benzotriazine group. Assay I was performed in the conjugate-coated ELISA format and assay II in the antibody-coated format. Several physicochemical factors (ionic strength, pH, incubation times, and Tween 20 and BSA concentrations) that influence assay performance were studied and optimized. Regarding specificity, both monoclonal immunoassays highly cross-reacted with azinphos-ethyl and phosmet. Finally, both assays were applied to the analysis of azinphos-methyl in spiked real water samples. For assay I the sensitivity, estimated as the I(50) value, was 0.40 nM, with a practical working range between 0.10 and 1.75 ng/mL and a limit of detection of 0.05 ng/mL. For assay II the sensitivity was 1.01 nM, with a practical working range between 0.32 and 2.54 ng/mL and a limit of detection of 0.08 ng/mL.  相似文献   

3.
Staphylococcus aureus enterotoxin B (SEB) is a highly heat resistant enteric toxin with a potential as a biothreat agent. A sensitive method for the detection of staphylococcal enterotoxins is needed for food safety and food defense monitoring. The objectives of this research were to develop a competitive fluorescent immunoassay with detection of SEB below toxic levels of 1 ng/mL and to minimize sample preparation. Anti-SEB was immobilized onto carboxylated polystyrene microparticles, and SEB was labeled with fluorescein isothiocyanate (FITC). The concentrations of these reagents were optimized for the detection of SEB below 1 part per billion (1 ng/mL), and other assay conditions (sample volumes and incubation periods) were optimized. Drinking water and milk samples were spiked with 0.125-10 ng/mL SEB and were equilibrated overnight prior to analysis. The water and milk samples were directly analyzed, but heating the milk samples for 10 min at 90 degrees C improved the assay performance. SEB in samples bound with the anti-SEB linked to the latex followed by the competitive binding of SEB-FITC tracer. The excess, unbound tracer was separated by centrifugation, and the fluorescence density of the supernatant was measured. SEB was detected at levels as low as 0.125 ng/mL in drinking water and 0.5 ng/mL in whole milk. This fluorescent latex particle immunoassay will be utilized for the detection of SEB in various foods matrices.  相似文献   

4.
Competitive direct enzyme-linked immunosorbent assay (ELISA) and the immunochromatographic assay were developed using a monoclonal antibody to detect gentamicin in the animal plasma and milk. No cross-reactivity of the antibody was observed with other aminoglycosides based on competitive direct ELISA, indicating that the antibody is highly specific for gentamicin. On the basis of the standard curves, the detection limits were determined to be 0.9 ng/mL in phosphate-buffered saline (PBS), 1.0 ng/mL in plasma, and 0.5 ng/mL in milk, respectively. Recoveries of gentamicin from spiked plasma and milk at levels of 25-100 ng/mL ranged from 85 to 112%. The concentration of intramuscularly injected gentamicin was successfully monitored in the rabbit plasma through competitive direct ELISA. The detection limits were estimated to be about 6 ng/mL of gentamicin in PBS, plasma, and milk using the colloidal gold-based immunochromatographic assay, which is suitable for the simple screening of gentamicin residues in the veterinary field. Observed positives can be confirmed using a more sensitive laboratory method such as competitive direct ELISA. Therefore, the assays developed in this study could complement each other as well as veterinary field and laboratory findings.  相似文献   

5.
To develop an enzyme-linked immunosorbent assay for the fungicide fenarimol, two synthesized haptens, haptens-1 and -2, and the purchased 4,4'-DDA were conjugated to carrier proteins (BSA, KLH, and OVA). Polyclonal antibodies raised against hapten-1,2-KLH conjugates in rabbits and the coating antigens of hapten-1,2-BSA conjugates, hapten-2-OVA conjugate, and 4,4'-DDA-BSA conjugate were screened and selected for the homologous and/or heterologous ELISA formats. Two competitive indirect ELISAs were selected: assays I and II. The optimized ciELISAs of assays I and II showed average IC(50) values of fenarimol of 5.4 and 9.4 ng/mL, detection ranges of 1.1-25.9 and 1.1-82.7 ng/mL, and lowest detection limits of 0.3 and 0.3 ng/mL, respectively. The cross-reactivities with several structurally related compounds indicated the importance of the steric fitness in the antigen-antibody interaction. Recoveries of fenarimol from apple and pear samples spiked with the analyte by assay I were in the range of 93-113% by simple extraction, concentration, and dilution. This assay could be a convenient and supplemental analytical tool for monitoring fenarimol residues in environmental and agricultural samples.  相似文献   

6.
To produce monoclonal antibodies (MAbs) to the pesticide carbofuran, three compounds with carboxylic spacer arms of different lengths introduced at the carbamate group of the analyte structure were synthesized, conjugated to proteins, and used as immunizing haptens in mice. MAbs were subsequently characterized for affinity and specificity in the conjugate-coated format and in the antibody-coated format using newly synthesized compounds as heterologous assay haptens. Depending on the immunoreagent combination and assay format, competitive assays with I(50) values in the 1.2-10.2 nM (0.27-2.27 ng/mL) range were obtained. LIB-BFNB67 MAb in combination with the hapten BFNH, coupled either to horseradish peroxidase or to ovalbumin, was used to develop a direct and an indirect enzyme-linked immunosorbent assay, respectively. Optimized immunoassays displayed very similar analytical characteristics, with an I(50) value around 0.7 ng/mL and a limit of detection around 0.08 ng/mL. Both immunoassays were able to tolerate the presence of methanol up to a 15% concentration. Compounds very similar in structure to carbofuran (benfuracarb, furathiocarb, bendiocarb, and carbofuran-hydroxy) exhibited cross-reactivity values in the 18-37% range, but major N-methylcarbamate pesticides were not recognized by the MAb. These immunoassays should reasonably allow the rapid, low-cost, and sensitive determination of carbofuran in food, in soils, and in the environment at levels of regulatory and practical importance.  相似文献   

7.
Two competitive immunoassays, a laboratory assay based on microwell plates and a field test based on the use of polystyrene tubes, have been developed for the quantification of thiram in lettuces. Concerning the laboratory assay, the calibration curve for thiram had a linear range of 11 to 90 ng/mL and a detection limit of 5 ng/mL. Precision of the assay presented coefficient of variation values <9% and the recovery of thiram from lettuce averaged 89% across the range of the immunoassay method using 30 min extraction with water/acetone (50:50, v/v). The tube-based method was developed in order that an extract of lettuce, containing thiram at the MRL (8 ppm), would be found on the linear part of the standard curve. The calibration curve for thiram has a linear range of 100 to 800 ng/mL (1.39 to 11.1 ppm in lettuce) and a detection limit of 40 ng/mL.  相似文献   

8.
9.
Immunoassays for 2,4,6-trichloroanisol (TCA) have been evaluated. The assays were developed after raising antibodies against three different immunizing haptens (1). Lack of reproducibility has been one of the main problems of these assays. Precision was worse on these assays, reaching lower limits of detection. The high lipophilicity of TCA and its, consequently, low water solubility have been found to be the major cause of this problem. A reliable microplate-based enzyme-linked immunosorbent assay (ELISA) has been set after consideration of the TCA physicochemical features and evaluation of important parameters affecting immunoassay performance. The immunoassay uses As78 (developed against hapten B-KLH) and C9-OVA as the coating antigen. The selectivity is high although the brominated analogue 2,4,6-TBA is also recognized. In buffered media containing 7% ethanol, the resulting assay shows a good accuracy with an IC(50) value of 0.53 microgram L(-)(1) and a limit of detection of 0.044 microgram L(-)(1). Red and white wine samples caused important interferences in the immunoassay demonstrating the necessity of a cleanup procedure prior to the ELISA.  相似文献   

10.
To develop a competitive indirect enzyme-linked immunosorbent assay based on polyclonal antibodies for the detection of the sulfonylurea herbicide bensulfuron-methyl, seven structurally related haptens were synthesized. Four of them mimicking the target analyte were conjugated to keyhole limpet hemocyanin by the N-hydroxysuccinimide activated ester method to use as immunogens, and all of them were conjugated to bovine serum albumin to use as plate-coating antigens. Polyclonal antibodies raised in rabbits and the coating antigens were screened and selected for the assay in simple homologous and heterologous ELISA formats. Three sensitive heterologous ELISAs were selected and optimized, showing the average IC(50) values of bensulfuron-methyl as low as 0.17, 0.09, and 0.09 ng/mL, the detection ranges of 0.04-0.60, 0.01-0.60, and 0.04-0.25 ng/mL, and the lowest detection limits of 0.03, 0.002, and 0.03 ng/mL, respectively. The cross-reactivities of other sulfonylurea herbicides and metabolites of bensulfuron-methyl to the antibodies were less than 15% in the two assays. Recoveries from the analyte-fortified water samples in assay I were in the range of 81-125% by simple dilution. The correlation between the ELISA and HPLC was 0.999 (n = 15) with a slope of 1.37 in the analysis of groundwater samples fortified with bensulfuron-methyl. The results obtained strongly indicate that the ELISA can be a highly sensitive and convenient tool for detecting bensulfuron-methyl residues in agricultural and environmental samples.  相似文献   

11.
Monoclonal antibodies (MAbs) to the pesticide propoxur were produced from haptens with carboxylic spacer arms of different lengths introduced at the carbamate group of the analyte structure. MAbs were subsequently characterized in the conjugate-coated format using these immunizing haptens and newly synthesized compounds as homologous and heterologous assay conjugates, respectively. Appropriate combinations of immunoreagents resulted in competitive enzyme immunoassays (ELISA) with I(50) values in the low nanomolar range (6.5-17.9 nM). A modification of the conjugate-coated format consisting of the simultaneous incubation of the MAb and the peroxidase-labeled secondary antibody in the presence of the analyte resulted in an assay with an I(50) value of 4.4 nM. This one-step conjugate-coated ELISA format is as simple and fast as the antibody-coated format but without the need of synthesizing enzyme-hapten conjugates. Major N-methylcarbamate pesticides were not recognized by the MAb. This immunoassay should reasonably allow the rapid, low-cost, and sensitive determination of propoxur in food, soils, and the environment at levels of regulatory and practical importance.  相似文献   

12.
In this paper, a new monoclonal antibody (Mab) against sulfamethoxypyridazine (SMP) was produced, and a fluorescence polarization immunoassay (FPIA) based on the produced Mab was developed and optimized for the qualitative screening analysis of SMP. The Mab was raised from mice immunized with SMP linked to bovine serum albumin (BSA) by carbodiimide activated ester formation, using a succinic anhydride spacer molecule between SMP and BSA. Fluorescein labeled sulfachloropyridazine (SCP) and SMP (tracer) were synthesized and purified by thin layer chromatography (TLC). The developed screening FPIA method can tolerate up to 20% methanol, and satisfactory assay sensitivity can be obtained between pH 4 and pH 8 and at lower salt concentration. The anti-SMP Mab exhibited a high cross-reactivity with SCP. The effect of the tracer structure on the analytical characteristic of the determination and on antigen-antibody binding constants was studied. The limits of detection (LOD) were 0.7 ng/mL for SMP and 0.25 ng/mL for SCP in buffer, respectively, whereas negligible cross-reactivities were exhibited by related sulfonamides. Analysis of SMP and SCP-fortified milk samples by the FPIA showed average recoveries from 60 to 145%.  相似文献   

13.
The Alternaria mycotoxin tenuazonic acid was derivatized with succinic anhydride and conjugated to keyhole limpet hemocyanin (KLH) and to horseradish peroxidase (HRP), respectively. The KLH conjugate was used to produce polyclonal antibodies in rabbits. A competitive direct enzyme immunoassay (EIA) for tenuazonic acid was established, which was moderately sensitive for tenuazonic acid [50% inhibition concentration (IC(50)): 320 ± 130 ng/mL] but strongly reacted with tenuazonic acid acetate (IC(50): 23.3 ± 7.5 ng/mL). Therefore, an optimized EIA protocol was established, which employed acetylation of standard and sample extract solutions. The mean standard curve detection limit (IC(30)) for tenuazonic acid acetate was 5.4 ± 2.0 ng/mL, enabling detection limits for tenuazonic acid in apple and tomato products of 25-50 ng/g (150 ng/g in tomato paste). Recoveries in a concentration range of 50-2000 ng/g were 60-130% in apple juice and tomato juice and 40-150% in other tomato products. Tenuazonic acid was detected in apple juice and tomato products from German retail shops at levels of 50-200 ng/g. In conclusion, this novel EIA for tenuazonic acid could be useful within a screening program for Alternaria mycotoxins in food.  相似文献   

14.
Strobilurin fungicides are nowadays among the most important fungicides in the market of active agrochemicals. Pyraclostrobin, which belongs to the last generation of this family of molecules, shows a broader antifungal activity spectrum and higher efficiency and security profiles than previous fungicides. This paper describes the synthesis of functionalized haptens, the production of monoclonal antibodies, and the development of enzyme-linked immunosorbent assays (ELISA) for the detection of pyraclostrobin. A conformational analysis of hapten structure was performed, which provided relevant data concerning the length of the spacer arm. A very useful strategy has been followed for the screening of hybridomas, leading to the selection of a panel of high-affinity monoclonal antibodies to pyraclostrobin. Moreover, different immunoassays have been characterized using the conjugate-coated indirect ELISA format, and limits of detection below 0.1 microg/L have been obtained. Also, a simplified one-step procedure has been carried out with two indirect assays. Finally, these results have been compared with the performance of the same antibodies in the antibody-coated direct ELISA format.  相似文献   

15.
A direct competitive chemiluminescent enzyme-linked immunosorbent assay (CL-ELISA) for the determination of ochratoxin A (OTA) was developed using soybean peroxidase (SbP) in combination with 3-(10'-phenothiazinyl)propane-1-sulfonate (SPTZ) and 4-morpholinopyridine (MORPH) as a detection system. By varying the concentrations of the capture monoclonal anti-OTA antibody, a conjugate of OTA with SbP, and the composition of blocking buffers, the conditions of the immunoassay were optimized. Advantages of CL-ELISA were demonstrated by comparison with ELISA with colorimetric detection (COL-ELISA). The values of IC??, IC??, and working range (IC??-IC??) for CL-ELISA and COL-ELISA were 0.01, 0.08, and 0.02-0.3 ng/mL and 0.08, 0.58, and 0.17-2.2 ng/mL, respectively. The recovery values of CL-ELISA from three soybean spiked samples with OTA concentrations of 0.07, 0.1, and 0.15 ng/mL ranged from 72 to 125%. Determination of OTA in 21 various agricultural commodities showed that OTA in 8 examined samples was not detected by COL-ELISA. Furthermore, it was found that in 4 of these 8 samples the developed CL-ELISA determined OTA at levels from 0.96 to 4.64 ng/g.  相似文献   

16.
Highly sensitive enzyme-linked immunoassays for chlorpyrifos, one of the most applied insecticides, are presented. Several haptens were synthesized for immunoreagent production and ELISA development. The best immunoassays obtained are based on an indirect coated-plate immunoassay format. Two assays were optimized; one shows a limit of detection of 0.3 ng L(-1), an I50 of 271 ng L(-1), and a dynamic range between 4 and 16 474 ng L(-1). The other one has a limit of detection of 0.07 ng L(-1), an I50 of 7 ng L(-1), and a dynamic range between 0.4 and 302 ng L(-1). The assays were used to quantify chlorpyrifos in olive oil using a simple and rapid sample extraction procedure. The good recoveries achieved in both assays (109% mean value) and the agreement with values given by the GC reference method (110% mean value) indicate their potential for either screening or laboratory quantification.  相似文献   

17.
A rapid and simple immunochemical method was developed for the assessment of the creatine kinase (MM) isoenzyme [CK(MM)], a protein marker linked with animal welfare and meat quality. The one-step time-resolved immunofluorometric assay produced quantitative results from serum or whole blood samples in 20 min. The analytical limit of detection (mean + 2s) for the immunoassay was 17 ng/mL (n = 6), and the functional limit of detection for the analysis of porcine whole blood samples was 426 ng/mL (n = 24). The working range of the method was linear up to 50 micro g/mL, and the within-assay precision varied between 2.1 and 10.9%. The analysis of porcine serum samples showed that the results from the immunoassay method and colorimetric CK enzyme activity determination were highly correlated (r(2) = 0.965, n = 17, p < 0.001). The practicability of the assay was demonstrated by the analysis of 300 porcine whole blood samples in a slaughterhouse environment.  相似文献   

18.
Cyprodinil is an anilinopyrimidine fungicide applied worldwide for the prevention and treatment of highly destructive plant diseases in a large variety of crops, including cereals, fruits, and vegetables. This paper describes the development of the first reported immunoassays for cyprodinil. Two original haptens have been synthesized and conjugated to different carrier proteins, and polyclonal antibodies have been produced. Moreover, competitive enzyme-linked immunosorbent assays have been developed and characterized for the analysis of this widely used pesticide. The influence of organic solvents and buffer conditions over the assay analytical parameters was studied. The IC(50) values of the optimized immunoassays were 1.6 and 2.8 ng/mL for the direct and indirect formats, respectively. Quantitative recoveries were found using spiked apple and grape juice samples after a simple direct dilution, and a limit of quantification of 20 ng/mL for both fruit matrices was achieved. These immunoreagents could be very valuable for the sensitive, straightforward, and rapid monitoring of cyprodinil residues in foodstuffs.  相似文献   

19.
Membrane-based competitive immunoassays using gold particles and horseradish peroxidase (HRP) as tracers in flow-through and lateral-flow formats for multianalysis of carbaryl and endosulfan were developed. For gold-based immunoassay, membrane strips were coated with goat anti-rabbit IgG (control line) and carbaryl hapten-ovalbumin (OVA) and endosulfan hapten-OVA (test lines). The visual detection limits for carbaryl and endosulfan were 100 and 10 microg/L in gold-based assays, respectively. For immunoassay using HRP as tracer, anti-carbaryl and anti-endosulfan antibodies were separately coated on the membrane as test lines, and the visual detection limits were 10 microg/L for carbaryl and 1 microg/L for endosulfan. The developed assays used gold particles and HRP as labels, respectively; 10 times enhancement in the visual detection limit using HRP label was obtained in the study. Matrix interference was eliminated by appropriate dilution of sample extracts with buffer. For the validation of the multianalyte assay, the samples were screened by multianalyte gold-based assay and confirmed by HPLC for carbaryl determination and by GC for endosulfan determination. The results of multianalyte gold-based flow-through assay for the determination of carbaryl and endosulfan were in good agreement with the results of instrumental analysis (HPLC with ultraviolet detection and GC with electron capture detection). The developed multianalyte immunoassays for which the results were interpreted visually can be used as convenient qualitative tools for on-site rapid screening of carbaryl and endosulfan simultaneously in agricultural products.  相似文献   

20.
A rapid antibody-based detection system has been developed for the presence of free trenbolone in bovine samples. Polyclonal antibodies were produced that showed specificity toward epitopes located around the steroidal A-ring of the trenbolone molecule. These antibodies were shown to have little or no recognition for many closely related compounds. The antibodies were utilized as the specific biorecognition molecules in competitive and inhibitive enzyme-linked immunosorbent assay systems. While both assays were able to detect low nanogram concentrations of trenbolone in bovine bile, the competitive format was more sensitive (2.41 vs 17.15 ng/mL for TRAb2 and 3.31 vs 30.73 ng/mL for TRAb1). This format was also more accurate and the data produced by this assay fitted more closely to the four parameter equation used to calculate the standard curve. This was a common finding with both of the polyclonal antibodies, suggesting that this was a characteristic of the format used.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号