To counteract capacitive current and resume power system, the neutral point of 35 kV power system at the mountainous area is grounding through the arc winding widely. In fact, there is great difficult in selecting the arc winding to satisfy the requirement of system. In a 35 kV power system which neutral point is grounding through the arc winding, the capacitance current are measured in site when a single-phase is grounding. From the measure data, the imbalance of three-phase voltage whether the arc winding exist or not and the operating situation of arc winding are discussed, and bring forward an attentive problem about operation of arc winding and decrease of lightning outage rates.  相似文献   

2.
The unbalanced nature of 35 kV distribution system due to capacity values is difficult in neutral operation, which can not meet the demand of voltage balance in static state and arc distinct in fault. This paper proposes a new neutral operation as neutral insulation in static state and resonance grounding in fault , along with EMTP simulation acts. Simulation indicates that new neutral operation method can improve lightning withstand level and decrease trip-out rate of grids.  相似文献   

3.
The aufhors calculate and analyze the arcing grounding overvoltage of 10 kV power network in case of neutral ungrounded and grounding through nonlinear resistance using EMTP, with a actual 10 kV power network of a substation in Guizhou province as an example. The emulational calculation results show that the grounding method which grounds through nonlinear resisitance has the advantages of the other two methods, can better limit the arcing grounding overvoltage and can not stop the power supply .even one phase is grounded by fault, so it can ensure the security of the power networkg supply . the network neutral grounding through nonlinear resistance needs more deep study and analysis as a new network neutral grounding mehtod.  相似文献   

4.
Research on Lightning Intruded Wave for 500 kV Substations   总被引:1,自引:0,他引:1  
The study on overvoltage for 500 kV substation caused by lightning intruded wave is presented. In this paper, we calculate by using electromagnetic transient program (EMTP) and combine substation with incoming lines ,so some influence factors can be considered such as impulse voltage second characteristic of insulator strings, lightning stroke point on the incoming lines and impulse grounding resistance of towers. The results show that the method is close to the practice and some factors of incoming lines are important to overvoltage.  相似文献   

5.
In order to resolve the hazard of biofouling and scale in circulating cooling water system of power stations, this paper takes the lead in combining high voltage pulses and high frequency pulses for sterilization and descaling process. It analyzes both electromagnetic effects and biochemical effects on sterilizing and descaling process caused by the high voltage pulses and high frequency pulses respectively. The pulse generator is designed according to the requirements of electromagnetic parameters for effective operation. The design and improvement of process chambers are assisted by electromagnetic field simulation technology. Experimental data prove that the system can output high voltage pulse whose maximum peak value reaches 7 kV and high frequency pulse whose maximum peak value reaches 100 V the frequency ranges from 500 kHz to 2 MHz. The rate of sterilization can be as high as 91,and the rate of descaling reaches 71. This system is expected to achieve the standards of industrial water treatment through further research.  相似文献   

6.
It is still a major problem for research on online monitor dielectric dissipation factor of high voltage equipment insulation. In the field, new methods are paid attention by researchers especially. At present, there are no methods achieving the satisfactory measurement results. Based on the voltage and current at their respective zero crossed points, this paper proposes the integral measurement method which can be used to measure the dielectric dissipation factor of high voltage capacitive apparatus. The formula for dielectric dissipation factor angle computation is deduced by theoretical analysis and the computation results are achieved by digital simulation. Meanwhile, this paper explains the effect to measurements by system frequency, content of harmonic and zero-drift and draws the relevant error curves. It also proposes the measures to reduce the integral measurement method presented in this paper,which can convert measurement of small signal into that of big signal and accurately measure dielectric loss of capacitive apparatus. It also possesses great anti jamming ability under strong electromagnetic interference environment. The online measurement system can detect the dielectric dissipation factor of high voltage equipment by the integral measurement method.  相似文献   

7.
To prevent the duty cycle loss of full-bridge converter controlled by the phase-shifting method, a high frequency high voltage X-ray power supply is proposed. It combines full bridge LLC(FB-LLC) series resonant converter with bipolar single-phase symmetrical voltage multiplier. FB-LLC series resonant, high voltage transformer and bipolar single-phase symmetrical voltage multiplier are used in the main circuit. The LLC series resonant circuit and working conditions of soft switch are analyzed. The fundamental harmonic approximation model is established. The parameters of the main circuit are designed. The simulation results show that the output voltage adjusted continuously within 40~120 kV and without duty cycle loss. The X-ray power supply is proposed to achieve a quick rise and low ripple of output voltage. According to the simulation results, the proposed topology is correct and reliable.  相似文献   

8.
The very fast Transient over-voltage generated due to the switchgear in GIS switching off or on is very harmful to transformer insulation. The model presented is a winding hybrid lumped parameter model which combines the branch model based on parallel cables in one turn with grouped-turns model of two discs to efficiently simulate the very fast transient in the coil. Under quasi-stationary electromagnetic field, network topology and element size are derived from the geometry and properties of the transformer, whose inductance and capacitance are assumed to be passive and to have linear characteristics, however which have an inherent feature of a medium, which propagates waves. The formula of parameters are obtained. Based on the built winding model, the voltage gradients between discs and turns are found out, according to the simulation results, the reasonable winding insulation design can be made.  相似文献   

9.
As for the drive of control system in electric vehicles, if the inverter power is supplied by a constant DC-link voltage, there are some disadvantages in the system, such as small utilization of the voltage, big current harmonic distortion of the motor windings. A new strategy for vector control of permanent magnet synchronous motor (PMSM) with variable DC-link voltage is proposed, which is suitable for electric vehicles. According to the reference voltage amplitude of the inverter, the new system uses bidirectional DC/DC converter to adjust the DC-link voltage to improve the performance of the vector control system. At last, the whole system is simulated with MATLAB software. The simulation results show that the new strategy for vector control can increase voltage utilization, decrease torque ripple, improve current waveform effectively and decrease the total harmonic distortion of motor current. The results also verify the effectiveness and feasibility of the new strategy.  相似文献   

10.
When an ignition system operates, conducted interference caused by transient voltage of the primary circuit will impact on the accumulator and the disturbance will travel throughout the vehicle via wiring. The ignition system can disrupt the Electronic Control Unit and the normal operation of other electrical devices. Spark plug gap noise simultaneously produces very strong radiation interference in a vehicle. We analyzed the changes of the ignition coil voltage and current when an ignition switch was turned on and off. A discharged circuit model of spark plug also was set up. The electric field distribution in an automobile was calculated. For these calculations, the high voltage wire was considered to be a unipole antenna. This simulation indicates that using either damped wire or adding spark plug resistance can suppress spark noise effectively.  相似文献   

11.
With theoretic analysis, lab experiment and engineering application, it is indicated that the SZJ grounding system is a new type grounding system which distinctly reduces the grounding impedance of grounding grids, especially of grounding grids in the zones with high-resistivity or grounding grids with scanty area. The design and calculation method for application of SZJ grounding system is also studied.  相似文献   

12.
In order to improve waveform performance of light HVDC system, a lot of switches which operate in high frequency are used, which causes large switching losses and results high cost. A new Buck type voltage source converter(BVSC) is proposed. The new BVSC comprises a dual-buck converter and a three-phase inverter operating in grid frequency. Only two high frequency switches are used, which results good output waveform performance. In order to reduce the high frequency switching losses, a novel improved double-frequency Buck type voltage source converter(DBVSC) is also proposed. An additional dual-Buck converter is added to the BVSC, the added dual-Buck converter deals with the fundamental power that operates in low frequency, and BVSC only deals with harmonic power that operates in high frequency. The output waveform is enhanced and the switching losses are reduced in DBVSC, and the power rating is also increased. The DBVSC is very suitable for large power rating application. The one cycle control theory is adopted to control the proposed DBVSC with analog circuit, which is very simple. The proposed DBVSC and control method are verified by simulation.  相似文献   

13.
The application of non-linear load produces a mass of harmonics. The AC voltage meter and the AC current meter used in power system are usually rectifying instruments, which adopt principle of responding to the average value of voltage and current and get the virtual value by using of the proportion between the average value and it. Because they are designed based on the 50 Hz standard sinuous wave, the principle error will occur when the voltageof power system and the current of loads include harmonic. Based on their working principle, this kind of error is analyzed quantificationally. And the result shows that it can not be neglected. The voltage and current meters with real virtual value are proposed.  相似文献   

14.
For the transmission pressure 27.5 kV of the railroad AC contact network, and the non parallel (on earth) arbitrary plane for the wire wearing surface, the optic fiber was used to isolate the high voltage and to transmit the measurement signal. A remote grating type adaptive automatic machinery transducer was used to detect the AC contact network wire wearing surface with about seven meters from the ground. Based on this method, a system was designed and calibrated, achieving measurement of wire rubbing with high voltage. The actual measurements indicate that the method and the system satisfy the demand of the measurement of contact network wire wearing. The method is significant to the geometric sense measurement of the high voltage charged body.  相似文献   

15.
This paper discuses the method with which the corrosion of the grounding grid can be diagnosed .A grounding grid can handled as a circuit network. With the application of circuit network graph theory and the fault diagnosis theory of analog circuit and optimization, the fault diagnosis equations can be set up. This equations is figured out by Matlab, and the corrosion status of the grounding grid can be deduced from the result.  相似文献   

16.
By using one-cycle control theory, a novel voltage source inverter is proposed. The conventional one-cycle control technique needs that the integrator is reset instantaneously. But it is very difficult to realize with hardware due to the finite time constant of the reset circuitry. Therefore, based on the one-cycle technique, the paper gives a new control scheme to resolve the problem with dual switched integrator, and the performance of the integrators is close to ideal. The paper also uses the dc offset to implement the voltage measurement. Furthermore, the amplitude and frequency of the output voltage are effectively adjustable. The one-cycle control technique not only provides fast dynamic response, but also can admirably suppress the perturbation yielded by dc source and abate the undesired harmonic contents. Simulation studies were performed to prove the proposed scheme. The results show that the one-cycle control based voltage source inverter makes good use of dc source that is 92.8% and THD is only O. 255 9%.  相似文献   

17.
高压静电场杀菌效果研究   总被引:1,自引:0,他引:1  
利用自行研制的直流高压静电场装置针对大肠杆菌进行了杀菌实验研究,结果表明,电压、处理时间是影响电场杀菌作用的主要因素.在极板间距D=3 cm,电压20 kV,处理时间45 min的务件下,大肠杆菌的致死率达到98.7%.  相似文献   

18.
In order to improve the computational efficiency of the insulator electric field inverse problem, the fast multi-pole method has been introduced to the traditional simulation charge method. Tikhonov regularization is used to process the ill-posed characteristic of inverse problem solution caused by the interference. Newton method is used to search the optimum solution, and then the actual field source parameters of insulators and the practical voltage distribution on the surface of the insulators can be obtained. The fast optimization algorithm has been verified in point charge model. And 110 kV insulator string is carried out to demonstrate that the fast optimization algorithm is much faster and more efficient than traditional method.  相似文献   

19.
In this paper, a new microcomputer distance protection scheme with high property-cost ratio has been approached. The paper presents the performance equations based on the symmetrical components of current and voltage, proposes a new (1,a) coordinate plane and derives a Fourier symmetrical component algorithem with high accuracy and less calculation amount on the (1,a) plane. The protection program is debugged on the developing system of single chip computer. The digital imitation tests indicate that the proposed relaying system is satisfactory.  相似文献   

20.
This paper summarizes the requirements of standards for aircraft power supply firstly,and then points out that the input current harmonic and output DC voltage ripple should be considered seriously when designing three-phase power factor correction (PFC)for aircraft under variable line frequency and unbalanced line supply. Based on reviewing the topologies for aircraft three-phase PFC,three typical topologies,i.e. three-phase pulse width modulation (PWM)rectifier,traditional shunt active power filter (APF)and generalized APF,are picked up. A unified single-phase equivalent model is developed for comparing the harmonic suppression performance of the three active PFC schemes. And the switching stress is also calculated for evaluating their efficiency and power density. Three 5 kW PFC are designed by employing each of the three selected schemes. Simulation is carried out to verify the correctness of the theoretical analysis. The theory and simulation results indicate that the generalized APF topology shows the most technical merit for aircraft three-phase PFC. Future research works on generalized APF are also pointed out,which are solving the uncontrollability of its DC output voltage and optimal designing the filter inductors.  相似文献   