首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 505 毫秒
1.
Cortical somatosensory-evoked potentials (SEP) were recorded from thoracic and pelvic limbs in 15 horses (13 Thoroughbreds and 2 Quarter Horses). Ulnar nerve SEP were evoked by electrical stimulation of the lateral palmar branch of the ulnar nerve at the level of the metacarpophalangeal joint. Recordings were taken between electrodes at 2 cm lateral to the vertex (contralateral to the stimulated limb) and the midpoint of the interorbital line. Four peaks were found in all recordings: N1, P1, N2, and P2. Latencies to the peaks were 39.0 +/- 2.7, 45.5 +/- 5.3, 50.4 +/- 5.2, and 62.3 +/- 3.7 ms (mean +/- SD), respectively. Tibial nerve SEP were evoked by stimulation of the lateral plantar nerve branch of the tibial nerve at the level of the metatarsophalangeal joint. Recordings were taken between electrodes at the vertex (contralateral to the stimulated limb) and the midpoint of the interorbital line. Four peaks were also found in all tibial nerve SEP recordings: N1, P1, N2, and P2. Latencies to the peaks were 64.6 +/- 11.8, 84.5 +/- 9.7, 121.2 +/- 11.6, and 134.0 +/- 11.1 ms, respectively. Amplitude variability was high for the ulnar nerve and the tibial nerve SEP. There was no effect of sex seen on peak latency or amplitude, and peak latencies were not affected by body length.  相似文献   

2.
A method was developed to record cortical somatosensory evoked potentials (SEP) from thoracic and pelvic limb stimulation in cows. Recordings were similar in latency and amplitude to those reported for horses. Correction for conduction pathway length did not alter the average latency values because the cows of the study were uniform in size; however, the data provided will enable use of this normative data with smaller or larger individual animals. Although latency variability for the SEP peaks was low, variability of the amplitude measurements was high. This observed variability was similar to that seen in other species. Validity of the recorded responses was indicated by lack of a tibial nerve SEP in 1 cow that had been given a tibial nerve conduction block, using lidocaine, and by repeatability of the response in 2 recordings taken 1 year apart in the same cow.  相似文献   

3.
OBJECTIVE: To determine somatosensory evoked potentials (SEPs) in dogs with degenerative lumbosacral stenosis (DLS) and in healthy dogs. STUDY DESIGN: Clinical and experimental study. ANIMALS: Dogs with DLS (n = 21) and 11 clinically normal dogs, age, and weight matched. METHODS: Under anesthesia, the tibial nerve was stimulated at the caudolateral aspect of the stifle, and lumbar SEP (LSEP) were recorded percutaneously from S1 to T13 at each interspinous space. Cortical SEP (CSEP) were recorded from the scalp. RESULTS: LSEP were identified as the N1-P1 (latency 3-6 ms) and N2-P2 (latency 7-13 ms) wave complexes in the recordings of dogs with DLS and control dogs. Latency of N1-P1 increased and that of N2-P2 decreased as the active recording electrode was moved cranially from S1 to T13. Compared with controls, latencies were significantly delayed in DLS dogs: .8 ms for N1-P1 and 1.7 ms for the N2-P2 complex. CSEP were not different between groups. CONCLUSIONS: Surface needle recording of tibial nerve SEP can be used to monitor somatosensory nerve function of pelvic limbs in dogs. In dogs with DLS, the latency of LSEP, but not of CSEP, is prolonged compared with normal dogs. CLINICAL RELEVANCE: In dogs with lumbosacral pain from DLS, the cauda equina compression is sufficient to affect LSEP at the lumbar level.  相似文献   

4.
OBJECTIVE: To investigate the middle latency auditory evoked potential (MLAEP) in awake dogs and dogs anesthetized with 2 concentrations of sevoflurane. ANIMALS: 10 adult Beagles. PROCEDURE: The MLAEP was recorded while dogs were awake and anesthetized with sevoflurane (end-tidal concentration, 2.7% or 3.5%).Three needle electrodes were inserted SC, and click stimuli were delivered biaurally. Signal acquisition, averaging, and analysis were performed by use of computer software developed in-house. Signals were recorded for 128 milliseconds, and the responses to 1,024 stimuli were averaged. Waveforms from 10 recordings in each dog were averaged, and latencies of peaks were measured. Data acquired for awake dogs and dogs anesthetized with high and low sevoflurane concentrations were compared statistically. RESULTS: Sevoflurane anesthesia attenuated the MLAEP so that only peaks P0, Na, and Pa could be identified. The MLAEP changes were maximal at the lower concentration of sevoflurane evaluated. The latencies of these peaks were significantly shorter in awake dogs, compared with values in anesthetized dogs. No difference in the peak latency was detected between the sevoflurane concentrations. CONCLUSIONS AND CLINICAL RELEVANCE: In terms of CNS responsiveness, the effects of anesthesia with sevoflurane are similar to those of anesthesia with isoflurane. Data suggest that sevoflurane is not the inhalant agent of choice in a research setting where electroencephalographic measurements are to be recorded during anesthesia. The depression of the MLAEP waveform by sevoflurane also suggests that the MLAEP is not a suitable tool with which to monitor anesthetic depth during sevoflurane anesthesia in dogs.  相似文献   

5.
Averaged evoked potentials were recorded from the scalp of 22 dogs after repetitive stimulation of the pudendal nerve. Four experimental procedures were used: (1) percutaneous needle-stimulating electrodes with dogs tranquilized with xylazine; (2) percutaneous needle-stimulating electrodes with dogs tranquilized with acepromazine; (3) percutaneous needle-stimulating electrodes with dogs anesthetized with alpha-chloralose; and (4) Sherrington type stimulating electrodes applied directly to nerves with dogs anesthetized with alpha-chloralose. The average evoked potentials were similar with all treatments. Three peaks (N1, P1, and N2) with consistent latency and amplitude were generally present, followed by additional peaks with variable latencies and amplitudes. The mean latency for N1 after direct stimulation was significantly longer than the mean latency for N1 in the 3 other groups (95% confidence intervals). There were no other significant differences in mean latencies among groups for any of the peaks.  相似文献   

6.
Objective To investigate whether rostral extension of the hind limbs increases the cranio‐caudal dorsal interlaminar distance between the seventh lumbar vertebra and the sacral bone (LS distance) in sternally recumbent anesthetized dogs. Study design Prospective clinical study. Animals Eighteen dogs (eight neutered males, three intact males, six spayed females, one intact female) of various breeds, weighing 4–34 kg and ranging in age from 1 to 13 years. Methods Each dog was grouped by size: small (≤10 kg), medium (15–20 kg) or large (≥25 kg). Each dog was anesthetized and positioned in sternal recumbency. Computed tomography (CT) of the lumbosacral area was performed with the hind limbs resting on the stifle and the feet extended posteriorly, and then with the hind limbs extended rostrally. LS distance, craniocaudal dorsal interlaminar distance between sixth and seventh lumbar vertebra (L6–L7 distance), length of L7 vertebral body and lumbosacral angle (LS angle) were measured on a reconstructed mid‐sagittal CT image from the two hind limb positions. The measurements from the two hind limb positions for the whole dog population and by size were compared using Student’s T tests. Diagnostic interpretation of the CT images was performed. Results The length of L7 was taken as the reference value as it was not affected by hind limb position. LS distance, L6–L7 distance and LS angle were significantly higher when the hind limbs were extended rostrally in all three size groups. The CT images of ten dogs showed clinically undetected osteoarthrosis of the ileo‐ and lumbosacral area. Conclusions and clinical relevance Rostral extension of the hind limbs significantly increases LS and L6–L7 distance and LS angle even in dogs with clinically undetected osteoarthrosis of the ileo‐ and lumbosacral area, and may enhance the ease of lumbosacral epidural injection in sternally recumbent anesthetized dogs.  相似文献   

7.
The compound nerve action potential (CNAP) of the superficial peroneal nerve of dogs was investigated to determine: (1) the influence of the stimulation technique on the configuration of the CNAP, with particular attention to late components; (2) the fiber diameter (FD) distribution; and (3) the relationship between FD distribution and CNAP configuration, by reconstruction of CNAP made on the basis of FD distributions. The CNAP were evoked in 9 dogs under halothane anesthesia by 2 stimulation methods: percutaneous needle electrode stimulation and direct stimulation of the exposed superficial peroneal nerve. Recordings were made with percutaneous needle electrodes. Full nerve cross sections of 7 superficial peroneal nerves were prepared for FD morphometric analysis. Reconstruction of CNAP were made on the basis of the FD distributions. Late components of the CNAP could be evoked with either stimulation method, but only with a stimulus intensity of 3 to 5 times maximal for the main (early) component of the CNAP. The FD histograms of 7 analyzed nerves had bimodal distribution. In 5 nerves, peaks were at 4.2 to 4.5 microns and 9.0 to 10.0 microns, with 60% of the fibers in the small-diameter group. In 2 nerves with lower maximal conduction velocities, peaks were shifted toward smaller values. The CNAP reconstructions made by use of FD data closely resembled actual recordings when a fifth-order polynomial function was applied to the relationship between nerve conduction velocity and FD. Reconstructions made by use of 1 or 2 linear functions did not accurately resemble actual recordings.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

8.
OBJECTIVE: To investigate the value of nasopharyngeal and tracheal recordings of somatosensory evoked potentials (SSEP) in anesthetized dogs. ANIMALS: 10 healthy mixed-breed dogs (5 males and 5 females). PROCEDURE: Square-ware electrical stimuli (50 microseconds duration, 4Hz) were delivered through bipolar surface electrodes to the median nerve of the right forelimb with 7 to 12 mA constant current. The SSEP were recorded with soft electrodes placed on the epipharynx and dorsal wall of the trachea, respectively. Traditional scalp and neck recordings of SSEP were also performed, using SC-inserted needle electrodes. The potentials recorded dorsally and ventrally from the neuraxis were compared to assess the application of these signals for intraoperative neurophysiologic monitoring. RESULTS: Electrical stimulation of the median nerve resulted in multiphasic potentials recorded from all 4 recording sites. Latency and phase shifts were observed between the far-field potentials placed ventrally and dorsally from the neuraxis. CONCLUSIONS AND CLINICAL RELEVANCE: Potentials recorded with nasopharyngeal and tracheal electrodes are regarded suitable for intraoperative neurophysiologic monitoring in anesthized dogs.  相似文献   

9.
We conducted somatosensory evoked potential (SEP) monitoring on 3 dogs with cervical spinal cord dysfunction caused by various diseases throughout operative procedures to examine whether the intraoperative SEP monitoring was effective for prediction of spinal cord conductive function. The SEP was recorded on the scalp via stimulation of the ulnar nerve. Stable SEP was recorded in all animals examined. Its amplitude was decreased by surgical manipulations of the regio vertebralis, but the amplitude gradually recovered once the manipulations were halted. The latency showed small variation throughout the operations. This evidence suggests that intraoperative SEP monitoring may provide continuous and instantaneous information regarding the functional integrity of the central nervous system.  相似文献   

10.
Microneurovascular Free Digital Pad Transfer in the Dog   总被引:1,自引:0,他引:1  
By cadaver dissections, the fifth digit of the canine hind limb was determined to have a consistent neurovascular anatomy, and therefore be a suitable donor for an axial pattern digital pad flap. The defined digital pad flap was transferred to the region of an excised metacarpal pad by microneurovascular anastomoses in five operations on four dogs. One flap failure was considered to result from failure of the venous anastomosis. In all four successful transfers, cutaneous sensation was reestablished on average in 78 days. There was histologic evidence of nerve regeneration across the anastomosis in one dog at week 24. The transferred pads of three dogs monitored for 15 months underwent hypertrophic changes. There were no complications in two active dogs. In one dog, superficial ulceration of a region of the flap adjacent to the pad required surgical revision. This dog continued to show mild lameness after daily runs of 3 to 4 km.  相似文献   

11.
OBJECTIVE: To compare 3 types of noxious stimuli applied to various anatomic areas of anesthetized dogs and rabbits for determination of the minimum alveolar concentration (MAC). ANIMALS: 10 dogs and 10 rabbits. PROCEDURE: Dogs were anesthetized with isoflurane and halothane in a randomized order. Rabbits were anesthetized with isoflurane. The MAC was determined by skin incision on the lateral aspect of the chest; clamping of the tail, paw of the forelimb, and paw of the hind limb; and application of electrical current to the oral mucosa (dogs only), forelimb, and hind limb. The MAC was the end-tidal concentration midway between the value permitting and preventing purposeful movement in response to noxious stimuli. RESULTS: In dogs, mean +/- SEM MAC for isoflurane was 1.27 +/- 0.05% for clamping stimuli, 1.36 +/- 0.04% for oral electrical stimulation, 1.35 +/- 0.04% for electrical stimulation to the limbs, and 1.01 +/- 0.07% for surgical incision. The MAC for halothane was 0.97 +/- 0.03% for tail clamping, 0.96 +/- 0.03% for clamping of the limbs, 1.04 +/- 0.03% for electrical stimulation, and 0.75 +/- 0.06% for surgical incision. In rabbits, MAC for isoflurane was 2.08 +/- 0.02% for clamping stimuli, 2.04 +/- 0.02% for electrical stimulation, and 0.90 +/- 0.02% for surgical incision. The MAC for surgical incision was significantly lower than values for the other methods in both species. CONCLUSIONS AND CLINICAL RELEVANCE: Use of electrical current and clamping techniques resulted in similar MAC values. Surgical incision underestimated MAC values in dogs and rabbits.  相似文献   

12.
Spinal evoked potentials (SpEP) were recorded on an electromyograph from electrodes placed percutaneously in the ligamentum flava at the lumbosacral junction and between the 10th and 11th thoracic vertebrae following tibial nerve stimulation in 31 anesthetized dogs with acute compressive spinal cord injuries. The neurologic status of each dog was determined by clinical examination before SpEP recordings, and the neurologic status was monitored for 2 months in dogs that had surgical or conservative treatment. Two months after spinal injury, the response to treatment (outcome) of each dog was evaluated and graded as favorable (ambulatory and urinary continent) or unfavorable (nonambulatory, urinary incontinent, or euthanatized with confirmation of myelomalacia). Onset latencies, conduction velocities, amplitudes and durations of the wave forms, and the ratio of conduction velocity to combined durations of the first positive (P1) and first negative (N1) waves (CV/DPN index) were determined and were compared with reference data from clinically normal (control) dogs. Single SpEP recordings were of value in determining the prognosis for recovery. Significant differences were not found in the L7-S1 recordings between the reference (control) and spinal injury groups. Analysis of data from the T10-11 recordings indicated significant differences between the reference and spinal injury groups and between the favorable and unfavorable outcome groups within the spinal injury group. A CV/DPN index was less than 30 in dogs with unfavorable outcomes and greater than 30 in dogs with favorable outcomes. Stepwise discriminant analysis of data from the spinal injury group predicted outcome correctly in all dogs.  相似文献   

13.
OBJECTIVE: To examine the agreement between direct arterial blood pressure measurements obtained from 2 arteries and indirect blood pressure measurements obtained with an oscillometric blood pressure monitor (OBPM) during normotension and phenylephrine-induced hypertension in dogs. ANIMALS: 16 male Beagles. PROCEDURES: In anesthetized dogs, arterial catheters were placed in the lingual and dorsal pedal arteries for measurement of arterial blood pressure. A blood pressure cuff was placed on either the dog's fore- or hind limb and connected to an OBPM. Systolic, diastolic, and mean arterial blood pressures (SAP, DAP, and MAP, respectively) were recorded from both arteries and the OBPM every 5 minutes for 30 minutes (baseline), during a 30-minute period in which dogs received a phenylephrine infusion IV to induce hypertension, and for 30 minutes after discontinuation of the infusion. Mean differences in blood pressure values and confidence intervals were calculated to compare the indirect and direct measurement techniques. RESULTS: In dogs, oscillometry underestimated SAP during normotension, and the difference between oscillometric and direct measurements increased during hypertension. Oscillometry underestimated DAP, but the difference between oscillometric and direct measurements decreased during hypertension. There was close agreement among techniques for MAP determinations. Biases between direct measurements and OPBM blood pressure values measured from dogs' forelimbs or hind limbs were not significantly different. CONCLUSIONS AND CLINICAL RELEVANCE: In normotensive dogs, oscillometric measurements of MAP and SAP agreed more closely with direct arterial pressure measurements than oscillometric estimates of DAP. Oscillometric measurement of MAP was accurate during both normotension and hypertension in dogs.  相似文献   

14.
Somatosensory-evoked potentials (SEP) and spinal cord-evoked potentials (SCEP) were recorded in clinically normal adult cats in response to electrical stimulation of pudendal and tibial nerves to provide normative data that can be used in a clinical evaluation of pudendal nerve function in cats after sacral or sacrococcygeal luxations or fractures. Responses to tibial nerve stimulation were included in the study as an internal control because it is usually not involved in these types of injuries and because its SEP and SCEP are easily recorded. Evoked potentials were characterized by the latencies (ms) of positive (P or p) and negative (N or n) peaks. The SEP resulting from percutaneous pudendal nerve stimulation consisted of a prominent P-N-P potential in the 30- to 80-ms range. The pudendal SCEP was not successfully recorded because of large muscle artifacts evoked from the sacral area. The tibial SEP was similar to the pudendal SEP, except that the prominent P-N-P series in the 35- to 81-ms range was preceded by a smaller p-n-p-n sequence in the 7- to 23-ms range. The tibial SCEP consisted of a P-N-P series in the 2- to 4-ms range.  相似文献   

15.
Following unsuccessful attempts to record visual-evoked potentials (VEPs) in dogs with scalp electrodes, adoption of a new stimulation technique seems to be beneficial. Previously, flashes of white light administered after dark adaptation induced relatively high amplitude electroretinograms (ERGs) covering any VEP activity over the surface of the skull. ERG amplitude, however, can be significantly reduced using flashes of red light after light adaptation (mostly cone stimulation). Simultaneous ERG and VEP recording allows identification of VEPs composed of three significantly different negative peaks (N1, N2, and N3) measured in dogs anesthetized with chloralose and halothane. No more than two of the three peaks were seen in one recording. Only the N1 and N3 waves were consistently recorded in dogs anesthetized with thiopental and thiopental combined with halothane. In 50% of all recordings, N1 was seen alone. The other VEPs consisted of N1 and N2, or N1 and N3 occurring concurrently. The simultaneous occurrence of N2 and N3 waves, however, was never seen. Among all recordings, N1 was most frequently recorded (85% of measurements), followed by N3 and N2 (38% and 31% of measurements, respectively). Peaks of less than 90 ms are highly reproducible. Anesthesia is necessary to eliminate frequent artifacts obtained in conscious and sedated dogs. Thiopental and/or halothane had no effect on measured latencies compared with chloralose.  相似文献   

16.
OBJECTIVE: To compare nociceptive withdrawal reflexes (NWRs) evoked from the distal aspect of the left forelimb and hind limb in conscious standing horses and to investigate NWR recruitment for graded electrical stimulation intensities. ANIMALS: 20 adult horses. PROCEDURE: Surface electromyographic (EMG) activity evoked by transcutaneous electrical stimulation of the digital palmar (or plantar) nerve was recorded from the common digital extensor and cranial tibial muscles. Stimuli consisted of 25-millisecond train-of-5 constant current pulses. Current intensity was gradually increased until NWR threshold intensity was reached. The EMG signal was analyzed for quantification of the NWR. Behavioral responses accompanying the reflex were scored (scale, 0 to 5). The NWR recruitment curves were determined at 0.9, 1.1, 1.2, and 1.3 times the NWR threshold intensity. RESULTS: The NWR threshold was significantly higher for the hind limb (median value, 6.6 mA; range, 3 to 10 mA) than the forelimb (median, 3 mA; range, 1.7 to 5.5 mA). The NWR of the hind limb had a significantly longer latency (median, 122.8 milliseconds; range, 106 to 172 milliseconds), compared with the forelimb (median, 98 milliseconds; range, 86 to 137 milliseconds), and it was associated with significantly stronger behavioral reactions. Gradual increase of NWR amplitude was evident at increasing stimulation intensities and supported by the behavioral observations. CONCLUSIONS AND CLINICAL RELEVANCE: We documented NWRs evoked from the forelimb and hind limb and their recruitment with stimuli of increasing intensity in horses. These results provide a basis for use of NWRs in studies on nociceptive modulation in horses.  相似文献   

17.
Pharmacodynamic properties of succinylcholine in greyhounds   总被引:1,自引:0,他引:1  
Succinylcholine is a depolarizing neuromuscular blocking drug, which is rapidly hydrolyzed by the enzyme pseudocholinesterase. In Greyhounds, the metabolism of certain drugs is atypical relative to other breeds, and it has been suggested that Greyhounds may be an atypical population, with lower pseudocholinesterase activity, slower hydrolysis of the drug succinylcholine, and a prolonged duration of action of the drug, compared with a mixed-breed control population. Six healthy adult Greyhounds and 6 healthy adult mixed-breed dogs were studied. Blood was drawn from each dog and analyzed for serum cholinesterase activity, and a biochemical profile was done to verify normal liver function. The dogs were anesthetized with methohexital (10 mg/kg) and isoflurane (1.25 minimal alveolar concentration) in 100% oxygen. Ventilation was controlled, fluids were administered IV (lactated Ringer solution, 10 ml/kg/h), and blood gases, blood pressure, and heart rate were monitored. The right hind limb was immobilized and a force transducer was used to monitor twitch strength of the interosseous muscle with supramaximal stimulation of the tibial nerve. Succinylcholine was administered to each dog 3 times at a dosage of 0.3 mg/kg. After drug administration, the time to 50% recovery of twitch strength (single twitch, 1/s), and 50% recovery of train-of-4 was determined. Subsequent doses were administered after complete recovery. The time to 50% recovery after succinylcholine administration in Greyhounds (38 minutes, dose 1, single twitch) was not significantly different than the time to 50% recovery in mixed-breed dogs (29 minutes, dose 1, single twitch), using either monitoring technique. Pseudocholinesterase activity was also not significantly different between the Greyhounds (1,685 mU/ml) and the mixed-breed dogs (1,588 mU/ml).(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

18.
Analysis of human nerve biomechanics has contributed to the validation of clinical tests to diagnose back pain of neural origin. Equivalent clinical tests for dogs would be valuable to differentially diagnose lumbosacral pain. To develop such a test, the increase in strain in the sciatic nerve of dogs and the longitudinal excursion of the nerve in relation to its surrounding structures during hind limb movements were evaluated. A miniature strain gauge was inserted into the sciatic nerve in seven canine cadavers and excursion was measured using a digital calliper. A cumulative increase in strain of 7.2% (+/-2.8%) was observed for the combined movements of hip flexion, stifle extension, hock flexion and digit extension (P<0.0001). Although all components contributed significantly to the increase (P=0.03), the sciatic nerve demonstrated a curvilinear response to increased loading. A 10.0+/-1.0mm excursion was recorded with stifle extension (P=0.002). It was concluded that, the sciatic nerve in dogs accommodates to joint movements by stretching and gliding. This biomechanical analysis has contributed to the development of a clinical test equivalent to the human straight leg raise to evaluate increased mechanosensitivity of the lumbosacral plexus.  相似文献   

19.
Background: Generalized myokymia and neuromyotonia (M/NM) in Jack Russell Terriers (JRTs) is related to peripheral nerve hyperexcitability syndrome in humans, a symptom complex resulting from diverse etiologies. Objective: Clinical and electrodiagnostic evaluation is used to narrow the list of possible etiological diagnoses in JRTs with M/NM. Animals: Nine healthy JRTs and 8 affected JRTs. Methods: A prospective study was conducted comparing clinical and electrophysiological characteristics in 8 JRTs affected by M/NM with 9 healthy JRT controls. Results: All affected dogs except 1 had clinical signs typical of hereditary ataxia (HA). In 6 dogs, neuromyotonic discharges were recorded during electromyogram. Motor nerve conduction studies showed an axonal neuropathy in only 1 affected dog. Compared with controls, brainstem auditory‐evoked potentials (BAEP) showed prolonged latencies (P < .05) accompanied by the disappearance of wave components in 3 dogs. Onset latencies of tibial sensory‐evoked potentials (SEP) recorded at the lumbar intervertebral level were delayed in the affected group (P < .001). The BAEP and SEP results of the only neuromyotonic dog without ataxia were normal. Conclusions and Clinical Importance: The BAEP and spinal SEP abnormalities observed in JRTs with M/NM were associated with the presence of HA. Therefore, these electrophysiological findings presumably arise from the neurodegenerative changes characterizing HA and do not directly elucidate the pathogenesis of M/NM. An underlying neuronal ion channel dysfunction is thought to be the cause of M/NM in JRTs.  相似文献   

20.
The objectives of this study were to determine whether thermal quantitative sensory testing (QST) can be performed in client-owned dogs, is repeatable and whether QST differs between normal dogs and dogs with hind limb osteoarthritis (OA). This clinical, prospective, observational study used clinically normal dogs (n = 23) and dogs with OA-associated hind limb pain (n = 9). Thermal QST was performed in standing dogs using a high-powered light source delivered by a previously validated system. Dogs were tested on two occasions, 2 weeks apart. Five tests were performed on each hind limb at each time point. Repeated measures analysis of variance was used to evaluate the effects of leg, time point and OA/normal status on thermal threshold latencies (TTL). Additionally, paired t tests were used to compare the TTL of left and right limbs within groups and between time points.Thermal thresholds were successfully measured in 32 client-owned dogs without prior training. TTL were significantly different between normal and OA dogs (P = 0.012). There was no difference between limbs (P = 0.744) or time periods (P = 0.572), when analyzed by repeated measures analysis of variance, and no interactions between group and limb, visit and limb, or visit and group. In conclusion, thermal thresholds can be measured in client owned dogs with no prior training and are repeatable from week to week. Further data are required to determine if OA results in thermal hypoalgesia as measured at the distal hind limb and whether this is an indication of central sensitization.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号