首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
OBJECTIVE : To determine the feasibility of indirect suture passage around the right portal vein for attenuation of right-sided intrahepatic portosystemic shunts (IHPSS). STUDY DESIGN : Anatomic study of cadavers and prospective evaluation of clinical cases. ANIMALS : Nine canine cadavers (median weight, 20.5 kg) and 6 client-owned dogs suspected of having right-sided IHPSS. METHODS : Silicone casts of the caudal vena cava and pre- and intrahepatic portal veins were made in fresh canine cadavers. A suture was passed dorsal to the portal vein above and below its bifurcation and pulled laterally so that it surrounded the right portal vein. The number and size of portal and caudal vena cava branches that interfered with the suture passage were recorded. Intra- and postoperative complications were evaluated in 3 dogs with right-sided IHPSS and 3 dogs suspected of having right-sided IHPSS that had right portal vein dissection and occlusion using this technique. RESULTS : Suture passage and placement around the right portal vein were easily accomplished in all 9 specimens. A 1 mm branch from the dorsal surface of the right portal vein was included in the encircling ligature in 4 specimens. The dissection technique was used successfully in 3 dogs with right-sided IHPSS and 2 other clinical cases. The portal branch to the papillary process of the caudate lobe interfered with suture placement in 1 dog with a central IHPSS. CONCLUSIONS : Indirect suture passage for ligation of the right portal vein can be successfully performed in normal dogs and dogs with congenital portosystemic shunts. CLINICAL RELEVANCE : Hemorrhage, vascular trauma, and surgery time may be reduced using this technique for attenuation of right-sided IHPSS.  相似文献   

2.
The left lateral hepatic lobe was removed in six dogs with a stapling instrument and in six dogs by blunt dissection and ligation. Both techniques were safe and effective. Lobectomy by dissection and ligation was slower and less complete than by stapling. Major intraoperative or postoperative hemorrhage did not occur with either method. Serum chemistry values were elevated after surgery in all dogs but did not differ significantly between treatment groups. Microscopic hemorrhage, necrosis, and inflammation of the lobectomy site were more pronounced after dissection and ligation than stapling.  相似文献   

3.
OBJECTIVE: To compare the incidence of residual patent ductus arteriosus (PDA) flow after ligation using 2 different dissection techniques: a standard dissection and a method described by Jackson and Henderson. STUDY DESIGN: A randomized, prospective study. ANIMALS: Thirty-five dogs admitted for surgical correction of a left to right shunting PDA. METHODS: Dogs were randomly assigned: 19 to a standard dissection technique (group S) and 16 to the Jackson and Henderson dissection group (group JH). RESULTS: Gender ratio, age at surgery, and diameter of the ductus were not statistically different between groups. Breed distribution was also similar. Because 1 dog had fatal intraoperative hemorrhage, only 34 dogs were available for residual flow comparisons. Twenty-one percent of group S dogs had residual flow compared with 53% in group JH. Whereas no intraoperative complications occurred in group S, 3 were encountered in group JH. CONCLUSIONS: The incidence of residual flow was higher when the Jackson and Henderson dissection was used for PDA ligation compared with a standard method of dissection. This was probably because of entrapment of loose connective tissue within the medial aspect of the ligature, impeding complete closure of the ductus. CLINICAL RELEVANCE: Ideal PDA closure should result in no residual ductal flow to prevent possible adverse long-term sequelae, such as recanalization and infective endocarditis.  相似文献   

4.
A mucosal apposition technique for cholecystoduodenostomy was compared to the cutting suture technique. The mucosal apposition technique was easier to perform, less traumatic, and produced a significantly larger anastomotic opening than the cutting suture technique. Eleven of 12 dogs returned to normal activity within 5 days after the mucosal apposition technique. Six of 12 dogs required 10 to 21 days after the cutting suture technique before regaining normal activity. Healing was similar for both techniques. Aerobic and anaerobic bacteria were cultured from the gallbladders of both groups postoperatively.
Cholecystograms demonstrated rapid drainage of the biliary system following mucosal apposition. Drainage of the biliary system following the cutting suture technique was slower; gallbladders tended to be irregularly shaped and distended.
Gallbladders rapidly filled with contrast material during upper gastrointestinal barium studies following cholecystoduodenostomy by mucosal apposition. Gallbladders filled more slowly and less completely following the cutting suture technique: drainage of refluxed contrast material was delayed in some dogs.
Serum enzyme elevations (SGPT, SAP) and subclinical periportal inflammation and fibrosis were found following both techniques. Peripheral circulating eosinophil counts were significantly higher in dogs following the cutting suture technique.  相似文献   

5.
Objective: To (1) describe a technique for splenic vessel hemostasis and (2) report complications and outcome after use of bipolar sealant device during splenectomy in dogs. Study Design: Case series. Animals: Dogs (n=27) with naturally occurring splenic disease. Methods: Between January 2006 and March 2008, splenectomy was performed using a vessel sealant device in 27 dogs with naturally occurring splenic disease. Number of sutures needed for splenectomy and complications were recorded. Splenic artery diameter was measured using a caliper. Intraoperative hemostasis, device ease of use, postoperative hemorrhage, and short‐term survival were evaluated. Results: Splenectomy was performed successfully in 27 dogs with the vessel sealant device; none of the dogs required vessel ligation with suture. The splenic artery was dissected and adequately sealed in each dog. One dog was readmitted 4 days after surgery with hemoabdomen. Abdominal exploration revealed splenic pedicle hemorrhage and pancreatitis, the vessel sealant device was used to coagulate splenic pedicle bleeding. The dog was alive at suture removal. Conclusion: In dogs, a vessel sealant device may be used to achieve efficient and safe hemostasis of the splenic vascular pedicle without sutures.  相似文献   

6.
OBJECTIVE: To determine outcome associated with intramural ureteral ectopia treated with 1 of 2 surgical techniques (neoureterostomy with ligation of the distal ureteral segment vs neoureterostomy with resection of the distal ureteral segment) and compare results of these 2 techniques in dogs. DESIGN: Multicenter retrospective case series. ANIMALS: 36 dogs (15 treated with the ligation technique and 21 treated with the resection technique). PROCEDURES: Information was obtained from medical records. Long-term follow-up information was obtained by owner questionnaire. RESULTS: 15 of 21 (71%) dogs in the resection group and 7 of 14 (50%) dogs in the ligation group still had urinary incontinence after surgery. Three of 20 (15%) dogs in the resection group and 4 of 14 (29%) dogs in the ligation group reportedly had multiple episodes of urinary tract infection following surgery. The outcome of surgery was judged to be excellent by the owners of 10 of 18 (56%) dogs in the resection group and 9 of 14 (64%) dogs in the ligation group. No significant differences were found between surgery treatment groups. CONCLUSIONS AND CLINICAL RELEVANCE: Results of the present study suggest that although most owners of dogs that undergo surgery for treatment of intramural ureteral ectopia consider the outcome of surgery to be excellent, substantial proportions of dogs will continue to have urinary incontinence and recurrent urinary tract infections after surgery. Findings do not provide any support to the hypothesis that the resection technique is superior to the ligation technique for management of dogs with intramural ureteral ectopia.  相似文献   

7.
Two suture techniques for tracheal anastomosis after large-segment tracheal resection were compared. Eight cartilages were resected from the trachea of each of 12 dogs; anastomoses with 4-0 polydioxanone suture were created using a simple continuous suture technique in six dogs and a simple interrupted suture technique in six dogs. Surgical time was shorter but apposition of tracheal segments at the time of surgery was less precise with the simple continuous suture technique. The dogs were evaluated for 150 days after surgery. Clinical abnormalities after tracheal resection and anastomosis were not observed. Percent dorsoventral luminal stenosis was calculated by measuring the tracheal lumen diameter on lateral cervical radiographs. Percent luminal stenosis was calculated planimetrically using a computerized digitizing tablet. Anastomotic stenosis was mild in all dogs; however, the mean percent luminal stenosis determined planimetrically was significantly greater for dogs that had the simple continuous suture technique. Planimetric measurements of cross-sectional area made before and after formalin fixation were not significantly different. Radiographic determination of percent dorsoventral luminal stenosis was a poor predictor of diminution of cross-sectional area determined planimetrically.  相似文献   

8.
Surgical treatment of 201 dogs with patent ductus arteriosus at the College of Veterinary Medicine, The Ohio State University was evaluated retrospectively to determine risk factors for development of surgical complications. During surgery, 15 dogs (7%) died because of hemorrhage associated with ductus dissection (n = 8), pulmonary edema (n = 4), ventricular fibrillation (n = 1), hemorrhage not associated with ductus dissection (n = 1), and cardiac arrest immediately after ductus ligation (n = 1). An additional 8 dogs (4%) died less than 1 month after surgery (total mortality before, during, and immediately after surgery, 11%). Nineteen dogs (9.5%) developed hemorrhage during surgery. Sixteen dogs developed complications other than hemorrhage (pulmonary edema [n = 4], cardiac arrest [n = 4], iatrogenic lung trauma [n = 3], ventricular fibrillation [n = 2], septicemia [n = 2], and recanalized ductus [n = 2]). Correlation was not found between age, sex, body weight, surgical technique (Jackson method vs standard method of dissection), or surgeon level of training and development of hemorrhage during surgery, other complications, or survival less than 5 days. Positive correlation (P less than 0.05) was found between hemorrhage and death within 5 days after surgery. Positive correlation (P less than 0.05) was also found between other complications and death within 5 days after surgery. Nineteen dogs survived surgery, but later died of unrelated causes (mean life span, 57 months); 63 of the dogs were still alive and doing well as of January 1990 (mean life span, 47 months after surgery). Contrary to previous reports, age, body weight, and surgical technique did not affect results.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

9.
A simple manoeuvre is described which prevents incorporation of soft tissue by the forceps when passing suture around the blind (medial) side of the aorta or ductus arteriosus during ligation of patent ductus arteriosus in dogs.  相似文献   

10.
OBJECTIVE: To compare clinical outcome, healing, and effect of tracheostomy in conventional incisional and carbon dioxide (CO2) laser techniques for resection of soft palates in brachycephalic dogs. DESIGN: Prospective randomized trial. ANIMALS: 20 adult brachycephalic dogs. METHODS: Dogs were randomly allocated into 4 groups, and 1 of the following was performed: palate resection by use of a CO2 laser; incisional palate resection and closure with suture; and palate resection by use of a C02 laser or incision with tracheostomy. A clinical score for respiratory function was assigned to each dog at 0, 2, 8, 16, and 24 hours. Biopsy specimens of incision sites obtained at days 0, 3, 7, and 14 were examined. Data were analyzed to determine the effects of technique on clinical and histologic outcome. RESULTS: Mean surgical time for laser (309 seconds) was significantly shorter than for sharp dissection (744 seconds). Surgical technique significantly affected clinical scores at 3 of the 5 postoperative time points, but differences were not clinically apparent. Tracheostomy significantly affected clinical scores at 3 of 5 postoperative time points. After tracheostomy tube removal, clinical scores were similar to those of dogs without tracheostomies. Inflammation, necrosis, and ulceration were evident in all groups at day 3; these lesions had almost resolved by day 14. Most complications were associated with tracheostomy. CONCLUSIONS AND CLINICAL RELEVANCE: Clinical outcomes appear to be similar with the laser and incisional techniques. Regarding surgical time and ease, laser resection of the soft palate appears advantageous. Tracheostomy is not warranted in dogs that have uncomplicated surgeries and recoveries.  相似文献   

11.
OBJECTIVE: To describe a minimally invasive technique for castration of bull calves by in situ ligation of the spermatic cord. STUDY DESIGN: Experimental study. ANIMALS: Male calves (n=6) aged, 48-56 days. METHODS: Calves were blocked by weight and then separated into 3 groups: (1) bilateral spermatic cord ligation; (2) unilateral-1 spermatic cord ligated; and (3) control-neither spermatic cord ligated. After local anesthesia, in situ spermatic cord ligation was achieved by restraining the cord laterally within the scrotal sac and passing suture through a hypodermic needle inserted caudal to cranial at the neck of the scrotum and adjacent the medial margin of the restrained spermatic cord. The needle was removed leaving the suture in place and the spermatic cord repositioned medially, then the needle was reinserted through the original holes and the suture passed back through the needle, which was withdrawn. The suture ends were tied ligating the spermatic cord, leaving the knot subcutaneously. Calves were monitored and testes removed after 30 days for gross and histologic examination. RESULTS: Castration was accomplished without postoperative complications. Spermatic cord ligation resulted in testis atrophy, and histologically, complete ischemic necrosis. CONCLUSIONS: This novel minimally invasive technique is a simple, alternative method for castration of bull calves. CLINICAL RELEVANCE: This method of castration is simply performed, without obvious skin wounds, and no postoperative care needed. The technique should be readily adaptable to other species.  相似文献   

12.
Objective— To describe a minimally invasive technique for preparation of teaser rams by needle-assisted ligation through the tail of the epididymis.
Study Design— Experimental study.
Animals— Mature rams (n=6), estrus-induced ewes (2).
Methods— After local anesthesia, epididymis ligation was achieved by restraining the testis distally within the scrotal sac and passing suture through a hypodermic needle inserted between tail of epididymis and distal pole of testis, caudomedial to craniolateral through the scrotum. The needle was removed leaving the suture in place and the testis pushed up dorsally, then the needle was reinserted through the original holes and the suture passed back through the needle, which was withdrawn. This resulted in the suture forming a complete loop around the epididymis. The suture ends were tied ligating the epididymis. Semen was evaluated pre- and postligation. Testes were removed after 30 days for gross and histologic examination.
Results— Epididymis ligation was accomplished without postoperative complications. Three weeks after the epididymis ligation, no motile and live spermatozoa were found in ejaculates. From 5 to 28 days after epididymis ligation, attraction to ewes and libido was unchanged and similar to 14 days before ligation.
Conclusions— This novel minimally invasive technique is a simple, alternative method for preparation of teaser rams.
Clinical Relevance— This method is simply performed, without skin wounds, and minimal postoperative care is needed. The technique should be readily adaptable to other species.  相似文献   

13.
OBJECTIVE: To report the use of sodium nitroprusside to induce deliberate hypotension to reduce hemorrhage and facilitate surgical ligation of complicated patent ductus arteriosus (PDA) in dogs. STUDY DESIGN: Retrospective study. ANIMALS: Six dogs. METHODS: Hemorrhage occurred during surgical ligation of PDA in 5 dogs. Surgical dissection and isolation of the PDA were very difficult in a sixth dog that was considered to be at increased risk for ductus rupture. Sodium nitroprusside (5 to 25 microg/kg/min intravenously) was administered to these 6 dogs to induce hypotension to reduce blood loss and facilitate surgical ligation of the PDA. RESULTS: Sodium nitroprusside infusion reduced blood pressure (mean arterial pressure, 45 to 60 mm Hg) within 5 to 10 minutes and hemorrhage from the PDA, facilitating its surgical ligation. Recovery from surgery and anesthesia was uneventful in all 6 dogs. CONCLUSIONS: Sodium nitroprusside infusion can be used to induce deliberate hypotension in dogs to facilitate surgical ligation of PDA. CLINICAL RELEVANCE: Sodium nitroprusside infusion produces hypotension within 5 to 10 minutes and is easy to control, rapidly abates, and should help to facilitate surgical ligation of PDA.  相似文献   

14.
OBJECTIVES: To evaluate technique, complication rates, postoperative pain scores, and clinical outcomes in dogs after laparoscopic ovariohysterectomy (LOVH) or traditional ovariohysterectomy (OVH). STUDY DESIGN: Prospective clinical trial. ANIMALS OR SAMPLE POPULATION: Thirty-four intact female dogs, weighing 2.4-31 kg. METHODS: LOVH (16 dogs) was performed by ligation of the uterus and ovaries with surgical wire, and then removal by an assisted laparoscopic technique. OVH was performed in 18 dogs. Subjective and objective pain scores were assigned at 0, 2, 8, and 24 hours. Surgical time, complications, and pain and incision scores were evaluated. Dogs were followed for up to 6 months. RESULTS: The mean surgical time for LOVH (120 minutes; range, 47-175 minutes) was significantly longer than for OVH (69 minutes; range, 25-140 minutes). Significantly lower pain scores (subjective, in 2 of 10 categories; objective, in 8 of 10 categories) were identified with LOVH at 1 or more time periods. Surgical complications with LOVH were postoperative fever and anorexia (1 dog), minor splenic (3) or pedicle hemorrhage (4), intermittent vaginal hemorrhagic discharge (1), and suture reaction (3). Surgical complications with OVH were hemorrhage from an ovarian pedicle requiring reoperation (1 dog), dehiscence of the abdominal wall (1), and seroma (1). Anesthetic complications included hypotension in 8 OVH dogs and 1 LOVH dog, and hypothermia in 4 OVH and 9 LOVH dogs. The mean incision scores were lower for LOVH at all time periods. CONCLUSION: LOVH was performed successfully in young nonparous dogs >10 kg. Surgical time and complication rates were greater; however, LOVH postoperative pain scores were < or =OVH scores. CLINICAL RELEVANCE: LOVH is a potentially safe surgical alternative to traditional OVH in dogs. Equipment cost and necessity for more than 1 surgeon may limit its usefulness in small animal practice.  相似文献   

15.

Objectives

To describe a technique using bipolar electrosurgical forceps for haemostasis during open ovariectomy of bitches and queens and for castration of dogs and to determine whether these forceps reduced surgical time compared to ligation with suture.

Materials and Methods

Bipolar electrosurgical forceps were used for haemostasis in 3744 open surgeries including ovariectomies in bitches (n=1406) and queens (n=859) and castrations in dogs (n=1335). The forceps were also used to assist with ovariohysterectomy in bitches (n=89) and queens (n=55). The effect of bipolar electrocoagulation and other likely factors influencing surgical time was examined using linear regression analysis of 367 surgeries.

Results

The use of the forceps reduced surgical time by 9·7 ±2·8 minutes in bitches and by 3·0 ±1·5 minutes in queens. The complications encountered initially were small superficial skin burns requiring topical treatment and one case of haemorrhage associated with surgical technique.

Clinical Significance

Bipolar electrosurgical forceps reduce surgical time in ovariectomies, and complications are rare. This technique has promise for widespread application in veterinary practice to assist with haemostasis in ovariectomy of bitches and queens.  相似文献   

16.
This study compares the healing of oronasal defects created by partial maxillectomy when closed using two different suture materials and two different suture patterns. In experiment 1, 24 dogs were divided into four equal groups. Partial maxillectomy was performed on each dog and was closed using either a two-layer simple interrupted suture pattern (12 dogs) or a modified Mayo mattress pattern (12 dogs) with either polyglactin 910 (12 dogs) or polypropylene (12 dogs) sutures. On the seventh postoperative day, the dogs were euthanized, suture line bursting pressures were measured, and wound healing was evaluated grossly and histopathologically. Suture line dehiscence occurred in one dog from each of the four groups. These were the only dogs in which electrocoagulation had been used. The healing of suture lines closed with the two-layer simple interrupted pattern was superior to that of those closed with the modified Mayo mattress pattern based on the degree of gross oral ulceration, suppurative inflammation, fibrosis and oral epithelial covering at the suture line, and the number of necrotic sites in the adjacent tissue. The healing of suture lines closed with polypropylene was superior to that of those closed with polyglactin 910 based on suture line bursting pressures and the degree of suppurative inflammation and tissue necrosis at the suture sites. In Experiment 2, partial maxillectomies were performed on four dogs, and closure was achieved using a two-layer simple interrupted suture pattern with either polyglactin 910 (two dogs) or polypropylene (two dogs). On the 30th postoperative day, the dogs were euthanized, and wound healing was evaluated grossly and histopathologically. All suture lines were well healed. All polyglactin 910 oral sutures were absent, while all polypropylene oral sutures were still present.  相似文献   

17.
OBJECTIVE: To determine the prevalence of intraoperative hemorrhage in a consecutive series of dogs undergoing patent ductus arteriosus (PDA) ligation at a veterinary teaching hospital, and to describe strategies to reduce the risk of ductus perforation and deal with hemorrhage when it occurs. STUDY DESIGN: Retrospective clinical study. ANIMALS: Sixty-four dogs. METHODS: The records of all dogs undergoing PDA ligation at the University Veterinary Center, Sydney between May 1989 and February 1998 were reviewed and the prevalence and nature of complications identified. RESULTS: Serious hemorrhage occurred in 4 of 64 dogs (6.25%) that underwent PDA ligation. In all cases, hemorrhage resulted from perforation of the craniomedial aspect of the ductus while attempting to expose the tips of the dissecting forceps. Hemorrhage was controlled in 3 dogs by clamping the main pulmonary artery, digital compression of the descending aorta, and completion of ductus ligation during an approximately 5-minute period of circulatory arrest. The remaining dog exsanguinated during an unsuccessful attempt to locate, clamp, and ligate the bleeding point. The mortality rate for PDA ligation was I of 64 dogs (1.6 %). CONCLUSIONS: The technique described in this report permits simple ligation of a range of different ductus morphologies in dogs of varying breeds, weights, and ages. In the event of serious hemorrhage, prompt ventricular outflow occlusion and ductus ligation followed by rapid whole blood transfusion is life saving in most cases.  相似文献   

18.
Objective— To report a technique for tube cystostomy placement via a minimally invasive inguinal approach and outcome in 9 dogs and 6 cats with urinary tract obstruction or detrusor atony.
Study Design— Case series.
Animals— Dogs (n=9) and cats (6).
Methods— Medical records (January 2004–January 2008) of dogs and cats that had tube cystostomy via an inguinal approach were reviewed. Retrieved data included signalment, diagnosis, surgical technique, and complications. Access to the bladder was through a muscle splitting approach in the inguinal region with the cystostomy tube placed through a skin incision made several centimeters proximal to this incision and secured in the bladder by a purse string suture. Cystopexy during closure of the muscle layers ensured secure closure and minimized the likelihood of uroabdomen if tube dislodgment occurred.
Results— Cystostomy tubes were placed in 5 cats as an emergency procedure for treatment of acute urinary tract obstruction or urethral rupture, and as an elective procedure in 9 dogs and 1 cat. No complications occurred during cystostomy tube placement. Postprocedural complications were minor (peristomal irritation in 2 dogs with latex catheters, catheter laceration, premature removal) and only occurred when tubes were retained for >4 weeks. Urinary tract infection at catheter removal in 6 dogs resolved with antibiotic administration.
Conclusions— An inguinal approach for cystostomy tube placement facilitated rapid catheter placement into the bladder with minimal soft tissue dissection. Cystopexy during abdominal wall closure provided peritoneal protection should premature dislodgement of the cystostomy tube occur.
Clinical Relevance— An inguinal approach should be considered for rapid tube cystostomy particularly in metabolically compromised animals.  相似文献   

19.
Objectives : To describe partial pancreatectomy using a bipolar vessel‐sealing device (BVSD) and compare this novel technique to the conventional suture‐fracture (SF) method for canine insulinoma. Methods : Pre‐, intra‐ and postoperative data of eight dogs with insulinoma, which underwent resection using the BVSD (LigaSure V), were prospectively collected and compared with those of eight randomly selected case‐matched patients that underwent resection using the conventional SF technique. Results : Mean surgical time was significantly (P=0·022) shorter in the BVSD (107 ±9 minutes) than in the SF (135 ±22 minutes) group. The BVSD technique was negatively associated with surgical time and duration of the hospitalisation period. Neither technique caused intraoperative complications, such as bleeding, collateral damage to adjacent tissues or problems with sealing or suturing the pancreatic tissue. Three dogs in the SF group and none in the BVSD group developed postoperative clinical signs associated with pancreatitis. Clinical Significance : BVSD is a safe and viable alternative to conventional methods of pancreatectomy for canine insulinoma. It provides the possibility to remove insulinomas in the pancreatic limbs and corpus with relative ease. BVSD pancreatectomy in dogs with insulinoma significantly decreases operative and hospitalisation times and is not associated with more clinical complications than SF pancreatectomy.  相似文献   

20.
OBJECTIVE: To describe a surgical technique for, and outcome after, treatment of radial fractures with biodegradable self-reinforced polylactide plates and metal screws, and external coaptation. STUDY DESIGN: Prospective clinical study. SAMPLE POPULATION: Eleven Toy breed dogs. METHODS: Radial fractures were repaired by application of a single or 2 stacked biodegradable self-reinforced polylactide plates (poly-L/D, L-lactide, stereocopolymer [LL-and DL-lactide ratio 70/30]; SR-PLA (70/30) implants) secured with metal screws, and light-weight external coaptation. Healing was evaluated clinically and by radiography at 2, 4, 6, 8, 9, 12, 24-26 weeks, and at 1 and 2 years. Owners were interviewed 3 years after surgery. RESULTS: Radial fracture lines disappeared within 4-14 weeks in 10 dogs; an implant failed in 1 dog. Ambulation was excellent for healed fractures. Excessive skin tension led to removal of implants in 1 dog and suture repair in another dog. No foreign body reaction from implant degradation was observed and the plate was usually no longer palpable at 2 years. One dog had a fracture through a screw hole at 1 year. CONCLUSION: Healing and complication rates after repair of radial fractures with SR-PLA (70/30) plates were considered similar or better than reported after repair with metallic plates or external fixation in Toy breed dogs. No radiographic signs of osteopenia were identified under the plate during follow-up. CLINICAL RELEVANCE: Biodegradable polylactide plates could be considered as an alternative to metal plates for radial fracture repair in Toy breed dogs, however available plates are likely not strong enough when used as a single plate. Implant removal is usually not needed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号