首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A 5-month-old female French bulldog was evaluated for the presence of a heart murmur. Through clinical and echocardiographic evaluations, a severe Type A pulmonary stenosis was diagnosed. Angiography during right ventricular catheterization for valvuloplasty revealed drainage from a persistent left cranial vena cava (PLCVC) into the left atrium; this was confirmed later by contrast echocardiography. This report is the first to describe this anatomical variant of a PLCVC in a dog.  相似文献   

2.
Difficulty was encountered with the insertion of a right atrial pacing lead via the left jugular vein during lead and pacemaker implantation in a clinically normal goat as part of an ongoing rapid atrial pacing – induced atrial fibrillation research project. Fluoroscopic visualization of an abnormal lead advancement path prompted angiographic assessment which revealed a persistent left cranial vena cava (PLCVC) and prominent coronary sinus communicating with the right atrium. Angiography facilitated successful advancement and securing of the pacing lead into the right side of the interatrial septum. Cardiac magnetic resonance imaging/magnetic resonance angiography (MRI/MRA) allowed further characterization of this rare venous anomaly. Even though PLCVC has been reported once in a goat, to the authors' knowledge this is the first report to include MRI/MRA characterization of PLCVC and prominent coronary sinus with successful cardiac pacemaker implantation using the PLCVC.  相似文献   

3.
A 2‐months‐old male German shepherd puppy was referred for regurgitation and delayed growth. Radiographic and endoscopic investigations revealed a precardiac megaoesophagus and oesophageal constriction at the level of the heart base. At post‐mortem examination, a specific form of persistent right aortic arch characterized by an aberrant left subclavian artery in combination with a ligamentum arteriosum originating at the aberrant left subclavian artery (PRAA‐SA‐LA) was detected. A complete‐type persistent left cranial vena cava (PLCVC) was also observed. This is the first report describing the association between PRAA‐SA‐LA and PLCVC in a dog with megaoesophagus.  相似文献   

4.
Objective: To describe successful treatment of third-degree atrioventricular (AV) block using temporary noninvasive transthoracic pacing and placement of a permanent transvenous pacemaker in a case of suspected lily-of-the-valley ( Convallaria majalis ) intoxication in a dog.
Case summary: A 2-year-old neutered male Beagle weighing 17.8 kg was presented to the emergency service for treatment of bradycardia, vomiting, and lethargy. An electrocardiogram revealed third-degree AV block that was nonresponsive to atropine. Ten hours after admission, the dog became obtunded. Treatment initially consisted of temporary noninvasive transthoracic pacing and eventually placement of a permanent transvenous pacemaker. The initial history did not suggest that the dog had access to any known cardiotoxins. However, C. majalis , which contains cardiac glycosides, was identified within the dog's environment and the dog's serum did contain digoxin or an immunologically cross-reactive compound.
New or unique information provided: This is the first reported successful management of C. majalis toxicosis in a dog. Temporary noninvasive transthoracic pacing was used in the management of this case as a safe and effective bridge to permanent pacemaker implantation.  相似文献   

5.
This paper describes the electrocardiographic, echocardiographic (two-dimensional, M-mode, contrast and Doppler) and non-selective angiocardiographic features in a 3 year old female Beagle with dilated coronary sinus due to persistent left cranial vena cava. Negative P waves in leads III and aVR and a positive P wave in lead aVL were seen. Echocardiographically, a hipoechoic circular structure was seen between the left atrium and the pericardium in the area where the coronary sinus is located. A velocity pattern with two peaks was obtained, one systolic with velocity = 0.44 ± 0.05 m/sec and the other diastolic with velocity = 0.27 ± 0.01 m/sec. By M-mode echocardiography, at level of the aorta and the left atrium, a linear structure was identified between the left atrium and the pericardium; this structure was characterized by phasic movements of the anterior wall during the cardiac cycle. Following a left cephalic vein injection of saline, bubbles were seen within the coronary sinus; when saline was injected into the right cephalic vein, bubbles were also seen within the coronary sinus and right atrium and ventricle. Non-selective angiocardiography confirmed a dilated coronary sinus with persistent left cranial vena cava. The right cranial vena cava was absent. The dog was clinically normal and the unusual vessel was an incidental finding.  相似文献   

6.
Two cats with bradycardia and syncope were treated by permanent pacemaker implantation. Cat 1 had multiple episodes of syncope intermittently over a 10-month period and then multiple episodes within 24 hours; cat 2 had episodes of collapse over a 3-month period. Clinical signs included disorientation, vocalization, and collapse. High-grade second-degree AV block was recorded in both cats, with left and right bundle branch block in cat 1 and right bundle branch block in cat 2. Neither responded to pharmacologic therapy. In cat 1, an epimyocardial electrode was implanted into the left ventricular apex by a ventral abdominal transdiaphragmatic surgical approach. Cat 2 had a permanent smooth endocardial pacing lead introduced into the fight external jugular vein and directed into the right ventricular apex. Both cats were clinically normal within three days after implantation. Complications in cat 2 included failure of pacemaker capture, endocardial lead dislodgement, and pulse generator pocket seroma. Cats with symptomatic bradycardia caused by second-degree and third-degree AV block can be effectively treated by pacemaker implantation by surgical endomyocardial or perivenous endocardial lead placement.  相似文献   

7.
A bicuspid aortic valve (BAV) demonstrating moderate valvular stenosis and mild insufficiency was identified in an asymptomatic 1-year-old male cryptorchid English bulldog by transthoracic and transesophageal echocardiography. The BAV was most consistent with type 3 morphology, based upon human classification. Pulmonary valve dysplasia with mild pulmonary stenosis and a suspected persistent left cranial vena cava were also identified. Although BAV is the most common congenital cardiac malformation in humans, it is rare in the dog.  相似文献   

8.
A 1.5-year-old mixed breed dog was presented for evaluation of arrhythmia and a cranial mediastinal density was noted on thoracic radiographs. The density was determined to be a cranial vena cava aneurysm based on ultrasonographic and angiographic testing. No treatment was initiated and the dog remains asymptomatic for the cranial vena cava aneurysm at 6 years of age. Although rare, cranial vena cava aneurysm should be a differential diagnosis for dogs with cranial mediastinal abnormalities on thoracic radiographs.  相似文献   

9.
Inferior vena cava obstruction, a rare but serious complication of transvenous pacemaker lead placement in humans, has not been reported in dogs. We describe this complication in a dog that developed ascites 8 months after pacemaker implantation. Radiography disclosed a loop of redundant lead within the caudal vena cava (CVC), and angiography demonstrated obstruction to blood flow. Withdrawal of the loop from the CVC did not restore blood flow. Persistent obstruction was suspected secondary to fibrosis resulting from vascular damage caused by the loop of lead. Angioplasty of the CVC obstruction restored blood flow and resolved the dog's clinical signs.  相似文献   

10.
Permanent Transvenous Pacemaker Implantation in Forty Dogs   总被引:1,自引:0,他引:1  
Permanent transvenous cardiac pacemakers were implanted in 40 dogs. Electrocardiographic diagnoses included persistent atrial standstill (3 dogs), sick sinus syndrome (8 dogs), and high-grade second-degree or third-degree atrioventricular (AV) block (29 dogs). Thirteen dogs were alive and well 4 to 42 months after pacemaker implantation (mean, 16.9 months). The mean and median survival times of the 26 dogs that died or were euthanatized during the study were 17.9 months and 13 months, respectively. Most of these dogs succumbed to problems unrelated to the arrhythmia and pacemaker implant. One dog was lost to follow-up. Complications associated with permanent transvenous pacemaker implantation included lead dislodgement, infection, hematoma formation, skeletal muscle stimulation, ventricular arrhythmia, migration of the pulse generator, and skin erosion. Lead dislodgement was the most common complication, occurring in 7 of 9 dogs paced using untined electrode leads and in 6 of 30 dogs paced using tined leads. Lead dislodgement did not occur in the only dog paced using an actively fixed endocardial lead. It was concluded that permanent transvenous cardiac pacing is a feasible, less traumatic alternative to epimyocardial pacing in dogs, but that successful use of this technique requires careful implantation technique and anticipation of the potential complications.  相似文献   

11.
A 7.5-year-old castrated male ferret (Mustela putorius furo) was diagnosed with third-degree atrioventricular (AV) block. A monopolar epicardial pacemaker system was implanted, resulting in a regular, paced cardiac rhythm with third-degree AV block at 140 beats per minute. Over the next 2 months, the ferret developed anorexia, interstitial pneumonia, intermittent diarrhea, and hind-limb weakness and had a slow and progressive recovery. The ferret developed clinical signs of congestive heart failure 4 months after the surgery, resulting in its death 3 weeks later. Necropsy results attributed the death to cardiac failure due to extensive myocardial mineralization. To the authors' knowledge this is the first published report of surgical report of surgical pacemaker implantation in a ferret.  相似文献   

12.
A four-year-old, sexually intact, male dachshund was diagnosed with pulmonary blastomycosis. Itraconazole was administered for 60 days, and the dog was considered to be disease-free at three- and 12-month reevaluations. Two years following discontinuation of itraconazole, the dog developed a granuloma of the cranial vena cava resulting in chylothorax and cranial vena caval obstruction. To the authors' knowledge, this is the first case of a blastomycotic granuloma involving the vena cava reported in the dog. Blastomycosis should be considered as a differential diagnosis for both chylothorax and cranial vena caval syndrome in the dog.  相似文献   

13.
This report describes transient trifascicular block in three cats presented with lethargy and inappetence, and elevated cardiac troponin I concentrations.The electrocardiogram (ECG) of cat 1 showed a sinus rhythm with pronounced first-degree atrioventricular (AV) block, right bundle branch block, and left anterior fascicular block. The ECG of cat 2 showed truncular left bundle branch block alternating with left anterior fascicular block coupled with prolonged PR intervals, second-degree heart block, and paroxysmal third-degree AV block. The ECG of cat 3 showed first-degree AV block with concomitant right bundle branch block. The diagnosis of trifascicular block was made when paroxysmal third-degree AV block was documented.All cats recovered with medical management within weeks. Each cat resumed a sinus rhythm. Elevated cardiac troponin I concentrations suggested myocarditis that improved.  相似文献   

14.
Throughout its life, a 1-year-old Doberman Pinscher dog had had gastrointestinal disorders and episodes of circling. It was less active than its littermates, and it usually seemed lethargic. When 3 months old, the pup had been anesthetized for ear cropping and it had remained anesthetized for 32 hours. Behavioral problems were apparent when the dog was 11 months old. Two weeks later the behavioral problems accentuated to the point that the dog developed "temper tantrums" and became aggressive toward its owner. On the basis of clinicopathologic and contrast radiographic findings, hepatoencephalopathy due to persistent patent ductus venosus was diagnosed and the dog was euthanatized. Situs inversus abdominalis and multiple vascular anomalies were found at necropsy. Gross and microscopic studies of the viscera were correlated with corrosion casts of the vasculature. In addition to changes in organ position, 3 spleens and malformation of the pancreas were observed. Vascular anomalies were: (1) The portal vein was contiguous with the common hepatic vein by way of a patent ductus venosus; branches of the portal vein were not given off to the liver; (2) the caudal vena cava was continued by the azygos vein, and a cranial segment of the caudal vena cava was absent; (3) the hepatic artery was larger than normal; (4) the left gastric artery arose anomalously from the cranial mesenteric artery; and (5) histologic and radiographic study of the liver did not reveal any interlobular branches of the portal vein; however, hypoplastic branches of the gastroduodenal vein did enter the liver and were demonstrated on a corrosion cast.  相似文献   

15.
A 4-mo-old female white lion (Panthera leo) cub was presented with a 2-wk history of persistent postprandial regurgitation, mild dyspnea, and poor weight gain. The cub was weak and thin but otherwise alert. Survey and contrast radiography revealed a large dilated esophagus cranial to the heart base, with an esophageal filling defect present at the level of the fourth thoracic vertebra. A vascular ring anomaly was tentatively diagnosed. Exploratory thoracotomy revealed a double aortic arch and a persistent left vena cava. The left aortic arch was ligated and divided, and recovery was uneventful. A single episode of regurgitation occurred within the first postoperative month, and the cub gained 5.5 kg in weight during the same time period. Neither double aortic arch nor persistent left vena cava has been reported in a nondomestic felid.  相似文献   

16.
OBJECTIVES: To document the outcome, survival and complications involved in pacemaker implantation in dogs in a retrospective study. METHODS: Case records for all dogs in which pacemaker implantation was performed were reviewed. RESULTS: A total of 104 dogs underwent pacemaker implantation. Dogs were presented with atrioventricular (AV) block (71), sick sinus syndrome (25) or vasovagal syncope (eight). Age at presentation varied from six months to 13 years with a median age of seven years and two months. The Labrador was the most commonly represented breed (17 cases). All but one dog survived pacemaker implantation, with 93 showing resolution of their clinical signs while 10 dogs showed intermittent residual signs. One-, three- and five-year survival estimates were 86, 65 and 39 per cent, respectively. Major complications after implantation were documented in 15 dogs and three of these led to fatalities. Minor complications were noted in 23 dogs. Sudden death occurred in six dogs three to 55 months following successful pacemaker implantation. CLINICAL SIGNIFICANCE: Transvenous pacemaker implantation was successful in reducing or eliminating clinical signs in over 90 per cent of dogs with third-degree atrioventricular (AV) block or sick sinus syndrome. In dogs with vasovagal syncope, six of eight dogs had greatly reduced frequency of collapse and two became asymptomatic. Although the procedure was associated with complications, these were rarely life threatening and good survival was documented in the majority of cases.  相似文献   

17.
Dysplasia of the tricuspid valve in 14 dogs and 13 cats was studied. The clinical, electrocardiographic, radiographic, hemodynamic, angiocardiographic, and pathologic findings were reviewed in each species. Alterations of the tricuspid valve complex included long, thick septal leaflets adhered to the septum; absent or short, stout fused chordae tendineae; hypertrophic fused papillary muscles; insertion of papillary muscles directly into the lateral leaflets; incomplete development of the valvular tissue; and enlargement of the right atrium and ventricle. Additional intracardiac anomalies included malformation of the mitral valve complex (5 dogs and 3 cats), ventricular septal defect (3 dogs and 3 cats), pulmonary stenosis (1 dog and 1 cat), aortic stenosis (1 dog and 1 cat), and persistent left cranial vena cava (1 dog).  相似文献   

18.
Two dogs, one immature and one adult, were presented with a history of progressive ascites. In a third, immature dog, increasing exercise intolerance had been noted. Echocardiography demonstrated a partition in the right atrium (cor triatriatum dexter) and echocontrast studies documented normal flow from the cranial vena cava into the right atrium and ventricle. A saphenous vein contrast study demonstrated flow from the caudal vena cava into an accessory right atrial chamber (sinus venarum). The sinus venarum communicated with the true right atrium via a small defect in the atrial membrane in one dog, and additionally with the left atrium via a right-to-left shunting foramen ovale in the other dogs. All defects were visualised on angiographic studies by selective catheterisation of the caudal vena cava via the femoral vein. Balloon dilatation of the defect was then performed using a small followed by a larger balloon angioplasty catheter to enlarge the defect in the atrial membrane. Clinical signs improved within days and were sustained in the long-term in all cases.  相似文献   

19.
A spayed female dog was evaluated because of edema of the ventral cervical region, lethargy, cough, and reduced exercise tolerance. Invasive thymoma and cranial vena cava syndrome were diagnosed by use of ultrasound-guided fine-needle biopsy and contrast-enhanced helical computed tomography. Resection of the cranial vena cava and an autogenous jugular vein graft were used for restoration of normal venous return to the right atrium and alleviation of the cranial vena cava syndrome.  相似文献   

20.
A complete left cranial vena cava (LCVC) was found in a normal horse. The LCVC was well developed, but there was a complete absence of the right cranial vena cava. The azygous vein was normally distributed on the right side of the thoracic vertebral bodies but passed ventral to the aortic arch to empty into the cranial vena cava on the left close to the origin of the aortic arch. The LCVC passed over the dorsal aspect of the left atrium to reach the coronary sulcus on the caudal aspect of the heart. The LCVC opened into the right atrium via a 5 cm diameter orifice (orifice of coronary sinus). The vena cordis magna joined the LCVC 6 cm from the orifice of the coronary sinus. Complete dissection of the horse revealed no other developmental abnormalities. This case is compared with similar cases in the literature.  相似文献   