首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Six enterotomies 3 cm long, spaced at 3 cm intervals, were made in the antimesenteric border of the pelvic flexure of the ascending colon in five adult horses. Ten incisions each were sutured with a Utrecht pattern (single layer), a full-thickness simple continuous oversewn with a Cushing pattern (two layer), and a mucosal simple continuous with a seromuscular simple continuous oversewn with a Cushing pattern (three layer). In all horses, chromic gut and polyglactin 910 were each used once for each pattern. On day 6, the pelvic flexure was excised and the colonic vessels were injected with a radio-opaque mass. Sections of each enterotomy were studied by light microscopy and high detail radiography. The single-layer closure led to serosa-to-mucosa healing and a thin bowel wall, and the three-layer closure resulted in distortion of the bowel wall by hematoma formation and submucosal contamination with ingesta. The two-layer closure resulted in good alignment and improved healing. There was less inflammatory reaction with polyglactin 910 than with chromic gut.  相似文献   

2.
OBJECTIVE: To describe and compare a simple continuous suture pattern with a simple interrupted pattern for enterotomy closure or end-to-end intestinal anastomosis. DESIGN: Retrospective study. ANIMALS: 58 dogs and 25 cats that underwent enterotomy or intestinal resection and anastomosis. PROCEDURE: Signalment, surgical procedure, suture pattern, suture material, confirmation of dehiscence, and follow-up were reviewed. Groups were compared by procedure (anastomosis or enterotomy) and by suture pattern. RESULTS: 57 animals underwent continuous closure; 26 had interrupted closure. Only polydioxanone or polypropylene suture materials were used. Overall, 81 (98%) animals had no signs of intestinal dehiscence and survived > 2 weeks. Two animals had confirmed dehiscence after foreign body removal, 1 of 57 (2%) after continuous closure, and 1 of 26 (4%) after interrupted closure. CLINICAL IMPLICATIONS: The simple continuous closure pattern is an acceptable alternative to simple interrupted closure for small intestinal anastomosis or enterotomy closure.  相似文献   

3.
Esophagotomies were performed on 36 dogs and closed with 3-0 polydioxanone in double-layer simple interrupted, single-layer simple interrupted, or single-layer simple continuous patterns. The operative time was shortest for single-layer simple continuous closure, followed by single-layer simple interrupted and double-layer simple interrupted, respectively. Three dogs with each suture pattern were euthanatized at hours 0 and 1, and days 4 and 28 after surgery. The esophagotomy incisions were subjected to bursting strength testing and examined microscopically. The bursting wall tension was higher for all three suture pattern groups at 28 days than at 0 and 1 hour. The double-layer closure had higher bursting wall tension than the single-layer closures at 0 hour and 4 days. Single-layer simple continuous closure had the lowest bursting wall tension for each time period. Single-layer simple interrupted closure had the highest bursting wall tension at 28 days. Microscopic examination revealed close approximation of tissue planes for the double-layer closure and mucosal ever-sion for the simple interrupted and simple continuous single-layer closures. Healing was superior histologically with the double-layer closure.  相似文献   

4.
OBJECTIVE: To evaluate single and double layer end-to-end anastomosis in equine jejunum. STUDY DESIGN: Experimental in vitro study. ANIMALS: Mid-jejunal sections from 12 adult horses without gastrointestinal disease. METHODS: Jejunal end-to-end anastomoses were performed by a continuous Lembert pattern or a simple continuous pattern oversewn with a Cushing pattern. Jejunal segments were distended with fluid at 1 L/min, and intraluminal pressure at failure, and mode of failure were recorded. Bursting pressure and bursting wall tension were calculated. Anastomosis construction time and degree of luminal reduction were recorded. Results- Single layer anastomoses were constructed in less time than 2-layer anastomoses. Both anastomotic techniques resulted in luminal reduction compared with control tissue; however, the reduction was smaller with a 1-layer continuous Lembert anastomosis. No differences were noted in bursting pressure or bursting wall tension between groups. CONCLUSIONS: Anastomosis using a 1-layer continuous Lembert pattern resulted in a larger stoma, was faster to perform, and as strong as a 2-layer anastomosis. CLINICAL RELEVANCE: Use of a 1-layer continuous Lembert pattern for jejunojejunosotomy may be beneficial by decreasing anastomosis time and produce a larger stoma than a 2-layer anastomosis.  相似文献   

5.
The knot security of chromic gut, polyglycolic acid, polyglactin 910, polydioxanone, polypropylene, and monofilament nylon size 2-0 suture materials were tested biomechanically in vitro. Twenty reproducible knots were tied and incubated in canine serum at 37 degrees for 24 hours before testing. A "secure knot" was defined as a knot that, when tested to failure, broke rather than untied by slippage. The minimum number of throws necessary to make a secure, snug (1500 g tension) square knot was three for gut, polyglycolic acid, polyglactin 910, and polypropylene and four for polydioxanone and nylon. All throws including the first were counted. With all suture materials tested, surgeon's knots were as secure as square knots. Only gut, polyglycolic acid, and polydioxanone granny knots were as secure as square knots; no loosely tied (500 g tension) asymmetric square knots were as secure as snug square knots, and only polydioxanone and polypropylene loose square knots were as secure as snug square knots. Square knots used to start a continuous pattern required one additional throw with gut, polydioxanone, and nylon. Square knots used to end a continuous pattern required two to three additional throws with all materials tested.  相似文献   

6.
This study compares the healing of oronasal defects created by partial maxillectomy when closed using two different suture materials and two different suture patterns. In experiment 1, 24 dogs were divided into four equal groups. Partial maxillectomy was performed on each dog and was closed using either a two-layer simple interrupted suture pattern (12 dogs) or a modified Mayo mattress pattern (12 dogs) with either polyglactin 910 (12 dogs) or polypropylene (12 dogs) sutures. On the seventh postoperative day, the dogs were euthanized, suture line bursting pressures were measured, and wound healing was evaluated grossly and histopathologically. Suture line dehiscence occurred in one dog from each of the four groups. These were the only dogs in which electrocoagulation had been used. The healing of suture lines closed with the two-layer simple interrupted pattern was superior to that of those closed with the modified Mayo mattress pattern based on the degree of gross oral ulceration, suppurative inflammation, fibrosis and oral epithelial covering at the suture line, and the number of necrotic sites in the adjacent tissue. The healing of suture lines closed with polypropylene was superior to that of those closed with polyglactin 910 based on suture line bursting pressures and the degree of suppurative inflammation and tissue necrosis at the suture sites. In Experiment 2, partial maxillectomies were performed on four dogs, and closure was achieved using a two-layer simple interrupted suture pattern with either polyglactin 910 (two dogs) or polypropylene (two dogs). On the 30th postoperative day, the dogs were euthanized, and wound healing was evaluated grossly and histopathologically. All suture lines were well healed. All polyglactin 910 oral sutures were absent, while all polypropylene oral sutures were still present.  相似文献   

7.
OBJECTIVES: To compare arterial bursting pressure after vessel closure using a vessel-sealing device (LigaSure Atlas Laparoscopic Sealer/Divider Instrument; Valleylab, Boulder, CO), a ligate-and-divide stapling device (LDS), and 2-0 polydioxanone suture. To evaluate the LigaSure Atlas as a method for ligation of the mesenteric vasculature during small intestinal resection in normal horses. STUDY DESIGN: Experimental study. ANIMALS: Part A: jejunal segments from 19 horses. Part B: 6 horses, aged 1 to 18 years, weighing 330 to 509 kg. METHODS: Part A: Jejunal segments with mesenteric vessels were collected from 19 horses. After closure by 1 of 3 methods (LigaSure Atlas, LDS, 2-0 polydioxanone) arteries were cannulated, and bursting pressure was measured by incrementally increasing intraluminal pressure until failure. Part B: Six horses had jejunal resection and anastomosis using a vessel-sealing device (LigaSure Atlas) to provide hemostasis of the mesenteric vasculature. Horses were monitored clinically for 4 weeks. RESULTS: Part A: Mean +/- SEM bursting pressure after 2-0 polydioxanone ligation (1,014.50 +/- 279.05 mm Hg) was significantly greater than mean bursting pressure after LigaSure (554.25 +/- 228.79 mm Hg), which was significantly greater than the mean bursting pressure after LDS (373.25 +/- 183.69). Part B: No major operative or postoperative hemorrhage occurred after application of the LigaSure Atlas for sealing and transecting mesenteric vasculature during small intestinal resection in normal horses. CONCLUSIONS: The LigaSure Atlas appears to be a safe method for hemostasis of the mesenteric vasculature during small intestinal resection in normal horses. CLINICAL RELEVANCE: Benefits of the LigaSure Atlas vessel-sealing device include reduced time required to provide hemostasis, acceptable arterial bursting pressure, no remaining foreign material, and no risk for ligature slippage. In our experience, use of the LigaSure Atlas during small intestinal resection and anastomosis in horses is safe for ligation of vessels less than or equal to 7-mm diameter.  相似文献   

8.
OBJECTIVE: To determine the bursting strength of ventral median abdominal incisions closed by either simple continuous or inverted cruciate suture patterns. STUDY DESIGN: Experimental. ANIMAL OR SAMPLE POPULATION: Twelve equine cadavers. METHODS: A 25 cm ventral median incision was made through the linea alba and a 200 L polyurethane bladder was placed within the abdomen. Either a simple continuous or an inverted cruciate pattern using 3 polyglactin 910 with a bite size and suture interval of 1.5 cm was used to close linea incisions. Closure time was recorded for each pattern. The bladder was inflated with air at 40 L/min, and the pressure at body wall failure recorded. The length of suture used for wound closure and the wound failure modes were recorded. Deviation from the linea (cm), total suture length (cm), suture length to wound length ratio (SL:WL), closure time (min), bursting pressure (mm Hg), and failure modes were compared between groups using Welch-Aspin t-tests. The effects of independent subject variables were assessed for possible effects on bursting strength using analysis of covariance. RESULTS: Mean bursting pressure was significantly greater for the simple continuous pattern than for the inverted cruciate pattern (P = .01). Significantly less suture material (P = .0002) was required with the continuous pattern than with the inverted cruciate pattern. Mean closure time, SL:WL, deviation from the linea, and failure modes were not significantly different between groups. No significant effects were noted for independent variables in both groups on bursting strength. CONCLUSIONS: In this model, a simple continuous closure pattern for ventral median abdominal incisions was stronger than an inverted cruciate pattern. A simple continuous pattern leaves less foreign material in the wound, which may be of benefit in reducing incisional complications. CLINICAL RELEVANCE: Use of a continuous closure pattern for the linea alba may offer greater wound security during episodes of increased intra-abdominal pressure in horses.  相似文献   

9.
Swelling and inflammation along the incision line were observed after elective ovariohysterectomy in 22 of 66 cats in a retrospective study. In a prospective study of 99 feline abdominal incisions closed with surgical gut, polyglactin 910, or polydioxanone, with and without subcutaneous closure, the least inflammation occurred when the linea alba was sutured with polyglactin 910 and the subcutaneous tissues were not sutured. Histologically, reactions in the linea alba of 12 other cats progressed from purulent to fibromononuclear to fibrous within 14 days after closure with gut, polyglactin 910, and polydioxanone. Microscopic evidence of seroma formation in 9 of 12 animals in which the subcutaneous tissue was not sutured suggested that surgical closure of subcutaneous dead space was indicated. The inflammatory reaction did not appear to be related to any one suture material as reactions were seen with all of them.  相似文献   

10.
This study compared incisional complications after ventral midline laparotomy using 2 absorbable suture materials for apposition of the linea alba in sheep. The linea alba of 93 yearling sheep was sutured by 3 veterinarians in a simple continuous pattern using either polyglactin 910 (PG910; group PG) or polydioxanone (PDS; group PD). A blinded observer assessed surgical sites at the time of suture removal. Multivariate logistic regression was used to assess the association between incisional complications and variables (suture material used, veterinarian, skin suture removal time). The odds of incisional complications did not vary significantly with the type of suture material used (P = 0.11), veterinarian (P = 0.61) or skin suture removal time (P = 0.36). Most incisional complications were cutaneous suture sinus formation. Either PG910 or PDS may be used for linea alba closure in sheep.  相似文献   

11.
Our objective was to compare thoracoabdominal (TA Premium™ 90) stapled enterotomy closure to traditional hand-sewn closure, using time to perform the technique, luminal diameter, and bursting pressure in ex-vivo specimens. The pelvic flexures of 13 client-owned horses were harvested. Each pelvic flexure had 1 enterotomy performed; 6 were closed via staples, 7 closures were hand-sewn. Luminal diameter at the enterotomy site was assessed via contrast radiography performed pre-and post-enterotomy. Bursting pressure of the closure was assessed by continuous manometry during rapid infusion. Time to perform stapled closure was significantly shorter than hand-sewn closure (P < 0.0001). Percent reduction of luminal diameters was significantly decreased in stapled specimens (P = 0.034). There was no significant difference in bursting strength between closure techniques (P = 0.196). In conclusion, stapled enterotomy closure offers statistically significant reduction in closure time and better maintains pre-enterotomy luminal diameter without reducing biomechanical strength, compared to a double layer hand-sewn closure.  相似文献   

12.
Objective: To compare the mechanical, knotting, and absorption properties of 3 synthetic absorbable suture materials (polyglactin 910, polydioxanone, poliglecaprone 25) from 2 different manufacturers (Huaiyin Medical Instruments Co. Ltd. and Ethicon Inc.). Sample Population: Suture material samples from the same manufacturing lot for each suture type and manufacturer. Methods: Part 1: 10 samples of each suture were incubated in bovine serum and tested for ultimate load and stiffness at days 0, 1, 7, 14, 21, and 28. Part 2: 10 knotted samples were similarly evaluated, without incubation. Results: Huaiyin polydioxanone had a greater (P<.001) ultimate load on days 0, 1, and 7; and a consistently greater stiffness for the duration of the study, compared with the Ethicon polydioxanone. Ethicon poliglecaprone 25 had a greater ultimate load on days 0, 1, 7 (P<.001); on day 21 Huaiyin had a greater ultimate load. Ethicon poliglecaprone had greater stiffness on days 0, 1, 7 (P<.001). Ethicon polyglactin 910 had a greater (P<.001) ultimate load at all times and a greater stiffness (P<.001) at days 0, 1, 7, and 14 compared with Huaiyin polyglactin 910. Huaiyin polydioxanone and polyglactin 910 had greater knot breaking strengths than Ethicon equivalents (P<.001). Conclusion: Differences in mechanical properties exist between nominally identical suture materials from different manufacturers.  相似文献   

13.
The macroscopic and histological appearance of jejunal antimesenteric incisions approximated with two different absorbable suture materials (monofilament versus multifilament) and three closure techniques (appositional single layer, crushing single layer, and double layer) were compared in healthy dogs at 14 or 28 days, postoperatively. No significant differences between the two suture materials were observed for most of the macroscopic or histological variables. However, the monofilament suture material caused significantly more fibrous tissue reaction in the muscular layer of the jejunum than did the multifilament suture material. Of the three enterotomy closure techniques used in this study, the appositional single-layer method proved to be the best. The double-layer closure method caused a significant decrease in the incisional circumference, the relative circumference, and volume of the jejunum, and a significant increase in jejunal wall thickness. Our findings suggest that canine jejunal enterotomy incisions can be closed using an appositional suture pattern with relatively rapidly absorbable monofilament suture material. The use of double-layer suture patterns for closure of jejunal enterotomy incisions should be avoided because the size of the intestinal lumen may be reduced.  相似文献   

14.
Summary

The macroscopic and histological appearance of jejunal antimesenteric incisions approximated with two different absorbable suture materials (monofilament versus multifilament) and three closure techniques (appositional single layer, crushing single layer, and double layer) were compared in healthy dogs at 14 or 28 days, postoperatively. No significant differences between the two suture materials were observed for most of the macroscopic or histological variables. However, the monofilament suture material caused significantly more fibrous tissue reaction in the muscular layer of the jejunum than did the multifilament suture material. Of the three enterotomy closure techniques used in this study, the appositional single‐layer method proved to be the best. The double‐layer closure method caused a significant decrease in the incisional circumference, the relative circumference, and volume of the jejunum, and a significant increase in jejunal wall thickness. Our findings suggest that canine jejunal enterotomy incisions can be closed using an appositional suture pattern with relatively rapidly absorbable monofilament suture material. The use of double‐layer suture patterns for closure of jejunal enterotomy incisions should be avoided because the size of the intestinal lumen may be reduced.  相似文献   

15.
Reasons for performing study: Incisional complications are a major post operative challenge following ventral midline exploratory celiotomy for abdominal pain in horses. They lead to discomfort, prolonged hospitalisation, longer recovery times and increased cost; therefore, investigation of preventative procedures are warranted. Objectives: To determine the clinical effect of antibacterial (triclosan) coated 2‐0 polyglactin 910 suture material on the likelihood of incisional infections when used for closure of subcutaneous tissue following ventral midline celiotomies in horses. Methods: One hundred horses undergoing exploratory celiotomy assigned at random to one of 2 groups. In the control group coated 2‐0 polyglactin 910 (Vicryl) was used for apposition of the subcutaneous tissue in a simple continuous pattern and, in the study group, antibacterial (triclosan) coated 2‐0 polyglactin 910 suture material (Vicryl Plus) was used. Post operatively an elastic adhesive abdominal bandage was applied, changed and the incision was inspected by a clinician blinded to the study protocol at 24–36 h and 6–9 days post operatively. Outcomes of interest were evidence of incisional pain, incisional oedema, sheath/udder oedema, incisional drainage, hernia formation and dehiscence. Results: Antibacterial‐coated suture material did not decrease the likelihood of incisional complications in 100 horses. Conclusions: A beneficial effect on ventral midline incisions in 100 horses was not evident by using antibacterial‐coated suture material. Potential relevance: Lack of effectiveness of antibacterial‐coated suture material in equine ventral midline closure after exploratory celiotomy and the observed potential adverse effects suggest that further clinical investigations are needed before using such material routinely on horses.  相似文献   

16.
Objective— To evaluate the effect of 6 different knotting methods on the mechanical properties of 3 large absorbable suture materials used in large animal surgery. Study Design— In vitro mechanical study. Sample Population— Knotted suture loops (n=15 per group). Methods— Suture loops were created between two low‐friction pulleys with either 2 polydioxanone, 2 polyglactin 910 or 3 polyglactin 910. Strands were tied using 1 of 6 knotting technique: square knot, surgeon knot, clamped surgeon's knot, sliding half‐hitch knot (HH), Delimar knot and self‐locking knot (SLK). A single cycle to failure test was performed on each suture loop with a distraction rate of 100 mm/min. Failure modes were evaluated and breaking strength, elongation to failure and stiffness were compared. Results— All loops except two HH failed at the knot by acute breaking. The double‐stranded SLK was both stronger and stiffer than all other knots for each suture material. Clamping the first throw of the surgeon knot decreased load to failure significantly (143.11 ± 8.64 N) compared with not clamping (159.21 ± 6.14 N) for polydioxanone. Stiffness and elongation to failure were respectively lower and increased for 2 polydioxanone compared with both polyglactin 910 materials for all knotting techniques. Conclusions— Knotting techniques do influence structural properties of suture loops. The double strand loop conferred stiffer and stronger properties to the SLK Clinical Relevance— Clamping the first throw of polydioxanone should be avoided when tying a suture under tension even using large diameter suture materials. Using a SLK might be considered as a useful alternative when excessive tension is present.  相似文献   

17.
OBJECTIVE: To determine a hand-tied ligature knot configuration, suture size, and suture type that would be an acceptable substitute to commercially available ligature knots for use in equine laparoscopic surgery. STUDY DESIGN: Three-factor ANOVA with the fixed effects being suture type, suture size, and knot type. The dependent variable was ligature security (load to failure). METHODS: Commercially available Endoloop and 4 hand-tied slipknot ligatures were compared with a 4-layer square knot. The hand tied ligature knots tested were the 4S modified Roeder knot, the Brooks knot, the modified Roeder knot, and the Weston knot. Two suture sizes (0, 2) of each of 2 suture types (polydioxanone, polyglactin 910) were tested with each hand tied knot. Two types (polydioxanone, polyglactin 910) of size 0 Endoloop were tested. Twenty repetitions of each knot suture type were tested for force to yield on a materials testing machine. Statistical analysis consisted of a 3-way ANOVA with individual comparisons made using the Bonferroni method. Significance was P< or = .05. RESULTS: Only the 4S modified Roeder knot in 2 polydioxanone (103 N) was comparable with the breaking strength of the square knots (157 N). All other knot suture combinations tested were significantly weaker than the square knot (range, 2-18 N). CONCLUSION: For equine laparoscopy, a 2 polydioxanone 4S modified Roeder knot would be an acceptable alternative to the commercially available Endoloop. CLINICAL RELEVANCE: Laparoscopic slip knots are commonly used in equine laparoscopic surgery. Various knot configuration and suture size and type combinations will affect the security of the slip knot.  相似文献   

18.
Intestinal wounds require precise closure after intestinal biopsy, enterotomy, or enterectomy in small animals. Preexisting factors such as intra‐abdominal sepsis and hypoalbuminemia as well as poor surgical technique increase the risk of intestinal dehiscence, with considerable negative impact on patient morbidity and mortality. Live dog studies have demonstrated the dangers of mucosal eversion especially in the septic abdomen. Approximating patterns preserve luminal diameter, heal optimally, and have equal bursting strength compared with inverting patterns after 24 hours. Simple interrupted and simple continuous suture patterns and disposable skin staples are established alternatives for manual wound closure. Knotless quilled suture currently used in laparoscopic gastropexy techniques shows bursting strength equal to monofilament sutures in dog cadaveric intestine. Dehiscence rates with hand sewn vs titanium automated stapling anastomosis are similar in uncomplicated cases; however, auto stapling devices may be the preferred method of anastomosis when preexisting abdominal sepsis is present and when patient size allows it. Regardless of the technique, current standard of care involves leak testing and omental wrapping, followed by early postoperative feeding. The past decade has ushered in an exciting new era of laparoscopic assisted techniques that have the potential to reduce postoperative pain and patient morbidity. An understanding of these applications will establish the future of minimally invasive small animal intestinal surgery for veterinary specialists. In summary, surgeons have a variety of methods at their disposal for optimal clinical outcome in small animal intestinal surgery.  相似文献   

19.
Objective: To test single cycle to failure tensile strength characteristics of 6 suture material–pattern combinations in equine superficial digital flexor (SDF) tenorrhaphy, specifically to compare a 10‐strand modification of the Savage core suture technique with the 3‐loop pulley technique. Study Design: Ex vivo mechanical experiment comparing 3 different suture patterns with 2 different materials. Sample Population: Forelimb and hindlimb SDF tendons (n=48) harvested from adult Thoroughbred and Standardbred horses of mixed age and gender. Methods: Six suture material–pattern combinations were evaluated: (1) 10‐strand Savage, size 2 polydioxanone (PDS); (2) 10‐strand Savage, size 2 polyglactin 910 (PG910); (3) 10‐strand Savage, size 2 PDS with Lin‐locking epitenon suture, size 2–0 PDS; (4) 10‐strand Savage size 2 PG910 with Lin‐locking epitenon suture, size 2–0 PDS; (5) 3‐loop pulley, size 2 PDS; and (6) 3‐loop pulley, size 2 PG910. Maximum load at failure (N), gap at failure (mm), and mode of failure (suture breakage or pull through) were evaluated for each of the 6 suture material–pattern combinations and underwent statistical analysis to determine significance of differences and interactions of the measured data. Results: The 10‐strand Savage technique failed at a mean load of 872 N (804–939, 95% CI). The 10‐strand Savage with Lin‐locking failed at a significantly greater mean load of 998 N (930–1065, 95% CI). The 3‐loop pulley pattern failed with a mean load of 337 N (270–405, 95% CI). There were significant interactions between the technique and suture material used. Conclusion: The 10‐strand Savage technique for repair of transected cadaver SDF tendons has superior strength characteristics with or without the epitenon suture when compared to the 3‐loop pulley. Suture material and pattern interactions were observed with PG 910 conferring higher strength for the 10‐strand Savage whereas PDS did so for the 3‐loop pulley.  相似文献   

20.
Autogenous lamellar corneal grafting in dogs   总被引:1,自引:0,他引:1  
Lamellar, autogenous, corneal grafts were performed on 9 clinically normal dogs (1 eye in each of 2 dogs and both eyes in each of 7 dogs) and 7 dogs with corneal disease (1 eye in each dog). Nylon, polyglycolic acid, polyglactin 910, and polydioxanone suture materials were used in 8-0 to 10-0 sizes. The eyes of the normal dogs were examined weekly for up to 16 weeks; corneal endothelium was reestablished in all eyes by 6 weeks after surgery. The eyes of the dogs with corneal disease were reexamined periodically for up to 9 months. Twenty-two of 23 (95.7%) grafts were considered successful in that they were translucent, and the dogs were able to see after surgery. The suture materials that caused the least tissue reaction were nylon and polyglactin 910. This procedure is indicated for chronic descemetoceles and other perforating corneal disease. It has the advantage of rapidly resolving severe corneal disease, with a high degree of success.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号