首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 832 毫秒
1.
Intermittent operation can affect the heat exchange performance of the vertical ground source heat pump system, thereby affecting life cycle cost (LCC) of the ground source heat pump system. The simulation analysis on the hourly load of an office building is implemented by using the DeST software.The heat exchange model of vertical ground heat exchanger pipe-group and energy consumption model of per part of heat pump system are established. Through the comparison between calculation results of continuous operation for 15 years and calculation results of intermittent operation 15 years of the heat pump system, it can be concluded that the LCC value of intermittent operation decreased by 13.45%,relative to the LCC value of continuous operation, and the average energy saving rate of intermittent operation mode is 17.20% in the entire life cycle. Intermittent operation mode can effectively improve energy efficiency of the ground source heat pump system and reduce the LCC value.  相似文献   

2.
River water quality is one of the important conditions must be considered when river water source heat pump is used. It is also the key factor of efficiency of river water source heat pump. Based on analysis of the water quality factors which influence the river water source heat pump heat exchanger fouling, the main quality indicators and value are conformed. Using fuzzy comprehensive evaluation method and the actual monitoring data, quality classification of river water which is the source of water source heat pump is analyzed. For the difficulty of multiple indicators which need to detect and meet the related national standard in practical engineering application, the definition of scaling potential value is put forward. As the water quality comprehensive evaluation index of water source heat pump, the scaling potential value not only can consider the influence of the main water quality parameters on water source heat pump heat exchanger fouling, but also can conveniently and quickly provide direct basis for water quality judgment and system selection in the engineering application.  相似文献   

3.
Based on an actual ground source heat pump system in hot summer and cold winter area, the system operation parameters were tested for 6 years under the state of using cooling tower for cooling in summer but the ground heat exchanger and fire pool for heating in winter. A three dimensional (3D) tube group model was established, and the thermal balance analysis and calculation of the ground temperature distribution around the ground heat exchanger were conducted by the numerical calculation. According to the comparison between the test data and the theoretical results, the influencing factors of the ground adjustment ability were obtained.  相似文献   

4.
This paper describes the double layer horizontal ground source heat pump systems constructed in 1998 with the buried depth of 0.9 m and 1.8 m. The program of study includes experimental equipments, heat exchanger size, testing meter and methods for data analysis. In addition, the heating and cooling performance at typical days are also illustrated. Among the influencing factors on the performance of the ground source heat pump systems, the parameter of heat exchanger and operation patterns of heat pump systems are analyzed.A heat transfer model has been set up for horizontal heat exchanger.  相似文献   

5.
The vertical U-tube ground-coupled heat pump system provides cold and heat for the controlling of indoor environment. Under the air-conditioning condition, the vertical U-tube ground-coupled heat pump system with heat recovery can provide domestic hot water. The influence of supplying domestic hot water on the heat transfer performance of ground heat exchangers is different under different operating modes in summer and winter. Through a project design of ground-source heat pump system, the influence of supplying domestic hot water under heat storage mode on the heat transfer performance of ground heat exchangers in summer and winter is respectively analyzed. The dynamic performance of heat exchangers under different working conditions is analyzed, and through numerical calculation, the heat transfer performance parameters of ground heat exchangers under different operating modes are obtained. From the calculation results, the adjusting methods based on the load characteristics of this project represent.  相似文献   

6.
This paper introduces the importance of developing the Ground-Source Heat pump and describes the prospects of it.with the method used abroad to acquire the temperature profiles within surrounding soil of the underground heat exchanger with buried tubes, in this paper the line heat source theory and thermal resistance network analysis method were used to set up the heat transfer model.The original temperature of the ground is determined by calculation and is compared with test results. Experiments of running single tube and running three series connection tubes are carried out on the built underground exchangers of vertical buried tube type.And the data which can provide reference for the Ground-Soure Heat pump technique are acquired.  相似文献   

7.
A sewage-water shell-tube heat exchanger with the function of de-fouling was proposed and designed for sewage-source heat pump. Its new simulation program which relies on a distribution parameter computational method was set up. Then the model was solved with the method of Matrix Control. Based on the model, the distribution of bilateral fluid temperature were studied, under the conditions of different flow rates and heat exchange area before and after the de-fouling. Results showed that there will be heat anti-transfer phenomenon if the heat exchanger area is bigger than need and the region of this phenomenon was point out. Setting the function of auto-de-fouling in shell-tube heat exchanger and reducing the equipment's volume accordingly can make the sewage-water heat exchanger run in the best conditions.  相似文献   

8.
地源热泵技术在中国温室设施中的应用探讨   总被引:3,自引:2,他引:3  
当前在中国温室设施中应用和推广地源热泵技术尚存在诸多不利因素,大大限制了该项技术在设施农业领域中的发展。为探寻合理的解决途径,对地源热泵空调系统的关键技术和其在中国的发展概况进行了相关的阐述和分析,并以中国农业大学上庄实验站已经建成使用的地下水式温室地源热泵空调系统为实例,介绍该系统的组成、工作流程、性能参数和使用情况,探讨温室地源热泵空调系统在推广和使用中可能出现的投资较高,长时间运行性能不稳定等问题,分析其原因并提出相应的对策建议。  相似文献   

9.
地埋管地源热泵换热器的换热性能受到不同地质结构的影响。以武汉和重庆地区的典型地质构成为边界条件,建立了三维地埋管的单孔双U管换热模型,通过模型计算,获得了两种地质条件下的地埋管换热性能,以重庆地区的地源热泵热响应测试结果以及工程运行数据出发,对模型的计算结果进行了验证,结果表明,模型吻合度较好,可以应用于工程分析。以模型为条件,进行地质结构对换热性能的影响度分析,预测了两地地埋管地源热泵的换热性能并计算得到换热器的平均换热系数分别为武汉地区K1=1.65(W/m·K),重庆地区K2=1.51(W/m·K)。  相似文献   

10.
In order to improve utilization of cold and heat source from river, turbulence theory and entropy generation theory were adopted to analyze the effect of fouling on convective heat transfer performance in small diameter tube of constant wall temperature.It is found that the entropy generation caused by conduction of fouling plays a more important role in total entropy generation of heat transfer process through a duct than that in cveast rate of caused by temperature difference.The entropy generation caused by viscous flow is more than the entropy generation caused by temperature difference in flow with bigger Reynolds and small radius.The increase rate of entropy generation monotonically increase with Reynolds and the generation process of fouling resistance.Thereafter, the effect of fouling resistance on the heat transfer performance of water source heat pump heat exchanger should be paid more attention, when river water are used as the cold and heat source of heat pump.  相似文献   

11.
This paper describes the annual energy consumption and economic assessment of air-source heat pump(ASHP) and ground-source heat pump(GSHP),based on hourly building load of typical house in Fuzhou.Analysis results show that the energy consumption of GSHP is 15% less than that of ASHP through all year,where there is 13% less in summer and 20% less in winter.Although the seasonal energy efficiency ratio of GSHP in Fuzhou is higher than that of ASHP,it has no obvious effect on the energy efficiency as it is in the hot summer and cold winter zone.In comparison with ASHP,the GSHP is not cost-effective.  相似文献   

12.
This paper introduces the theoretical basis and application method for heat transfer model of buried tube (pipe in pipe and U- type) heat exchanger for ground source heat pump, and a practical example is calculated. Then, the calculation results are analyzed and discussed. In particular, the correlation coefficient and calculation method of tube group exchanger is discussed; the method for determining known parameter and some basic data for main procedure GSHP.HTM is analyzed. The calculation formula and data sampling for JSW.HTM subroutine is introduced. At last, the problems in application of calculation procedure, to which should pay attention, are discussed.  相似文献   

13.
水源热泵在温室加温中的应用研究   总被引:16,自引:1,他引:15  
采用多层覆盖、减小直接加热空间的温室节能设计措施,设计建造了试验温室,在水源热泵热风加温条件下,对试验温室的温度、空气相对湿度、水源热泵的实际制热系数进行了测定,对试验温室采用水源热泵加温的节能效果进行了评价,结果表明:夜间水源热泵加温条件下,温室东西方向的水平温度分布均匀,南北相距12m的水平方向上存在着0.9℃的温差,中部距地面2.2m的垂直空间上平均存在1℃的温差,24:00—08:00,空气相对湿度低于80%;试验用水源热泵实际热系数为3.31。与燃煤锅炉热水加温的玻璃温室相比,试验温室采用水源热泵加温相对节能46.5%,直接加温成本较燃煤锅炉加温高82.2%,经计算,当试验温室与对照玻璃温室面积相等时,采用水源热泵加温可相对节能69.1%,直接加温成本仅较燃煤锅炉加温的玻璃温室高5.8%。  相似文献   

14.
The proportion of radiation load through glass windows in building energy analysis is comparatively great;it is regarded as linear relation with temperature in BIN method,which is extremely a rough method.It is not only because the relation between such radiation load and temperature is far from linear relationship,but also there is lack of objective standard for the selection of corresponding representative temperature to the load.To solve this problem,calculating the maximum factor D_(J max) firstly,then get the hourly corresponding relation of load and temperature by multiplying the hourly cool load coefficient.The practical relation of load and temperature could be obtained by counting up the average load to each temperature at each direction;the load calculation method is still simple using a series of statistic data.A comparison has been made between this method and the former one.As it is the real reflection of relation between the temperature and load,the precision of load calculation is enhanced.The process using this method to calculate load for south facing window in Chengdu is given in this paper.  相似文献   

15.
通过夏季工况的地源热泵运行试验,对运行过程中水平埋管的换热性能参数、试验场地周围气象因素和换热过程中土体的温湿度变化等因素进行实时监测,探讨了地源热泵运行过程中水平埋管换热器热交换性能及其周围土壤的温、湿度场变化规律。研究结果表明,地源热泵间隙运行有利于土壤温度场的恢复,随着停机时间的增加,水平埋管与周围土壤的热交换能力明显提高;气候变化对水平埋管周围土壤的温度场分布具有显著影响,随着埋深的递减,土壤温度受气候变化的影响越明显;水平埋管周围土壤温度的变化幅度随着与埋管距离的增加呈递减趋势,其影响半径为1.0m左右;热交换对水平埋管周围土壤湿度场的影响不明显,但大气降雨引起的地表水入渗对土壤湿度场的分布具有显著影响。  相似文献   

16.
Energy consumption of water intake is one of the key factors for energy saving in the application of the open loop surface water heat pump system. An energy efficiency ratio coupling model for open loop surface water source heat pump systems was established on the basis of the energy consumption model for the water intake and the heat pump units. According to energy saving rate and regulation of energy consumption of water intake, dynamic temperature limits of water intake in different water supply temperature of cooling tower and different pump head were proposed so as to find a calculation method of temperature limits of water intake of open loop surface water heat pumps. Moreover, the energy saving rate of surface water source heat pump systems compared with traditional air conditioning systems under various condition was also calculated.  相似文献   

17.
For the open-loop surface water source heat pump systems, energy consumption of water supply is the key factor for energy saving of system. On the basis of energy consumption model of heat pump unit and energy consumption model of water supply etc., open-loop surface water source heat pump system energy efficiency ratio coupling model is established. Based on energy efficiency ratio,the coupling limit value of surface water source heat pump system in different temperature of water supply and different energy consumption of water supply is obtained.Through the actual case, energy saving rate of the system is calculated in different temperatures of water supply and different system modes. And the determination method of the limit energy consumption of water supply of open-loop surface water source heatpump systems is established.  相似文献   

18.
The physical and mathematical model of three dimensional unsteady coupled heat transfer in the ground heat exchanger is proposed, and corresponding numerical simulations for actual ground heat exchanger and operation condition are carried out. The computed results are compared with those of the thermal resistance test of the ground heat exchanger, which proves the correctness of the model and corresponding numerical methods. Then, the effects of thermal conductivity and specific heat of the ground backfill material on the ground heat exchanger are investigated, which provides theoretical guidance for the thermal response test and the engineering design of the ground heat exchanger.  相似文献   

19.
High thermal resistance resulted by fouling in heat exchanger restricts the application of sewage source heat pump (SSHP) system. The fouling forming mechanism was applied with solid-liquid fluidized bed technique for fouling prevention and removing of SSHP system. Shearing stress model of solid-liquid fluidized bed heat-exchanger is analyzed, and collision stress model is modified. Preventing and removing fouling mechanisms of solid-liquid fluidized bed technique by shearing stress and collision stress was explained. An experimental study on how to solve the fouling problem (such as fouling prevention and removing, heat transfer enhancement, etc) is discussed. The results of theory and experiment show that solid-liquid fluidized bed technique can be used not only to increase convection coefficient, but also to restrict fouling growing, it can effectively solve the fouling problem in SSHP system.  相似文献   

20.
This paper analyzes the fluid flow and heat transfer of the heat exchanger, and obtainsd the distribution of fluid field, heat field and pressure field in heat exchanger. According the analysis result, some modify measure is adopted, such as decreasing the number of tube bundle, the size of baffle plate and increasing the diameter of exchange heat tube. In the new heat exchanger, the resistance decreased 32.3%, is 103.2 Pa and the temperature of the exit is 130 K. The new heat exchanger satisfies the requirement of exchanging heat. The study indicates that adopting the numerical simulation method could get temperature, pressure and fluid - velocity of anywhere of the heat exchanger, and understand effecfing of structure parameter on fluid flied and heat flied of the heat exchanger. Therefore, it provides a new method for optimization design of heat exchanger.  相似文献   