首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A high-throughput liquid chromatography tandem mass spectrometry (HT LC-MS/MS) method for red blood cell (RBC) folate analysis was developed from a previously described manual (M) LC-MS/MS method. The HT LC-MS/MS method used 96-well plates in which RBC folates were hydrolyzed with concentrated HCl in the presence of the [13C6]pABA internal standard (IS). The pH of the hydrolysate was adjusted to 5.0 before cleanup using 96-well plate OASIS HLB SPE cartridges. The analyte and IS were eluted with ethyl acetate/hexane (95:5, v/v) and methylated with methanol and trimethylsilyldiazomethane. The methylated analyte and IS were quantified with LC-MS/MS as previously described. The HT LC-MS/MS method was validated by determining the recovery of six different folate vitamers, which were quantitatively recovered (84-105% with CV<9.0%). RBC folate concentrations in whole blood samples correlated between HT and M LC-MS/MS methods (r=0.922, p<0.0001 for n=43 samples) and between the HT LC-MS/MS method and a chemiluminescence assay (r=0.664, p<0.001 for n=325 samples). Comparison of the results between HT LC-MS/MS and chemiluminescence methods with Bland-Altman difference plots and by ROC curve analysis indicates that the chemiluminescence assay underreports RBC folate concentrations. The HT LC-MS/MS method allows for high-throughput sample preparation for the analysis of RBC folate.  相似文献   

2.
An optimal folate nutritional status is important in minimizing developmental and degenerative disease. Therefore, constant monitoring of folate intake and of biomarkers of folate nutritional status is essential. The objective of this research was to compare two folate intake instruments and validate each one against RBC folate measured by a high-throughput liquid chromatography tandem mass spectrometry (HT LC-MS/MS) method described in the companion paper (Owens, J. E.; Holstege, D. M.; Clifford, A. J. J. Agric. Food Chem. 2007, 55, 3292-3297). A food frequency questionnaire (FFQ) and a folate-targeted semiquantitative Block dietary folate equivalents (DFE) screener were compared and individually validated against an HT LC-MS/MS method. RBC folate was 1178 +/- 259 nmol/L (mean +/- SD) in a population of 337 normal adult subjects. Folate intakes were 556 +/- 265 microg/day by the FFQ and 524 +/- 276 microg/day by the DFE screener. Folate intakes by the DFE screener were approximately 34 microg less than by the FFQ (paired t test, p<0.01), but the intake instruments were highly correlated for total folate intake (r=0.608, p<0.01). Correlations between instruments and RBC folate were low (r<0.35) but strong (p<0.01). ROC curve analysis indicates that the measurement of RBC folate by the HT LC-MS/MS method is a better predictive tool than are intake instruments for the evaluation of marginal folate status.  相似文献   

3.
An effective method using liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed and optimized to obtain a complete separation of five representative plant growth regulators (PGRs) [gibberellic acid, 2,4-dichlorophenoxyacetic acid (2,4-D), thidiazuron, forchlorfenuron, and paclobutrazol] in fruits. Extraction was performed with acetonitrile containing 0.1% (v/v) acetic acid, applying modified quick, easy, cheap, effective, rugged, and safe (QuEChERS) methodology. LC-MS/MS conditions including composition of mobile phases and mass spectrometry (MS) conditions were evaluated to achieve the highest sensitivity in MS detection. All of the data acquisition was employed in the segmented multiple-reaction monitoring mode for the selected negative and positive transition ions. The octadecylsilyl (C18) dispersive solid-phase extraction (SPE) sorbent was found to provide the more satisfied recoveries than primary secondary amine (PSA) and graphitized carbon black (GCB) for five target PGRs. The optimized method allowed for recoveries of 76-112% for the five PGRs from fruit samples with relative standard deviation (RSD) values less than 10%. Limits of quantification (0.5-16.5 μg/kg) were lower than the maximum limit of residues established for PGRs. The results demonstrated that the developed LC-MS/MS and QuEChERS extraction method is highly effective for analyzing trace amounts of target PGRs in fruit samples. Finally, the method was successfully used to detect residual PGRs in Beijing, China, in 2010. The concentrations of 2,4-D (5.1-1503 μg/kg) and paclobutrazol (1-1381 μg/kg) found in orange and peach, respectively, suggesting that the use of these PGRs in these fruits should be regulated in China in the future.  相似文献   

4.
A method for the quantitation of dityrosine in wheat flour and dough by high-performance liquid chromatography/tandem mass spectrometry (HPLC-MS/MS) using an isotope dilution assay with the internal standard 3,3'-(13)C(2)-dityrosine in the single-reaction monitoring mode was developed. The method consisted of the release of protein-bound dityrosine by hydrolysis in 4 mol/L hydrochloric acid/8.9 mol/L propionic acid for 24 h at 110 degrees C after addition of the internal standard, cleanup by C(18) solid-phase extraction, and HPLC-MS/MS. The limit of detection of dityrosine was 80 ng/g of sample (0.22 nmol/g), and the limit of quantitation was 270 ng/g of sample (0.75 nmol/g). The method was sensitive enough to analyze wheat flour and dough and to study the effect of flour improvers on the dityrosine content. Furthermore, the effect of the mixing time was studied. The dityrosine concentration in the flour was 0.66 nmol/g. After we mixed a dough to peak consistency, the dityrosine concentration doubled and remained constant on further mixing. Overdoses of hydrogen peroxide and hexose oxidase (HOX, E.C. 1.1.3.5) resulted in a strongly increased dityrosine content, whereas no increase of the dityrosine concentration was found after the addition of ascorbic acid and potassium bromate. Calculation of the percentage of dimeric tyrosine showed that less than 0.1% of the tyrosine residues of wheat protein were cross-linked. Therefore, dityrosine residues seem to play only a very minor role in the structure of wheat gluten.  相似文献   

5.
A dual label stable isotope dilution assay was developed to trace the deconjugation efficiency of polyglutamic folate vitamers converted to their monoglutamic analogues. For this purpose, [(13)C(5)]-pteroylheptaglutamate was synthesized and added during extraction of foods as a tracer isotopologue along with [(2)H(4)]-5-methyltetrahydrofolate, [(2)H(4)]-5-formyltetrahydrofolate, [(2)H(4)]-tetrahydrofolate, [(2)H(4)]-10-formylfolate, and [(2)H(4)]-folic acid. The [(2)H(4)]-labeled folates were used as internal standards for the monoglutamates. Deconjugation converted the addition tracer [(13)C(5)]-pteroylheptaglutamate to the detection tracer [(13)C(5)]-folic acid, which was quantified along with unlabeled folic acid using [(2)H(4)]-folic acid as the internal standard. LC-MS/MS enabled the unequivocal differentiation of the three isotopologues. This tracing was used to optimize deconjugation efficiency, which was achieved by using 4-morpholineethanesulfonic acid buffer for extraction at pH 5.0 . The optimized assay revealed limits of detection for the folate vitamers ranging between 2.0 and 5.6 pmol per assay (equivalent to 2.2-6.6 μg/100 g dry mass), recoveries ranging between 98 and 105% and relative standard deviations in inter-assay precision ranging between 2 and 6%. The assay was applied to quantitate folates in spinach, beans, cheeses, bread, wheat germs, and yeast .  相似文献   

6.
Ren A  Zhang L  Hao L  Li Z  Tian Y  Li Z 《Public health nutrition》2007,10(8):762-768
OBJECTIVE: To characterise plasma and red-blood-cell (RBC) folate status among pregnant women in an area with an extremely high prevalence of neural tube defects, and to compare them with those of women from a low prevalence area. DESIGN: A cross-sectional survey conducted in 2003. SETTING: One county and one city from each of the high prevalence area and the low prevalence area in China. SUBJECTS: Five hundred and sixty-two women in their first trimester of pregnancy in the high prevalence area and 695 pregnant women in the low prevalence area. RESULTS: Women in the high prevalence area had less than half the plasma and RBC folate concentrations (12.2 and 440.0 nmol l- 1, respectively) of women in the low prevalence area (33.5 and 910.4 nmol l- 1, respectively). In the high prevalence area, 40% of rural women were deficient in RBC folate and 50% were deficient in plasma folate; 20% of urban women were deficient in RBC folate and 30% deficient in plasma folate. In contrast, only 4% (RBC folate) and 6% (plasma folate) of rural women, and 2% (RBC folate) and 1% (plasma folate) of urban women, were folate-deficient in the low prevalence area. Less than 10% of rural and about 26% of urban women in the high prevalence area took folic acid periconceptionally, compared with 70% and 60% of women in the low prevalence area. CONCLUSIONS: Blood folate deficiency is highly prevalent among pregnant women in an area of China with a very high prevalence of neural tube defects.  相似文献   

7.
A simplified HPLC method for rapid determination of folates in yeast with ultraviolet and fluorescence detection without sample purification has been developed. By use of the column Aquasil C(18), specially designed for polar analytes, and gradient elution, it was possible to separate and determine five folate derivatives: tetrahydrofolate, 5-methyltetrahydrofolate, and 5-formyltetrahydrofolate with fluorescence detection, and 10-formylfolic acid and folic acid with ultraviolet detection. The sample preparation required only a small amount of dry yeast (25-50 mg) and included an extraction of folates by heat treatment and deconjugation of folate polyglutamates to monoglutamates with the use of rat serum conjugase. Validation involved investigation of matrix effects, determination of recovery by standard addition method, repeatability, and stability tests. The dominating folate forms in commercial dry baker's yeast were found to be tetrahydrafolate and 5-methyltetrahydrofolate with a total folate content of 2890 microg/100 g (63.4 nmol/g). The simplicity of the method makes it suitable for folate screening studies of different yeast strains.  相似文献   

8.
This paper describes a rapid LC-MS/MS/MS method for the analysis of alpha-amanitin in serum and liver. Serum was initially prepared by precipitation of proteins with acetonitrile and subsequent removal of acetonitrile with methylene chloride. Liver was prepared by homogenization with aqueous acetonitrile and subsequent removal of acetonitrile using methylene chloride. For both matrices, the aqueous phase was then extracted using mixed-mode C18/cation exchange SPE cartridges and analyzed on a linear ion trap LC-MS system. Standards were prepared in extracts of control matrix. Seven replicate fortifications of serum at 0.001 mug/g (1 ng/g) of alpha-amanitin gave a mean recovery of 95% with 8.8% CV (relative standard deviation) and a calculated method detection limit of 0.26 ng/g. Seven replicates of control liver fortified at 1 ng/g gave a mean recovery of 98% with 17% CV and a calculated method detection limit of 0.50 ng/g. This is the first report of a positive mass spectrometric identification and quantitation of alpha-amanitin in serum and liver from suspect human and animal intoxications.  相似文献   

9.
Quantitative methods are detailed for determination of ethyl carbamate in distilled alcoholic beverages by capillary gas chromatography with flame ionization detection (GC/FID) and by packed-column gas chromatography/mass spectrometry (GC/MS) using selected ion monitoring. Five g samples of distillate of known ethanol concentration are diluted with water to 25% ethanol (v/v), washed with petroleum ether, and extracted with dichloromethane prior to GC/FID or GC/MS analysis. As necessary, sample extracts that exhibit GC/FID interference are passed through alumina for additional cleanup. When internal standards (tert-butyl carbamate and n-butyl carbamate for GC/FID, or ethyl 13C-15N-carbamate for GC/MS) were used for quantitation, the limit of detection for ethyl carbamate was in the range of 5-25 ppb. Coefficients of variation ranged from 3.5 to 6.0% for GC/FID determinations, and from 1.4 to 3.2% for GC/MS. Correlation between methods for 22 random distillate samples ranging in concentration from approximately 40 to 800 ppb gave a correlation coefficient (r) of 0.996.  相似文献   

10.
Two methods, one to determine ascorbic acid and one to determine lycopene and beta-carotene, in vegetables and fruits by liquid chromatography coupled with mass spectrometry (LC-MS) have been established. The chromatographic separation of the studied compounds and their MS parameters were optimized to improve selectivity and sensitivity. In both methods, separation was carried out with two coupled columns, first a C(18) and then a dC(18), using as mobile phase 70% methanol (0.005% acetic acid) and 30% acetic acid 0.05% for ascorbic acid determination and a mixture of methanol, tetrahydrofuran, and acetonitrile (60:30:10 v/v/v) for carotenoid analysis in isocratic mode. The molecular ion was selected for the quantification in selective ion monitoring (SIM) mode. Ascorbic acid was detected with electrospray ionization probe (ESI) in negative mode, while chemical ionization atmospheric pressure (APCI) in positive mode was used for the target carotenoids. The methodology for ascorbic acid analysis is based on an extraction with polytron using methanol and a mixture of methaphosphoric acid and acetic acid. Extraction of the carotenoids was carried out with tetrahydrofuran/methanol (1:1) (v/v). The proposed methods were applied, after their corresponding validations, to the analysis of four varieties of tomatoes, tomato in tin enriched and dried tomato, and to the analysis of mango and kiwi fruits, to compare the content in these compounds. Moreover, the influence of the process of freezing and the effect that the manipulation/preservation has in the content of ascorbic acid in tomato have also been studied.  相似文献   

11.
Liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis of the tryptic digest of a cleaned-up food matrix extract was used for the detection of milk allergens. The emphasis of this study was on casein, which is the most abundant milk protein and is also considered the most allergenic. A sample cleanup method was developed using an ion exchange column and centriprep device. Cookies spiked with milk powder from 0 to 1250 ppm were extracted, cleaned up, and either digested directly by trypsin or further cleaned up by gel electrophoresis before digestion. The peptide mixture was analyzed on a capillary LC-quadrupole time-of-flight system. Two marker peptides from alphaS1-casein were identified and used for prescreening. The MS/MS data from the mass spectrometry system were processed with Masslynx v4.0 and submitted for database search using either ProteinLynx Global Server or Mascot for protein identification. The LC-MS/MS method, using casein enzyme-linked immunosorbent assay as a reference, was tested on the cookie matrix and was extended to other sample matrices. There were good agreements between the two. This LC-MS/MS method provides a valuable confirmatory method for the presence of casein. It also allows the simultaneous detection of other milk allergens.  相似文献   

12.
A gas chromatography-mass spectrometry (GC/MS) method for the quantitation of n-alkanes (carbon backbones ranging from 21 to 36 carbon atoms) in forage and fecal samples has been developed. Automated solid-liquid extraction using elevated temperature and pressure minimized extraction time to 30 min per sample as compared to more than 24 h for traditional GC-flame ionization detection methods that use saponification and liquid-liquid extraction. Extraction solvent requirements were also minimized to 10 mL per sample. Under optimal conditions, complete method recoveries, including extraction efficiency, were greater than 91%. The linear dynamic range was 5 to 100 nmol injected onto the column, with a limit of quantitation of 5 nmol. Intra-assay coefficients of variation for the analysis of annual ryegrass (Lolium rigidum), subterranean clover (Trifolium subterranean), and bovine feces ranged from 0.1%-12.9%, where lower concentrations of n-alkane produced a higher degree of imprecision. The reported GC/MS method permits simple, rapid, and precise quantitation of n-alkanes in plant and fecal material and reduces reagent and labor requirements.  相似文献   

13.
Gamma-aminobutyric acid (GABA) is an inhibitory neurotransmitter in animals that is also found in plants and has been associated with plant responses to stress. A simple and relatively rapid method of GABA separation and quantification was developed from a commercially available kit for serum amino acids (Phenomenex EZ:faast) and validated for tall fescue (Festuca arundinacea). Extraction in ethanol/water (80:20, v/v) at ambient temperature yielded detectable amounts of GABA. Clean separation from other amino acids in 28 min was achieved by gas chromatography (GC) with flame ionization detection (FID), using a 30 m, 5% phenyl/95% dimethylpolysiloxane column. The identity of the putative GABA peak was confirmed by GC with mass spectrometric (MS) detection. The relatively small effects of the sample matrix on GABA measurement were verified by demonstrating slope parallelism of GABA curves prepared in the presence and absence of fescue extracts. Limits of quantification and detection were 2.00 and 1.00 nmol/100 microL, respectively. Method recoveries at two different spike levels were 96.4 and 94.2%, with coefficients of variation of 7.3 and 7.2%, respectively.  相似文献   

14.
A simple, sensitive, and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for determining urinary creatinine was developed and used to evaluate 24 h urine samples collected during an exposure study. Urine (1 microL) was diluted with methanol and then directly applied to LC-MS/MS. Under electrospray ionization (ESI) conditions, the transition molecules of creatinine and creatinine- d3 were observed at m/ z 114 > 44 and m/ z 117 > 47, respectively. The retention time of creatinine was 0.59 min. The linear range was 1-2000 ng/mL, with a detection limit in urine of 1 ng/mL. LC-MS/MS and colorimetric end-point methods were significantly associated ( R2 = 0.8785, p < 0.0001). The LC-MS/MS method to determine creatinine in 24 h urine samples had shorter retention times, was more sensitive, reliable, reproducible, simple, selective, and used a smaller sample size than other LC-MS/MS or commercial methods.  相似文献   

15.
Ammonia in cigarette mainstream smoke was quantified by LC-MS/MS after derivatization. Two different reagents, fluorescamine and dansyl chloride, were investigated, but only the latter gave stable derivatives; therefore, it was considered the most appropriate choice. Smoke samples were collected on a Cambridge filter pad followed by an impinger containing a solution of hydrochloric acid. Ammonia was then derivatized with a 18.5 mM solution of dansyl chloride in acetonitrile at 70 °C for 30 min in a vial with the internal standard, (15)ND(4)Cl. The resulting derivative was analyzed by LC-MS/MS detection with an atmospheric pressure chemical ionization (APCI) interface in the positive ionization mode using multiple-reaction monitoring (MRM). Good linearity was obtained in the concentration range of 0.02-1.65 μg/mL (r(2) ≥ 0.999), and the limit of detection (LOD) was established at 0.006 μg/mL. This method has the advantage of being sensitive, efficient, and reliable and is not hindered by interferences from the sample matrix. It should thus be considered a reference method of choice for the determination of ammonia in smoke.  相似文献   

16.
A positive bias in the gas chromatographic (GC) analysis of butter for beta-sitosterol was discovered when attempting to confirm values by gas chromatography/mass spectrometry (GC/MS). The source of the problem was traced to an interfering material that was not effectively separated by packed column GC. Because capillary columns are known to provide superior separation, they were substituted for packed columns in the assay, and instrument parameters were modified accordingly. A compound with a similar retention time, identified by GC/MS as lanosterol, was separated from beta-sitosterol by the capillary column. The capillary column technique was applied to over 300 butter samples. The results indicate that the method can accurately quantitate beta-sitosterol in butter with no known interferences. The limit of detection for this method is 1 mg/100 g. Recoveries at a level of 3 mg/100 g averaged 98% with a coefficient of variation of 3.45%.  相似文献   

17.
A method based on a gel permeation chromatography (GPC) extraction procedure combined with an additional cleanup by solid-phase extraction (SPE) on silica gel and liquid chromatography-mass spectrometry (LC-MS) detection has been validated for the analysis of seven glycidyl esters (GEs) including glycidyl laurate, myristate, palmitate, stearate, oleate, linoleate, and linolenate in various edible oils. This method was conjointly developed and validated by two different laboratories, using two different detection systems, a LC time of flight MS (LC-ToF-MS) and a LC triple-quadrupole MS (LC-MS/MS). The extraction procedure allowed targeting low contamination levels due to a highly efficient matrix removal from the 400 mg oil sample loaded on the GPC column and is suitable for routine analysis as 24 samples can be extracted in an automated and reproducible way every 12 h. GPC extraction combined with SPE cleanup and LC-MS/MS detection leads to a limit of quantification in oil samples between 50 and 100 μg/kg depending on the type of glycidyl ester. Recoveries ranged from 68 to 111% (average = 93%). Quantification was performed by automated standard addition on extracts to compensate matrix effects artifacts. To control recoveries of each sample four isotopically labeled GEs ((13)C(3) or (13)C(4)) were included in the method.  相似文献   

18.
Rugged LC-MS/MS survey analysis for acrylamide in foods   总被引:8,自引:0,他引:8  
The described liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the detection of acrylamide in food entails aqueous room temperature extraction, SPE cleanup, and analysis by LC-MS/MS. The method is applicable to a wide variety of foods. [(13)C(3)]acrylamide is the internal standard. The limit of quantitation is 10 ppb (microg/kg). Data were obtained in duplicate from >450 products representing >35 different food types. The variability in analyte levels in certain food types suggests that it may be possible to reduce acrylamide levels in those foods.  相似文献   

19.
A stable-isotope liquid chromatography-mass spectrometry (LC-MS) assay was developed for the quantitative determination of folic acid in fortified foods. Folic acid was extracted from food samples into a phosphate buffer, purified on a C-18 Sep-Pak cartridge, and analyzed by LC-MS in the negative ion mode using electrospray ionization. The analyte was quantified using (13)C(5)-folic acid as an internal standard. The coefficient of variation for the precision of the method was 5.6% based on the analysis of four sample replicates. The accuracy of the method was assessed using a standard method of addition of folic acid to a shredded whole-wheat cereal. The quantitative determination of folic acid in this matrix was linear over 1 order of magnitude having a concentration range of 2.4 to 24 microg/g of food (or 0.05 to 0.5 microg of analyte injected into the LC-MS). The overall quantitative efficiency of the method was evaluated using a standard reference material (infant formula SRM 1846). The method was applied to the determination of folic acid in several test samples (fortified breakfast cereals), and the values were in accord with the manufacturer's claim. This method advances a LC-MS technique for the determination of folic acid in fortified foods based on stable-isotope dilution methodology. The specificity of the technique and quantitative accuracy of the method in various food substrates suggests that the method may be adapted for routine analysis in other fortified foods.  相似文献   

20.
A cELISA was developed for the coccidiostat nicarbazin. On the basis of previous computer-assisted molecular modeling studies, p-nitrosuccinanilic acid (PNA-S) was selected as a hapten to produce antibodies to 4,4'-dinitrocarbanilide (DNC), the active component of the coccidiostat nicarbazin. Synthesis is described for the hapten [p-nitro-cis-1,2-cyclohexanedicarboxanilic acid (PNA-C)] used in a BSA conjugate as a plate coating antigen. Monoclonal antibodies (Mabs) were isolated that compete with nicarbazin, having IgM(kappa) isotype. Because of the lack of water solubility of nicarbazin, N,N-dimethylformamide (DMF) (3%, v/v) and acetonitrile (ACN) (10%, v/v) were added to the assay buffer to achieve solubility of nicarbazin and related compounds. The Nic 6 Mabs had an IC(35) value for nicarbazin of 0.92 nmol/mL, with a limit of detection of 0.33 nmol/mL. Nic 6 exhibited high cross-reactivity for PNA-S and PNA-C, and 3-nitrophenol, 4-nitrophenol, and 1-(4-chlorophenyl)-3-(4-nitrophenyl) urea. However, Nic 6 had little or no cross-reactivity with 15 other related compounds.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号