首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 906 毫秒
1.
Development of a radioimmunoassay procedure for aflatoxin B1 measurement   总被引:1,自引:0,他引:1  
A radioimmunoassaay (RIA) procedure to measure aflatoxin B(1) (AfB(1)) in agricultural commodities was developed. AfB(1) oxime derivative was synthesized, characterized, and used for preparation of (125)I-labeled AfB(1). Antiaflatoxin B(1) serum was raised in-house using AfB(1)-bovine serum albumin conjugate as immunogen. The assay system was optimized in the range of 0.2-5 ng/mL, using a liquid phase (PEG) as well as a solid phase (coated polystyrene beads) separation system. Inter-assay and intra-assay variations, recovery, and parallelism studies validated the assay. AfB(1) analysis was carried out in nearly 130 samples of different agricultural commodities. The correlation coefficient was determined using commercial ELISA and in-house-developed RIA methods.  相似文献   

2.
Animal feeds occasionally have some degree of contamination by Aspergillus spp. Even pasteurized milk at times contains the toxic liver carcinogen aflatoxin M1 (AFM1). Confirmation of its presence is now done with solid-phase extraction (SPE) and high-performance liquid chromatography (HPLC)-fluorescence, using a small enough sample that SPE time is reasonable. In this study 200 mL of milk was extracted using a C18 disk at a flow rate of approximately 100 mL/min and AFM1 quantified by HPLC-tandem mass spectrometry with negative electrospray ionization. The effectiveness and cleanup efficacy of immunoaffinity columns (IAC) was compared with that of Mycosep multifunctional cleanup columns (MFC). Average recovery and detection limits of whole milk and low-fat milk cleaned up by IAC were significantly superior to those obtained with the MFC (78-87% and 0.59-0.66 ng/L, respectively). The new procedure improves extraction speed, sensitivity, and specificity.  相似文献   

3.
Liquid chromatographic determination of aflatoxin M1 in milk   总被引:1,自引:0,他引:1  
The official AOAC method for aflatoxin M1 in milk was modified by replacing cellulose column chromatography with cartridge chromatographic cleanup and replacing thin layer chromatographic (TLC) determination with liquid chromatographic (LC) quantitation to yield a new method for bovine and porcine milk. An acetone extract of milk is treated with lead acetate and defatted with hexane, and M1 is partitioned into chloroform as in the AOAC method. Chloroform is removed by evaporation under a stream of nitrogen at 50 degrees C. The residue is dissolved in chloroform, the vessel is rinsed with hexane, and the 2 solutions are applied in sequence to a hexane-activated silica Sep-Pak cartridge. Less polar impurities are removed with hexane-ethyl ether, and M1 is eluted with chloroform-methanol, and determined by C18 reverse phase LC using fluorescence detection. Recoveries of M1 added to bovine milk at 0.25, 0.50, and 1.0 ng/mL were 90.8, 93.4, and 94.1%, respectively. The limit of detection was less than 0.1 ng M1/mL for both bovine and porcine milk.  相似文献   

4.
Aflatoxin B1 (B1), T-2 toxin (T2), and ochratoxin A (OA) were assayed in a single extract from barley grain by using competitive enzyme linked immunosorbent assays (ELISAs) with monoclonal antibodies. B1 and T2 monoclonal antibodies were conjugated to horseradish peroxidase for direct competitive ELISA while an indirect competitive ELISA was used for OA determination. The competitive ELISA detected 0.1 ng/mL of B1, 10 ng/mL of T2, or 1 ng/mL of OA. Acetonitrile-0.5% KCl-6% H2SO4 (89 + 10 + 1) extracts of barley grain either were diluted 1:10 for direct assay or were subjected to a simple liquid-liquid cleanup procedure to concentrate the extract 10:1 before assay. For cleanup, water was added to the acetonitrile extract to partition water-soluble interfering substances, and then the mycotoxins were re-extracted with chloroform. The chloroform extract was evaporated to dryness and redissolved in Tris HCl buffer for ELISA. The mean recoveries from barley spiked with 4-60 ng/g of B1, 50-5000 ng/g of T2, and 5-500 ng/g of OA were, respectively, 93.8, 80.6, and 95.8%. The mean within-assay, inter-assay, and subsample coefficients of variation by ELISA of barley grain colonized with toxigenic fungi were less than 12% for B1 and OA but as high as 17% for T2.  相似文献   

5.
The official methods for the quantification of aflatoxin M1 in dairy products (cheese and yogurt) include extraction into dichloromethane or chloroform, evaporation of the solvent, partitioning of the reconstituted residue with hexane, and subsequent analysis. To secure a rapid and inexpensive screen for aflatoxin M1 contamination, a sensitive competitive ELISA, using a rabbit polyclonal antibody, was developed for measuring aflatoxin M1 in milk and used in a comparative study for measuring the extraction efficiency of aflatoxin M1 in aqueous or organic solvent buffers using yogurt samples. An aqueous sodium citrate solution was found to be suitable for extracting aflatoxin M1, thus eliminating the need for organic solvents. The citrate extraction proved to be efficient (recovery ranged from 70 to 124%) in fortified samples of very different kinds of dairy products, including yogurt and six types of cheese. Fourteen yogurt and cheese samples were extracted with citrate solution and analyzed by ELISA. A good correlation was observed (y=0.95x-0.59, r2=0.98) when the data were compared with those obtained through the official method, across a wide range of aflatoxin M1 contaminations (10-200 ng/kg).  相似文献   

6.
A fast and ultrasensitive chemiluminescent enzyme immunoassay for aflatoxin M(1) in milk samples has been developed and validated. The method is an indirect competitive type format involving the immobilization of an aflatoxin M(1)-bovine serum albumin conjugate on 384 well black polystyrene microtiter plates and the use of a secondary antibody labeled with horseradish peroxidase detected with a luminol-based substrate. Aflatoxin M(1) standard solutions were prepared in milk-based buffer, and milk samples were analyzed without any cleanup procedure. The limit of quantification was 1 ppt, the coefficient of variation was below 9% for both intra- and interassay precision, and the recovery ranged from 96 to 122%. The method is specific, and other aflatoxins do not significantly cross-react with the antibody. Twenty-four milk samples were analyzed, and a good correlation was observed (y = 0.98x + 1.71, r(2) = 0.98, n = 24) when the data were compared with a reference high-performance liquid chromatography method with a fluorescent detector. The developed method is suitable for an accurate, sensitive, and high-throughput screening of aflatoxin M(1) in milk samples with a reduction of costs and increased detectability, as compared with previously developed immunoassays.  相似文献   

7.
Competitive direct enzyme-linked immunosorbent assay (ELISA) and the immunochromatographic assay were developed using a monoclonal antibody to detect gentamicin in the animal plasma and milk. No cross-reactivity of the antibody was observed with other aminoglycosides based on competitive direct ELISA, indicating that the antibody is highly specific for gentamicin. On the basis of the standard curves, the detection limits were determined to be 0.9 ng/mL in phosphate-buffered saline (PBS), 1.0 ng/mL in plasma, and 0.5 ng/mL in milk, respectively. Recoveries of gentamicin from spiked plasma and milk at levels of 25-100 ng/mL ranged from 85 to 112%. The concentration of intramuscularly injected gentamicin was successfully monitored in the rabbit plasma through competitive direct ELISA. The detection limits were estimated to be about 6 ng/mL of gentamicin in PBS, plasma, and milk using the colloidal gold-based immunochromatographic assay, which is suitable for the simple screening of gentamicin residues in the veterinary field. Observed positives can be confirmed using a more sensitive laboratory method such as competitive direct ELISA. Therefore, the assays developed in this study could complement each other as well as veterinary field and laboratory findings.  相似文献   

8.
A radioimmunological assay (RIA) to detect chloramphenicol (CAP) residues in eggs, milk, and meat is described. For tissues and other edible products of chloramphenicol-treated animals (chickens, cows, and pigs), the limit of detection is about 200 ng/kg. Residue levels above 1 microgram/kg can easily be quantitated. When highly specific antisera produced in sheep were used, cross-reactivity was insignificant except for metabolites deviating from the parent compound in the acyl side chain only. Thiamphenicol fails to bind to the antisera; hence, it does not interfere with the assay. In the procedure described, the role of cleanup is merely to remove lipids. Thus, skim milk can be analyzed following appropriate dilution without cleanup. The results obtained by RIA were confirmed by gas chromatography with electron capture detection. The new RIA allows rapid, sensitive, and specific screening of large numbers of samples.  相似文献   

9.
Enzyme-linked immunosorbent assay for T-2 toxin metabolites in urine   总被引:3,自引:0,他引:3  
A direct competitive enzyme-linked immunosorbent assay (ELISA) for determination of total T-2 toxin metabolites in urine was developed. The assay involves coating anti-3-acetyl-neosolaniol-hemisuccinate-bovine serum albumin conjugate (anti-3-Ac-NEOS-HS-BSA) antibody to the ELISA plate and using 3-Ac-NEOS-HS-peroxidase as the enzyme marker. Competitive ELISA revealed that the antibody had good cross-reactivity with acetyldiacetoxyscirpenol (Ac-DAS), T-2 tetraol tetraacetate, 3'-OH-Ac-T-2, 3-Ac-NEOS, and 3,4,15-triacetyl-12,13-epoxytrichothec-9-en-8-one (Ac-T-2-8-one), but less cross-reactivity with Ac-T-2 toxin and T-2 toxin. All metabolites of T-2 toxin in urine were converted to T-2 tetraol tetraacetate (T-2-4ol-4Ac) by acetylation of the sample extract before ELISA. To test the ELISA accuracy, a radioimmunoassay (RIA) was performed simultaneously. The linear portion of the standard curve of this direct ELISA for T-2-4ol-4Ac was 0.2-2.0 ng/mL, which was 10 times more sensitive than RIA. The minimum detection level for T-2-4ol-4Ac was 0.02 ng/mL (0.4 pg/assay) in the absence of urine sample. The overall analytical recoveries for T-2 toxin, HT-2, T-2-4ol, 3'-OH-HT-2, NEOS, and a mixture of these 5 toxins added to the urine samples in the ELISA at concentrations of 0.05 and 0.2 ng/mL were 87 and 94%, respectively.  相似文献   

10.
A fast, efficient, and cost-effective method was developed for the analysis of aflatoxins in farm commodities with high-pigment content, such as chili powder, green bean, and black sesame. The proposed method involved matrix solid-phase dispersion (MSPD) and high-performance liquid chromatography (HPLC)-fluorescence detection (FLD) with postcolumn electrochemical derivatization in a Kobra cell. The MSPD procedure combined the extraction with neutral alumina and pigment cleanup with graphitic carbon black (GCB) in a single step. The recoveries of aflatoxins ranged from 88% to 95% with the relative standard deviations (RSD) less than 6% (n = 6). The limits of detection (LODs) were 0.25 ng/g aflatoxin B1, G1, and 0.10 ng/g aflatoxin B2, G2, respectively. The analytical results obtained by MSPD were compared to those of the immunoaffinity column (IAC) cleanup method. No significant differences were found between the two methods by t-test at the 95% confidence level.  相似文献   

11.
A modification of the current revised AOAC method, 26.A10-26.A15, is described for the rapid analysis of aflatoxin M1 in milk and nonfat dry milk. The method incorporates chloroform extraction and eliminates the need for column chromatography by using liquid-liquid partition for sample extract cleanup. Quantitation is carried out by using fluorescence detection combined with high pressure liquid chromatography (HPLC) of aflatoxin M1 which has been converted to aflatoxin M2a with trifluoroacetic acid. The method has a detection limit of 0.014 micrograms/L (2 X signal/noise) for whole milk. For 6 samples of naturally contaminated nonfat dry and freeze-dried milk, the modified method gave an average result of 0.698 micrograms/L; the AOAC method gave an average result of 0.386 micrograms/L.  相似文献   

12.
A chemical cleanup procedure for low-level quantitative determination of aflatoxins in major economically important agricultural commodities using HPLC has been developed. Aflatoxins were extracted from a ground sample with MeOH/H2O (80:20, v/v), and after a cleanup step on a minicolumn packed with Florisil, aflatoxins were quantified by HPLC equipped with a C18 column, a photochemical reactor, and a fluorescence detector. Water/MeOH (63:37, v/v) served as the mobile phase. Recoveries of aflatoxins B1, B2, G1, and G2 from peanuts spiked at 5, 1.7, 5, and 1.7 ng/g were 89.5+/-2.2, 94.7+/-2.5, 90.4+/-1.0, and 98.2+/-1.1, respectively (mean+/-SD, %, n=3). Similar recoveries, precision, and accuracy were achieved for corn, brown and white rice, cottonseed, almonds, Brazil nuts, pistachios, walnuts, and hazelnuts. The quantitation limits for aflatoxins in peanuts were 50 pg/g for aflatoxin B1 and 17 pg/g for aflatoxin B2. The minimal cost of the minicolumn allows for substantial savings compared with available commercial aflatoxin cleanup devices.  相似文献   

13.
Milk is typically screened for beta-lactam antibiotics by nonspecific methods. Although these methods are rapid and sensitive, they are not quantitative and can yield false positive findings. A sensitive and specific method for the quantitation and mass spectral confirmation of five beta-lactam and two cephalosporin antibiotics commonly or potentially used in the dairy industry is described using high-performance liquid chromatography with tandem mass spectrometry. The antibiotics studied were ampicillin, amoxicillin, penicillin G, penicillin V, cloxacillin, cephapirin, and ceftiofur. The antibiotics were extracted from milk with acetonitrile, followed by reversed-phase column cleanup. The extract was analyzed by liquid chromatography coupled with a mass spectrometer, using a water/methanol gradient containing 1% acetic acid on a C-18 reversed-phase column. Determination was by positive ion electrospray ionization and ion trap tandem mass spectrometry. Quantitation was based on the most abundant product ions from fragmentation of the protonated ion for amoxicillin, cephapirin, ampicillin, and ceftiofur and on the fragmentation of the sodium adduct for penicillin G, penicillin V, and cloxacillin. The method was validated at the U.S. FDA tolerance or safe level and at 5 or 2.5 ng/mL for these compounds in bovine milk. Theoretical method detection limits in milk based on a 10:1 signal to noise ratio were 0.2 ng/mL (ampicillin), 0.4 ng/mL (ceftiofur), 0.8 ng/mL (cephapirin), 1 ng/mL (amoxicillin and penicillin G), and 2 ng/mL (cloxacillin and penicillin V) using a nominal sample size of 5 mL.  相似文献   

14.
Protocols for detecting picogram quantities of aflatoxin M1 in dairy products were established. Milk samples were subjected to a reverse phase Sep-Pak C18 cartridge treatment before analysis by an enzyme-linked immunosorbent assay (ELISA) according to previously published procedures. M1 in yogurt, brick cheddar, and ripened Brie cheese was extracted by a modified Pons method, subjected to a normal phase silica cartridge treatment, and analyzed by ELISA. The detection limits for M1 in milk, yogurt, cheddar, and Brie were 10, 10, 50, and 25 ppt (ng/kg), respectively. Recovery for M1 added to these products was in the range 70-110%. Good agreement was found for M1 levels in several naturally contaminated milk samples analyzed by both ELISA and liquid chromatography.  相似文献   

15.
An international collaborative study involving 14 collaborators from 5 different countries was conducted to test a rapid liquid chromatographic (LC) method for detecting aflatoxins M1 and M2 in fluid milk. Each collaborator prepared artificially contaminated milk samples (0.078-1.31 ng M1/mL and 0.030-0.13 ng M2/mL) by adding solutions containing various concentrations of aflatoxins M1 and M2 to fresh milk. Recoveries ranged from 85.2 to 102.5% (av. 93.7%) for aflatoxin M1 and from 99.5 to 126.7% (av. 109.8%) for aflatoxin M2. Coefficients of variation averaged 21.4% (M1) and 35.9% (M2). An analysis of variance was calculated from combined data to determine variance components. The within-laboratory variations (So) (repeatability) were 27.9% (M1) and 23.9% (M2), and the among-laboratory variations (Sx) (reproducibility) were 44.5% (M1) and 64.7% (M2). No visual differences were determined between normal or reverse phase LC for contaminated samples; however, there were an insufficient number of collaborators using normal phase to give meaningful separate statistical data. For 26 observations of uncontaminated milk, 3 false M1 positives were reported for normal phase LC determinations and 2 false M1 positives were reported for reverse phase LC determinations. Three normal phase and 11 reverse phase false M2 positives were reported for 104 observations in uncontaminated milk. The reverse phase LC method for determination of aflatoxins M1 and M2 in fluid milk has been adopted official first action.  相似文献   

16.
A rapid method is described for extraction and cleanup of raw and processed milk for determination of aflatoxins M1 and M2 by using a C18 Sep-Pak/silica gel cleanup column combination. Aflatoxins are separated by normal phase liquid chromatography and their concentrations are determined by fluorescence detection in a silica gel-packed flow cell. Recoveries ranged from 99 to 103% with coefficients of variation less than 2% for M1 levels of 0.117-1.17 ng/mL added to raw milk. Similar recoveries were obtained for M2. The coefficient of variation for analysis of 5 subsamples of naturally contaminated milk was less than 1%. Agreement with the official method is satisfactory. Each sample requires less than 25 mL solvent and 10 min actual handling time. Sample chromatograms show no interferences in the M1-M2 elution region and no late-eluting peaks, which permits spacing injections at 13-20 min intervals. Aflatoxin levels as low as 0.03 ppb may be determined by this procedure. Extracts have also been analyzed by thin layer chromatography.  相似文献   

17.
High-titer rabbit polyclonal antibodies to aflatoxin M(1) (AFM1) were produced by utilizing AFM1-bovine serum albumin (BSA) conjugate as an immunogen. An indirect competitive enzyme-linked immunosorbent assay was standardized for estimating AFM1 in milk and milk products. To avoid the influence of interfering substances present in the milk samples, it was necessary to prepare AFM1 standards in methanol extracts of certified reference material (CRM) not containing detectable AFM1 (< 0.05 ng/g). The reliability of the procedure was assessed by using CRM with AFM1 concentrations of < 0.5 and 0.76 ng/g. Also, assays of milk samples mixed with AFM1 ranging in concentration between 0.5 and 50 ng/L gave recoveries of > 93%. The relative cross-reactivity with aflatoxins (AF) and ochratoxin A, assessed as the amount of AFM1 necessary to cause 50% inhibition of binding, was 5% for AFB1 and much less for AFB2, AFG1, and AFG2; there was no reaction with ochratoxin A. AFM1 contamination was measured in retail milk and milk products collected from rural and periurban areas in Andhra Pradesh, India. Of 280 milk samples tested, 146 were found to contain < 0.5 ng/mL of AFM1; in 80 samples it varied from 0.6 to 15 ng/mL, in 42 samples from 16 to 30 ng/mL, and in 12 samples from 31 to 48 ng/mL. Most of the milk samples that contained high AFM1 concentrations were obtained from periurban locations. The results revealed a significant exposure of humans to AFM1 levels in India and thus highlight the need for awareness of risk among milk producers and consumers.  相似文献   

18.
A simple, rapid enzyme-linked immunoassay (ELISA) was used to evaluate the performance of each step (extraction, filtration, solvent partition, and silica gel column chromatography) of a solvent-efficient thin-layer chromatographic (TLC) method which is undergoing interlaboratory collaborative study for the determination of aflatoxin B1 in corn, raw peanuts, and peanut butter. The apparent average recoveries using the ELISA method were about 30 to 50% higher than those using the TLC method if only the amount of B1 added to the samples was used in the calculations. After the cross-reaction of the antibody with other aflatoxins added to the samples was considered, the amounts recovered approached the levels of aflatoxins added in all 3 commodities tested. With no cleanup treatment, ELISA recoveries at aflatoxin B1 levels above 7.5 ng/g were 84, 79, and 103% for corn, raw peanuts, and peanut butter, respectively. The coefficients of variation were between 5.2 and 25.2%. With each cleanup step in the TLC method, ELISA detected a progressive decrease in recovery from 150.5 to 105.3% (before correction for the presence of other aflatoxins) or from 93.5 to 65.4% (after correction for other aflatoxins) of B1 added to the samples. The ELISA data support the conclusion obtained from previous studies that cleanup treatments were not necessary in the ELISA. When large amounts of other aflatoxins are present, an understanding of the cross-reactivity of antibody with other aflatoxins in the ELISA is essential for final interpretation of the data.  相似文献   

19.
Staphylococcus aureus enterotoxin B (SEB) is a highly heat resistant enteric toxin with a potential as a biothreat agent. A sensitive method for the detection of staphylococcal enterotoxins is needed for food safety and food defense monitoring. The objectives of this research were to develop a competitive fluorescent immunoassay with detection of SEB below toxic levels of 1 ng/mL and to minimize sample preparation. Anti-SEB was immobilized onto carboxylated polystyrene microparticles, and SEB was labeled with fluorescein isothiocyanate (FITC). The concentrations of these reagents were optimized for the detection of SEB below 1 part per billion (1 ng/mL), and other assay conditions (sample volumes and incubation periods) were optimized. Drinking water and milk samples were spiked with 0.125-10 ng/mL SEB and were equilibrated overnight prior to analysis. The water and milk samples were directly analyzed, but heating the milk samples for 10 min at 90 degrees C improved the assay performance. SEB in samples bound with the anti-SEB linked to the latex followed by the competitive binding of SEB-FITC tracer. The excess, unbound tracer was separated by centrifugation, and the fluorescence density of the supernatant was measured. SEB was detected at levels as low as 0.125 ng/mL in drinking water and 0.5 ng/mL in whole milk. This fluorescent latex particle immunoassay will be utilized for the detection of SEB in various foods matrices.  相似文献   

20.
Previous research has demonstrated transmission of zearalenone and alpha- and beta-zearalenols into the milk of cows and other animals. Since human intake of zearalenone and its metabolites via milk is an unknown factor in risk assessment of zearalenone and because appropriate methodology for their determination in milk is not available, a rapid and sensitive analytical method has been developed. Essentially, the method includes extraction with basic acetonitrile, acidification, partition into methylene chloride on a hydrophilic matrix, cleanup on an aminopropyl solid phase extraction column, and reverse-phase liquid chromatography with fluorescence detection. Recoveries from milk averaged 84% for zearalenone, 93% for alpha-zearalenol, and 90% for beta-zearalenol at spiking levels of 0.5 to 20 ng/mL. As little as 0.2 ng/mL of zearalenone and alpha-zearalenol and 2 ng/mL of beta-zearalenol can be detected in milk. These 3 compounds are stable in refrigerated milk for at least 2 weeks and in milk brought to boiling. Enzymes (beta-glucuronidase and aryl sulfatase) may be added to milk prior to extraction to hydrolyze any conjugates.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号