首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Complete assessment of vertebral trauma in dogs currently requires CT and MRI for evaluation of the osseous and soft tissue structures that contribute to vertebral stability. Some studies in people have suggested that MRI may be sensitive and specific at detecting vertebral fractures making this potentially a single modality that could be used in spinal trauma evaluation. This study aimed to assess the ability for observers to evaluate vertebral fractures using MRI when compared to CT, which was used as the reference standard. Twenty‐nine dogs with previously diagnosed acute vertebral fractures and four dogs with no vertebral fracture that had undergone sequential CT and MRI were included into the study. One hundred twenty‐eight vertebrae were evaluated for the presence of fractures. Imaging studies were read by two observers blinded to the history. While both observers had similarly high sensitivity and specificity for simple detection of any fractured vertebrae, interobserver agreement was only moderate (κ = 0.584). When evaluations were specifically limited to detection of structurally unstable fractured vertebrae both observers showed improved specificity and interobserver agreement became substantial (κ = 0.650). Complete agreement for exact fracture location between MRI and CT results was only achieved in 14.3‐32.6% of fractured vertebra with up to 79% of fractures being missed in some vertebral structures. This suggests that although MRI may be able to detect the presence of fractured vertebrae, it is not able to replace CT for the complete evaluation of the traumatized spine and documentation of fracture morphology.  相似文献   

2.
Objective— To validate a technique to assess radial torsion with and without procurvatum and valgus deformity using computed tomography (CT).
Study Design— Anatomic study.
Animals— Radii (n=3) from normal dogs.
Methods— Three cadaveric radii were scanned using CT (3 mm slices). Transverse image sections were assessed at the distal and proximal physeal scar parallel to the joint surface in both sagittal and dorsal planes. Anatomic landmarks of the radius were identified and torsion was measured. A hinged Ilizarov circular external skeletal fixator was constructed to create known procurvatum, valgus, and torsional deformities.
Results— Between observers results were highly correlated for calculation of torsion (r=0.972, r2=0.9448, P <.00001). Mean baseline torsion of the radius in the construct was 4.88°. At 20° procurvatum and valgus, mean calculated torsion was 5.07° (confidence interval [CI]=4.6–5.6°). At 20° procurvatum and valgus with 22.5°-induced torsion, mean measured torsion was 25.4° (expected=27.38°; CI=22.7–28.1°). At 40° procurvatum and valgus and 45°-induced torsion, mean measured torsion was 51.1° (expected=49.88°; CI=−49.2 to 53.0°).
Conclusion— Assessment of radial torsion by CT is reproducible and accurate in the presence of procurvatum and valgus antebrachial angular limb deformities in the dog.
Clinical Relevance— Despite complex presurgical planning, current measurements only allow for measurement of valgus and procurvatum deformities in the sagittal and dorsal planes, this method allows for more precise measurements of radial torsion in the transverse plane.  相似文献   

3.
Objective – To evaluate the effect of 6% hydroxyethyl starch (HES) solution in vivo, with an average molecular weight of 670 kDa and degree of substitution of 0.75, on canine platelet function.
Design – Prospective, controlled-experimental study.
Setting – University of California, Davis, Veterinary Medical Teaching Hospital.
Animals – Seven healthy employee-owned dogs.
Interventions – Seven dogs were included in the treatment group. Four of these dogs also served as the control group. Platelet closure time (CT) was measured using a platelet function analyzer and collagen/ADP cartridges. Dogs were given 20 mL/kg of either sodium chloride 0.9% (control group, n =4) or HES (treatment group, n =7) IV over 1 hour. CT was measured before the infusion, and at 1, 3, 5, and 24 hours after the start of the infusion.
Measurements and Main Results – There was a significant change over time from 0 to 24 hours ( P <0.001), a significant difference between groups across time ( P <0.001), and a significant group-by-time interaction ( P =0.007). At 3 hours, mean CT for the treatment group was 122.3±18.1 seconds, which was significantly different ( P <0.001) from the control group (71.0±3.5 s). At 5 hours, mean CT for the treatment group was 142.7±33.9 seconds, which was significantly different ( P =0.001) from the control group (75.0±8.6 s). Mean CT at 24 hours was within the reference interval for both the control and treatment group (66.0±2.9 and 81.8±11.9 s, respectively); however, CT in 3 individual dogs in the treatment group at this time point remained prolonged.
Conclusions – A clinically relevant dose of HES 670/0.75 prolongs CT in dogs for up to 24 hours. This may be due to platelet dysfunction in addition to the effects of hemodilution, and therefore, may increase the risk of bleeding.  相似文献   

4.
Background: In dogs with congenital portosystemic shunts (CPSS), the ability of the hypoplastic liver to grow is considered important for recovery after surgical shunt attenuation.
Objectives: This study investigated hepatic growth after extrahepatic shunt attenuation in dogs using magnetic resonance imaging (MRI) and computed tomography (CT).
Animals: Ten client-owned dogs with single extrahepatic CPSS.
Methods: Abdominal MRI, CT, or both were performed before and 8 days, 1, and 2 months after shunt attenuation. Liver volumes were calculated from the areas of the MRI or CT images.
Results: Before surgery, median liver volume was 18.2 cm3/kg body weight. Liver volume increased significantly after surgery. Growth was highest between days 0 and 8 and decreased afterward. Median liver volume was 28.8 cm3/kg at 2 months after attenuation. No significant differences in growth were found between dogs with complete or partial shunt closure or between dogs with complete or incomplete metabolic recovery. Volumes measured from consecutively performed MRI and CT images correlated well ( r = 0.980), but volumes from MRI images were significantly larger than volumes from CT images (6.8%; P = .008).
Conclusion and Clinical Importance: After shunt attenuation, rapid normalization of liver size was observed. Hepatic growth was not decreased in dogs after partial closure of CPSS or in dogs with subclinical, persistent shunting 2 months after surgery. CT is the preferred imaging method for volumetric estimation because of speed.  相似文献   

5.
Background: Noninvasive assessment of left ventricular (LV) function is incompletely studied in horses.
Objectives: The goals of this study were to investigate the feasibility, techniques, and reliability of tissue Doppler imaging (TDI) for characterization of LV radial wall motion in healthy horses.
Animals: Three Standardbreds, 3 Thoroughbreds; age 8–14 years; body weight 517–606 kg.
Methods: Repeated echocardiographic examinations were performed by 2 observers in unsedated horses using TDI. Test reliability was determined by estimating measurement variability, within-day interobserver variability, and between-day interobserver and intraobserver variability of all echocardiographic variables. Variability was expressed as coefficient of variation (CV) and the absolute value below which the difference between 2 measurements will lie with 95% probability.
Results: Assessment of LV radial wall motion by TDI was feasible in all horses. Measurement variabilities were very low (CV < 5%) to low (CV 5–15%) for most variables. Within-day interobserver variability as well as between-day interobserver and intraobserver variabilities were low to moderate (CV 16–25%) for most variables. All pulsed-wave TDI variables of systolic LV function showed very low to low variability, whereas some of the variables of LV diastolic and LA function showed moderate to high (CV > 25%) variability. Pulsed-wave TDI variables appeared more reliable than color TDI variables.
Conclusions and Clinical Importance: Measurement of TDI indices of LV function is feasible and reliable in adult Standardbred and Thoroughbred horses. The clinical relevance of LV function assessment by TDI remains to be determined.  相似文献   

6.
OBJECTIVE: To evaluate nonselective computed tomographic (CT) venography for evaluating the cervical internal vertebral venous plexus (IVVP), define the diameter and area dimensions of the IVVP, and determine the relationship between dimensions of the cervical IVVP and other vertebral components in medium-sized dogs. Animals-6 healthy dogs that weighed 18 to 27 kg. Procedure-Helical CT scans were performed from C1 to C7 before and after IV injection of contrast medium (480 mg of iodine/kg) and a continuous infusion (240 mg of iodine/kg). Image data were transferred to a CT workstation, and measurements were performed on displayed transverse images. Diameter and area measurements of the vertebral canal, dural sac, IVVP, and vertebral body were obtained at C3 to C7. RESULTS: Opacification of vertebral venous structures was achieved in all dogs with no adverse reactions. Sagittal diameters of the IVVP for C3 to C7 ranged from 0.6 to 3.2 mm. Transverse diameters ranged from 2.32 to 5.74 mm. The IVVP area represented 12.4% of the mean vertebral canal transverse area and 30.61% of the mean vertebral epidural space area. Area measurements of the IVVP were significantly correlated with vertebral canal area and dural sac area. CONCLUSIONS AND CLINICAL RELEVANCE: Results indicated that nonselective CT venography is a safe, sensitive method for performing morphometric assessments of the cervical IVVP in dogs. Findings support the theory that there may be a physiologic or developmental relationship between cervical vertebral canal components.  相似文献   

7.
Magnetic resonance imaging (MRI) is commonly used to diagnose degenerative lumbosacral stenosis; however, studies show limited correlation between imaging and clinical signs. The purpose of this prospective observer agreement study was to use dynamic MRI of the lumbosacral (LS) spine of healthy dogs to determine reliable reference ranges. Twenty‐two healthy large breed dogs were prospectively enrolled. MRI of the LS spine was performed in T2‐weighted, T1‐weighted, and T2‐weighted SPACE sequences in neutral, flexed, and extended positions. Four observers performed image analyses. Measurements included LS angle, vertebral canal height and area, and LS foraminal areas. Ordinal categorical assessment of loss of fat signal in the foramina, LS compression, intervertebral disc (IVD) degeneration, spondylosis, and IVD protrusion was also performed. The majority of values were significantly larger in flexion versus neutral position, and significantly smaller in extension versus neutral position (P < .05). Subclinical compression and IVD protrusion was noted in a neutral position in 45% and 55% of dogs and in an extended position in 85% and 73% of dogs, respectively. Interobserver agreement was strong (intracluster correlation coefficient [ICC] > .5) except for the L7:LS vertebral canal area ratio (ICC ≤ .03). Intraobserver agreement was high (rho > .5) for all measurements except for the mid‐L6:LS vertebral canal height ratio (rho = .38). There was poor interobserver agreement for loss of fat signal in the foramina and evidence of compression. This study provides the groundwork for future studies using dynamic MRI to evaluate dogs with signs of clinical LS disease.  相似文献   

8.
Objective— To evaluate outcome after closed fluoroscopic-assisted application of spinal arch external skeletal fixators in dogs with vertebral column injuries.
Study Design— Retrospective case series.
Animals— Dogs with traumatic vertebral column injuries (n=5).
Methods— Medical records of dogs with vertebral column fractures and/or luxations stabilized with spinal arch external skeletal fixator frames applied using a closed fluoroscopic-assisted technique were reviewed. Owners were contacted to obtain long-term clinical outcomes.
Results— Five dogs (age range, 6–72 months; weight, 10–54 kg) had traumatic vertebral column injuries stabilized with spinal arch external skeletal fixators applied in closed fashion. Injuries involved vertebral segments of the thoracolumbar junction, lumbar spine, and lumbosacral junction. Immediately postoperatively, 4 dogs had anatomic alignment of their vertebral fracture/luxation; 1 dog had 1 mm of vertebral canal height compromise. Time to fixator removal ranged from 65 to 282 days (141±87 days). All dogs had regained satisfactory neurologic function by 3 months. At long-term follow-up (range, 282–780 days; mean 445±190 days) all dogs were judged to have good to excellent return of function by their owners.
Conclusion— Successful closed fluoroscopic-assisted application of external skeletal fixators using spinal arches provided satisfactory reduction with few complications in 5 dogs. Return to function was judged to be good to excellent in all dogs at long-term evaluation.
Clinical Relevance— Closed fluoroscopic-assisted application of ESF using spinal arches provided satisfactory reduction and effective stabilization of spinal fractures with few complications and should be considered as a treatment approach.  相似文献   

9.
Objective— To evaluate the safety of the angle of insertion of bicortical implants in Doberman Pinschers affected by caudal cervical spondylomyelopathy (CCSM) using simulation on computed tomography (CT) images.
Animals— Doberman Pinschers (n=9) with dynamic spinal compression attributed to CCSM.
Methods— Dogs had CT evaluation of the cervical vertebral column. Digital images were used to evaluate the safety of bicortical implant insertion from the midline at 30, 35, and 40° inclination by drawing a line simulating implant position. Correct surgical positioning of dogs was evaluated by measuring the degree of rotation of the spine along the longitudinal axis.
Results— Insertion of an implant at 30, 35, and 40° inclination was considered safe in 42%, 59%, and 67% of selected sites. Rotation of the spine from 9° counter clockwise to 10° clockwise along the longitudinal axis occurred in 53% of the areas considered.
Conclusions— These results suggest that bicortical implants in the caudal cervical area in Doberman Pinschers affected by CCSM carry a high risk of vertebral canal and intervertebral foramina violation.
Clinical Relevance— Bicortical implants inserted at 30 and 35° in the caudal cervical area in Doberman Pinschers affected by CCSM carry a high risk of vertebral canal and intervertebral foramina violation. CT planning for individual dogs can facilitate selection of the appropriate insertion plane and vertebral column rotation needs to be considered in surgical planning.  相似文献   

10.
Intracranial hypertension is a cause of cerebral ischemia and neurologic deficits in dogs. Goals of this retrospective study were to test interobserver agreement for MRI measurements of optic nerve sheath diameter and associations between optic nerve sheath diameter, signalment data, and presumed intracranial hypertension status in a cohort of dogs. A veterinary radiologist interpreted scans of 100 dogs and dogs were assigned to groups based on presence or absence of at least two MRI characteristics of presumed intracranial hypertension. Two observers who were unaware of group status independently measured optic nerve diameter from transverse T2‐weighted sequences. Mean optic nerve sheath diameter for all dogs was 3 mm (1–4 mm). The mean difference between observers was 0.3 mm (limits of agreement, ?0.4 and 1.0 mm). There was no correlation between optic nerve sheath diameter and age for either observer (r = ?0.06 to 0.00) but a moderate positive correlation was observed between optic nerve sheath diameter and body weight for both observers (r = 0.70–0.76). The 22 dogs with presumed intracranial hypertension weighed less than the 78 dogs without (P = 0.02) and were more often female (P = 0.04). Dogs with presumed intracranial hypertension had a larger ratio of optic nerve sheath diameter to body weight for each observer‐side pair (P = 0.01–0.04) than dogs without. Findings indicated that the ratio of MRI optic nerve sheath diameter relative to body weight may be a repeatable predictor of intracranial hypertension in dogs.  相似文献   

11.
Indicators of pulmonary hypertension in dogs examined with thoracic computed tomography (CT) are not well established in the veterinary literature. In humans, the main pulmonary artery to aortic diameter ratio (MPA:Ao) measured via CT, has been shown to be more sensitive than echocardiographic variables for predicting presence and severity of pulmonary hypertension, in some cases. In veterinary literature, the MPA:Ao has been determined echocardiographically to have an upper limit of about 1:1. Measurement of this ratio has not been described in dogs using CT. The objectives of this cross‐sectional, prospective study were to compare echocardiographic measurement of MPA:Ao with that obtained via CT, determine if measurement of MPA:Ao via CT is repeatable and reproducible, and determine the effect of respiration and contrast administration on the measurement of MPA:Ao via CT. Ten healthy dogs without pulmonary hypertension were anesthetized to undergo thoracic CT using three protocols and echocardiography. The MPA:Ao was measured three times by three observers for each of the three CT protocols and compared to echocardiographic measurements. The mean MPA:Ao measured among all observers and CT protocols was 1.108 ± 0.152 (SD). The effect of CT scan protocol on MPA:Ao significantly differed among the three methods (P = 0.0014), where expiratory scans had lower MPA:Ao than inspiratory scans. The ratio measured on inspiratory CT scans consistently overestimated MPA:Ao when compared to echocardiography (bias = 0.226). Findings did not support the echocardiographically derived upper limit of MPA:Ao as an upper limit for determination of main pulmonary arterial enlargement on CT.  相似文献   

12.
Two dogs (4 and 38 kg) with radiographic evidence of pulmonary nodules were evaluated using single-slice, helical computed tomography (CT). Each thorax was scanned using 12 combinations of examination parameters that included slice collimation width (3 and 5 mm for the small dog and 5 and 7 mm for the large dog), pitch (1, 1.5, and 2), and reconstruction interval (0.5 and 1). Sensitivity, specificity, and accuracy for nodule detection were evaluated for each protocol by three different observers, their results being compared with a consensus evaluation of images acquired with the protocol providing the best theoretic resolution (narrow collimation, pitch of 1, reconstruction interval of 0.5). For all observers, sensitivity and accuracy were significantly increased when using a protocol with narrow collimation ( P <0.0001–0.005 and P =0.0003–0.005, respectively). Pitch and reconstruction interval did not significantly influence the accuracy, sensitivity, or specificity for at least two of the observers. Additionally, nodule size (<3 mm vs. ≥3 mm) did not significantly affect nodule detection. Interobserver repeatability was variable among protocols (κ=0.32–0.78), highlighting the fact that nodule detection may be more dependent on the observer than on the choice of the CT protocol. For single-slice CT, the results of this study suggest that narrow collimation (3–5 mm, depending on the animal's size), a pitch of 2 and a reconstruction interval of 1 should be used in dogs for the detection of pulmonary nodules.  相似文献   

13.
Objectives— To compare the precision of radiography and computed tomography (CT) preoperatively in the standing position for identification of guidelines for screw insertion in the distal phalanx, and to identify whether standing CT might improve operative time compared with preoperative radiographic planning.
Study Design— Experimental ex vivo study.
Animals— Cadaveric equine thoracic limb pairs (n=10).
Methods— Insertion of a 4.5 mm cortex screw in lag fashion into an intact distal phalanx was evaluated in 2 groups (n=10) of cadaveric equine thoracic limbs. In 1 group, the site, direction, and length of the implant were determined by radiography, and in the other group, by CT. Accuracy of screw placement was verified by specimen dissection. Outcomes were (1) absence of penetration of the articular surface, the solar surface, or the semilunar canal (2) appropriate length and direction of the screw. Surgical time was also measured.
Results— No screw penetrated the articular surface, the solar surface, or the semilunar canal in either group. CT was more accurate to identify guidelines for screw insertion (U=23.50, P =.049). With CT, surgical time (mean, 7.7 minutes) was significantly shorter (U=0.000, P =.000) than with radiography (mean, 12.7 minutes).
Conclusion— Standing CT can be used to accurately determine anatomic landmarks for screw insertion in lag fashion in sagittal fractures of the distal phalanx.
Clinical Relevance— This study has a clear clinical relevance for improved internal fixation of sagittal fractures of the distal phalanx.  相似文献   

14.
The aims of this study were to assess the repeatability and reproducibility of transabdominal ultrasonography to assess intestinal wall thickness in adult Thoroughbred horses (n=8). Ultrasonographic cineloops were captured by one examiner from each horse for five consecutive days. During each examination at least three cineloops were obtained for five different intestinal tract locations. Measurements were performed by three separate observers to assess reproducibility and measured on three separate occasions by three observers to evaluate short‐term repeatability. The repeatability of measurements from the duodenum (0.3 ± 0.04 cm), jejunum (0.29 ± 0.05 cm), ventral colon (0.37 ± 0.01 cm), and cecum (0.42 ± 0.03 cm) were good ( P >0.291). The reproducibility of measurements from the duodenum, jejunum, and ventral colon were good ( P >0.394). Reproducibility of measurement of the cecal wall was inadequate ( P =0.01), although the maximum difference between observers was 0.07 cm. It was possible to image all areas on all days, with the exception of the duodenum, which could not be imaged in one horse, on 1 day. Equine intestinal wall measurements are therefore repeatable and reproducible with the exception of reproducibility of the measurements of cecal wall. Although an accepted clinical technique, measurement of cecal wall thickness from intestinal ultrasound images in a clinical setting must be interpreted with care.  相似文献   

15.
Computed tomography (CT) provides excellent bony detail, whereas magnetic resonance (MR) imaging is superior in evaluating the neural structures. The purpose of this prospective study was to assess interobserver and intermethod agreement in the evaluation of cervical vertebral column morphology and lesion severity in Great Danes with cervical spondylomyelopathy by use of noncontrast CT and high‐field MR imaging. Fifteen client‐owned affected Great Danes were enrolled. All dogs underwent noncontrast CT under sedation and MR imaging under general anesthesia of the cervical vertebral column. Three observers independently evaluated the images to determine the main site of spinal cord compression, direction and cause of the compression, articular process joint characteristics, and presence of foraminal stenosis. Overall intermethod agreement, intermethod agreement for each observer, overall interobserver agreement, and interobserver agreement between pairs of observers were calculated by use of kappa (κ) statistics. The highest overall intermethod agreements were obtained for the main site of compression and direction of compression with substantial agreements (κ = 0.65 and 0.62, respectively), whereas the lowest was obtained for right‐sided foraminal stenosis (κ = 0.39, fair agreement). For both imaging techniques, the highest and lowest interobserver agreements were recorded for the main site of compression and degree of articular joint proliferation, respectively. While different observers frequently agree on the main site of compression using both imaging techniques, there is considerable variation between modalities and among observers when assessing articular process characteristics and foraminal stenosis. Caution should be exerted when comparing image interpretations from multiple observers.  相似文献   

16.
Canine cervical vertebral instability is a complex syndrome involving cervical spinal cord compressive lesions. Doberman pinschers and Great Danes are the most commonly affected breeds. Measurements of vertebral canal diameter (VCD), vertebral body height (H), and vertebral body length (L) were made from C3-C7 in 24 Doberman pinschers and 8 Great Danes by using digital and analog techniques. Significant differences between affected and unaffected sites were noted for Doberman pinschers at C6 (P = 0.039) and C7 (P = 0.027) using analog measurements of VCD/H, and Great Danes at C6 using analog (P = 0.041) and digital (P = 0.004) measurements of VCD/L. Cervical vertebral ratios have potential as a breed-specific screening tool for cervical vertebral instability and warrant longitudinal studies.  相似文献   

17.
Deep phenotyping tools for characterizing preclinical morphological conditions are important for supporting genetic research studies. Objectives of this retrospective, cross‐sectional, methods comparison study were to describe and compare qualitative and quantitative deep phenotypic characteristics of lumbosacral stenosis in Labrador retrievers using computed tomography (CT). Lumbosacral CT scans and medical records were retrieved from data archives at three veterinary hospitals. Using previously published qualitative CT diagnostic criteria, a board‐certified veterinary radiologist assigned dogs as either lumbosacral stenosis positive or lumbosacral stenosis negative at six vertebral locations. A second observer independently measured vertebral canal area, vertebral fat area, and vertebral body area; and calculated ratios of vertebral canal area/vertebral body area and vertebral fat area/vertebral body area (fat area ratio) at all six locations. Twenty‐five dogs were sampled (lumbosacral stenosis negative, 11 dogs; lumbosacral stenosis positive, 14 dogs). Of the six locations, cranial L6 was the most affected by lumbosacral stenosis (33%). Five of six dogs (83%) with clinical signs of lumbosacral pain were lumbosacral stenosis positive at two or more levels. All four quantitative variables were significantly smaller at the cranial aspects of the L6 and L7 vertebral foramina than at the caudal aspects (P < 0.0001). Fat area ratio was a significant predictor of lumbosacral stenosis positive status at all six locations with cranial L6 having the greatest predictive value (R2 = 0.43) and range of predictive probability (25–90%). Findings from the current study supported the use of CT as a deep phenotyping tool for future research studies of lumbosacral stenosis in Labrador retrievers.  相似文献   

18.
Background: Choroid plexus tumors (CPTs) comprise approximately 10% of all primary brain tumors in dogs. The clinical utility of magnetic resonance imaging (MRI), cerebrospinal fluid (CSF) analysis, or both in the presumptive diagnosis of CPTs has not been determined.
Objectives: To report MRI and CSF findings in dogs with CPT and determine if there are distinguishing features that allow clinical discrimination between the tumor grades.
Animals: Fifty-six client-owned dogs with naturally occurring CPT.
Methods: Retrospective case series. The inclusion criterion was histologically confirmed CPT. Blinded review of cranial MRI and cisternal CSF analysis was performed.
Results: Thirty-six of 56 dogs had a choroid plexus carcinoma (CPC) and 20 had a choroid plexus papilloma (CPP). Golden Retrievers were overrepresented compared with the hospital population (frequency 3.7 times that expected, confidence interval 95%= 2.0–6.7, P < .0002). Median CSF protein concentration in CPCs (108 mg/dL, range 27–380 mg/dL) was significantly higher than in CPPs (34 mg/dL, range 32–80 mg/dL) ( P = .002). Only dogs with CPCs had a CSF protein concentration >80 mg/dL. Cytological evidence of malignancy in CSF was seen in 7 of 15 CPCs. Only CPCs had evidence of intraventricular or subarachnoid metastases on MRI.
Conclusions and Clinical Importance: MRI, CSF analysis or both can help to differentiate between CPPs and CPCs, and may provide valuable prognostic and pretreatment information.  相似文献   

19.
Background: Pituitary tumors in dogs can be adenomas, invasive adenomas, or adenocarcinomas. In people, invasive adenomas and pituitary adenocarcinomas carry a worse prognosis than adenomas.
Hypothesis/Objective: To identify differentiating features on cross-sectional imaging in dogs with pituitary adenomas, invasive adenomas, and adenocarcinomas.
Animals: Thirty-three dogs that had computed tomography (CT) or magnetic resonance imaging (MRI) performed and a necropsy diagnosis of pituitary adenoma ( n = 20), invasive adenoma ( n = 11), or adenocarcinoma ( n = 2).
Methods: Medical records were retrospectively reviewed for signalment, history, and diagnosis. CT and MR images were reviewed for characteristics of pituitary tumors.
Results: Mean (± standard deviation) age for dogs with pituitary adenomas (10.6 ± 2.9 years) was greater than that of those with invasive adenomas (8.3 ± 2.7 years, P = .04). Eighteen out of 20 (90%) dogs with adenomas had contrast-enhancing masses. Thirteen out of 20 (65%) had homogeneous enhancement. Mean adenoma height was 1.2 ± 0.7 cm. Eight out of 20 (40%) adenomas were round and 8/20 (40%) compressed surrounding brain. Eleven out of 11 dogs (100%) with invasive adenomas had contrast-enhancing masses. Seven out of 11 (64%) masses were homogeneous. Mean invasive adenoma height was 1.8 ± 0.7 cm, which was significantly greater than adenomas ( P = .03). Mass shape varied from round to oval to irregular. Six out of 11 (55%) masses compressed surrounding brain. Clinical and imaging features were variable for 2 dogs with adenocarcinomas.
Conclusions and Clinical Relevance: Invasive adenoma should be suspected if a dog with a pituitary tumor is <7.7 years of age and has a mass >1.9 cm in vertical height. Adenocarcinomas are uncommon and metastatic lesions were not seen with imaging.  相似文献   

20.

Background

Sagittal ratio values (SRVs) of cervical vertebrae are used for ante‐mortem diagnosis of cervical vertebral stenotic myelopathy, but intraobserver and interobserver variability in measurement may influence radiographic interpretation of vertebral stenosis in horses with neurological disease.

Objectives

To determine intraobserver repeatability in SRVs, intra‐ and interobserver agreement in SRVs and whether or not agreement was influenced by animal age.

Animals

Forty‐two horses (>1 year old) with neurological disease from which laterolateral computed radiographic images of C2–C7 were obtained.

Methods

Four observers made measurements from C2 to C7 for each horse and interobserver agreement for intra‐ and intervertebral SRVs was determined using Bland–Altman analysis (acceptable agreement: limits of agreement [LOA] ≤ 0.05) on all horses and those ≤3 (n = 25) and >3 (n = 17) years old. Each observer also made repeated measurements for 10 horses and intraobserver repeatability and agreement were determined.

Results

Adequate intraobserver repeatability was achieved for 6 sites. Within observers, paired measurements had a median difference ≤5.7%, but a large range in differences often occurred, most frequently at intervertebral sites. For C5, C6, C7, and C3–4, LOA ≤ 0.05 were achieved by at least 1 observer. With the exception of C5 for 1 pair, LOA were >0.05 for interobserver agreement, regardless of animal age. LOA were largest at intervertebral sites.

Conclusions and Clinical Importance

Within and between observers, measurement error may limit the diagnostic accuracy of SRVs and result in discrepancies of diagnosis and treatment and warrants consideration when used clinically in horses with neurological disease.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号